• Title/Summary/Keyword: Radiation flux

Search Result 560, Processing Time 0.031 seconds

Observational Study on the Local Wind of the Dalbi-Valley Located at Ap-Mountain in Daegu (대구 앞산 달비골의 국지풍 특성에 관한 관측적 연구)

  • Koo, Hyun-Suk;Kwon, Byung-Hyuk;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.73-79
    • /
    • 2007
  • The purpose of this study is to clarify the effect of mountain-valley wind on heat island formed in urban area which is located around valley mouth. The meteorological observations were carried out over the Dalbi-valley under a clear summer pressure patterns, and some consideration were tried from the results. In order to make clear the climatological characteristics and air-mass modification process of the mountain-valley wind over the valley, the meteorological observations were done simultaneously at two points. The observational points were located at the breast and valley mouth parts, respectively. The results were as follows: First, it was found that the valley wind was observed through the daytime, and it was replaced by a mountain wind after sunset. Second, the heat budget is also investigated with observation data. The sensible heat flux over the breast of Dalbi-valley reached to about $200 W/m^2$ during daytime, which is a little more than one third of net radiation. On the other hand, the sensible heat flux represented negative values during nighttime. But the sensible heat flux over the valley mouth covered by asphalt showed plus value(about $20{\sim}30 W/m^2$) during the nighttime.

Flux of Carbon Dioxide and Deposition Velocity of Ozone over Glycine max Canopy (대두 개체군에 있어서 $CO_2$$O_3$ 플럭스)

  • 김원식;이호준
    • The Korean Journal of Ecology
    • /
    • v.23 no.1
    • /
    • pp.39-43
    • /
    • 2000
  • Carbon dioxide (CO₂) and ozone (O₃) fluxes were measured over Glycine max canopy using the bowen ratio energy balance method at Fuchu - 20 km west of Tokyo, in late July and late September 1996. The CO₂, and O₃, fluxes were influenced by variation in leaf area index (LAI) during the measuring period. When LAI was more than 3.0, the CO₂ flux was found to be positively correlated with photosynthetically active radiation (PAR). The O₃, flux was always positive with an average deposition velocity for this case of about 0.5 mol m/sup -2/s/sup -1/. A positive correlation existed between the deposition velocity of O₃ and CO₂ during the period of LAI>2.0.

  • PDF

Neutron activation analysis: Modelling studies to improve the neutron flux of Americium-Beryllium source

  • Didi, Abdessamad;Dadouch, Ahmed;Jai, Otman;Tajmouati, Jaouad;Bekkouri, Hassane El
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.787-791
    • /
    • 2017
  • Americium-beryllium (Am-Be; n, ${\gamma}$) is a neutron emitting source used in various research fields such as chemistry, physics, geology, archaeology, medicine, and environmental monitoring, as well as in the forensic sciences. It is a mobile source of neutron activity (20 Ci), yielding a small thermal neutron flux that is water moderated. The aim of this study is to develop a model to increase the neutron thermal flux of a source such as Am-Be. This study achieved multiple advantageous results: primarily, it will help us perform neutron activation analysis. Next, it will give us the opportunity to produce radio-elements with short half-lives. Am-Be single and multisource (5 sources) experiments were performed within an irradiation facility with a paraffin moderator. The resulting models mainly increase the thermal neutron flux compared to the traditional method with water moderator.

Fabrication of a superheated emulsion based on Freon-12 and LiCl suitable for thermal neutrons detection

  • Sara Sadat Madani Kouchak;Dariush Rezaei Ochbelagh;Peiman Rezaeian;Majid Abdouss
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1425-1430
    • /
    • 2024
  • This study develops superheated emulsion detectors that are both sensitive to fast neutrons, and thermal neutrons owing to the exergonic 63Li(n, α)31H capture reaction caused by the 6Li-containing compound dispersed throughout the gel-like medium. The experimental research was conducted on two SEDs. One detector was an ordinary Freon-12 detector and the other was a Freon-12 detector containing 3.4 % (by weight) LiCl. In order to investigate the sensitivity of lithium-containing SEDs to thermal neutrons, two types of SEDs were simultaneously exposed to various flux levels of thermal neutrons from 241Am-Be neutron source inside a cylindrical tank filled with water. A Boron-lined proportional counter was used to estimate the thermal neutron flux and the relevant MCNP code was developed for flux and dose calculations in the prepared set-up around 241Am-Be source. The results demonstrate that there is a proportional relationship between the variations of SED response and the change in thermal neutron flux and dose. Also, the sensitivity of SED was estimated.

Neutron Flux Evaluation on the Reactor Pressure Vessel by Using Neural Network (인공신경 회로망을 이용한 압력용기 중성자 조사취화 평가)

  • Yoo, Choon-Sung;Park, Jong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.168-177
    • /
    • 2007
  • A neural network model to evaluate the neutron exposure on the reactor pressure vessel inner diameter was developed. By using the three dimensional synthesis method described in Regulatory Guide 1.190, a simple linear equation to calculate the neutron spectrum on the reactor pressure vessel was constructed. This model can be used in a quick estimation of fast neutron flux which is the most important parameter in the assessment of embrittlement of reactor pressure vessel. This model also used in the selection of an optimum core loading pattern without the neutron transport calculation. The maximum relative error of this model was less than 3.4% compared to the transport calculation for the calculations from cycle 1 to cycle 23 of Kori unit 1.

