• Title/Summary/Keyword: Radiation shielding efficiency

Search Result 78, Processing Time 0.022 seconds

An Experimental Study on the Development of Electromagnetic Shielding Concrete Wall for Shielding High-altitude Electromagnetic Pulse (HEMP) (고고도 전자기파(HEMP)차폐를 위한 전자파 차폐 콘크리트 벽체 개발에 관한 실험적 연구)

  • Choi, Hyun-Jun;Kim, Hyung-Chul;Lim, Sang-Woo;Lee, Han-Seung
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.2
    • /
    • pp.169-177
    • /
    • 2017
  • Rather than causing damage from heat, blast, and radiation of a regular nuclear weapon, recently, it is predicted that North Korea has been inventing high altitude electromagnetic pulse (HEMP) missile in order to incapacitate electronic equipment. HEMP shielding facility is used for military purpose today. Despite the electromagnetic shielding effects from high quality compression plates, problems may include such as the possibility of electromagnetic influx resulting in the welding of the compression plates, and difficulties and high cost of construction. Therefore, in this study, a high electrical conducting material was added to the concrete experimental subject to ensure the shielding effect through electromagnetic waves to for the concrete structure, instead of building a shielding facility separately for the structure. Also, among the experimental subjects, 100 ${\mu}m$ of Iron-Aluminum alloy metal spraying coat was applied to two types with the highest shielding effect, and to two types with the lowest shielding effect. The result of the experiment indicates that experimental subjects added with a high electrical conductivity material did not meet the minimum shielding criteria of MIL-STD-118-125-1 standard, but all the experimental material applied to the metal spraying coating satisfied the minimum shielding criteria. In conclusion, it is considered that 100 µm of Iron-Aluminum alloy metal spraying coat contains high efficiency in the HEMP shielding.

Feasibility study of spent fuel internal tomography (SFIT) for partial defect detection within PWR spent nuclear fuel

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Hyun Joon Choi;Hakjae Lee;Yong Hyun Chung;Chul Hee Min
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2412-2420
    • /
    • 2024
  • The International Atomic Energy Agency (IAEA) mandates safeguards to ensure non-proliferation of nuclear materials. Among inspection techniques used to detect partial defects within spent nuclear fuel (SNF), gamma emission tomography (GET) has been reported to be reliable for detection of partial defects on a pin-by-pin level. Conventional GET, however, is limited by low detection efficiency due to the high density of nuclear fuel rods and self-absorption. This paper proposes a new type of GET named Spent Fuel Internal Tomography (SFIT), which can acquire sinograms at the guide tube. The proposed device consists of the housing, shielding, C-shaped collimator, reflector, and gadolinium aluminum gallium garnet (GAGG) scintillator. For accurate attenuation correction, the source-distinguishable range of the SFIT device was determined using MC simulation to the region away from the proposed device to the second layer. For enhanced inspection accuracy, a proposed specific source-discrimination algorithm was applied. With this, the SFIT device successfully distinguished all source locations. The comparison of images of the existing and proposed inspection methods showed that the proposed method, having successfully distinguished all sources, afforded a 150 % inspection accuracy improvement.

A Study on Dose Distribution around Fletcher-Suit Colpostat Containing $^{137}Cs$ Source ($^{137}Cs$ 선원을 내포한 Fletcher-Suit Colpostat 주위의 선량분포에 관한 연구)

  • Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.263-268
    • /
    • 1988
  • This paper presents dose distributions in water around Fletcher-Suit colpostat containing $^{137}Cs$ tube, and shielding effect of Internal lead shield. Using ready packed film, author measured dose distribution in water around the colpostat containing cesium source. Nine sheets of films on one side of the colpostat are packed with acryl frames cut out so as to fill water, and irradiated in water by cesium source in the colpostat. Dose distributions on transverse plane and upper plane 0.5cm from upper surface of the colpostat were measured. Shielding effect was greater in upper medial direction than in lower medial direction. And that was the greatest around $30^{\circ}$ from the axis of the colpostat on upper side and around $50^{\circ}$on lower side. In the region 7cm from the center of the colpostat, shielding efficiency was 0.23 to 0.35 on the lower $50^{\circ}$ and 0.26 to 0.42 on the upper $30^{\circ}$, and decreased with increase of distance.

