• 제목/요약/키워드: Radiation sensor

검색결과 426건 처리시간 0.031초

솔라패널을 이용한 라디오존데 온도센서의 일사보정 (Compensation for The Solar Radiation Effect of Radiosonde's Temperature Sensor Using Solar Panel)

  • 박명석;이진욱;정세진;장재원
    • 대기
    • /
    • 제29권3호
    • /
    • pp.283-294
    • /
    • 2019
  • For the upper air observations, a temperature measurement using radiosonde is a common method, and the compensation of solar radiation effects in the radiosonde temperature sensor is an important factor. In this paper, we present various experiments and compensation methods of the radiosonde temperature sensor to overcome the errors caused by the movement of the radiosonde rotation, etc. The methods and procedures of this study are as follows. First, we used the solar simulator to analyze the temperature variation and solar effect of the temperature sensor in the radiosonde according to the insolation. We also analyzed the temperature variation and solar effect of the temperature sensor according to the incident angle between the solar simulator and radiosonde. Second, we measured and analyzed solar radiation absorbed by solar cells attached to radiosonde. Third, we present combined compensate solution of the first and the second experiment results, to overcome errors caused by insolation effects in the radiosonde temperature sensors. Fourth, we compared that the reference temperature in similar environment with the upper air conditions, to verify the new radiated compensation performance of the radiosonde temperature sensor. Finally, the radiosonde fabricated in this study was raised to the atmosphere, and the laser correction algorithm proposed through experiments was reviewed. As a result of the radiosonde SRS-10 produced in this study, the temperature deviation from Vaisala RS92 was $0.057^{\circ}C$ in nighttime observation, $0.17^{\circ}C$ in daytime observation, It is expected that the GRUAN under WMO will be able to obtain a high test rating of 5.0.

CdTe 멀티에너지 엑스선 영상센서 패키징 기술 개발 (Development of Packaging Technology for CdTe Multi-Energy X-ray Image Sensor)

  • 권영만;김영조;유철우;손현화;김병욱;김영주;최병정;이영춘
    • 한국방사선학회논문지
    • /
    • 제8권7호
    • /
    • pp.371-376
    • /
    • 2014
  • CdTe 멀티에너지 X선 영상센서와 ROIC를 패키징 하기 위한 flip chip bump bonding, Au wire bonding 및 encapsulation 공정조건을 개발하였으며 성공적으로 모듈화 하였다. 최적 flip chip bonding 공정 조건은 접합온도 CdTe 센서 $150^{\circ}C$, ROIC $270^{\circ}C$, 접합압력 24.5N, 접합시간 30s일 때이다. ROIC에 형성된 SnAg bump의 bonding이 용이하도록 CdTe 센서에 비하여 상대적으로 높은 접합온도를 설정하였으며, CdTe센서가 실리콘 센서에 비하여 쉽게 파손되는 것을 고려하여 접합압력을 최소화하였다. 패키징 완료된 CdTe 멀티에너지 X선 모듈의 각각 픽셀들은 단락이나 합선 등의 전기적인 문제점이 없는 것을 X선 3D computed tomography를 통해 확인할 수 있었다. 또한 Flip chip bump bonding후 전단력은 $2.45kgf/mm^2$ 로 측정되었으며, 이는 기준치인 $2kgf/mm^2$ 이상으로 충분한 접합강도를 가짐을 확인하였다.

비파괴 검사 분야의 방사성 동위원소 위치추적을 위한 반도체 화합물의 적용 가능성 연구 (The Study on Applicability of Semi-conductive Compound for Radioactive Source Tracing Dosimeter in NDT Field)

  • 신요한;한무재;정재훈;김교태;허예지;이득희;조흥래;박성광
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.39-44
    • /
    • 2019
  • Co-60 및 Ir-192 등의 방사성 동위원소가 비파괴 검사(Non-Destructive Test; NDT) 등의 분야에서 널리 쓰임에 따라 방사선 안전관리가 매우 중요시되고 있다. 본 연구에서는 요오드화수은(Mercury(II) Iodide; $HgI_2$)의 선원추적 시스템 적용 가능성을 평가하였다. $HgI_2$로 제작된 Unit cell 센서의 신뢰도 검증을 위한 전기적 특성평가를 수행한 후, 방사선에 대한 센서의 위치의존성을 분석하고, Planning system의 선량 분포와 비교하였다. 평가결과, R-sq>0.99 이상의 선형성과 CV<0.015 이하의 재현성을 보이며 신뢰도가 높은 것으로 나타났다. 또한, 위치의존성 평가에서는 센서의 isocenter에서 최댓값이 측정되었으며, 거리에 따라 점진적 감소를 나타냈다. 그러나 Planning system 상의 선량 분포 데이터와는 최대 30%의 차이를 보였는데, 센서는 단일지점으로부터 데이터를 수집하는 Planning system과 달리 면적으로부터 수집하기 때문으로 사료된다.

