• Title/Summary/Keyword: Radiation pressure

Search Result 681, Processing Time 0.026 seconds

Classification Abnormal temperatures based on Meteorological Environment using Random forests (랜덤포레스트를 이용한 기상 환경에 따른 이상기온 분류)

  • Youn Su Kim;Kwang Yoon Song;In Hong Chang
    • Journal of Integrative Natural Science
    • /
    • v.17 no.1
    • /
    • pp.1-12
    • /
    • 2024
  • Many abnormal climate events are occurring around the world. The cause of abnormal climate is related to temperature. Factors that affect temperature include excessive emissions of carbon and greenhouse gases from a global perspective, and air circulation from a local perspective. Due to the air circulation, many abnormal climate phenomena such as abnormally high temperature and abnormally low temperature are occurring in certain areas, which can cause very serious human damage. Therefore, the problem of abnormal temperature should not be approached only as a case of climate change, but should be studied as a new category of climate crisis. In this study, we proposed a model for the classification of abnormal temperature using random forests based on various meteorological data such as longitudinal observations, yellow dust, ultraviolet radiation from 2018 to 2022 for each region in Korea. Here, the meteorological data had an imbalance problem, so the imbalance problem was solved by oversampling. As a result, we found that the variables affecting abnormal temperature are different in different regions. In particular, the central and southern regions are influenced by high pressure (Mainland China, Siberian high pressure, and North Pacific high pressure) due to their regional characteristics, so pressure-related variables had a significant impact on the classification of abnormal temperature. This suggests that a regional approach can be taken to predict abnormal temperatures from the surrounding meteorological environment. In addition, in the event of an abnormal temperature, it seems that it is possible to take preventive measures in advance according to regional characteristics.

Effect of Direct Solar Radiation with Sloped Topography in a Mesoscale Meteorological Model (중규모 기상모형에서 지표면 경사를 고려한 직달 복사량의 효과)

  • Shin, Sun-Hee;Lee, Young-Sun;Ha, Kyung-Ja
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.4
    • /
    • pp.45-59
    • /
    • 2006
  • In this study, the effects of the surface topographical characteristics on the meteorological fields are examined in a mesoscale meteorlolgical model. We calculated the direct solar radiation using the illumination angle considering the inclination of topography and tried to find out its effect on meteorological fields. In above experiments, we selected two cases for the clear day and the cloudy day to show the effect of weather and represented the results for two cases. In the correction of the direct solar radiation, the results of two cases indicate that there are obvious differences on the steep Taeback and Soback mountains. And on the time-series analysis the east-facing slope of these mountains receives the more direct solar radiation about $10-60W/m^2$ in the morning hours but lesser in the afternoon hours than the horizontal surface while it is opposite on the west-facing slope. And the results mentioned above are more obvious at clear day. With the same analysis method, at clear day, the surface skin temperature is higher at all hours than that on horizontal surface on the both of slope. At cloudy and rainy day, the surface skin temperature on the east-facing slope is higher in the morning hours but lower in the afternoon hours than that on horizontal surface. But on the west-facing slope, it is higher at all hours than that on horizontal surface. In the two cases, the temperature considering the slope of surface is almost higher than that on the horizontal surface. The wind is stronger than that on the horizontal surface with increasing pressure gradient force according as increasing temperature gradient around the Taeback and the Soback mountains.

  • PDF

A Study on Compression Paddle Materials to Reduce Radiation Exposure Dose During Mammography; PC and PMMA and Carbon (유방촬영 시 피폭선량을 줄이기 위한 압박대 재질의 PC, PMMA, Carbon에 대한 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.81-87
    • /
    • 2015
  • This study was designed the band material in order to reduce the exposure pressure of the breast and the material was measured of Radiolucent and radiation properties with a radiation materials of PC, PMMA, Carbon. Also the image quality by image analysis to obtain the following results are below: Unfors Xi dosimetry using radiation transmittance when the results of 8.353mGy is measured after removal of the cuff, the PC 6.308mGy, PMMA 6.223mGy, Carbon 7.218mGy were measured respectively. Semi-layer PC 0.375mmAl, PMMA 0.370mmAl, with Carbon 0.360mmAl Carbon, PC, PMMA was higher radiation properties and transparency in order. InLight / OSL NanoDotTM dosimeter was used in the cuff and then removed by placing the dosimeter measured results center on 1.143mGy, at the edge 12.56mGy, on the central PC 8.990mGy, at the edge 10.291mGy, PMMA center on 8.391mGy, the edge 9.654mGy, on Carbon center 9.581mGy, 11.313 mGy were measured at the edge of Carbon, PC, PMMA showed a high permeability in order. Image Pixel average J is then removed from the cuff 976.655, PC 831.032, PMMA 819.069, Carbon 897.118 Carbon, PC, PMMA was measured by high order.

