• 제목/요약/키워드: Radiation quality

검색결과 1,598건 처리시간 0.039초

부산시내 지하생활권의 공기오염도와 온열인자에 관한 조사연구 (A Study on Air Pollution and Thermal Factors in Underground Shopping Center of Pusan Area)

  • 최성용;문덕환;이종태;송인혁;이채언;이승민
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권3호
    • /
    • pp.505-516
    • /
    • 1994
  • For the purpose of preparing the fundamental data on air pollution in underground shopping center and also contributing to the health improvement of residents, the authors measured the level of $SO_2,\;NO_2,\;TSP,\;CO,\;CO_2$ and also some related factors as air temperature, air movement, relative humidity and mean radiation temperature at inside and outside of underground shopping center in Pusan from January to February and from July to August 1994. The results were as follows : 1. The mean concentration of CO within the underground shopping center was $3.1{\pm}1.3ppm$ in winter and $2.1{\pm}0.9ppm$ in summer. There was a negative correlation (p<0.01) between inner CO concentration and temperature in summer and no correlation between inner CO concentration and outer CO concentration in underground shopping center 2. The mean concentration of COE within the underground shopping center was $876{\pm}353ppm$ in winter and $757{\pm}125ppm$ in summer. There was a negative correlation (p<0.01) between inner $CO_2$ concentration and air movement in summer and positive correlation (p<0.05) between inner $CO_2$ concentration and outer $CO_2$ concentration in underground shopping center. 3. The mean concentration of $SO_2$ within a underground shopping center was $0.036{\pm}0.019ppm$ in winter and $0.040{\pm}0.013ppm$ in summer. There was a positive correlation(p<0.01) between inner $SO_2$ concentration and temperature in summer and positive correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in summer and winter in underground shopping center. 4. The mean concentration of $NO_2$ within a underground shopping center was $0.052{\pm}0.038ppm$ in winter and $0.042{\pm}0.016ppm$ in summer. There was a no correlation between inner $SO_2$ concentration and thermal factors in summer and winter and low correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in underground shopping center 5. The mean concentration of TSP within a underground shopping center was $430{\pm}214{\mu}g/m^3$ in winter, $366{\pm}73{\mu}g/m^3$ in summer, and very in excess of the atmospheric environmental quality standards of Korea ($150{\mu}g/m3{\downarrow}$). There was low correlation between inner TSP concentration and temperature in summer and high correlation between inner TSP concentration and outer TSP concentration in underground shopping center.

  • PDF

블라인드 내장형 창호시스템의 에너지 성능 및 경제성 평가에 관한 연구 (Study on Energy Performance And Economic Evaluation of Windows System with Built-in Type Blinds)

  • 조원화;임남기
    • 한국건축시공학회지
    • /
    • 제10권2호
    • /
    • pp.97-104
    • /
    • 2010
  • 본 연구에서는 전열해석 프로그램인 피지벨(PHYSIBEL)을 사용하여 블라인드 내장형 창호시스템의 일사차단성능 및 단열성능에 따른 에너지 성능을 평가하였다. 피지벨 해석시 창호별 구성 재료의 열적특성과 해석조건을 결정하기 위해서 Mock-up시험을 실시하였으며, 컴퓨터 시뮬레이션을 통한 결과를 바탕으로 공동주택 기준층 1개 세대(33평형)를 대상으로 연간에너지 소비특성, 연간전열량, 연간 냉난방 비용을 분석하였다. 실험결과, 연간전열량은 일반 창호시스템 대비 블라인드 내장형 창호시스템에서 블라인드를 올린 경우 냉방시 10%, 난방시 11% 절감할 수 있으며, 블라인드를 내린 경우 냉방시 25%, 난방시 30%정도를 절감할 수 있는 것으로 나타났다. 블라인드 내장형 창호시스템의 냉 난방 부하 절감량은 일반 창호시스템에 비해 냉방시 283.3KWh, 난방시 76.3KWh 로 냉 난방 에너지 절감효과는 단위세대당 359.6KWh 절감시킬 수 있는 것으로 나타났으며, 이것은 단위세대당 연간 에너지원단위(TOE) 약 0.078toe, 이산화탄소톤($tCO_2$) $0.16tCO_2$을 절감시킬 수 있어 온실가스 저감에도 유리할 것으로 판단된다. 또한, 블라인드 내장형 창호시스템의 냉 난방비용 절감액은 일반창호시스템과 비교하여 연간 냉방비용 10만원, 난방비용 5만원으로 연간 냉 난방 비용을 약 15만원 정도 절감시킬 수 있는 것으로 나타났다.

