• Title/Summary/Keyword: Radiation and Scattering

Search Result 384, Processing Time 0.031 seconds

Preparation and characterization of Zinc Oxide films deposition by (PVD) (PVD 코팅법에 의한 ZnO제조 및 특성)

  • Kim, Sung Jin;Pak, Hunkyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.95.1-95.1
    • /
    • 2010
  • Transparent conducting ZnO films were deposited to apply DSSC Substrate on glass substrates at $500^{\circ}C$ by ionbeam-assisted deposition. Crystallinity, microstructure, surface roughness, chemical composition, electrical and optical properties of the films were investigated as a function of deposition parameters such as ion energy, and substrate temperature. The microstructure of the polycrystalline ZnO films on the glass substrate were closely related to the oxygen ion energy, arrival ratio of oxygen to Zinc Ion bombarded on the growing surface. The main effect of energetic ion bombardment on the growing surface of the film may be divided into two categories; 1) the enhancement of adatom mobility at low energetic ion bombardment and 2) the surface damage by radiation damage at high energetic ion bombardment. The domain structure was obtained in the films deposited at 300 eV. With increasing the ion energy to 600 eV, the domain structure was changed into the grain structure. In case of the low energy ion bombardment of 300 eV, the microstructure of the film was changed from the grain structure to the domain structure with increasing arrival ratio. At the high energy ion bombardment of 600 eV, however, the only grain structure was observed. The electrical properties of the deposited films were significantly related to the change of microstructure. The films with the domain structure had larger carrier concentration and mobility than those with the grain structure, because the grain boundary scattering was reduced in the large size domains compared with the small size grains. The optical transmittance of ZnO films was dependent on a surface roughness. The ZnO films with small surface roughness, represented high transmittance in the visible range because of a decreased light surface scattering. By varying the ion energy and arrival ratio, the resistivity and optical transmittance of the films were varied from $1.1{\times}10^{-4}$ to $2.3{\times}10^{-2}{\Omega}cm$ and from 80 to 87%, respectively. The ZnO film deposited at 300 eV, and substrate temperature of $500^{\circ}C$ had the resistivity of $1.1{\times}10^{-4}{\Omega}cm$ and optical transmittance of 85% in visible range. As a result of experiments, we provides a suggestition that ZnO thin Films can be effectively used as the DSSC substrate Materials.

  • PDF

Study of 4π Compton Suppression Spectrometer by Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 4π 컴프턴 억제 분광기 연구)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.123-129
    • /
    • 2017
  • Compton suppression apparatus using the Compton scattering response, by inhibiting part of the spectrum Compton continuum Compton continuum in the area of the peak analysis of the gamma rays that enables a clearer device. In order to find out the geometry structure of high-purity germanium detector(HPGe) -NaI(TI) and to optimize the effect of movement, Monte Carlo simulation was used to grasp the behavioral characteristics of Compton suppression and compare several layout structures. And applied to the cylinder beaker used for the environmental measurement by using the efficiency according to the distance. For the low-energy source such as 81 keV, the Compton continuum is scarcely developed and the suppression effect is also insignificant because the scattering cross-section of the Compton effect is relatively low. In the spectrum for the remaining energy, it can be seen that the Compton continuum part is suppressed in a certain energy range. Compton suppression effect was not significantly different from positional shift. average reduction factor(ARF) value was about 1.08 for 81 keV and about 1.23 for 1332.4keV energy at the highest value. It can be seen that suppression over the Compton continuum region of the energy spectrum is a more appropriate arrangement. Therefore, it can be applied to various environmental sample measurement through optimized structure.

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.

Effects of Ozone, Cloud and Snow on Surface UV Irradiance (지표 자외선 복사 변화에 미치는 오존 전량, 구름 및 적설 효과)

