• Title/Summary/Keyword: Radiation sensor

Search Result 427, Processing Time 0.022 seconds

Analysis of Open-loop Antenna for Moisture Sensor Using the Moment Methods (모멘트 법을 이용한 수분센서용 개 루우프 안테나의 해석)

  • 정주수
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.86-92
    • /
    • 1999
  • This paper proposed a small type ofen-loop antenna model for the moisture sensor, and its operating characteristics were analyzed numerically using the moment methods. The numerical analysis results through the moment methods showed that this antenna was able to match the input impedance to 50$\Omega$ by changing parameters of the antenna in the frequency range from 300MHz to 500MHz. The gain of antenna was obtained about 2.5dBd. This antenna proposed in this paper showed not only the radiation pattern characteristics of the uniform distribution toward the axial direction above the antenna, but also the narrowband resonant characteristics. Thus we can propose that the antenna be more suitable for the moisture sensor.

  • PDF

Micro-scale Thermal Sensor Manufacturing and Verification for Measurement of Temperature on Wafer Surface

  • Kim, JunYoung;Jang, KyungMin;Joo, KangWo;Kim, KwangSun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.4
    • /
    • pp.39-44
    • /
    • 2013
  • In the semiconductor heat-treatment process, the temperature uniformity determines the film quality of a wafer. This film quality effects on the overall yield rate. The heat transfer of the wafer surface in the heat-treatment process equipment is occurred by convection and radiation complexly. Because of this, there is the nonlinearity between the wafer temperature and reactor. Therefore, the accurate prediction of temperature on the wafer surface is difficult without the direct measurement. The thermal camera and the T/C wafer are general ways to confirm the temperature uniformity on the heat-treatment process. As above ways have limit to measure the temperature in the precise domain under the micro-scale. In this study, we developed the thin film type temperature sensor using the MEMS technology to establish the system which can measure the temperature under the micro-scale. We combined the experiment and numerical analysis to verify and calibrate the system. Finally, we measured the temperature on the wafer surface on the semiconductor process using the developed system, and confirmed the temperature variation by comparison with the commercial T/C wafer.

Quantitative Analysis for Digital Intraoral Sensor (구강 내 촬영용 센서의 정량적 평가)

  • Jung, Jae-Ho;Jung, Jae-Eun;Kang, Hee-Doo;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.109-114
    • /
    • 2009
  • Carried out an experiment for quantitative evaluation about intraoral sensor among oral dental imaging equipments in PACS environment. For evaluation, testing environment & evaluation criteria are established that refer to the 'IEC 62220-1-2' and experimented with set up the standard radiation penetration that correspond with RQA-3(IEC 61267). Results of experiments using the image J, derived the ESF(edge spread function), LSF (line spread function) and calculated the MTF(modulation transfer function) finally. As a result, the MTF that 0.1, 0.2sec are 10% about 10 lp/mm and 0.32 sec is the 10% about 9 lp/mm in level represents the value of the MTF. Change of scan condition in dental environmental, according to the MTF value taken note that no changes can be seen enough. However, the dimensions of each other size $1(1200{\times}1600)$, size $2(1440{\times}1920)$ intraoral sensors for 3 lp/mm, respectively 40%, 90% of the note might have been the difference between the value of MTF, in accordance with standard sensors might note differences could be observed.

  • PDF

Interpretation of Physical Properties of Marine Sediments Using Multi­Sensor Core Logger (MSCL): Comparison with Discrete Samples

  • Kim, Gil-Young;Kim, Dae-Choul
    • Journal of the korean society of oceanography
    • /
    • v.38 no.4
    • /
    • pp.166-172
    • /
    • 2003
  • Multi­Sensor Core Logger (MSCL) is a useful system for logging the physical properties (compressional wave velocity, wet bulk density, fractional porosity, magnetic susceptibility and/or natural gamma radiation) of marine sediments through scanning of whole cores in a nondestructive fashion. But MSCL has a number of problems that can lead to spurious results depending on the various factors such as core slumping, gas expansion, mechanical stretching, and the thickness variation of core liner and sediment. For the verification of MSCL data, compressional wave velocity, wet bulk density, and porosity were measured on discrete samples by Hamilton Frame and Gravimetric method, respectively. Acoustic impedance was also calculated. Physical property data (velocity, wet bulk density, and impedance) logged by MSCL were slightly larger than those of discrete sample, and porosity is reverse. Average difference between MSCL and discrete sample at both sites is relatively small such as 22­24 m/s in velocity, $0.02­-0.08\;g/\textrm{cm}^3$ in wet bulk density, and 2.5­2.7% in porosity. The values also show systematic variation with sediment depth. A variety of factors are probably responsible for the differences including instrument error, various measurement method, sediment disturbance, and accuracy of calibration. Therefore, MSCL can be effectively used to collect physical property data with high resolution and quality, if the calibration is accurately completed.

