• Title/Summary/Keyword: Radiation noise

Search Result 765, Processing Time 0.039 seconds

The numerical analysis of heavy-weight impact noise for an apartment houses considering acoustic mode (Acoustic mode 를 고려한 공동주택 중량충격음 소음해석)

  • Mun, Dae-Ho;Hwang, Jae-Seung;Park, Hong-Gun;Hong, Geon-Ho;Im, Ju-Hyeuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.394-402
    • /
    • 2009
  • To investigate the heavy-weight impact noise of apartment houses, numerical analysis was performed. The analysis acoustic pressure consider acoustic mode by finite element method. The variables considered effecting on the acoustic pressure are the Acoustic mode, acoustic damping, and the impulse load. The heavy-weight impact noise is a changeable value in the room. Since the most part of the frequency component of heavy-weight impact noise has low frequency. The noise in low frequency is related to the vibration of structure, the reflection of acoustic wave caused by wall and the standing wave called by acoustic mode. The prediction by the numerical analysis was verified with test result of the heavy weight-impact noise at apartment houses.

  • PDF

Vibro-acoustic Analysis for Predicting the Noise of HDD (하드디스크 드라이브 소음 예측을 위한 진동 음향 연계 해석)

  • 이상희;고상철;김준태;강성우;한윤식;황태연
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.103-108
    • /
    • 2001
  • The structure of hard disk drive(HDD) is excited by dynamic motion of a disk-spindle motor, and it makes sound noise. Therefore, the cover and the base of HDD should be designed to reduce noise and vibration induced by spindle motor. The prediction technique of sound pressure level(SPL) of a given structural shape enables us to design a cover and a base with much less vibration and noise. In this paper, we measured the force of disk-spindle motor and predicted SPL from HDD by computational simulation. To get a SPL of HDD by computational simulation, modal analysis and forced vibration analysis were performed with ANSYS, and sound radiation was computed using SYSNOISE. The calculated results were compared with experimental results and a good agreement was obtained. With this computer simulation procedure and design of experiment(DOE), optimal thickness of noise barrier and damper was calculated.

  • PDF

Transfer Function of Structure-borne Noise to Underwater Radiated Noise (고체음의 수중방사소음 전달함수)

  • 김재승;김현실;김상렬
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.138-142
    • /
    • 2001
  • A comparison between theoretical and measured transfer function, which relates structure-borne noise source level to underwater radiated noise, of a naval ship is presented in this study. Transfer functions are obtained by dividing far field underwater noise by the value of structure borne noise source levels below machinery mounts. In prediction, statistical energy analysis of the whole ship structure is used to get vibration levels of wetted hull plates below water line. Then, far field radiated noise is calculated by summing up contributions from each plates using vibration levels and radiation efficiencies. And 1/3-octave band underwater sound pressure at the distance of 1 m away from the hull were measured to get experimental transfer functions. The two transfer functions are compared to show resonable agreements in spite of the subtle physical differences between each other.

  • PDF

Comparison of track vibration characteristics for domestic railway tracks in the aspect of rolling noise (철도 전동 소음의 관점에서 해석한 국내 철도의 진동 특성 비교)

  • Ryue, Jungsoo;Jang, Seungho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.644-647
    • /
    • 2013
  • The important source of noise from railways is rolling noise caused by wheel and rail vibrations induced by acoustic roughness at the wheel-rail contact. The main contributors for rolling noise are the sleepers, rail and wheels. In order to analyze and predict rolling noise, it is necessary to understand the vibrating behaviors of railway tracks, as well as the wheels. In the present paper, theoretical modelings of the railway track are reviewed in terms of the rolling noise, and they are applied for the three representative types of domestic railway tracks operated: the conventional ballasted track, KTX ballasted track and KTX concrete track. The characteristics of waves propagating along rails were investigated and compared between the tracks. The tracks were modeled as discretely supported Timoshenko beams and compared in terms of the averaged squared amplitude of velocity which is directly related to the sound radiation from the rails.

  • PDF

An Experimental Study to Evaluate Noise Characteristic of an Electric Power Driven Hammer (전동식 해머의 소음 특성 파악을 위한 흡차음 실험 연구)

  • Lee, Kwang-Gil;Choi, Seung-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.23-26
    • /
    • 2011
  • The aim of this paper is to evaluate noise characteristics of an electric power driven hammer. These investigation and analysis were made according to the ISO 1680/1 and MIL-STD 7410-1 and lead-wrapping experiment method that was used to identify the principal noise sources and analyze its noise. Hammer generates loud noise and it irritates and affects many people. Repeated exposures to loud noise can lead people to permanent hearing loss. Based on the contribution analysis, we confirm that the striker part is a major noise source and it has directional noise radiation pattern, which is left and right.

Study on Pressure Pulsation and Cavity Resonance in Discharge Plenum of Hermetic Compressor (공조용 밀폐형 압축기의 토출부 압력맥동 및 케비티 공명에 대한 연구)

  • 이진갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.302-308
    • /
    • 2000
  • The major source of noise in air-conditioner is a compressor. Therefore, noise reduction in a compressor is quite significant as an element technology in air-conditioner field. Recently, a scroll compressor is widely used, because a scroll compressor features lower noise, due to less pulsation of gas pressure, than that of the rotary compressor. During a past noise reduction effort on a scroll compressor, noise radiation from the discharge portion of the hermetic shell was identified as the major contributor to overall noise. For a reduction of noise, the source of noise at the discharge portion must be identified. This paper presents detailed analyzes for the discharge pressure pulsation and cavity resonance at discharge space, which will make possible a low noise design of a scroll compressor.

