• 제목/요약/키워드: Radiation Shielding

검색결과 607건 처리시간 0.028초

Review of Shielding Evaluation Methodology for Facilities Using kV Energy Radiation Generating Devices Based on the NCRP-49 Report

  • Na Hye Kwon;Hye Sung Park;Taehwan Kim;Sang Rok Kim;Kum Bae Kim;Jin Sung Kim;Sang Hyoun Choi;Dong Wook Kim
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.53-62
    • /
    • 2022
  • In this study, we have investigated the shielding evaluation methodology for facilities using kV energy generators. We have collected and analysis of safety evaluation criteria and methodology for overseas facilities using radiation generators. And we investigated the current status of shielding evaluation of domestic industrial radiation generators. According to the statistical data from the Radiation Safety Information System, as of 2022, a total of 7,679 organizations are using radiation generating devices. Among them, 6,299 facilities use these devices for industrial purposes, which accounts for a considerable portion of radiation. The organizations that use these devices evaluate whether the exposure dose for workers and frequent visitors is suitable as per the limit regulated by the Nuclear Safety Act. Moreover, during this process, the safety shields are evaluated at the facilities that use the radiation generating devices. However, the facilities that use radiating devices having energy less than or equal to 6 MV for industrial purposes are still mostly evaluated and analyzed according to the National Council on Radiation Protection and Measurements 49 (NCRP 49) report published in 1976. We have investigated the technical standards of safety management, including the maximum permissible dose and parameters assessment criteria for facilities using radiation generating devices, based on the NCRP 49 and the American National Standards Institute/Health Physics Society N.43.3 reports, which are the representative reports related to radiation shielding management cases overseas.

전기로 산화슬래그 골재를 활용한 중량 콘크리트의 단위 용적 중량 변화에 따른 X-선 차폐 성능 비교 (Comparison of X-ray Shielding Performance according to the Weight of unit volume of Heavy Weight Concrete Utilizing Electric Arc Furnace Oxidizing Slag.)

  • 임희섭;이한승;최재석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.35-36
    • /
    • 2013
  • Electric arc furnace oxidizing slag from massively produced steel slag has been used in road bases and subbases, hot mix asphalt, and landfill. Electric arc furnace oxidizing slag contains iron (15%~30%) and has a high density of 3.0~3.7 ton/m3. Depending on the type and amount of concrete aggregates, the radiation-shielding characteristics can vary. Therefore, aggregates of electric arc furnace oxidizing slag can be considered for the production of radiation-shielding concrete. The experimental design of this study is experiments on Compressive strength experiments, X-ray irradiation experiments, and experiments related to the unit volume weight were carried out on hardened concrete. This experiment compared the performance evaluation of radiation shielding of concrete using electric arc furnace oxidizing slag.

  • PDF

Bentonite based ceramic materials from a perspective of gamma-ray shielding: Preparation, characterization and performance evaluation

  • Asal, Sinan;Erenturk, Sema Akyil;Haciyakupoglu, Sevilay
    • Nuclear Engineering and Technology
    • /
    • 제53권5호
    • /
    • pp.1634-1641
    • /
    • 2021
  • Exposure to gamma-rays is hazardous for humans and other living beings because of their high penetration through the materials. For this reason, shielding materials (usually lead, copper and stainless steel) are used to protect against gamma rays. This study's objective was to prepare ceramic materials for gamma radiation shielding by using different natural bentonite clays. Gamma-ray attenuation performances of the prepared shielding materials at different thicknesses were investigated and evaluated for different gamma-ray energies from different standard point gamma radiation sources (251Am, 57Co, 137Cs, 60Co, and 88Y). The mass and linear attenuation coefficients of the prepared ceramics vary between 0.238 and 0.443 cm2 g-1 and between 0.479 and 1.06 cm-1, respectively, depending on their thicknesses. Results showed that these materials could be prioritized because of their evidential properties of gamma radiation protection in radiation applications.