원자력 및 핵의학 분야용 Total RMS (Radiation Monitoring System)의 설계 (Design of Total RMS(Radiation Monitoring System) for nuclear and nuclear medicine)

  • 고태영;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.158-161
    • /
    • 2017
  • 본 논문에서는 원자력 및 핵의학 분야용 Total RMS(Radiation Monitoring System)를 제안한다. 제안하는 시스템은 Stack Monitor, Area Monitor, Water(Liquid) Monitor 등을 하나의 시스템으로 확장 및 제어할 수 있는 장비로 각 방사선 검출기에서 측정된 신호를 통합 모니터링 할 수 있다. 제안하는 시스템은 해당 방사선을 검출하는 Sensor Module, 방사선 검출 위치에 인접한 곳에서 방사선량을 디스플레이 하는 Display Unit, 검출된 방사선량이 위험 수준에 도달시 경보를 알리는 Alarm Unit, 각 모니터링에서 측정된 방사선량들을 취합하고 저장하여 원격 감시 시스템에 내용을 전달하는 Main Hub, 원격지에서 측정된 방사선량 상태를 일목요연하게 디스플레이 하는 RMS Monitoring Unit 등으로 구성된다. 제안된 원자력 및 핵의학 분야용 Total RMS의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과, 측정 불확도가 8.5%이하로 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.

헤테르접합을 이용한 누설전류 저감을 위한 다층구조의 방사선 검출 물질 개발 (Radiation detector material development with multi-layer by hetero-junction for the reduction of leakage current)

  • 오경민;윤민석;김민우;조성호;남상희;박지군
    • 한국방사선학회논문지
    • /
    • 제3권1호
    • /
    • pp.11-15
    • /
    • 2009
  • 본 연구에서는 헤테로 접합을 이용하여 누설전류를 저감 시키는 기술을 적용하여 Particle-In -Binder을 이용한 방사선 영상 센서의 변환 물질을 개발하였다. 이는 디지털 방사선 영상 검출기의 두 가지 방식 중 하나인 직접방식에 사용되는 핵심 소자로 기존의 비정질 셀레늄(Amorphous Selenium)을 대체하여 더욱 효율이 높은 후보 물질들이 연구되어지는 가운데 태양전지와 반도체 분야에서 이미 많이 사용되어온 이종접합(Hetero junction)을 이용해 누설 전류를 저감 시키는데 그 목적이 있다. 본 연구에서 사용되는 Particle-In -Binder 제작 방법은 검출 물질 제작이 용이하고 높은 수율과 대면적의 검출기 제작에 적합하나 높은 누설 전류가 의료 영상 시스템에 있어서 문제가 되어 오고 있다. 이러한 단점을 보완하기 위해 다층 구조를 이용하여 누설 전류를 저감시킨다면 Particle-In -Binder을 이용하여 간편하게 향상된 효율의 디지털 방사선 검출기를 제작 할 수 있다고 사료 되어 진다. 본 연구에서는 누설전류 및 민감도, 그리고 선형성에 대한 전기적 신호를 측정하여 제작된 다층 구조의 방사선 검출 물질의 특성 평가가 이루어 졌다.

  • PDF

Development of a Breath Control Training System for Breath-Hold Techniques and Respiratory-Gated Radiation Therapy

  • Hyung Jin Choun;Jung-in Kim;Jong Min Park;Jaeman Son
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.136-141
    • /
    • 2022
  • Purpose: This study aimed to develop a breath control training system for breath-hold technique and respiratory-gated radiation therapy wherein the patients can learn breath-hold techniques in their convenient environment. Methods: The breath control training system comprises a sensor device and software. The sensor device uses a loadcell sensor and an adjustable strap around the chest to acquire respiratory signals. The device connects via Bluetooth to a computer where the software is installed. The software visualizes the respiratory signal in near real-time with a graph. The developed system can signal patients through visual (software), auditory (buzzer), and tactile (vibrator) stimulation when breath-holding starts. A motion phantom was used to test the basic functions of the developed breath control training system. The relative standard deviation of the maxima of the emulated free breathing data was calculated. Moreover, a relative standard deviation of a breath-holding region was calculated for the simulated breath-holding data. Results: The average force of the maxima was 487.71 N, and the relative standard deviation was 4.8%, while the average force of the breath hold region was 398.5 N, and the relative standard deviation was 1.8%. The data acquired through the sensor was consistent with the motion created by the motion phantom. Conclusions: We have developed a breath control training system comprising a sensor device and software that allow patients to learn breath-hold techniques in their convenient environment.

