• Title/Summary/Keyword: Radiation Safety Management

Search Result 325, Processing Time 0.02 seconds

Necessity of Developing University Radiology Curriculum for Veterinary Hospital Radiological Technologists - D University Case Focusing - (동물병원 방사선사를 위한 대학 방사선학과 교육과정 개발 필요성 - D 대학 사례 중심으로 -)

  • Won-Jeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.203-212
    • /
    • 2024
  • The purpose of this study was to survey by the veterinary hospital Specialists (VHSs) and radiology students (RSs) for radiology curriculum development veterinary hospital (VH), and for veterinary hospital radiological technologists (VHRTs). VHSs were surveyed to regarding the basic information and radiological examination training, radiological examination experience, anatomy physiology, radiation safety management training, radiation biology training. RSs were surveyed to regarding the basic information and career paths, VH awareness, and VH-related department environments. The survey results were quantitatively entered into Excel and then analyzed using the SPSS ver. 26.0. The students were aged by 22.6 years old, and out of 171 students, male and female were 92 and 79 espectively. In employment career paths, 62.6% of all subjects responded that employment prospects at medical institutions were good. Employment prospects outside of medical institutions, VH had the highest number of students. Of the 83 students who responded that they wanted to work at a VH, 64 students liked animals, and 47 students the high potential for advancement. Of the 159 students who responded that there is potential for development of VH, 96.2% responded that it was due to the increase in companion animals. In the VH-related department environment, 94.7% responded that there was no related equipment, and 72.5% responded that the department needed to open animal care courses and 82.5% anatomy and physiology courses. 76.6% responded that they would be willing to take animal-related courses if they were offered. Among the 20 VHSAs, 4 had no experience in radiological examination of animals, 2 VHRTs, and 2 others. There were 7 people who had not received training in animal radiography, and 2 VHRTs had not received training in animal care and animal anatomy and physiology. This study is expected to be helpful in developing a radiology curriculum for VHRTs in the future.

Consideration of a Bacteria Contamination Management in the Dispensation of 99mTc Radiopharmaceutical (테크네슘 방사성의약품의 조제와 분배 과정에서 오염균에 대한 고찰)

  • Choi, Do Chul;Gim, Yeong Su;Jo, Gwang Mo;Gim, Hui Jeong;Seo, Han Gyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.84-87
    • /
    • 2018
  • Purpose The radiopharmaceutical used in the nuclear medicine department is used only for the specific patient according to the prescription or instruction of the doctor without selling, so it is dispensed and it is distributed and used for the examination. Radiopharmaceuticals administered to patients should be managed appropriately as well as radiation safety management during dispensation. The purpose of this study is to investigate microbial contamination during dispensation of radiopharmaceuticals Materials and Methods This study distinguished between general workbench and clean workbench and performed three tests. First, microbial cultivation test of radiopharmaceutical prepared and dispensed in general workbenches and sterile workbenches were carried out five times, respectively. The second test was performed settle plate method three times before and after the use of the exhaust filter. Finally, Adenosine Triphosphate (ATP) measurement was performed in each workbench to measure bacterial counts. In addition, ATP measurement were carried out by designating locations and items that may be contaminated during dispensation. Results In the microbial culture test, no microorganisms were detected in both samples. In the settle plate method, it was detected without using of the exhaust filter in a general workbench once. In the ATP measurement test, it was measured at the level of 400 RLU or less, which is the standard value of contamination, in both workbenches surface. In additional ATP measurement test, the refrigerator handle in the distribution room was measured above the reference value of 1217 RLU, the vacuum vial shield of the Tech Generator at 435 RLU, and the syringe holder at 1357 RLU. After environmental disinfection, the results were reduced to 311 RLU, 136 RLU, and 291 RLU. Conclusion No contamination by bacteria was found in both workbenches. However, microbial contamination may occur if the use of an exhaust filter or proper hand hygiene is not achieved. Regular inspections and management for aseptic processing themselves will be necessary.

Study on the determination methods of the natural radionuclides (238U, 232Th) in building materials and processed living products (실내 건축자재 및 생활 가공제품 중 천연방사성핵종(238U, 232Th)의 농도 평가를 위한 분석법 연구)

  • Lee, Hyeon-Woo;Lim, Jong-Myoung;Lee, Hoon;Park, Ji-Young;Jang, Mee;Lee, Jin-Hong
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.149-160
    • /
    • 2018
  • A large number of functional living products are being produced for eco-friendly or health-promoting purposes. In the manufacturing process, such products could be adulterated with raw materials with high radioactivity, such as monazite and tourmaline. Thus, it is essential to manage raw materials and products closely related to the public living. For proper management, an accurate radioactivity data of the processed products are needed. Therefore, it is essential to develop a rapid and validated analytical method. In this study, the concentration of the radioactive $^{238}U$ and $^{232}Th$ in building materials (e.g., tile, cement, paint, wall paper, and gypsum board) and living products (e.g., health products, textiles, and minerals) were determined and compared by ED-XRF and ICP-MS. By comparing the results of both methods, we confirmed the applicability of the rapid screening and precise analysis of ED-XRF and ICP-MS. In addition, $^{238}U$ and $^{232}Th$ levels were relatively lower in building materials than in living products. Particularly, $^{232}Th$ content in 6 of 47 living products exceeded (maximum $8.2Bq{\cdot}g^{-1}$) the standard limit of $^{232}Th$ content in raw material ($1.0Bq{\cdot}g^{-1}$).

