• Title/Summary/Keyword: Radiation industry

검색결과 625건 처리시간 0.019초

방사선카운슬러 자격제도의 필요성과 발전방안 (The Necessity and Development of Radiation Counsellor Qualifications System)

  • 권대철;최지원
    • 방사선산업학회지
    • /
    • 제12권4호
    • /
    • pp.373-377
    • /
    • 2018
  • The purpose of this study is to suggest a necessity and development of radiation counsellor qualifications system for the public to solve the anxiety and the curiosity about radiation exposure. We analyzed the definition and role of radiation counsellor and define radiation counsellor qualifications system. Qualification is given to those who have completed the professional training course organized by Korea Energy Information Culture Agency (KEIA). Since 2014, KEIA has been conducting radiation counsellor training, Examination and certification. This system continues to promote efforts to disseminate and develop the right knowledge about radiation risk and information of radiation risk to the public. Also, it is thought that radiation counsellors could be able to fulfill the roles needed in society through legislation for the mandatory placement of radiation counsellors.

감마선 조사를 이용하여 Poly(ethylene glycol) Mathacrylate가 그래프팅된 케냐프 섬유를 포함하는 시멘트 복합재료의 제조 (Preparation of Cement Composites Containing Kenaf Fiber Has Been Gamma-ray Grafted with Poly(ethylene glycol) Methacrylate)

  • 이병민;강필현;전준표
    • 방사선산업학회지
    • /
    • 제8권1호
    • /
    • pp.49-52
    • /
    • 2014
  • Kenaf fibers have excellent properties and possess the potential to be outstanding reinforcing fillers in cement. The grafting of poly(ethylene glycol) methacrylate (PEGMA) to the kenaf fibers is important in improving the compatibility between the fibers and the cement. PEGMA was grafted onto kenaf fibers using gamma-ray radiation. The radiation dose ranged from 20 to 60 kGy, and the dose rate was $10kGy\;h^{-1}$. The degree of grafting increased with increased radiation doses. FT-IR analysis revealed an increase in PEGMA content after gamma-ray radiation induced grafting, further evincing the attachment of PEGMA to the kenaf fibers. The mechanical properties of the gamma-ray grafted kenaf fiber/cement composites were superior to those of the ungrafted kenaf fiber/cement specimens.

Research Infrastructure Foundation for Core-technology Incubation of Radiation Detection System

  • Kim, Han Soo;Ha, Jang Ho;Kim, Young Soo;Cha, Hyung Ki
    • 방사선산업학회지
    • /
    • 제6권1호
    • /
    • pp.67-73
    • /
    • 2012
  • The development of radiation detection systems mainly consist of two parts-radiation detector fabrication including material development, and its appropriate electronics development. For the core-technology incubation of a radiation detection system, radiation fabrication and an evaluation facility are scheduled to be founded at the RFT (Radiation Fusion Technology) Center at KAERI (Korea Atomic Energy Research Institute) by 2015. This facility is utilized for the development and incubation of bottleneck-technologies to accelerate the industrialization of a radiation detection system in the industrial, medical, and radiation security fields. This facility is also utilized for researchers to develop next-generation radiation detection instruments. In this paper, the establishment of core-technology development is introduced and its technological mission is addressed.

감마선 조사에 의하여 가교된 폴리에틸렌 발포 시트의 제조 (Preparation of Polyethylene Foam Sheets Crosslinked by Gamma-ray Irradiation)

  • 이동훈;최준호;심기형;정찬희;황인태;최재학
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.211-215
    • /
    • 2012
  • In this study, crosslinked polyethylene (PE) foam sheets were prepared through gamma-ray irradiation. PE foam sheets were prepared through a foaming process using sodium bicarbonate as a blowing and foaming agent. The prepared PE foam sheets were then crosslinked through gamma-ray irradiation. The crosslinking degree was increased to 86.0% with an increase in the absorption dose. The tensile strength of the crosslinked PE foam sheets was increased with an increase in the absorption dose. However, the elongation-at-break of the crosslinked PE foam sheets was decreased. The thermal decomposition temperature of the crosslinked PE foam sheets was increased to $421.2^{\circ}C$ with an increase in the absorption dose. The SEM analysis revealed that the morphology was not changed significantly after the crosslinking through gamma-ray irradiation.

Gene Expression Profiles Following High-Dose Exposure to Gamma Radiation in Salmonella enterica serovar Typhimurium

  • Lim, Sangyong;Jung, Sunwook;Joe, Minho;Kim, Dongho
    • 방사선산업학회지
    • /
    • 제2권3호
    • /
    • pp.111-119
    • /
    • 2008
  • Microarrays can measure the expression of thousands of genes to identify the changes in expression between different biological states. To survey the change of whole Salmonella genes after a relatively high dose of gamma radiation (1 kGy), transcriptome dynamics were examined in the cells by using DNA microarrays. At least 75 genes were induced and 89 genes were reduced two-fold or more after irradiation. Several genes located in pSLT plasmid, cyo operon, and Gifsy prophage were induced along with many genes encoding uncharacterized proteins.While, the expression of genes involved in the virulence of Salmonella as well as metabolic functions were decreased. Although the radiation response as a whole could not be illustrated by using DNA microarrays, the data suggest that the response to high dose of irradiation might be more complex than the SOS response.