  • Lee, Yun-Gon;Kim, Jhoon;Lee, Bang-Yong;Cho, Hi-Ku
    • Ocean and Polar Research
    • /
    • v.26 no.3
    • /
    • pp.439-451
    • /
    • 2004
  • Total solar irradiance (750), total UV irradiunce (TUV) and erythemal UV irradiance (EUV) measured at King Sejong station $(62.22^{\circ}S,\;58.78^{\circ}W)$ in west Antarctica have been used together with total ozone, cloud amount and snow cover to examine the effects of ozone, cloud and snow surface on these surface solar inadiunce over the period of 1998-2003. The data of three solar components for each scan were grouped by cloud amount, n in oktas $(0{\leq}n<3,\;3{\leq}n<4,\;4{\leq}n<5,\;5{\leq}n<6,\;6{\leq}n<7\;and\;7{\leq}n<8)$ and plotted against solar zenith angle (SZA) over the range of $45^{\circ}\;to\;75^{\circ}$. The radiation amplification factor (RAE) is used to quantify ozone effect on EUV. RAF of EUV decreases from 1.51 to 0.94 under clear skies but increases from 0.94 to 1.85 under cloudy skies as SZA increases, and decreases from 1.51 to 1.01 as cloud amount increases. The effects of cloud amount and snow surface on EUV are estimated as a function of SZA and cloud amount after normalization of the data to the reference total ozone of 300 DU. In order to analyse the transmission of solar radiation by cloud, regression analyses have been performed for the maximum values of solar irradiance on clear sky conditions $(0{\leq}n<3)$ and the mean values on cloudy conditions, respectively. The maximum regression values for the clear sky cases were taken to represent minimum aerosol conditions fur the site and thus appropriate for use as a normalization (reference) factor for the other regressions. The overall features for the transmission of the three solar components show a relatively high values around SZAs of $55^{\circ}\;and\;60^{\circ}$ under all sky conditions and cloud amounts $4{\leq}n<5$ and $5{\leq}n<6$. The transmission is, in general, the largest in TUV and the smallest in EUV among the three components of the solar irradiance. If the ground is covered with snow on partly cloudy days $(6{\leq}n<7)$, EUV increases by 20 to 26% compared to snow-free surface around SZA $60^{\circ}-65^{\circ}$, due to multiple reflections and scattering between the surface and the clouds. The relative difference between snow surface and snow-free surface slowly increases from 9% to 20% as total ozone increases from 100 DU to 400 DU under partly cloud conditions $(3{\leq}n<6)$ at SZA $60^{\circ}$. The snow effects on TUV and TSO are relatively high with 32% and 34%, respectively, under clear sky conditions, while the effects changes to 36% and 20% for TUV and TSO, respectively, as cloud amount increases.

Evaluation of photon radiation attenuation and buildup factors for energy absorption and exposure in some soils using EPICS2017 library

  • Hila, F.C.;Javier-Hila, A.M.V.;Sayyed, M.I.;Asuncion-Astronomo, A.;Dicen, G.P.;Jecong, J.F.M.;Guillermo, N.R.D.;Amorsolo, A.V. Jr.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3808-3815
    • /
    • 2021
  • In this paper, the EPICS2017 photoatomic database was used to evaluate the photon mass attenuation coefficients and buildup factors of soils collected at different depths in the Philippine islands. The extraction and interpolation of the library was accomplished at the recommended linear-linear scales to obtain the incoherent and total cross section and mass attenuation coefficient. The buildup factors were evaluated using the G-P fitting method in ANSI/ANS-6.4.3. An agreement was achieved between XCOM, MCNP5, and EPICS2017 for the calculated mass attenuation coefficient values. The buildup factors were reported at several penetration depths within the standard energy grid. The highest values of both buildup factor classifications were found in the energy range between 100 and 400 keV where incoherent scattering interaction probabilities are predominant, and least at the region of predominant photoionization events. The buildup factors were examined as a function of different soil silica contents. The soil samples with larger silica concentrations were found to have higher buildup factor values and hence lower shielding characteristics, while conversely, those with the least silica contents have increased shielding characteristics brought by the increased proportions of the abundant heavier oxides.

Shielding design and analyses of the cold neutron guide hall for the KIPT neutron source facility

  • Zhong, Zhaopeng;Gohar, Yousry
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.989-995
    • /
    • 2018
  • Argonne National Laboratory of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have cooperated on the development, design, and construction of a neutron source facility. The facility was constructed at Kharkov, Ukraine, and its commissioning process is underway. The facility will be used for researches, producing medical isotopes, and training young nuclear specialists. The neutron source facility is designed with a provision to include a cryogenically cooled moderator system-a cold neutron source (CNS). This CNS provides low-energy neutrons, which will be used in the scattering experiment and material structures analysis. Cold neutron guides, coated with reflective material for the low-energy neutrons, will be used to transport the cold neutrons to the experimental site. The cold neutron guides would keep the cold neutrons within certain energy and angular space concentrated inside, while most of the gamma rays and high-energy neutrons are not affected by the cold neutron guides. For the KIPT design, the cold neutron guides need to extend several meters outside the main shield of the facility, and curved guides will also be used to remove the gamma and high-energy neutron. The neutron guides should be installed inside a shield structure to ensure an acceptable biological dose in the facility hall. Heavy concrete is the selected shielding material because of its acceptable performance and cost. Shield design analysis was carried out for the CNS guide hall. MCNPX was used as the major computation tool for the design analysis, with neutron and gamma dose calculated separately. Weight windows variance reduction technique was also used in the shield design. The goal of the shield design is to keep the total radiation dose below the $5.0{\mu}Sv/hr$ guideline outside the shield boundary. After a series of iterative MCNPX calculations, the shield configuration and parameters of CNS guide hall were determined and presented in this article.

Gamma ray attenuation behaviors and mechanism of boron rich slag/epoxy resin shielding composites

  • Mengge Dong;Suying Zhou ;He Yang ;Xiangxin Xue
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2613-2620
    • /
    • 2023
  • Excellent thermal neutron absorption performance of boron expands the potential use of boron rich slag to prepare epoxy resin matrix nuclear shielding composites. However, shielding attenuation behaviors and mechanism of the composites against gamma rays are unclear. Based on the radiation protection theory, Phy-X/PSD, XCOM, and 60Co gamma ray source were integrated to obtain the shielding parameters of boron rich slag/epoxy resin composites at 0.015-15 MeV, which include mass attenuation coefficient (µt), linear attenuation coefficient (µ), half value thickness layer (HVL), electron density (Neff), effective atomic number (Zeff), exposure buildup factor (EBF) and exposure absorption buildup factor (EABF).µt, µ, HVL, Neff, Zeff, EBF and EABF are 0.02-7 cm2/g, 0.04-17 cm-1, 0.045-20 cm, 5-14, 3 × 1023-8 × 1023 electron/g, 0-2000, and 0-3500. Shielding performance is BS4, BS3, BS3, BS1 in descending order, but worse than ordinary concrete. µ and HVL of BS1-BS4 for 60Co gamma ray is 0.095-0.110 cm-1 and 6.3-7.2 cm. Shielding mechanism is main interactions for attenuation gamma ray by BS1-BS4 are elements with higher content or higher atomic number via Photoelectric Absorption at low energy range, and elements with higher content via Compton Scattering and Pair Production in Nuclear Field at middle and higher energy range.

Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography (흉부 전·후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향)

  • Kim, Jong-Seok;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.295-300
    • /
    • 2021
  • This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

A Study on the Analysis of the Microstrip Line by Using Inner Source at the FDTD Method (유한차분 시간영역 해석법에 내부전원을 이용한 마이크로스트립 선로 해석에 관한 연구)

  • 윤성현;정수길;손창수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.5
    • /
    • pp.567-577
    • /
    • 1998
  • When continuous and discontinuous microstrip is analyzed with FDTD(Finite Difference Time Domain) method, we used Berenger's 3D-PML as absorbing boundary condition, and IST(Inner Source Technique) was used for source excitation instead of front excitation that is existing method. In the case using IST, we have observed that analyzed characteristic is not affected by the reduced computational domain of the side and top face in which evanescent field and radiation field is exist. Also, if we control the position of the inner source, we could effectively reject the influence of the reflective wave by mean of imperfective boundary condition. In this paper, by using IST, we have calculated dispersive characteristic and characteristic impedance of the microstrip. And we have calculated magnitude and phase of the scattering coefficient, and obtained equivalent circuit of the open microstrip end.

  • PDF

Effective Design of the Broadband Horn Antenna Using Multi-mode Network Analysis (다중모드 회로망 분석을 이용한 광대역 혼 안테나의 효율적인 설계)

  • Moon, Jung-Ick;Cho, In-Gui;Kim, Sung-Min
    • Journal of IKEEE
    • /
    • v.16 no.4
    • /
    • pp.297-303
    • /
    • 2012
  • This paper proposes the effective design procedure for a broadband, double-ridged horn antenna for evaluating the performance of the RF energy harvesting system with a multi-band rectenna. Using multi-mode network analysis, the higher-mode scattering parameters of the transition and horn were acquired and applied to the antenna design, respectively. As a result, the computing time could be reduced and the calculated VSWR(voltage standing wave ratio) of the antenna was very similar to the analyzed result using fully electromagnetic simulation. And there was also good agreement between the simulated and measured results. The designed broadband antenna has a bandwidth of 660~6360 MHz and 6~13.7 dBi peak radiation gain.