  • PDF

Evaluation of the Usefulness of Patient Customized Shielding Block Made with 3D Printer in the Skin Cancer Electron Beam Therapy (전자선치료 시 3D 프린터로 제작한 환자 맞춤형 차폐체의 유용성 평가)

  • Ahn, Ki-Song;Jung, Woo-Chan;Kim, Dae-Hyun;Kim, Moo-Sub;Yoon, Do-Kun;Shim, Jae-Goo;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.447-454
    • /
    • 2019
  • In order to improve and supplement the shielding method for electron beam treatment, we designed a patient-specific shielding method using a 3D printer, and evaluated the usefulness by comparing and analyzing the distribution of electron beam doses to adjacent organs. In order to treat 5 cm sized superficial tumors around the lens, a CT Simulator was used to scan the Alderson Rando phantom and the DICOM file was converted into an STL file. The converted STL file was used to design a patient-specific shield and mold that matched the body surface contour of the treatment site. The thickness of the shield was 1 cm and 1.5 cm, and the mold was printed using a 3D printer, and the patient customized shielding block (PCSB) was fabricated with a cerrobend alloy with a thickness of 1 cm and 1.5 cm. The dosimetry was performed by attaching an EBT3 film on the surface of the Alderson Rando phantom eyelid and measuring the dose of 6, 9, and 12 MeV electron beams on the film using four shielding methods. Shielding rates were 83.89%, 87.14%, 87.39% at 6, 9, and 12 MeV without shielding, 1 cm (92.04%, 87.48%, 86.49%), 1.5 cm (91.13%, 91.88% with PSCB), 92.66%) The shielding rate was measured as 1 cm (90.7%, 92.23%, 88.08%) and 1.5 cm (88.31%, 90.66%, 91.81%) when the shielding block and the patient-specific shield were used together. PCSB fabrication improves shielding efficiency over conventional shielding methods. Therefore, PSCB may be useful for clinical application.

The influence of Ni ion addition on the microstructure and gamma ray shielding ability of ferromagnetic CuFe2O4 ceramic material

  • Mohammad W. Marashdeh;Fawzy H. Sallam;Ahmed M. Abd El-Aziz;Mohamed I. Elkhatib;Sitah f. Alanazi;Mamduh J. Aljaafreh;Mohannad Al-Hmoud;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2740-2747
    • /
    • 2024
  • The sintering process acquired ferromagnetic copper ferrite ceramic material with a small concentration of Ni ion at 1100 ℃ for 1 h. Previously, copper ferrite with Ni proportions powder was acquired by the wet chemical process according to the relation CuFe2-xNixO4 where x takes values 0.0, 0.015, 0.03, 0.04, and 0.05. The role of Ni ion in the copper ferrite structure was investigated by X-ray analysis, Scanning electron microscope, EDX analysis, and density measurements. The gamma-ray shielding properties for the fabricated CuFeNiO ceramics samples were evaluated using the Monte Carlo simulation method. The obtained results show an enhancement in the linear attenuation coefficient for the fabricated ceramics with increasing the insertions of Ni ions within the fabricated samples, where increasing the Ni ions concentration between 0 and 1.19 wt% increases the linear attenuation by between 1.581 and 1.771 cm-1 (at 0.103 MeV), 0.304-0.338 cm-1 (at 0.662 MeV), and 0.160-0.178 cm-1 (at 2.506 MeV), respectively. Simultaneously, the radiation protection efficiency for a 1 cm thickness of the fabricated samples increased between 14.8 and 16.3% with increasing the Ni ions between 0 and 1.19 wt%. Although the Ni doping concentration does not exceed 1.5 wt% of the total composition of the fabricated ceramics, the shielding capacity of the fabricated ceramics was enhanced by more than 11%, along the studied energy interval. Therefore, the fabricated samples can be used in gamma-ray shielding applications.

