• Title/Summary/Keyword: Radiation Quality Factor

Search Result 162, Processing Time 0.026 seconds

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

Inactivation of Escherichia coli in Surface Water of Saturated Soil with the Pig Manure-based Liquid Fertilizers by Ultraviolet Radiation (자외선에 의한 가축분뇨 액비 시용 논 표면수 중 대장균 사멸율 변화)

  • Kim, Min-Kyeong;Jung, Goo-Bok;Hong, Seung-Chang;Kang, Seong-Soo;Kwon, Soon-Ik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.368-370
    • /
    • 2011
  • Liquid manure fertilizer drived from pig slurry is a valuable source of nutrients for crop production. However, there is no study for environmental assessment regarding microbial quality to apply liquid manure fertilizer. Therefore, this study aimed at quantifying the level of environmental impact on fecal coliform (Escherichia coli or E. coli ) survival in saturated soil such as paddy field. Surface water samples were collected up to 168 and 11 hours under natural sunlight and artificial ultraviolet radiation, respectively. The inactivation rate of E. coli under natural sunlight increased gradually after 48 hours. However, the inactivation rate of E. coli under artificial ultraviolet radiation increased linearly over time. Our findings suggested that the ultraviolet radiation is the limited factor on E. coli survival in surface water of saturated soil. This result will provide useful and practical guideline to applicators of agricultural soil in deciding appropriate handling and time frames for preventing pollution of water quality for sustainable agriculture.

The Experiment of Grid Characteristics for High-voltage Radiography of Chest (흉부촬영시 관전압과 선질에 따른 적절한 격자의 선택을 위한 실험)

  • Kim, Jung-Min;Ahn, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.31-36
    • /
    • 1992
  • Grids can improve the diagnostic quality of chest radiography by trapping the greater part of scattered radiation thus providing more detailed. chest radiographic images. It is most effective mathod of reduce the scatter ratio but must increase the expour factor. The benefit of use of grid is improve the contrast and the loss is increase of patient dose. In chest radiography especially hard quality high voltage radiography it will have to be considered to select the optimum grid with view point of benefit and loss. In this experiment, author got some result of characteristics about 4 different grids with film method. 1. There was no difference the scatter ratio in case of no grid and the scatter ratio was about 60%. 2. 16 : 1 grid was excellent of scatter reduction factor in high voltage chest radiography, next was 10 : 1, CROSS, MICRO FINE grid have low scatter reduction rate compare to 16:1, 10:1 grid. 3. The bucky factor of CROSS grid in accordance of kVp was find out the highest in 4 grids, on the contraly 10 : 1 grid was profitable to the exposure does. 4. With careful consideration in the point of scatter reducion rate and bucky factor, author suggest the 10 : 1 linear grid on the use of chest radiography in $80{\sim}120\;kVp$, 16 : 1 grid in $120{\sim}140\;kVp$.

  • PDF

Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws (고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구)

  • Kim Jeung-kee;Choi Young-Min;Lee Hyung-Sik;Hur Won-Joo
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.237-244
    • /
    • 1996
  • Purpose : The accurate dosimetry of independent collimator equipped for 6MV and 15MV X-ray beam was investigated to search for the optimal correction factor. Materials and Methods : The field size factors, beam quality and dose distribution were measured by using 6MV, 15MV X-ray Field size factors were measured from $3{\times}3cm^2$ to $35{\times}35cm^2$ by using 0.6cc ion chamber (NE 2571) at Dmax. Beam qualities were measured at different field sizes, off-axis distances and depths. Isodose distributions at different off-axis distance using $10\times10cm^2$ field were also investigated and compared with symmetric field. Result: 1) Relative field size factors was different along lateral distance with maximum changes in $3.1\%$ for 6MV and $5\%$ for 15MV. But the field size factors of asymmetric fields were identical to the modified central-axis values in symmetric field, which corrected by off-axis ratio at Dmax. 2) The HVL and PDD was decreased by increasing off-axis distance. PDD was also decreased by increasing depth For field size more than $5{\times}cm^2$ and depth less than 15cm, PDD of asymmetric field differs from that of symmetric one ($0.5\~2\%$ for 6MV and $0.4\~1.4\%$ for 15MV). 3) The measured isodose curves demonstrate divergence effects and reduced doses adjacent to the edge close to the flattening filter center was also observed. Conclusion . When asymmetric collimator is used, calculation of MU must be corrected with off-axis and PDD with a caution of underdose in central axis.