Simulation and design of individual neutron dosimeter and optimization of energy response using an array of semiconductor sensors

  • Noushinmehr, R.;Moussavi zarandi, A.;Hassanzadeh, M.;Payervand, F.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.293-302
    • /
    • 2019
  • Many researches have been done to develop and improve the performance of personal (individual) dosimeter response to cover a wide of neutron energy range (from thermal to fast). Depending on the individual category of the dosimeter, the semiconductor sensor has been used to simplify and lightweight. In this plan, it's very important to have a fairly accurate counting of doses rate in different energies. With a general design and single-sensor simulations, all optimal thicknesses have been extracted. The performance of the simulation scheme has been compared with the commercial and laboratory samples in the world. Due to the deviation of all dosimeters with a flat energy response, in this paper, has been used an idea of one semi-conductor sensor to have the flat energy-response in the entire neutron energy range. Finally, by analyzing of the sensors data as arrays for the first time, we have reached a nearly flat and acceptable energy-response. Also a comparison has been made between Lucite-PMMA ($H_5C_5O_2$) and polyethylene-PE ($CH_2$) as a radiator and $B_4C$ has been studied as absorbent. Moreover, in this paper, the effect of gamma dose in the dosimeter has been investigated and shown around the standard has not been exceeded.

Solar Ultraviolet Irratiance Incident on a Horizontal Surface at Taegu in Korea During 1995-1998 : (II) Ultraviolet-B

  • Suh, Kyehong
    • Journal of Photoscience
    • /
    • v.6 no.1
    • /
    • pp.5-6
    • /
    • 1999
  • Solar ultraviolet-B (UV-B) irradiances incident on a horizantal surface at Taegu of Korea during 1995-1998 were calculated with 5 min averges of measuremets taken every 30 seconds by a broadband UV-B sensor. The maximum and minimum of monthly averages of daily UV-B dose were 15.89 KJ m-2 day-1 in April and 3.91KJm-2 day-1 on May 22, 1998 and 1.230W m-2 at 12 : 45, July 13, 1998, respectively. Increasing trend in annual maximum of instantaneous UV-B radiation was averaged to 12.0% per year during 1995-1998 of observation period.

  • PDF

Evaluation of IMG level 2 data using GTS

  • Tokunaga, Mitsuharu
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.242-245
    • /
    • 1998
  • Interferometric Monitor for Greenhouse Gases (IMG) is a sensor to monitor the earth's radiation balance, the temperature profile of the atmosphere, the temperature of the earth's surface, and physical properties of clouds, and was loaded on ADEOS satellite. In this paper, we estimated IMG level 2 data by comparing with a Clobal Telecommunications System data (GTS). The IMG level 2 data over sea without cloud cover gave good agreement with the value that had been obtained by buoy and sonde.

  • PDF

Simulation of magnetostrictive Terfenol-D rod dynamics using a coupled FE-BEM

  • Jarng, Soon-Suck
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.298-307
    • /
    • 1999
  • This paper describes the application of the coupled FE-BEM (finite element-boundary element method) for the numerical harmonic analysis of the linear dynamic behaviour of a magnetostrictive Terfenol-D rod in water. The magnetostrictive rod is three-dimensionally simulated to transduce applied electric current in a helical coil around the rod to mechanical displacement. The theoretical derivation of the magnetostrictive matrix equation is described in detail. The steady-state resonance response of the displacement is shown. In addition, the directivity pattern and the radiation impedance are also shown.

  • PDF

A Study on the induced Current of Electro Explosive Device Bridge Wire under Electromagnetic Field (전자파환경에서 EED에 유기되는 전류에 관한 연구)

  • 김응조
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.116-122
    • /
    • 2002
  • Electro Explosive Devices can be susceptible to electromagnetic interference. When these components are exposed to external electromagnetic fields, it may cause to induce sufficient current to generate enough heat for an inadvertent detonation. It is almost impossible to monitor the event of firing throughout the electromagnetic environment test. The survivability of EED for hazards of electromagnetic radiation is investigated. A fiber optic sensor is installed near the bridge wire after removing explosive material in order to measure the induced current on the bridge wire. The length of lead-wire of the EED fabricated is around 15 cm.