  • PDF

A Study on Radiation Hardening of a Infrared Detector (적외선 탐지소자의 내방사선화 연구)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.490-492
    • /
    • 2005
  • A study on radiation hardening of infrared(IR) detector, the chief component of IR camera was performed. The radiation test on IR sensor passivated with the ZnS by Co$^{60}$ gamma-ray over 1 Mrads showed the reduction in Ro by 1/100 which was related to the noise level. This effect that was caused by carrier trapping in the ZnS passivation layer increased the leakage current and resulted in degradation in the device performance. For the radiation hardening of IR devices we suggested the ones with CdTe passivation layer which had a tendency to reluctant to carrier trapping in its layer and developed test patterns. Radiation test to the patterns showed that the our CdTe passivated device could survived over 1 Mrad gamma-ray dose.

Analysis of Acoustic Radiation Efficiency and Underwater Radiated Noise of Double Bottom-shaped Structure (이중저 형상 구조물의 음향방사효율과 수중방사소음 해석)

  • Choi, Sung-Won;Kim, Kook-Hyun;Cho, Dae-Seung;Suh, Kyu-Youl
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.2
    • /
    • pp.158-163
    • /
    • 2012
  • Recently, reducing underwater radiated noise (URN) of ships has become an environmental issue to protect marine wildlife. URN of ships can be predicted by various methods considering its generating mechanism and frequency ranges. For URN prediction due to ship structural vibration in low frequency range, the fluid-structure interaction analysis technique based on finite element and boundary element methods (FE/BEM) is regarded as an useful technique. In this paper, URN due to a double bottom-shaped structure vibration has been numerically investigated based on a coupled method of FE/BEM to enhance the prediction accuracy of URN due to the vibration of real ship engine room structure. Acoustic radiation efficiency and URN transfer function in case of vertical harmonic excitation on the top plate of double bottom structure have been evaluated. Using the results, the validity of an existing empirical formula for acoustic radiation efficiency estimation and a simple URN transfer function, which are usually adopted for URN assessment in initial design stage, is discussed.

An Analysis of the Sound Propagation between Rooms with Different Mediums (서로 다른 매질을 갖는 격실사이의 음파전달해석)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Lee, Seong-Hyun;Seo, Yun-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.402-407
    • /
    • 2013
  • In this paper, an analysis of sound propagation between two rooms with different mediums is discussed. Statistical energy analysis (SEA) is used to consider energy equilibrium among subsystems associated with the sound pressure levels in two rooms and the vibration level of the wall between rooms. Effect of the sound radiation from the structure-borne noise of the wall on sound pressure level of the receiving room is investigated. For a numerical example, sound propagation between engine room and water tank joined by a steel plate whose size is $8.4{\times}4$ m, is considered. It is found that when the critical frequency of the plate is above the frequency range of interest, the sound pressure level in the water tank is dominated by sound transmission through the plate, while sound radiation from the structure-borne noise of the plate is negligible except low frequency range below 63 Hz.

Image Quality and Radiation Dose of High-Pitch Dual-Source Spiral Cardiothoracic Computed Tomography in Young Children with Congenital Heart Disease: Comparison of Non-Electrocardiography Synchronization and Prospective Electrocardiography Triggering

  • Goo, Hyun Woo
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1031-1041
    • /
    • 2018
  • Objective: To compare image quality and radiation dose of high-pitch dual-source spiral cardiothoracic computed tomography (CT) between non-electrocardiography (ECG)-synchronized and prospectively ECG-triggered data acquisitions in young children with congenital heart disease. Materials and Methods: Eighty-six children (${\leq}3$ years) with congenital heart disease who underwent high-pitch dual-source spiral cardiothoracic CT were included in this retrospective study. They were divided into two groups (n = 43 for each; group 1 with non-ECG-synchronization and group 2 with prospective ECG triggering). Patient-related parameters, radiation dose, and image quality were compared between the two groups. Results: There were no significant differences in patient-related parameters including age, cross-sectional area, body density, and water-equivalent area between the two groups (p > 0.05). Regarding radiation dose parameters, only volume CT dose index values were significantly different between group 1 ($1.13{\pm}0.09mGy$) and group 2 ($1.07{\pm}0.12mGy$, p < 0.02). Among image quality parameters, significantly higher image noise ($3.8{\pm}0.7$ Hounsfield units [HU] vs. $3.3{\pm}0.6HU$, p < 0.001), significantly lower signal-to-noise ratio ($105.0{\pm}28.9$ vs. $134.1{\pm}44.4$, p = 0.001) and contrast-to-noise ratio ($84.5{\pm}27.2$ vs. $110.1{\pm}43.2$, p = 0.002), and significantly less diaphragm motion artifacts ($3.8{\pm}0.5$ vs. $3.7{\pm}0.4$, p < 0.04) were found in group 1 compared with group 2. Image quality grades of cardiac structures, coronary arteries, ascending aorta, pulmonary trunk, lung markings, and chest wall showed no significant difference between groups (p > 0.05). Conclusion: In high-pitch dual-source spiral pediatric cardiothoracic CT, additional ECG triggering does not substantially reduce motion artifacts in young children with congenital heart disease.