Monte Carlo Simulation for Development of Diagnostic Multileaf Collimator (진단용 다엽콜리메이터 개발을 위한 몬테칼로 시뮬레이션 연구)

  • Han, Su-Chul;Park, Seungwoo
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.595-600
    • /
    • 2016
  • The diagnostic multileaf collimator(MLC) was designed for patient dose reduction in diagnostic radiography We used monte carlo simulation code (MCNPX, LANL, USA) to evaluate efficiency of shielding material for making diagnostic MLC as preliminary study. The diagnostic radiography unit was designed using SRS-78 program according to tube voltage (80,100,120 kVp) and acquired energy spectrums. The shielding material was SKD11 alloy tool steel that is composed of 1.6% carbon(C), 0.4% silicon(Si), 0.6% manganese (Mn), 5% chromium (Cr), 1% molybdenum(Mo) and vanadium(V). The density of it was $7.89g/cm^3$.Using tally card 6, we calculated the shielding efficiency of MLC according to tube voltage. The results was that 98.3% (80 kVp), 95.7 %(100 kVp), 93.6% (120 kVp). We certified efficiency of diagnostic MLC fabricated from SKD11 alloy steel by monte calro simulation. Based on the results, we designed the diagnostic MLC and will develop the diagnostic MLC for reduction of patient dose in diagnostic radiography.

A GPU-based point kernel gamma dose rate computing code for virtual simulation in radiation-controlled area

  • Zhihui Xu;Mengkun Li;Bowen Zou;Ming Yang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.1966-1973
    • /
    • 2023
  • Virtual reality technology has been widely used in the field of nuclear and radiation safety, dose rate computing in virtual environment is essential for optimizing radiation protection and planning the work in radioactive-controlled area. Because the CPU-based gamma dose rate computing takes up a large amount of time and computing power for voxelization of volumetric radioactive source, it is inefficient and limited in its applied scope. This study is to develop an efficient gamma dose rate computing code and apply into fast virtual simulation. To improve the computing efficiency of the point kernel algorithm in the reference (Li et al., 2020), we design a GPU-based computing framework for taking full advantage of computing power of virtual engine, propose a novel voxelization algorithm of volumetric radioactive source. According to the framework, we develop the GPPK(GPU-based point kernel gamma dose rate computing) code using GPU programming, to realize the fast dose rate computing in virtual world. The test results show that the GPPK code is play and plug for different scenarios of virtual simulation, has a better performance than CPU-based gamma dose rate computing code, especially on the voxelization of three-dimensional (3D) model. The accuracy of dose rates from the proposed method is in the acceptable range.

Gadolinium- and lead-containing functional terpolymers for low energy X-ray protection

  • Zhang, Yu-Juan;Guo, Xin-Tao;Wang, Chun-Hong;Lu, Xiang An;Wu, De-Feng;Zhang, Ming
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4130-4136
    • /
    • 2021
  • By polymerization of gadolinium methacrylate (Gd (MAA)3), lead methacrylate (Pb(MAA)2) and methyl methacrylate (MMA), Gd and Pb were chemically bonded into polymers. The X-ray shielding performance was evaluated by Monte Carlo simulation method, and the results showed that the more metal functional organic monomer, the better the shielding performance of terpolymers. When the X-ray energy is 65 keV, Gd (MAA)3-containing polymers have better shielding performance than Pb(MAA)2-containing polymers. Gd could compensate for the weak absorption region of Pb. Therefore, polymers containing both Gd and Pb enhanced shielding efficiency against X-ray in various low-energy ranges. For obtaining terpolymers with uniform monomer compositions, the relationship between the monomer composition of the terpolymers and the conversion level was optimized by calculating the reactivity ratios. The value of reactivity ratios of r (Gd (MAA)3/Pb(MAA)2), r (Pb(MAA)2/Gd (MAA)3), r (Gd (MAA)3/MMA), r (MMA/Gd (MAA)3), r (Pb(MAA)2/MMA) and r (MMA/Pb(MAA)2) was 0.483, 0.004, 0.338, 2.508, 0.255, 0.029. The terpolymers with uniform monomer composition could be obtained by controlling the monomer compositions or conversion levels. The results can provide new radiation protection materials and contribute to the improvement in nuclear safety.

Evaluation of Radiation Shielding Rate of Lead Aprons in Nuclear Medicine (핵의학과에서 사용하는 납 앞치마의 방사선 차폐율 평가)

  • Han, Sang-Hyun;Han, Beom-Heui;Lee, Sang-Ho;Hong, Dong-Heui;Kim, Gi-Jin
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • Considering that the X-ray apron used in the department of radiology is also used in the department of nuclear medicine, the study aimed to analyze the shielding rate of the apron according to types of radioisotopes, thus ${\gamma}$ ray energy, to investigate the protective effects. The radioisotopes used in the experiment were the top 5 nuclides in usage statistics $^{99m}Tc$, $^{18}F$, $^{131}I$, $^{123}I$, and $^{201}Tl$, and the aprons were lead equivalent 0.35 mmPb aprons currently under use in the department of nuclear medicine. As a result of experiments, average shielding rates of aprons were $^{99m}Tc$ 31.59%, $^{201}Tl$ 68.42%, and $^{123}I$ 76.63%. When using an apron, the shielding rate of $^{131}I$ actually resulted in average dose rate increase of 33.72%, and $^{18}F$ showed an average shielding rate of -0.315%, showing there was almost no shielding effect. As a result, the radioisotopes with higher shielding rate of apron was in the descending order of $^{123}I$, $^{201}Tl$, $^{99m}Tc$, $^{18}F$, $^{131}I$. Currently, aprons used in the nuclear medicine laboratory are general X-ray aprons, and it is thought that it is not appropriate for nuclear medicine environment that utilizes ${\gamma}$ rays. Therefore, development of nuclear medicine exclusive aprons suitable for the characteristics of radioisotopes is required in consideration of effective radiation protection and work efficiency of radiation workers.

Development of a Virtual Frisch-Grid CZT Detector Based on the Array Structure

  • Kim, Younghak;Lee, Wonho
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.1
    • /
    • pp.35-44
    • /
    • 2020
  • Background: Cadmium zinc telluride (CZT) is a promising material because of a high detection efficiency, good energy resolution, and operability at room temperature. However, the cost of CZT dramatically increases as its size increases. In this study, to achieve a large effective volume with relatively low cost, an array structure comprised of individual virtual Frisch-grid CZT detectors was proposed. Materials and Methods: The prototype consisted of 2 × 2 CZTs, a holder, anode and cathode printed circuit boards (PCBs), and an application-specific integrated circuit (ASIC). CZTs were used and the non-contacting shielding electrode method was applied for virtual Frisch-grid effect. An ASIC was used, and the holder and the PCBs were fabricated. In the current system, because the CZTs formed a common cathode, a total of 5 channels were assigned for data processing. Results and Discussion: An experiment using 137Cs at room temperature was conducted for 10 minutes. Energy and timing information was acquired and the depth of interaction was calculated by the timing difference between the signals of both electrodes. Based on obtained three-dimensional position information, the energy correction was carried out, and as a result the energy spectra showed the improvements. In addition, a Compton image was reconstructed using the iterative method. Conclusion: The virtual Frisch-grid CZT detector based on the array structure was developed and the energy spectra and the Compton image were successfully acquired.