  • PDF

Current status and trend of the publication to the SCI and SCIE journals in the field of radiation oncology in Korea for 30 years

  • Park, Won;Huh, Seung-Jae
    • Radiation Oncology Journal
    • /
    • v.30 no.1
    • /
    • pp.14-19
    • /
    • 2012
  • Purpose: We collected the data of Science Citation Index (SCI) and SCI Expended (SCIE) papers written by the members of the Korean Society of Radiation Oncology (KOSRO) to analyze the current status and the future trend. Materials and Methods: We searched the database of SCIE for the period from 1981 to 2011 at the Web of Knowledge site. Articles, reviews or proceedings written by KOSRO members as the first or corresponding authors were included. Search terms were the following combination of subject headings: therapeut radiol, radiat oncol, Korea. For National Cancer Center, combined search terms such as natl canc ctr, Korea and the names of faculties were applied. Results: The total number of SCIE papers was 547. Numbers of the published papers in 1995, 2000, 2005, and 2010, were increased continuously, which was 2, 14, 40, and 83, respectively. The average impact factor was 2.9. The papers were published at the 134 different journals. The proportion of "International Journal of Radiation Oncology Biology Physics" was 23.4% of all the papers. The number and proportions of papers by subject categories were 87 (15.9%) in biology, 73 (13.3%) in physics and 387 (70.6%) in clinics. The papers of the top five institutions, based on the number of published papers, occupied 66.3%. Conclusion: The number of SCIE papers is increasing rapidly in the field of radiation oncology in Korea. To improve the quality of papers, multi-institutional retrospective or prospective randomized studies should be done for the common cancers in Korea.

Novel and Effective Almagate Enema for Hemorrhagic Chronic Radiation Proctitis and Risk Factors for Fistula Development

  • Yuan, Zi-Xu;Ma, Teng-Hui;Zhong, Qing-Hua;Wang, Huai-Ming;Yu, Xi-Hu;Qin, Qi-Yuan;Chu, Li-Li;Wang, Lei;Wang, Jian-Ping
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.2
    • /
    • pp.631-638
    • /
    • 2016
  • Radiation proctitis is a common complication after radiotherapy for pelvic malignant tumors. This study was conducted to assess the efficacy of novel almagate enemas in hemorrhagic chronic radiation proctitis (CRP) and evaluate risk factors related to rectal deep ulcer or fistula secondary to CRP. All patients underwent a colonoscopy to confirm the diagnosis of CRP and symptoms were graded. Typical endoscopic and pathological images, risk factors, and quality of life were also recorded. A total of 59 patients were enrolled. Gynecological cancers composed 93.1% of the primary malignancies. Complete or obvious reduction of bleeding was observed in 90% (53/59) patients after almagate enema. The mean score of bleeding improved from 2.17 to 0.83 (P<0.001) after the enemas. The mean response time was 12 days. No adverse effects were found. Moreover, long-term successful rate in controlling bleeding was 69% and the quality of life was dramatically improved (P=0.001). The efficacy was equivalent to rectal sucralfate, but the almagate with its antacid properties acted more rapidly than sucralfate. Furthermore, we firstly found that moderate to severe anemia was the risk factor of CRP patients who developed rectal deep ulcer or fistulas (P= 0.015). We also found abnormal hyaline-like thick wall vessels, which revealed endarteritis obliterans and the fibrosis underlying this disease. These findings indicate that almagate enema is a novel effective, rapid and well-tolerated method for hemorrhagic CRP. Moderate to severe anemia is a risk factor for deep ulceration or fistula.

Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator (의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가)

  • Lee, Dong-Woon;Jung, Kang-Kyo;Shin, Gwi-Soon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.177-184
    • /
    • 2016
  • Recently linear accelerator of radiation therapy intensity modulated radiation therapy, stereotactic radiation therapy are widely used. Such radiation treatment techniques are generally difficult to exclude the small field by using the inverse treatment plan. It is necessary to dose an accurate measurement of characteristics of the small field. Thus, using different detectors to measure the volume of the effective percentage depth dose, beam profile, and the output factor of the small field was to evaluate the dose characteristics of each detector. Experimental results for the X-ray beam 6 MV energy beam quality($PDD_{20}/PDD_{10}$) is $10{\times}10cm^2$ Diode detector is as high as 2.4% compared to Pinpoint detector. All field size to lesser effective volume of Diode detector shows that it is far better than other detectors by more than 50% of small penumbra, therefore spatial resolution far excellent. In field size $2{\times}2cm^2$ Semiflex detector was measured about 2% less than the other detector. Field size $1{\times}1cm^2$ is that there is no judgment about the validity show the difference between 20%. Field size $1{\times}1cm^2$ from the measured values of the Diode detector and Pinpoint detector showed a 13% difference. Less than field size $3{\times}3cm^2$ the feed to the difference between the output factor of the effective volume of the detector to be used for the effective volume available to the detector.

Spinal Cord Partial Block Technique Using Dynamic MLC

  • Cho, Sam-Ju;Yi, Byong-Yong;Back, Geum-Mun;Lee, Sang wook;Ahn, Seung-Do;Kim, Jong-Hoon;Kwon, Soo-Il;Park, Eun-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.138-140
    • /
    • 2002
  • The spinal cord dose is the one of the limiting factor for the radiation treatment of the head & neck (H&N) or the thorax region. Due to the fact that the cord is the elongated shaped structure, it is not an easy task to maintain the cord dose within the clinically acceptable dose range. To overcome this problem, the spinal cord partial block technique (PBT) with the dynamic Multi-Leaf Collimator (dMLC) has been developed. Three dimension (3D) conformal beam directions, which minimize the coverage of the normal organs such as the lung and the parotid gland, were chosen. The PBT field shape for each field was designed to shield the spinal cord with the dMLC. The transmission factors were determined by the forward calculation method. The plan comparisons between the conventional 3D conformal therapy plan and the PTB plan were performed to evaluate the validity of this technique. The conformity index (CI) and the dose volume histogram (DVH) were used as the plan comparison indices. A series of quality assurance (QA) was performed to guarantee the reliable treatment. The QA consisted of the film dosimetry for the verification of the dose distribution and the point measurements. The PBT plan always generated better results than the conventional 3D conformal plan. The PBT was proved to be useful for the H&N and thorax region.

  • PDF

Investigation of Electrically Small Folded Slot Spherical Helix Magnetic Dipole Antenna (전기적 소형 Folded Slot Spherical Helix 자기 다이폴 안테나에 관한 연구)

  • Shin, Geonyeong;Kong, Myeongjun;Lee, Su-Hyeon;Yoon, Ick-Jae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.4
    • /
    • pp.261-268
    • /
    • 2017
  • In this paper, we propose an FSSH(Folded Slot Spherical Helix) magnetic dipole antenna with a form factor easy to build and study its radiation properties. The number of folded arms, the gap between them and the metal thickness are tuned to achieve relatively simple structure to realize whereas maintaining high radiation efficiency at an electrically small size. The proposed design shows wide radiation efficiency bandwidth and it is confirmed by circuit simulation that the non-Foster impedance matching techniques could be utilized for its practical use. The prototype of the proposed antenna is built with the aid of an SLS(Selective Laser Sintering) 3D printing technology. The measured result shows lower Q impedance characteristic due to high resistive loss of the copper tape joints.

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF