Browse > Article
http://dx.doi.org/10.6109/jkiice.2017.21.10.1981

Implementation of A9-Based Digital Portable Radiation Detector with the Algorithm of Temperature Compensation in Scintillator  

Lim, Ik-Chan (Department of Electronic Engineering, Ajou University)
Park, Geo (Department of Electronic Engineering, Ajou University)
Kim, Young-kil (Department of Electronic Engineering, Ajou University)
Abstract
In accordance with the global strengthening of security systems for the safety of the shipping and logistics industry, the development of core technologies within the field has become a key in the establishment of Korea's own national logistics security system. Further in line with these global developments, there is growing attention within Korea to the development of portable radiation detectors capable of detecting gamma ray nuclides. In addition, many parts are becoming localized. In this research, instead of Pulse Shaping Board, which is used in existing portable radiation detectors, we have implemented an Algorithm to discriminate nuclides and correct the temperature conversion efficiency of the scintillator. This paper aims to improve the performance of these devices through the implementation of a temperature conversional algorithm within the scintillator of the A9-based digital portable radiation detector.
Keywords
Scintillator; Radiation; Temperature; Detector;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Efficiency of Transition of Scintillator Based on the Temperature. [Internet]. Available: http://www.lnf.infn.it/esperimenti/gedi/images/Fig04.gif.
2 Radiation Sensor without the Insertion of Light Pipe. [Internet]. Available: http://www.ortec-online.com/download/905-Series.pdf.
3 J. Navarik, "Precise Compact System For Ionizing Radiation Detection And Signal Processing With Advanced Components Integration And Electronic Control," Journal of Electrical Engineering, vol. 55, no. 4, Sep. 2015.
4 T. K. Kwon, "Research of Detection performance enhancement from portable radiation detection platform based on Cortex-A9," Journal of the Korea Institute of Information and Communication Engineering, vol.18, no.6, pp.1488-1493, Jun. 2014.   DOI
5 Conversion gain. [Internet]. Available: http://www.orteconline.com/download/296.pdf.
6 J. G. Seo, "An implementation of portable gamma ray detection platform using Cortex-A8," Journal of the Korea Institute of Information and Communication Engineering, vol. 17, no. 4, pp.1028-1033, Apr. 2013.   DOI
7 Dalvic virtual machine. [Internet]. Available: https://en.wikipedia.org/wiki/Dalvik_(software).
8 Efficiency of Transition of Scintillator Based on the Temperature. [Internet]. Available: http://www.lnf.infn.it/esperimenti/gedi/images/Fig04.gif.
9 K. T. Han, W. J. Yoo, S. H. Shin, D. Y. Jeon, J. Y. Park, B. G. Park, and B. S. Lee, "Development of Fiber-optic Radiation Sensor Using LYSO Scintillator for Gamma-ray Spectroscopy," Journal of Sensor Science and Technology, vol. 21, no. 4, pp.287-292, Apr. 2012.   DOI
10 J. H. Lee, "Research for realization of platform of portable radiation detector using NaI(Tl) Scintillator," Korea Institute of Information and Communication Engineering, vol. 16, no. 10, pp.2323-2328, Oct. 2012.   DOI