Direct Observation of Radiative Flux in the Southern Yellow Sea

  • Lu, Lian-Gang;Yu, Fei;Diao, Xinyuan;Guo, Jingsong;Wang, Huiwu;Wei, Chuanjie
    • Ocean Science Journal
    • /
    • v.43 no.2
    • /
    • pp.115-126
    • /
    • 2008
  • Direct measurements of four radiative components at air-sea boundary layer were conducted in the southern Yellow Sea during three cruises (seasons) in 2007. Simultaneous observations of meteorological (cloud cover, air temperature and humidity) and oceanographic (sea surface temperature) parameters were carried out. Observational results of radiative fluxes and meteorological and oceanographic parameters are presented. Mean diurnal cycles of four radiative components, net radiation, and sea surface albedo are calculated to achieve averages in different seasons. Net radiative fluxes in three seasons (winter, spring, autumn) are 8, 146, $60\;W/m^2$, respectively. Comparisons between the observed radiative fluxes and those estimated with formulas are taken.

Calculation of Neutron Energy Distribution from the Components of Proton Therapy Accelerator Using MCNPX (MCNPX를 이용한 양성자 치료기의 구성품에서 발생하는 중성자 에너지 분포계산)

  • Bae, Sang-Il;Shin, Sang-Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.917-924
    • /
    • 2019
  • The passive scattering system nozzle of the proton therapy accelerator was simulated to evaluate the neutrons generated by each component in each nozzle by energy. The Monte Carlo N-Particle code was used to implement spread out Bragg peak with proton energy 220 MeV, reach 20 cm, and 6 cm length used in the treatment environment. Among the proton accelerator components, neutrons were the highest in scatterers, and the neutron flux decreased as it moved away from the central flux of the proton. This study can be used as a basic data for the evaluation of the radiation necessary for the maintenance and dismantling of proton accelerators.

Conductive-Radiative Heat Transfer in an Infinite Square Duct with Dielectric Directional Property Wall (부도체 방향복사면이 있는 무한 정사각관의 전도-복사열전달)

  • Byun, Ki-Hong;Im, Moon-Hyuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.5
    • /
    • pp.543-552
    • /
    • 2003
  • The effects of a directionally emitting and reflecting dielectric surface on the wall heat flux and medium temperature distribution are studied. The system is an infinite square duct enclosing an absorbing and emitting medium. The emissivity and reflectivity of opaque and gray wall vary with direction. Combined effect of conductive and radiative heat transfer is analyzed using finite difference and the direct discrete-ordinates method. The parameters under study are conduction to radiation parameter, optical depth, refractive index ratio. The results with directional and diffuse properties deviate each other when the conduction to radiation parameter is less than around 0.01. The wall heat flux differs fur optical thickness less than around 0.1. However, the medium temperature profiles differ for optical thickness greater than around 1. Deviations from diffuse property calculations are larger for hot wall with directional property than cold wall with directional property. As n increases from 1.5, the trend changes are observed fur refractive index ratio about n=6.10

[ $Bi_2Sr_2CaCu_2O{8+\delta}$ ] Intrinsic Josephson Junctions in a Parallel Magnetic Field

  • Lee, J.H.;Chong, Yon-Uk;Lee, Su-Youn;Khim, Z.G.
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.110-114
    • /
    • 2000
  • We have investigated the Josephson vortex dynamics in $Bi_2Sr_2CaCu_2O{8+\delta}$ intrinsic Josephson junctions subjected to a magnetic field parallel to $CuO_2$ planes. We investigated mesas with $40\times40{\mu}m^2$ in size and containing 6 and 20. intrinsic junctions. The zero field I-V characteristics exhibited a typical hysteretic, multi-branched nature of the intrinsic Josephson effect. At high magnetic fields (H>1.5 T), I-V characteristics showed flux flow steps. The Swihart velocity obtained from this observation was about $4.2\times10^5$ m/s, which was the lowest mode electromagnetic wave velocity of N coupled stack. The experimental I-V curves fitted well into the simple model of Cherenkov radiation including Ohmic and non-linear dissipation terms. This suggests that the dissipation mechanism of Josephson vortex be due to both Cherenkov radiation and quasiparticle tunneling current.

  • PDF

Spatial Variability of Soil Heat Fluxes in a Conifer Forest (침엽수림에서 토양열 플럭스의 공간 변화)

  • Yun-Ho Park;Byong-Lyol Lee;Kyung-Sook Cho
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.81-86
    • /
    • 2003
  • The spatial variability of soil heat fluxes in a conifer forest was investigated by meteorological measurement. The maximum daily averages of R $s_{dn}$ and Rn were about 260 W $m^{-2}$ and 180 W $m^{-2}$ . The daily average of G was typically 10% of net radiation during mid-July to mid-August. The measured soil heat flux of $G_{6}$ was suitable to calculate G within 2% error during the study period. A time delay in the maximum nux at a depth of 0.1 m by heat storage was observed. About 10 to 15 W $m^{-2}$ of error can occur, if it is neglected.