부산지역 의료기관의 흉부촬영 조건과 피폭선량에 관한 조사연구 (A Study on Radiographical Conditions and Exposure Doses During Chest Radiography at Medical Facilities in Pusan)

  • 전성오;조영하
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.49-55
    • /
    • 1997
  • This study was carried out to investigate radiographical and operating conditions of X-ray units and exposure doses to patients during chest radiography, so that the results could provide basic data used for reducing the exposure dose and for providing the diagnostic information with better quality. The conditions and exposure doses of 100 X-ray units mainly used for chest radiography were examined and also 100 radiological technologists mainly handling those apparatus at 76 medical facilities in Pusan were surveyed using a questionnaire from October 1 to December 31 in 1995. The following results were obtained from the study : 1. It was found that most units were capable of taking a high tube voltage radiography by showing 67% of the units equipped with the maximum tube voltage of 150 kV, 94% with more than 500 mA for the rating capacity and 85% with the full wave type of a signal phase. 2. For actual chest radiographical conditions, however, 80% of the units were operated at $60{\sim}100\;kVp$ and only 14% at 100 kVp and over for the high tube voltage. 3. The average exposure time was less than 0.1 second, and eighty four percent of the units adapted the X-ray tube currents ranging from 200 to 300 mA, 80% the focus-film distances between 180 and 210 cm, and 63% the focus sizes of more than 2.0 mm. 4. Most units(98%) employed additional filters made of aluminum, 75% the thickness of filters less than 2.0 mm, and only 2 units the compound filters. 5. Ortho chromatic system was only adopted in 13% of screen film system for the units, and 73% used the grid ratio at 8 : 1 for the low tube voltage during chest radiography. 6. The average exposure dose of all X-ray units during chest radiography was $371\;{\mu}Sv$ with a difference of about 16 times between the minimum to the maximum, and $386\;{\mu}Sv$ both at hospitals and at health centers, followed by $380\;{\mu}Sv$ at general hospitals and $263\;{\mu}Sv$ at university hospitals without showing any statistically significant differences. In conclusion, since patients during chest radiography at medical facilities in Pusan exposed to high levels of radiation, it is recommended that appropriate added filters and grids necessary for the high tube voltage radiography and high-speed screen systems should be adopted and used as soon as possible in order to reduce exposure dose to the patients.

  • PDF

가중 퍼텐셜에 기초한 CT용 CdZnTe 소자 설계 (CdZnTe Detector for Computed Tomography based on Weighting Potential)

  • 임현종;박찬선;김정수;김정민;최종학;김기현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.35-42
    • /
    • 2016
  • CdZnTe(CZT)는 상온에서 동작 가능한 II-VI족 기반의 화합반도체로 CT (Computed Tomography)나 맘모그라피 (mammography)용 검출기로 적용하면, 환자의 피폭선량을 저감할 수 있는 획기적인 소자재료이다. 픽셀(pixel)과 픽셀 피치(pixel pitch)에 따라 X선 변환효율과 신호 교차 (cross-talk)에 영향을 주어 영상 품질이 결정된다. 가중 퍼텐셜 (weighting potential)은 전극의 위치와 형태에 의해서 결정지어지는 가상 퍼텐셜로 Poisson's 방정식의 해를 통해서 구할 수 있다. 본 연구에서는 컴퓨터 기반의 모의실험을 통해 가상 퍼텐셜을 계산하고, 전하유도효율(CIE; charge induction efficiency)과 신호교차를 고려하여 CT용 센서에 적합한 픽셀을 결정하고자 하였다. 모의실험에서 1 mm의 픽셀피치와 2 mm 두께의 CZT를 가정하여, 다양한 픽셀과 픽셀피치를 설정 후 가중 퍼텐셜을 계산하였다. 픽셀의 크기가 $750{\mu}m$이고 픽셀간의 간격이 $250{\mu}m$일 때 최대 전하유도 효율과 최소 신호교차를 나타내었다.

한국표준의료행위 분류체계 개발 (The Development of Classification System of Medical Procedures in Korea)

  • 박형욱;손명세;김한중;박은철;유승흠
    • Journal of Preventive Medicine and Public Health
    • /
    • 제29권4호
    • /
    • pp.877-897
    • /
    • 1996
  • In recent years, the Korean Medical Association has undertaken the feat of establishing the Korean Standard Terminology of Medical Procedures with the dedicated help of 32 medical academic societies. However, because the project is being conducted by several different circles, it has yet to see a clear system of classification. This thesis, therefore, proposes the three principles of scientific properties, usefulness and ideology as the basis for classification system and has developed the Classification System of Medical Procedures in Korea upon their foundation. The methodology and organization of this thesis as follows. First, by adopting scientific classification system of Feinstein(1988), an analysis of the classification systems of the medical procedures in the United States, Japan, Taiwan, WHO was carried out to reveal the framework and the basic principles in each system. Second, the direction of classification system has been constructed by applying the normative principle of medical field in order to show the future direction of the medical field and realize its ideology. Third, a finalized framework for the classification system will be presented as based on the direction of classification system. Of the three basis principles mentioned above, the analysis on the principles of usefulness was left out of this thesis due to the difficulty of establishing specific standards of analysis. The results of the study are as follows. The overall structure of the thesis is aimed at showing the 'Prevention-Therapy-Rehabilitation' quality of comprehensive health care and consists of six chapters; I. Prevention and Health Promotion II. Evaluation and Management III. Diagnostic Procedures IV. Endoscopy V. Therapeutic Procedures VI. Rehabilitation Chapter three Diagnostic Procedures is divided into four parts : Functional Diagnosis, Visual Diagnosis, Pathological Diagnosis, Biopsy and Sampling. Chapter five Therapeutic Procedures is divided into Psychiatry, Non-Invasive Therapy, Invasive Therapy, Anaesthesia and Radiation Oncology. Of these sub-divisions, Functional Diagnosis, Biopsy and Sampling, Endoscopy and Invasive Therapy employs the anatomical system of classification. On the other hand, Visual Diagnosis, Pathological Diagnosis, Anesthesia and Diagnostic Radiology, namely those divisions in which there is little or no overlapping in services with other divisions, used the classification system of its own division. The classification system introduced in this thesis can be further supplemented through the use of the cluster analysis by incorporating the advice and assistance of other specialists.

  • PDF

열풍건조와 복합건조로 제조한 방울토마토(Solanum lycopersicum var. cerasiforme)의 이화학특성에 관한 비교연구 (Comparative study on physicochemical properties of cherry tomato (Solanum lycopersicum var. cerasiforme) prepared using hot-air and combined drying)

  • 강은정;박예주;박성수;이재권
    • 한국식품과학회지
    • /
    • 제50권3호
    • /
    • pp.339-343
    • /
    • 2018
  • 과열증기와 열풍(과열증기/열풍건조) 또는 원적외선(과열증기/원적외선건조)으로 복합건조한 방울토마토의 이화학특성을 상응하는 열풍건조 토마토와 비교하여, 복합건조가 건조토마토의 품질특성에 미치는 영향을 조사하였다. 방울토마토의 수분함량 85.10%는 열풍건조, 과열증기/열풍 또는 원적외선의 복합건조에 따라 15.98, 22.94 및 23.08%로 각각 감소하였으며, 열풍건조와 달리 복합건조 토마토는 중간수분식품의 수분함량에 해당하는 반건조상태를 나타내었다. 건조토마토의 수축도와 표면색상은 건조 방법에 관계없이 유사하였으나, 열풍건조 토마토는 복합건조에 비해 단단한 텍스처와 낮은 풍미를 나타내었다. 방울토마토의 아스코브산 함량(260.1 mg/100 g)은 열풍건조에서 77.6 mg/100 g으로 최대 감소를 보인 반면, 복합건조의 경우에는 과열증기/열풍건조 120.8 mg/100 g, 과열증기/원적외선건조 185.2 mg/100 g으로 낮은 손실을 나타내었다. 리코펜 함량은 열풍건조, 과열증기/열풍 또는 원적외선의 복합건조에서 각각 5.55, 5.81 및 8.53 mg/100 g으로서, 대조구 대비 77, 76 및 64%의 높은 손실률을 나타내었는데, 이는 건조공정 이외에 시료의 탈피와 동결건조 과정에서 리코펜이 유실, 손상되었기 때문으로 추정된다. 그러나 건조방법에 따른 리코펜의 손실 양상을 고려할 때, 리코펜 손실은 과열증기/원적외선의 복합건조에서 가장 낮은 것으로 판단된다. 한편 수분흡수력은 모든 수침시간에서 복합건조시료가 열풍건조에 비해 현저하게 높았으며, 특히 과열증기/원적외선건조의 경우 가장 빠른 수화복원력을 나타내었다. 이상의 결과에 따라 방울토마토의 건조는 외관, 유용성분의 손실률과 수화복원력의 관점에서 과열증기처리 후 원적외선으로 건조하는 복합건조가 열풍건조에 비해 효율적인 것으로 판단된다.

CT 촬영 조건에 따른 PET 영상의 변화 (Change of PET Image According to CT Exposure Conditions)

  • 박재윤;김정훈;이용기
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.473-479
    • /
    • 2019
  • 다양한 촬영 조건의 CT 감쇠 지도가 PET 영상에 영향을 미치는지 알아보기 위하여 다양한 kVp와 mA조건에서 Uniformity phantom 영상의 신호 강도(SI; Signal Intensity)와 표준 섭취율 계수(SUV; Standardized Uptake Value)를 측정하고, CTDI (Computed Tomography Dose Index)를 통해 각 조건에 따른 피폭선량을 측정하였다. 또한 동일한 조건에서 Resolution phantom의 반치폭(FWHM; Full Width at Half Maximum)을 측정하여 CT의 kVp와 mA에 따른 PET 영상의 화질 변화에 대하여 정량적으로 알아보고자 하였다. 연구 결과, CT의 촬영 조건은 PET 영상에는 영향을 주지 않는 것으로 나타났으나, CT의 촬영 조건이 감소하게 되면 방사선 피폭이 감소하게 되지만 영상에 영향을 미치게 되므로 향후 진단이 가능한 CT 화질을 유지하면서 방사선 피폭을 최소화할 수 있는 양전자 방출 단층 촬영(PET/CT; Positron Emission Tomography / Computed Tomography)의 촬영 조건에 대한 연구가 지속적으로 되어야 할 것이다.

기상 데이터 기반 감귤 당도 예측 인공지능 모델 개발 (Development of Artificial Intelligence Model for Predicting Citrus Sugar Content based on Meteorological Data)

  • 서동민
    • 한국콘텐츠학회논문지
    • /
    • 제21권6호
    • /
    • pp.35-43
    • /
    • 2021
  • 감귤의 품질은 일반적으로 당도와 산도로 결정된다. 특히, 당도는 감귤의 맛을 결정하기 때문에 매우 중요한 요소이다. 현재 농가에서 가장 많이 사용하는 감귤 당도 측정 방법은 휴대용 착즙당도계 및 비파괴당도계로 측정하는 방식이다. 이 방법은 개인이 손쉽게 측정 가능한 방법이지만, 감귤농협 정식기계보다 당도수치의 정확성이 떨어지며 특히 0.5 Brix 이상 오차 차이가 발생해 현장에서 사용하기에는 아직 많이 부족하다. 또한, 현재 시점의 측정이지 예측 측정이 아니다. 그래서 본 논문에서는 기존 수집된 감귤 당도 값과 기상 데이터(평균 온도, 습도, 강우량, 일사량, 평균 풍속)을 기반으로 측정되지 않은 날짜의 감귤 당도를 0.5 Brix 이하 오차범위 내에서 예측하는 AI 모델을 제안했다. 또한, 성능평가를 통해 제안하는 예측 모델이 제주 성산 지역에 대해서는 절대 평균 오차가 0.1154, 하원 지역에 대해서는 0.1983인 것을 확인했다. 마지막으로 제안한 모델은 0.5 Brix 이하 오차 차이를 지원하며, 예측 측정을 지원하는 기술이기에 그 활용성에 있어 진보성이 매우 높을 것으로 기대된다.

논벼에서 관측된 태양 유도 엽록소 형광 자료: 나주에서 2020년 6월 10일부터 10월 5일까지 (Sun-induced Fluorescence Data: Case of the Rice Paddy Field in Naju)

  • 류재현;장선웅;김현기;문현동;신서호;이양원;조재일
    • 한국농림기상학회지
    • /
    • 제23권1호
    • /
    • pp.82-88
    • /
    • 2021
  • 원격탐사 기법을 이용하여 산출된 태양 유도 엽록소 형광(Sun-Induced Fluorescence, SIF)을 통해 식생의 광합성 효율 및 스트레스 상태를 이해하기 위한 노력이 세계적으로 진행되고 있다. 최근 SIF 관측을 위한 광학 기기 개발과 SIF 산출 방법론이 정립되고 있으나 아직 국내에서는 SIF 관측이 드물며 관측 자료의 수도 적다. 본고에서는 나주에서 2020년 6월 10일부터 2020년 10월 5일까지 벼 생육기간 동안 광학 기기를 이용하여 관측된 SIF 자료를 공개하였다. SFM 방법과 iFLD 방법으로 O2A과 O2B 흡수 대역의 SIF를 산출하였으며, 광합성 유효 복사량에 대한 정보도 제공하였다. 또한, 태양천정각, 센서의 광 포화상태, 관측 순간의 태양광의 급격한 변화, 태양광 정반사 영향 등을 고려하여 품질이 낮은 SIF 자료를 필터링하였다. 본 자료를 통해 연구자들이 SIF에 대한 이해를 높이고, 제안된 SIF 자료 필터링 방법으로 SIF 산출물 품질관리에 도움이 될 것으로 기대한다.

Effect of Light Receiving rate on Growth and Quality of Ginseng Cultivated in Plastic House

  • Sang Young Seo;Jong hyeon Cho;Chang Su Kim;Hyo Jin Kim;Min Sil An;Du Hyeon Yoon
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2020년도 추계국제학술대회
    • /
    • pp.62-62
    • /
    • 2020
  • Ginseng is a shade-plant cultivated using shading facilities. However, at too low light levels, root growth is poor, and at high light levels, the destruction of chlorophyll reduces the photosynthesis efficiency due to leaf burn and early fall leaves. The ginseng has a lightsaturation point of 12,000~15,000 lux when grown at 15 to 20℃ and 9,500 lux at 25℃. This study was conducted to select the optimal light intensity of 3-year-old ginseng grown in blue-white film plastic house. The seeds were planted in the blue-white film plastic house with different light receiving rate (March 17, 2020). Between April and September, the average air temperature in the house was 20.4-20.7℃. Average soil temperature was 18.3℃-18.5℃. The chemical properties of the test soil was as follows. The pH level was 7.0-7.4, EC was 0.5-0.6 dS/m, OM was at the levels of 33.6-37.7 g/kg, P2O5 was 513.0-590.8 mg/kg, slightly higher than the allowable 400 mg/kg. The amount of light intensity, illuminance, and solar radiation in the blue-white film house was increased as the light-receiving rate increased and the amount of light intensity was found to be 9-14% compared to the open field, 8-13% illuminance and 9-14% solar irradiation respectively. The photosynthesis rate was the lowest at 3.1 µmolCO2/m2/s in the 9% light blue-white plastic house and 4.2 and 4.0 µmolCO2/m2/s in the 12% and 14% light blue-white plastic house, respectively. These results generally indicate that the photosynthesis of plants increases with the amount of light, but the ginseng has a lower light saturation point at high temperatures, and the higher the amount of light, the lower the photosynthetic efficiency. The SPAD (chlorophyll content) value decreased as the increase of light-receiving rate, and was the highest at 32.7 in 9% light blue-white plastic house. Ginseng germination started on April 11 and took 13-15 days to germinate. The overall germination rate was 82.9-85.8%. The plant height and length of stem were long in the 9% light-receiving plastic house. The diameter of stem was thick in the 12-14% light-receiving plastic house. In the 12% and 14% light-receiving plastic house, the length and diameter of taproot was long and thick, so the fresh weight of root per plant was 20 g or more, which was heavier than 16.9 g of the 9% light-receiving plastic house. The disease incidence (Alternaria blight, Gray mold and Damping-off etc.) rate were 0.9-2.7%. The incidence of Sclerotinia rot disease was 7.5-8.4%, and root rot was 0-20.0%. The incidence ratio of rusty root ginseng was 34.4-38.7% level, which was an increase from the previous year's 15% level.

  • PDF