• 제목/요약/키워드: Radiation detectors

검색결과 295건 처리시간 0.028초

이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발 (Development of Measurement System for Industrial Transportable Gamma Ray CT)

  • 김종범;정성희;문진호
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

The Low-Radiation Dosimetry Application of "tris" Lyoluminescence using Electron Paramagnetic Resonance at Low Temperature

  • Son, Phil-Kook;Choi, Suk-Won;Kim, Sung-Soo;Gwag, Jin-Seog
    • Journal of Magnetics
    • /
    • 제17권3호
    • /
    • pp.172-175
    • /
    • 2012
  • We present a method for detecting very weak radiation by analyzing the inner structure of irradiated tris (lyoluminescence) materials using electron paramagnetic resonance (EPR) at low temperature. Organic materials have been looked into for use in emergency dosimetry of inhabitants around radiation accidents. However, this technology has never been applied to imperceptible radiation doses (< 0.5 Gy) because there is no proper method for detecting the change of inner structure of the subject bombed by very weak radiation at room temperature. Our results show that tris materials can be applied as a radiation detectors of very small radiation doses below 0.05 Gray, if EPR is used at low temperature (130 K ${\leq}$ T ${\leq}$ 270 K). The EPR signal intensity from the irradiated-tris sample had barely faded at all after 1 year.

GM Tube 및 NaI(TI) 검출기를 사용한 Wide-Range 방사선 측정 시스템의 설계 (Design of Wide-Range radiation measurement system using GM Tube and NaI(TI) Detector)

  • 라승탁;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.146-149
    • /
    • 2017
  • 본 논문에서는 GM Tube 및 NaI(TI) 검출기를 사용한 Wide-Range 방사선 측정 시스템을 제안한다. 제안하는 시스템은 NaI(Tl) 검출기 및 GM Tube의 검출기 신호를 제어, 계수할 수 있게 최적화한 하나의 소형 모듈로 설계한 다. 방사선량은 2개의 검출기를 연동하여 Wide-range인 0.1uSv/h~10mSv/h 구간에서 측정되고, 측정구간이 중복되는 지점인 10uSv/h~100uSv/h에서는 2개의 검출기가 동시에 동작한다. 방사선량은 중첩된 방사선 측정 가능 구간에 대해 적정한 구간에서 해당 검출기 기능의 On/Off를 제어하는 Wide-Range 방사선 측정 알고리즘을 이용하여 선택 적용하였다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과, 각 구간별로 측정 불확도가 ${\pm}7.5%$로 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.

Calculation of Detector Positions for a Source Localizing Radiation Portal Monitor System Using a Modified Iterative Genetic Algorithm

  • Jeon, Byoungil;Kim, Jongyul;Lim, Kiseo;Choi, Younghyun;Moon, Myungkook
    • Journal of Radiation Protection and Research
    • /
    • 제42권4호
    • /
    • pp.212-221
    • /
    • 2017
  • Background: This study aims to calculate detector positions as a design of a radioactive source localizing radiation portal monitor (RPM) system using an improved genetic algorithm. Materials and Methods: To calculate of detector positions for a source localizing RPM system optimization problem is defined. To solve the problem, a modified iterative genetic algorithm (MIGA) is developed. In general, a genetic algorithm (GA) finds a globally optimal solution with a high probability, but it is not perfect at all times. To increase the probability to find globally optimal solution rather, a MIGA is designed by supplementing the iteration, competition, and verification with GA. For an optimization problem that is defined to find detector positions that maximizes differences of detector signals, a localization method is derived by modifying the inverse radiation transport model, and realistic parameter information is suggested. Results and Discussion: To compare the MIGA and GA, both algorithms are implemented in a MATLAB environment. The performance of the GA and MIGA and that of the procedures supplemented in the MIGA are analyzed by computer simulations. The results show that the iteration, competition, and verification procedures help to search for globally optimal solutions. Further, the MIGA is more robust against falling into local minima and finds a more reliably optimal result than the GA. Conclusion: The positions of the detectors on an RPM for radioactive source localization are optimized using the MIGA. To increase the contrast of the measurements from each detector, a relationship between the source and the detectors is derived by modifying the inverse transport model. Realistic parameters are utilized for accurate simulations. Furthermore, the MIGA is developed to achieve a reliable solution. By utilizing results of this study, an RPM for radioactive source localization has been designed and will be fabricated soon.