EVALUATION OF BRACHYTHERAPY FACILITY SHIELDING STATUS IN KOREA OBTAINED FROM RADIATION SAFETY REPORTS

  • Keum, Mi Hyun;Park, Sung Ho;Ahn, Seung Do;Cho, Woon-Kap
    • Nuclear Engineering and Technology
    • /
    • 제45권5호
    • /
    • pp.695-700
    • /
    • 2013
  • Thirty-eight radiation safety reports for brachytherapy equipment were evaluated to determine the current status of brachytherapy units in Korea and to assess how radiation oncology departments in Korea complete radiation safety reports. The following data was collected: radiation safety report publication year, brachytherapy unit manufacturer, type and activity of the source that was used, affiliation of the drafter, exposure rate constant, the treatment time used to calculate workload and the HVL values used to calculate shielding design goal values. A significant number of the reports (47.4%) included the personal information of the drafter. The treatment time estimates varied widely from 12 to 2,400 min/week. There was acceptable variation in the exposure rate constant values (ranging between 0.469 and 0.592 ($R{\cdot}m^2/Ci{\cdot}hr$), as well as in the HVLs of concrete, steel and lead for Iridium-192 sources that were used to calculate shielding design goal values. There is a need for standard guidelines for completing radiation safety reports that realistically reflect the current clinical situation of radiation oncology departments in Korea. The present study may be useful for formulating these guidelines.

고온 및 방사선이 중성자 차폐재의 열적, 역학적 및 차폐능 특성에 미치는 영향 (Effects of High Temperature and Radiation on the Properties of Thermal, mechanical and Shielding Ability of Neutron Shielding Materials)

  • 조수행;홍순석;정명수;도재범;박현수
    • 한국재료학회지
    • /
    • 제9권4호
    • /
    • pp.404-408
    • /
    • 1999
  • Effects of heating time and radiation under high temperature on the properties of thermal, mechanical and shielding ability of modified (KNS-101), hydrogenated bisphenol-A(KNS-201) type epoxy resin and phenol-novolac(KNS-301) type epoxy resin based neutron shielding materials that are used for shipping casks for radioactive material have been investigated. At early stages, the offset temperatures of KNS-101, KNS-201 and KNS-301 increased with the heating time under high temperature, but it was rarely affected by the heating time in the later stages. In addition, the thermal conductivities of KNS-101 and KNS-201 decreased with heating time, but that of KNS-301 increased with the heating time. On the contrary, the thermal expansion coefficients of neutron shielding materials decreased with heating time. At the high temperature, the tensile strength and flexural strength of the shielding materials decreased with heating time. On the contrary, the thermal expansion coefficients of neutron shielding materials decreased with heating time. At the high temperature, the tensile strength and flexural strength of the shielding materials of KNS-101 and KNS-301 increased with heating time, but those of KNS-201 decreased with heating time. The shielding ability of neutron shielding materials slightly increased with the radiation dose, and shielding abilities of shielding materials of KNS-101 and KNS-201 were affected to a more extent than that of KNS-301 by radiation dose under high temperature.

  • PDF

계란 껍데기를 이용한 융합 의료방사선 차폐시트의 가능성 검증 (Verification of the Possibility of Convergence Medical Radiation Shielding Sheet Using Eggshells)

  • 김선칠
    • 한국융합학회논문지
    • /
    • 제12권6호
    • /
    • pp.33-38
    • /
    • 2021
  • 경량의 의료방사선 차폐시트를 제작하기 위해 새로운 차폐소재를 검토하였다. 가정에서 음식물 쓰레기로 버려지는 계란 껍데기 분말을 고분자 물질과 혼합하여 차폐재료의 가능성을 검증하고자 하였다. 기존의 경량 소재는 친환경의 조건을 만족하지만 주 재료 정제과정의 비용으로 인해 차폐시트 제작의 경제성에 어려움이 있다. 본 연구는 가정용 폐기물인 계란 껍데기를 이용하여 이러한 문제점을 해결하고자 한다. 고분자 물질인 HDPE를 이용하여 3 mm 두께의 차폐시트를 제작하였으며, 차폐시트 단면 내의 입자 분포상태도 분석하였다. 입자의 모양은 대체로 거칠게 구성되어 입자 간 공극이 있었으며, 단위 면적당 무게는 평균 1.5 g/cm2 로 나타났다. 차폐성능은 저에너지 영역에서는 20%대, 고에너지 영역에서는 10%대의 차폐성능을 보여 저선량 의료방사선 차폐시트의 재료로 가능성을 보여주었다.