Prediction of the Acoustic Performance of a Music Hall Considering the Radiation Characteristics of Korean Traditional Musical Sources (국악음원의 방사특성을 고려한 국악원의 음향 성능 예측)

  • 정철호;이정권;연철호;한찬훈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.146-161
    • /
    • 2004
  • There have been always some difficulties in target setting and conditioning of acoustic performances of the Korean traditional music hall due mainly to the lack of the information on the sound radiation characteristics of Korean musical sources. In this study, the radiation characteristics of four typical Korean traditional musical sources were investigated in precision and their usage was demonstrated: The selected musical sources were Gayageum (string), Daegeum (woodwind), Jango (drum), and Pansori Chang (vocal performance). Each sound source was located at the center of a semi-anechoic chamber and the directivity was determined by the measured sound pressure levels in every 10° angular position, for both vertical and horizontal directions. The directivity pattern of Gayageum varies from a uniform to a complex pattern having many side lobes with the increase of frequency. The main radiation of Daegeum is toward the upward direction. The directivity pattern of Jango is clearly a side-oriented one and the left direction intensity is sharper than its right side at low frequencies. For the Chang, the directivity pattern change from a uniform pattern to a frontally directed one as the frequency goes high. Measured directional and spectral characteristics of traditional Korean music sources were implemented into the computation of architectural acoustic measures for the Busan National Korean Traditional Music Hall which is under construction. Parameters such as RT, SPL, C80, IE, STI were calculated at two receiver positions by using a ray tracing technique. Significant differences in the acoustic measures at receiver positions were observed between the results in using the omni-directional source and the directional one. It is thought that the suggested source data and design method can be used as a basic reference in the future acoustic design of performance halls for the Korean traditional music.

Gliomatosis Cerebri : Clinical Features and Prognosis (대뇌 신경교종증 : 임상특징 및 예후에 관한 연구)

  • Jo, Dae-Chuol;Hwang, Jeong-Hyun;Sung, Joo-Kyung;Hwang, Sung-Kyu;Hamm, In-Suk;Park, Yeun-Mook;Byun, Seung-Yul;Kim, Seung-Lae
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.12
    • /
    • pp.1399-1405
    • /
    • 2001
  • Objectives : Gliomatosis cerebri is an uncommon primary brain tumor characterized by diffuse neoplastic proliferation of glial cells, with the preservation of the underlying cytoarchitecture. The aim of this study is to evaluate clinical features, outcome of surgical treatment and adjuvant therapy of gliomatosis cerebri. Methods : Between Jan. 1990 and Dec. 2000, 12 patients were diagnosed with gliomatosis cerebri based on characteristic radiological and histological findings. The patients' age ranged from 18 to 77(mean 44) years and the male to female ratio was 7 : 5. Nine patients underwent decompressive surgery and three, biopsy only. Postoperative radiation therapy was given in all cases except three. In addition to radiation therapy, four patients received chemotherapy. The mean duration of follow-up period was 18.8 months. Results : The most common presenting symptom were seizure and motor weakness. The mean duration of symptom was 5.9 months. There was 5 bilateral lesions and tumor involved corpus callosum in 5, basal ganglia-thalamus in 4, and brain stem in 2. There was no operative mortality but four patients died during the follow-up. The mean survival period for 11 patients was 20.5 months from the time of diagnosis. In univariate analysis, the lesion involving corpus callosum, basal ganglia-thalamus and brain stem correlated significantly with the short length of survival(p<0.05). Also, postoperative radiation as a adjuvant therapy prolonged the patient's survival(p<0.05). Conclusions : In the management of gliomatosis cerebri patients, early detection by MR imaging, active management of increased intracranial pressure, decompressive surgical removal and postoperative adjuvant therapy such as radiation is thought to be a good treatment modality.

  • PDF

Analysis of Key Parameters for Designing the Spent Nuclear Fuel Disposal Container in Korea (사용후핵연료 처분용기 설계를 위한 주요인자 분석)

  • Choi, Jong-Won;Cho, Dong-Keun;Choi, Hui-Ju
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.1
    • /
    • pp.37-46
    • /
    • 2006
  • For the first step to develop a reference disposal container of spent fuel to be used in a deep geological repository, this paper examined safe dimensions of the disposal container on the points of nuclear criticality and radiation safety and mechanical structural safety and provided basic information for dimensioning the container and configuration of the container components, and establishing the favorable and safe disposal conditions. When the safety factor for stress due to the external loads (hydrostatic and swelling pressure) is taken as 2.0, the safe diameter of the filler material to provide enough container strength under the assumed external loads is found to be 112cm with 13cm spacing between inner baskets in PWR container. Also the thickness of the thinner section between the fuel basket and the surface of the cast insert is determined to be 150 mm. Regarding these dimensions of the container, the PWR fuel container is sketched to accommodate 4 square assemblies or 297 CANDU fuel 297 bundles (33 circle tubes x 9 stacks). However the top and bottom parts need to be checked again through the detail radiation shielding analysis with respects to the emplacement position and handling processes of the disposal container.