방사선 분포 모니터링 시스템 (Radiation level distribution monitoring system)

  • 최영수;박순용;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.828-831
    • /
    • 1996
  • Radiation monitoring system is needed at nuclear power plant and nuclear facility. Manual survey techniques are commonly used, but they are time consuming and somewhat inaccurate. Automatic radiation surveys are very important because it provides significant savings in men-rem and wages. Unmanned, remote automatic radiation measurement system should be small and light-weighted in order to mount on robotic system. The system we have developed consists of detection parts, signal processing part, interface, and software part. Position information is provided by using of a collimator. The measurement process is achieved by the scanning of detector and image processing techniques are used to display radiation levels. We designed collimators, detectors, signal processing circuit, and constructed prototype system. The goal of this system is the mapping of camera image and radiation level distribution.

  • PDF

Evaluation of a Fabricated Charge Sensitive Amplifier for a Semiconductor Radiation Detector

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Lee, Jae-Hyung;Lee, Cheol-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.81-84
    • /
    • 2010
  • A CSA(Charge Sensitive Amplifier) was designed and fabricated for application in a radiation detection system based on a semiconductor detector such as Si, SiC, CdZnTe and etc.. A fabricated hybrid.type CSA was evaluated by comparison with a commercially available CSA. A comparison was performed by using calculation of ENC (Equivalent Noise Charge) and by using energy resolutions of fabricated radiation detectors based on Si. In energy resolution comparison, a fabricated CSA showed almost the same performance compared with a commercial one. In this study, feasibility of a fabricated CSA was discussed.

측정기에 따른 고에너지 X-선의 표면 선량 및 최대 선량 지점 고찰 (Consideration of Surface Dose and Depth of Maximum Dose Using Various Detectors for High Energy X-rays)

  • 이용하;박경란;이종영;이익재;박영우;이강규
    • Radiation Oncology Journal
    • /
    • 제21권4호
    • /
    • pp.322-329
    • /
    • 2003
  • 목적 .: 고에너지 X-선의 표면 선량과 선량보강(build-up) 영역에서의 선량 분포는 일반적으로 방사선 계측에 사용되는 전리함 측정기로는 정확한 선량 분포를 얻기가 매우 어렵다. 본 연구는 고에너지 X-선 선량 계측에 보편적으로 사용되고 있는 여러 측정기를 이용하여 팬톰 표면에서의 흡수선량과 최대 선량 지점(d$_{max}$)을 측정하여 측정기 사이의 정확성을 비교 분석하고, 각 치료 기관에서 보편적으로 사용되는 측정기 중 표면 선량 측정에 적절한 측정장치를 제안하고 그 유용성을 제시하고자 한다. 대상 및 방법 : 본 실험에서는 6 MV와 IS MV X-선에 대해 조사면이 10$\times$10 cm$^{2}$, SSD=100 cm에서 TLD, 팀블형전리함(thimble type ion chamber), 다이오드 검출기, 다이아몬드 검출기와 Markus 평행판 전리함 등을 이용하여 심부선량백분율(percent depth dose: PDD)을 측정하여, 표면 선량(suface dose)과 최대 선량 지점(dnu)을 비교 분석하고, 또한 TLD 측정 시와 동일 조건으로 Monte Cario 계산을 실행하여 TLD의 측정 결과와 비교하였다. 결과: 6 WV와 IS MV X-선에 대해 Markus 평행판 전리함을 이용하여 측정한 표면 선량은 각각 29.31$\%$와 23.36$\%$으로 측정되었으며, TLD는 37.17$\%$와 24.06$\%$, 다이아몬드 검출기는 34.78$\%$와 24.06$\%$, 다이오드 검출기는 38.18$\%$와 27.8$\%$, 팀블형 전리함은 47.92$\%$와 36.06$\%$ 였으며, Monte Cario 계산에 의한 표면 선량 값은 S MV X-선에 대해 TLD 측정 시와 동일한 조건으로 팬톰 내에 가상적인 TLD를 삽입한 경우 36.22$\%$로 실제 측정값 37.17$\%$와 유사하였다. 최대 선량 지점의 깊이는 모든 측정기에서 6 MV X-선에 대하여 14$\~$16 mm, IS MV X-선에서는 27$\~$29 mm사이의 측정기에 따라 작은 차이를 보였다. 결론 : 표면 선량의 경우에는 측정기에 따라 현저한 차이를 보였으며 Markus 평행판 전리함이 사용된 측정기 중가장 정확한 결과를 보였고, 팀블형 전리함의 경우 다른 측정기에 비해 약 10$\%$ 이상 높은 선량을 보여 피부 표면에 가까이 위치한 종양에 대한 방사선 치료 계뵉 시에는 임상에서 가장 보편적으로 사용되고 있는 팀블형 전리함의 선량 값을 그대로 사용하기에는 많은 오류가 발생하므로 가능한 표면 선량 측정에 적절한 측정기를 선택하여 사용하거나 측정기 특성을 고려한 보정이 필요할 것으로 생각된다. 최대 선량 지점(d$_{max}$)의 결과는 모든 측정기에서 비슷한 결과를 나타내고 있어 본 실험에서 사용한 모든 측정기는 그 특성에 상관없이 최대 선량 지점 측정에 사용이 가능함을 알 수 있었다.

Scintillator에 온도 보정 알고리즘을 적용한 A9기반의 디지털 휴대용 방사선 검출기 구현 (Implementation of A9-Based Digital Portable Radiation Detector with the Algorithm of Temperature Compensation in Scintillator)

  • 임익찬;박지오;김영길
    • 한국정보통신학회논문지
    • /
    • 제21권10호
    • /
    • pp.1981-1989
    • /
    • 2017
  • 세계적으로 해운물류 안전 보안체계가 강화됨에 따라 국가물류보안 체계 구축을 위한 해운물류 안전 보안 핵심기술에 관심이 높아지고 있다. 이러한 국제적 정서에 발맞추어, 국내에서도 감마선 핵종 검출을 위한 휴대용 방사선 검출기의 개발이 활발히 이루어지고 있다. 또한 많은 부품이 국산화 되고 있다. 본 논문에서는 기존의 휴대용 방사선 검출기에 사용되던 Pulse Shaping Board를 대신하여 핵종을 판별하고 Scintillator의 온도 변환 효율을 보정하는 알고리즘을 구현하였다. 이를 통해 검사 성능을 향상시키고 소형화 된 A9기반의 디지털 휴대용 방사선 검출기 구현에 대한 연구를 제안한다.

영상처리기반 스테레오 감마선 탐지장치의 고속탐지에 관한 연구 (The Study for the Fast Detection of the Stereo Radiation Detector using the Image Processing)

  • 황영관;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1103-1105
    • /
    • 2015
  • 원전이나 방사선 관련시설에서의 사고발생 또는 노후원전 해체시 누출된 방사능은 조기에 탐지 및 제거해야 대형사고를 방지할 수 있다. 본 논문에서는 방사선원의 빠르고 효율적인 제염작업을 위해 방사선원에 대한 거리, 방향 및 선량정보를 제공할 수 있는 단센서 기반의 스테레오감마선 탐지장치를 구현하였고, 탐지장치의 고속탐지를 위한 알고리즘개발을 수행하였다. 선원에 대한 거리정보를 획득하기 위한 스테레오 구조를 위해 2대의 탐지장치가 필요하지만 장치의 운용을 위하여 단센서 기반의 경량화된 탐지장치를 고안하였고, 스테레오 영상 획득시 탐지시간을 최소화 하기 위하여 관심영역을 추출한 후 해당 영역에 대한 스캔을 통해 탐지 선원에 대한 거리산출 및 영상분포출력을 나타내도록 하였다. 스테레오 획득 시 탐지시간을 기준으로 적용된 알고리즘의 탐지시간은 최대 35%의 시간단축결과를 확인하였다.

  • PDF