원전 무선 센서 네트워크에 적합한 클러스터 헤드 체인 라우팅 프로토콜 (Cluster Head Chain Routing Protocol suitable for Wireless Sensor Networks in Nuclear Power Plants)

  • 정성민
    • 디지털산업정보학회논문지
    • /
    • 제16권2호
    • /
    • pp.61-68
    • /
    • 2020
  • Nuclear power plants have a lower cost of power generation, and they are more eco-friendly than other power generation plants. Also, we need to prepare nuclear plant accidents because of their severe damage. In the event of a safety accident, such as a radiation leak, by applying a wireless sensor network to a nuclear power plant, many sensor nodes can be used to monitor radiation and transmit information to an external base station to appropriately respond to the accident. However, applying a wireless sensor network to nuclear power plants requires routing protocols that consider the sensor network size and bypass obstacles such as plant buildings. In general, the hierarchical-based routing protocols are efficient in energy consumption. In this study, we look into the problems that may occur if hierarchical-based routing protocols are applied to nuclear power plants and propose improved routing protocols to solve these problems. Simulation results show that the proposed routing protocol is more effective in energy consumption than the existing LEACH protocol.

Electrochemical gas sensor based on Pt-Ru-Mo/MWNT electrocatalysts and vinyl ionic liquids as electrolyte

  • Ju, Dong-Woo;Choi, Seong-Ho
    • 분석과학
    • /
    • 제28권1호
    • /
    • pp.8-16
    • /
    • 2015
  • We prepared a novel electrochemical gas sensor (EG sensor) based on interdigitated electrode (IDE) coated with vinyl ionic liquids (ILs) as electrolyte and Pt-Ru-Mo/MWNT electrocatalysts for occurring redox-active of CNCl gas. The vinyl ILs such as 1-butyl-3-(vinylbenzyl)imidazolium chloride, $[BVBI]^+Cl^-$, and 3-hexyl-1-vinylimidazolium bromide, $[HVI]^+Br^-$, were synthesized by $SN_2$ reaction in order to use electrolyte. The Pt-Ru-Mo/MWNT electrocatalysts were also prepared by one-step radiation-induced reduction of metal ions in the presence of MWNTs as supports. The fabricated EG sensor with vinyl ILs electrolyte was evaluated through optical microscopy (OM), scanning electron microscopy (SEM), and atomic force microscopy (AFM). The prepared EG sensor is clearly detected over 2.0 ppm CNCl gas and is exhibited a liner relationship between current and concentration over a region of 10-100 ppm.

적외선 감지 센서를 이용한 점 용접부의 검사 (Inspection of the spot welding using IR sensor)

  • 임대철;박인태;강형식;권대갑
    • 한국정밀공학회지
    • /
    • 제16권1호통권94호
    • /
    • pp.132-140
    • /
    • 1999
  • This paper suggests a monitoring method for the pulsed laser spot welding of the thin metal sheets using a point IR(InfraRed) sensor. A new criterion was introduced and the experimental results guaranteed the efficiency. The ideal radiation feature was derived from the mathematical model and was simulated. The radiation feature is robust to withstand the change of measuring condition and can be used to detect the absorbed laser energy. In an experiment, the radiation feature was examined for the differect laser energy. The pulse width and the laser power was variated and the radiation feature was examined. In the other experiment, the relationship between the weld strength and radiation feature was examined. Artificial Neural Network(ANN) was employed to find out the relationship. The correlation coefficient between the real strength and the estimated strength is high as 0.94 and the mean square error is low as 0.64 kgf learned parts. Another group of the welds was used to appraise the learning efficiency. The correlation coefficient between the measured and the estimated weld strength is high as 0.91.

  • PDF

Radiation Measurement of a Operational CANDU Reactor Fuel Handling Machine using Semiconductor Sensors (ICCAS 2003)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Yang-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1220-1224
    • /
    • 2003
  • In this paper, we measured the radiation dose of a fuel handling machine of the CANDU type Wolsong nuclear reactor directly during operation, in spite of the high radiation level. In this paper we will describe the sensor development, measurement techniques, and results of our study. For this study, we used specially developed semiconductor sensors and matching dosimetry techniques for the mixed radiation field. MOSFET dosimeters with a thin oxide, that are tuned to a high dose, were used to measure the ionizing radiation dose. Silicon diode dosimeters with an optimum area to thickness ratio were used for the radiation damage measurements. The sensors are able to distinguish neutrons from gamma/X-rays. To measure the radiation dose, electronic sensor modules were installed on two locations of the fuel handling machine. The measurements were performed throughout one reactor maintenance cycle. The resultant annual cumulative dose of gamma/X-rays on the two spots of the fuel handling machine were 18.47 Mrad and 76.50 Mrad, and those of the neutrons were 17.51 krad and 60.67 krad. The measured radiation level is high enough to degrade certain cable insulation materials that may result in electrical insulation failure.

  • PDF