Quantitative Analysis of Voice Quality after Radiation Therapy for Stage T1a Glottic Carcinoma (T1a 병기 성문암의 방사선 치료 후 음성에 관한 연구)

  • Lee Joon-Kyoo;Chung Woong-Gi
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.17-21
    • /
    • 2005
  • Purpose : To evaluate the voices of irradiated patients with early glottic carcinoma and to compare these with the voices of healthy volunteers. Materials and Methods : The voice samples (sustained vowel) of seventeen male patients who had been irradiated for T1a glottic squamous carcinoma at least 1 year prior to the study were analyzed with objective voice analyzer (acoustic voice analysis, aerodynamic test, and videostroboscopic analysis) and compared with those of a normal group of twenty age- and sex-matched volunteers. Average fundamental frequency, jitter, shimmer, and noise-to-harmonic ratio were obtained for acoustic voice analysis. Maximal phonation time, mean flow rate, intensity, subglottic pressure, glottal resistance, glottal efficiency, and glottal power were obtained for aerodynamic test. Results : The irradiated group presented higher values of shimmer in acoustic voice analysis. There was no significant difference between two groups in other parameters. Conclusion : In this study all the objective voice parameters except shimmer were no4 significantly different between the irradiated group and the control group. These results suggest that the voice quality is minimally affected by radiation therapy for 71 a glottic carcinoma.

Development and Application of Test Apparatus for Classification of Sealed Source (밀봉선원의 성능시험을 위한 장치 개발 및 적용)

  • Kim, Dong-Hak;Seo, Ki-Seog;Bang, Kyoung-Sik;Lee, Ju-Chan;Son, Kwang-Je
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.35-44
    • /
    • 2007
  • Sealed sources have to conducted the tests be done according to the classification requirements for their typical usages in accordance with the relevant domestic notice standard and ISO 2919. After each test, the source shall be examined visually for loss of integrity and pass an appropriate leakage test. Tests to class a sealed source are temperature, external pressure, impact, vibration and puncture test. The environmental test conditions for tests with class numbers are arranged in increasing order of severity. In this study, the apparatus of tests, except the vibration test, were developed and applied to three kinds of sealed source. The conditions of the tests to class a sealed source were stated and the difference between the domestic notice standard and ISO 2919 were considered. And apparatus of the tests were made. Using developed apparatus we conducted the tests for $^{192}Ir$ brachytherapy sealed source and two kinds of sealed source for industrial radiography. $^{192}Ir$ brachytherapy sealed source is classified by temperature class 5, external pressure class 3, impact class 2 and vibration and puncture class 1. Two kinds of sealed source for industrial radiography are classified by temperature class 4, external pressure class 2, impact and puncture class 5 and vibration class 1. After the tests, Liquid nitrogen bubble test and vacuum bubble test were done to evaluate the safety of the sealed sources.

A Study on the combustion characteristcs for backpressure of exhaust system in SI engine (배기(排氣)시스템의 배압(背壓)과 연소특성(燃燒特性)에 관한 연구)

  • Park, Dai-Un;Park, Kyoung-Suk;Park, Se-Jong;Son, Sung-Man
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.206-212
    • /
    • 2004
  • It is necessary to consider the stability, economic environmental-friendly problems by the development of the road, supply of the automobile, environmental problem as designing the exhaust system. To reduce the noise and the vibration of the automobile, it is needed to consider the pulsation noise, air current noise, vibration of air pipe which generate the intake and exhaust noise of the automobile. Moreover, the discharge sounds, intake sound, radiation sound, transmitted sound are occurred. To reduce this influence, the variable valve is needed and to control these factors, path transformation muffler and active type muffler are needed. While engine efficiency could be reduced with this transformationand resistance by the pressure, thermal property. In this study, how to design exhaust systems yielding higher condversion efficiency, lower backpressure and optimize the performance. this study is recommended for exhaust system and designers and engineers involved in SI engine exhaust system and it will furnish information for you to design more efficient.

  • PDF

Shock Tube and Modeling Study of Ethanol Ignition (에탄올 점화 과정에 관한 충격관 실험 및 모델 연구)

  • Shin, Kuan-Soo;Park, Ki-Soo;Gwon, Eun-Sook
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.1
    • /
    • pp.12-16
    • /
    • 2004
  • The ignition of ethanol-oxygen-argon mixture was studied in reflected shock waves over the temperature range of 1281-1625 K and the pressure range of 0.69-1.06 bar. The ignition delay time was measured by the sudden increase of pressure profile and the radiation emitted by OH radicals. The relationship between the ignition delay time and the concentrations of ethanol and oxygen was determined in the form of mass-action expressions with an Arrhenius temperature dependence. In contrast to the behavior observed in methanol, ethanol acts to inhibit rather than accelerate its own ignition. Several kinetic mechanisms proposed for ethanol oxidation at high temperatures have been tested by the computer simulation.