The Clinical Usefulness of Transbronchial Lung Biopsy in Critically III Patients with Pulmonary Infiltrates of Uncertain Etiology (폐 침윤과 호흡부전을 동반한 중환자에서 경기관지폐생검의 임상적 유용성에 관한 연구)

  • Jang, Eun-Ha;Koh, Youn-Suck;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Go, Yun-Seok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.2
    • /
    • pp.236-245
    • /
    • 2000
  • Background: Transbronchial lung biopsy(TBLB) has known to yield useful information for pulmonary infiltrates of uncertain etiology, However, its safety and usefulness have not been conclusive in the critically ill patients with respiratory failure. Moreover, TBLB has not been recommended for patients with mechanical ventilation. This study was conducted to investigate the diagnostic values and risks of Will performed on critically ill patients at bedside to obtain information on the pulmonary infiltrate of unknown etiology. Methods: Twenty patients(21 admissions with 23 cases) with diffuse pulmonary infiltrates who were treated in a medical intensive care unit of a tertiary referral hospital from January 1994 to May 1998, were enrolled for the study. Their medical records were retrospectively reviewed. TBLB was opted when a noninvasive diagnostic work-up failed to reveal the cause for the pulmonary infiltrate. The procedure was performed at patients' bedside without assistance of fluoroscopy. Bronchial washing or bronchoalveolar lavage was performed on the same pulmonary segment before performing TBLB. Results: Adequate specimens were obtained in 18 cases(78%). TBLB provided a specific diagnosis in two cases. The results of TBLB suggested the underlying etiology in 9 cases; bacterial pneumonitis(4), hypersensitivity pneumonitis(1), polymyositis(1), radiation fibrosis(1), idiopathic pulmonary fibrosis(1), and BOOP(1). Therapeutic decisions were altered in 11 cases(47.8%) based on the TBLB results. Pneumocystis carinii was found in the BAL fluid of another case. Ten patients with a therapeutic change and ten patients without a management change had mortality rates of 40% and 80%, respectively. The APACHE III scores were significantly higher in patients with complications($72.8{\pm}21.8$) compared with those without complications ($48.3{\pm}18.9$)(p<0.05). The complication rates were higher in those with mechanical ventilation(50%) than in those without Mechanical ventilation(33%), but the difference was not statistically significant(p=0.3). Conclusions: TBLB may be a useful diagnostic option for critically ill patients with unknown cause of pulmonary infiltrates. However, it should be cautious be used with care for patients with mechanical ventilation or for severely ill patients.

  • PDF

An Activation Analysis of Target("used H218O") for 18FDG Synthesis (18FDG 생산용 타겟("사용 후 H218O")의 방사화 분석)

  • Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.213-219
    • /
    • 2013
  • Currently, about 35 cyclotrons have been operating in South Korea. Most of them are mainly used for the synthesis of radiopharmaceuticals such as $^{18}FDG$, which is a cancer tracer for nuclear medicine. Highly enriched $H_2{^{18}}O$ containing up to 98% of $^{18}O/O$ isotope ratio is used as the target for $^{18}F$ production. The price of the highly enriched $H_2{^{18}}O$ ranges 60~70 USD/g, and all of them have been imported from foreign country in spite of the very expensive price. The target (enriched $H_2{^{18}}O$) is non-radioactive before the proton beam irradiation. But, the post-irradiation target (used $H_2{^{18}}O$) must be managed following the National Radiation Safety Regulations, because it turns into radioactive by the radioactivation of the impurities within the target. Recently, nevertheless of the fast increasing amount of used $H_2{^{18}}O$ in accordance with the increasing number of nuclear medicine cases, any activation analysis on the used $H_2{^{18}}O$ have been conducted yet in Korea. In this research, activation analysis have been conducted to confirm the specific radioactivity(Bq/g) of each radioisotopes within the used $H_2{^{18}}O$. The analysis have been done on the 3 of 20g samples collected from the used $H_2{^{18}}O$ storages at different cyclotron centers. Based on the results, it was confirmed that the "used $H_2{^{18}}O$" contains gamma emitters such as $^{56}Co$, $^{57}Co$, $^{58}Co$, and $^{54}Mn$ as well as the considerable amount of beta emitter $^3H$. It was also confirmed that the only one sample contained over exemption level of gamma emitters while the specific activity of tritium was lower than the exemption level in all samples. The specific activity of radioisotopes were measured different levels in the samples depending on the elapsed time after irradiation. Further study on the activation of the "used $H_2{^{18}}O$" is definitely necessary, nevertheless the as-is results of this research must be useful in establishing a rational "used $H_2{^{18}}O$" management protocol.