방사선 가교 기술을 이용한 유효성분 방출력이 우수한 하이드로겔 제조 및 특성 분석 (Characterization and Preparation of the Hydrogel has Excellent Release Effect of the Active Ingredients Using a Radiation Cross-linking Technology)

  • 황승현;안성준;박종석;정성린;권희정;이동윤;임윤묵
    • 방사선산업학회지
    • /
    • 제9권4호
    • /
    • pp.199-207
    • /
    • 2015
  • Typical radiation cross-linked hydrogels has the characteristic that high water content, but low emission efficiency of active ingredients. Therefore, the hydrogel was prepared by the addition to collagen, which is closely related to the formation of skin wrinkles in biocompatibility and highly water-soluble carboxymethyl cellulose sodium salt (CMC) in order to preparation of hydrogels has excellent emission efficiency of active ingredients. Hydrogels were prepared by dissolving CMC and collagen each of 0.5%, 10% concentration in deionized water. Then, prepared hydrogels are performed by gamma-radiation at 1, 3, 5 kGy irradiation dose. The results showed that the gel fraction of after irradiated 3 kGy hydrogel was higher than before irradiated gelation as long as the 55.3%. The swelling rate of irradiated 3 kGy hydrogel was lower than the non-irradiated sample. The compressive strength of 3 kGy irradiated hydrogel was the highest. The visco-elastic did not show any significant differences, even after irradiation. The CMC hydrogel in this study suggested a potential use as a material for the mask pack for improved emission efficiency of the active ingredient and anti-wrinkles.

방사선 기술정보 분석을 통한 정보표준분류체계(안) 마련 및 시스템 적용요건 도출 (Provision of a Draft Version for Standard Classification Structure for Information of Radiation Technologies through Analyzing Their Information and Derivation of Its Applicable Requirements to the Information System)

  • 장솔아;김주연;유지엽;신우호;박태진;송명재
    • 방사선산업학회지
    • /
    • 제9권1호
    • /
    • pp.29-35
    • /
    • 2015
  • Radiation technology is the one for developing new products or processes by applying radiation or for creating new functions in industry, research and medical fields, and its application is increasing consistently. For securing an advanced technology competitiveness, it is required to create a new added value by information consumer through providing an efficient system for supporting information, which is the infrastructure for research and development, contributed to its collection, analysis and use with a rapidity and structure in addition to some direct research and development. Provision of the management structure for information resources is especially crucial for efficient operating the system for supporting information in radiation technology, and then a standard classification structure of information must be first developed as the system for supporting information will be constructed. The standard classification structure has been analyzed by reviewing the definition of information resources in radiation technology, and those classification structures in similar systems operated by institute in radiation and other scientific fields. And, a draft version of the standard classification structure has been then provided as 7 large, 25 medium and 71 small classifications, respectively. The standard classification structure in radiation technology will be developed in 2015 through reviewing this draft version and experts' opinion. Finally, developed classification structure will be applied to the system for supporting information by considering the plan for constructing this system and database, and requirements for designing the system. Furthermore, this structure will be designed in the system for searching information by working to the individual need of information consumers.

제니스틴에 의한 방사선유발 세포사멸 민감도증가 (Sensitization of Radiation-Induced Cell Death by Genistein)

  • 김태림;김인규
    • 방사선산업학회지
    • /
    • 제4권1호
    • /
    • pp.91-94
    • /
    • 2010
  • A number of epidemiological studies as well as biological experiments, showed that genistein, one of the isoflavone, prevents prostate cancer occurrence. In this study, we showed that genistein inhibited the cell proliferation of human promyeoltic leukemia HL-60 cells and induced G2/M phase arrest. In addition, combination of genistein treatment and ${\gamma}$-irradiation displayed synergistic effect in apoptotic cell death of HL-60 cells. This means that the repair of genistein-induced DNA damage was hindered by ${\gamma}$-radiation and thus cell death was increased. In conclusion, genistein is one of the important chemicals that sensitize radiation-induced cell death.

방사선 그래프트를 순차적으로 진행하여 제조된 실란 가교구조의 수소이온교환막 (Silane-crosslinked Proton Exchange Membranes Prepared by a Stepwise Radiation Grafting)

  • 이지홍;최홍석;송주명;손준용;신준화
    • 폴리머
    • /
    • 제36권6호
    • /
    • pp.816-821
    • /
    • 2012
  • 본 연구에서는 스티렌(styrene)과 TMSPM(3-(trimethoxysilyl)propyl methacrylate) 단량체를 방사선을 이용하여 ETFE(poly(ethylene-co-tetrafluoroethylene)) 필름에 순차적으로 그래프트시킨 후 졸-젤 반응 및 설폰화 반응을 진행하여 실란 가교구조의 수소이온교환막을 제조하였다. 그래프트시 수소이온 전도성을 부여하게 될 스티렌과 가교구조를 형성시킬 TMSPM의 그래프트 순서가 다른 두 종류의 필름을 제조하여 FTIR을 통하여 구조 변화를 비교하였으며, TGA를 이용하여 열적 특성 변화를 관찰하였다. 두 종류의 필름에 설폰산 작용기를 도입한 후 SEM-EDX 기기를 이용하여 막 내부 설폰산 및 실리콘의 분포를 확인하였다.

방사선을 이용한 바나듐 레독스 흐름전지용 이온 투과선택성 분리막의 제조 및 특성 평가 (Preparation and Characterization of Ionic Permselective Membrane by Radiation Grafting for Vanadium Redox Flow Battery)

  • 손준용;송주명;신준화
    • 방사선산업학회지
    • /
    • 제7권1호
    • /
    • pp.61-67
    • /
    • 2013
  • In this study, we developed ionic permselective membrane as a core material of redox flow battery using radiation grafting method. Two ionic permselective membranes, ETFE-g-PSSA and ETFE-g-PVBSA were prepared by radiation grafting with styrene and VBC followed by sulfonation, respectively. We confirmed that the prepared membranes were successfully prepared via FT-IR. The prepared ionic permselcetive membranes were characterized and the performance of the membranes were evaluated as ionic permselective membranes for vanadium redox flow battery.