PET 검사 프러시저별 방사선 차폐기구의 유용성 평가 (The Usefulness Evaluation of Radiation Shielding Devices in PET Scan Procedures)

  • 김영선;서명덕;이완규;정요천;김상욱;서일택;송재범
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.65-76
    • /
    • 2010
  • 1994년 PET의 국내 도입 이후, 현재까지 양적으로나 질적으로 많은 발전이 있었다. 하지만 이와 함께 방사성의약품의 사용량 또한 급증하면서 검사에 있어서 가장 중요한 역할을 하는 방사선사의 개인피폭선량이 높아지는 요인으로 작용했던 것이 사실이다. 식품의약품안전청의 피폭선량관리센터에서 발표한 자료에 따르면 2008년도 방사선작업종사자의 전체 평균 피폭선량은 0.67 mSv였고, 방사선사 전체 피폭선량은 1.33 mSv로 해마다 감소하는 것으로 나타났다. 설문결과를 살펴보면 PET 검사 담당자의 평균피폭선량은 1.69 mSv였고, 1.0 mSv를 초과하는 구간에 75.3%의 방사선사가 포함되어 있었다. 이는 고 노출구간에 속한 방사선사의 비율이 높다는 것을 의미하므로, 피폭저감을 위한 노력이 요구된다. 본 연구에서는 설문조사를 통하여 PET 검사 프러시저별 차폐기구의 활용에 따른 방사선 피폭 정도를 TLD 수치를 이용하여 분석하고, 실험을 통하여 각 차폐기구의 차폐율을 측정함으로써, 그 효용성을 입증하고 적합한 차폐방법을 강구하고자 하였다. 방사선 피폭의 위험에 대해서 어느 누구보다 잘 인지하고 있는 방사선사임에도 불구하고 안이하게 생각하는 경향이 있었다. 설문결과를 살펴보면 방사선 피폭의 위험성에 대한 인식도와 피폭선량과는 크게 관련이 없었으며, 차폐기구의 활용도에 따라서는 피폭선량의 차이가 확연하게 나타났다. 프러시저 중 피폭선량에 가장 많은 영향을 미치는 단계는 방사성의약품의 투여였으며, 투여시 차폐방법에 따라 이동시 차폐방법도 달라졌다. 투여 시 차폐기구 사용현황을 보면 Both shield는 58.5%, L-Block은 20%, Syringe shield는 9%, No shield는 12.3%를 차지하였다. TLD 수치에 따른 투여 시 차폐방법은 수치가 낮을수록 Both shield와 L-block을 많이 사용하였으며, 수치가 높을수록 Syringe shield와 차폐를 시행하지 않는 경우가 많았다. 실험결과, 가장 이상적인 차폐방법은 분배 시엔 L-block을 사용하고, 이동시엔 Syringe shield carrier를 사용하며, 투여 시엔 L-block과 Syringe shield를 함께 사용하는 것이다. 환자 포지셔닝 시 Apron의 차폐율은 평균 16.4%로 차폐효과가 있다. PET 검사를 시행함에 있어서 강한 실천의지를 가지고 프러시저별로 차폐기구를 적극 활용한다면 점증하는 방사선사의 피폭 수준을 크게 감소시킬 수 있을 것으로 판단된다.

  • PDF

Experimental investigation of zinc sodium borate glass systems containing barium oxide for gamma radiation shielding applications

  • Aboalatta, A.;Asad, J.;Humaid, M.;Musleh, H.;Shaat, S.K.K.;Ramadan, Kh;Sayyed, M.I.;Alajerami, Y.;Aldahoudi, N.
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3058-3067
    • /
    • 2021
  • Sodium zinc borate glasses doped with dysprosium and modified with different concentrations of barium oxide (0-50 mol %) were fabricated using the melting quenching technique. The structural properties of the prepared glass systems were characterized using XRD and FTIR methods. The absorption spectra of the prepared glasses were measured to determine their energy gap and their related optical properties. The density of the glasses and other physical parameters were also reported. Additionally, with the help of Photon Shielding and Dosimetry (PSD) software, we investigated the radiation shielding parameters of the prepared glass systems at different energy values. It was found that an increase in the density of the glasses by increasing the concentration of BaO significantly improved the gamma ray shielding ability of the samples. For practical results, a compatible irradiation set up was designed to check the shielding capability of the obtained glasses using a gamma ray source at 662 keV. The experimentally obtained results strongly agreed with the data obtained by PDS software at the same energy. These results demonstrated that the investigated glass system is a good candidate for several radiation shielding applications when comparing it with other commercial shielding glasses and concretes.

Tungsten eyeball shield block의 임상적용에 관한 고찰 (Dosimetric characteristics of an independent collimator system using measurements performed quarter fields.)

  • 정덕양;이병구;황웅구
    • 대한방사선치료학회지
    • /
    • 제14권1호
    • /
    • pp.89-94
    • /
    • 2002
  • I. 목적 : Sebaceous gland carcinoma, Squamouse cell ca., basal cell ca., low grade MALToma 등에서 전자선을 이용하여 eyelid 치료시 안구의 선량은 될 수 있는 한 최소선량으로 관리되어야 한다. 그러나 upper나 lower eyelid 전부를 포함하는 조사면은 치료후 백내장등의 심각한 부작용을 만들어 낼 수 있다. 본원에서는 상용되는 Tungsten eyeball shielding block과 기존의 lead block에 의한 차폐시 안구의 선량을 비교하여 Tungsten eyeball shielding block의 유용성에 대해 평가해 보고자한다. 2. 재료 및 방법: 시판되고 있는 BOLX-I 물질을 이용하여 모형안구를 제작하고 안구의 6곳 주요지점을 선정한 후 TLD chip을 이용하여 주로 사용되는 6MeV와 9MeV electron beam의 선량을 측정, Tungsten eyeball shielding block과 lead block의 선량을 비교하였다. 3. 결과 : Tungsten eyeball shielding block의 사용이 안구의 주요 지점인 각막, 망막, 시신경부위의 선량을 lead block사용 때보다 $90\%$에서 $50\%$의 감소효과가 있었다. 4. 결론 : Tungsten eyeball shielding block은 6MeV 전자선 치료시 보다 뛰어난 차폐효과를 보여 임상에서의 유용성이 인정되었다. 그러나 안구에 삽입시 환자의 고통과 불쾌감을 줄일 수 있는 방안이 모색되어야 하는 숙제를 남겼다.

  • PDF

MCNP코드 시스템을 이용한 차폐물 geometry에 따른 결과 변화에 대한 연구 (Changes according to the geometry of the shield using MCNP code system)

  • 강기병;이남호;황영관
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.1031-1033
    • /
    • 2013
  • 후쿠시마와 같은 방사선 누출 사고 시 방사선원의 위치를 찾는 일은 방사선 방호 뿐만 아니라 원전 사고의 조속하고 안전한 처리를 위해서도 중요하다. 방사선원의 3차원 위치 탐지는 기존에 방사선 탐지기의 2차원적 방사선 위치 탐지기능에 방사선원의 거리정보까지 추가 제공할 수 있어 방사선 오염원의 제거 및 제염작업에 결정적 역할을 할 수 있다. 본 연구에서는 반도체 센서에 기반한 듀얼(Dual) 방사선 탐지기를 이용한 방사선원 3차원 가시장치 개발 연구의 일환으로 방사선 센서부의 효율적 차폐체 구조설계에 관한 결과를 논하였다. 고하중의 텅스텐 또는 납 차폐체를 MCNP기반으로 최적구조로 설계함으로써 경량의 고효율 방사선원 위치탐지기 구현을 시도하였고, 이를 위해 차폐체의 구조와 두께, 그리고 콜리메이터에 형상의 다양한 변수모델에 대한 방사선 차폐시뮬레이션을 수행하였다. 본 연구의 결과는 향후 실리콘 센서기반의 소형 경량의 3차원 방사선원 탐지 및 가시화 연구에 활용될 예정이다.

  • PDF