• 제목/요약/키워드: Radiation Pipe

검색결과 76건 처리시간 0.032초

유도초음파를 이용한 3/4″ 배관 결함 검출 연구 (A Study for Flaw Detection of 3/4″ Pipe by Using Guided Wave)

  • 정우근;김진회;천근영
    • 한국압력기기공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.40-45
    • /
    • 2019
  • Unlike the welded pipes in the primary system of light water nuclear power plants being periodically inspected with in-Service inspection program, relatively small pipes with the outer diameter less than 2 inch have not been regularly inspected to date. However, after several failure reports on the occurrence of critical crack-like defects in small pipes, inspection for the small pipes has been more demanded because it could cause the provisional outage of nuclear power plants. Nevertheless, there's no particular method to examine the small pipes having access limitations for inspection due to various reasons; inaccessible area, excessive radiation exposure, hazardous surrounding, and etc. This study is to develop a reliable inspection technique using torsional and flexural modes of guided wave to detect defects that could occur in inaccessible area. The attribute of guided wave that can travel a long distance enables to inspect even isolated range of the pipe from accessible location. This paper presents a case study of the evaluation test on 3/4" small-bore pipes with guide wave method. The test result demonstrates the crack signal behavior and assures possibility to detect the crack signal in a flexural mode, which is clearly distinguishable from the symmetric structure signal in a torsional mode.

깊이 인자를 고려한 매설배관의 사고피해영향 비교 분석에 관한 연구 (A Study for Comparison of Consequence Analysis for Buried Pipeline Considering the Depth Factor)

  • 한승훈;설지우;류병태;태찬호;고재욱
    • 한국가스학회지
    • /
    • 제20권5호
    • /
    • pp.9-16
    • /
    • 2016
  • 매설배관은 내부 또는 외부의 결함으로 인하여 leak나 rupture가 발생 할 수 있으며, 가스가 누출 시 큰 사고가 발생할 수 있기 때문에 정량적 위험성평가를 통한 분석이 필요하다. 하지만 현재 매설배관에 대한 위험성 평가시 매설을 고려하지 않거나, 매설 깊이를 고려하지 않고 무조건 배관압력의 1/10으로 가정하는 OGP기준을 사용하고 있는 실정이다. 이에 본 연구에서는 여러 기관의 매설배관 ETA분석자료를 통하여 발생가능 사고 중 Jet fire의 사고피해영향을 분석하였으며, Jet fire의 복사열 계산에 있어서 배관의 매설깊이 인자를 고려한 매설모델을 수립하였다. 사례연구는 New Jersey의 Edison지역에서 발생한 사고를 이용하여 본 모델과 OGP모델을 비교 분석하였다. 연구결과 화염원으로부터 10m거리를 기준으로 매설모델의 복사열 값이 OGP모델에 비해 실제 사례와 비슷한 값을 얻을 수 있었다.

산소 에틸렌 토치로 동파이프 절단작업 후 발생한 이산화질소 중독에 의한 비심인성 폐부종 1례 (A Case of Non-cardiogenic Pulmonary Edema caused by Nitrogen Dioxide Poisoning after Cutting Copper Pipe with an Oxyethylene Torch)

  • 제갈양진;안종준;서광원;차희정;권운정;김양호
    • 대한임상독성학회지
    • /
    • 제4권2호
    • /
    • pp.175-179
    • /
    • 2006
  • Welders are exposed to a number of hazards including metal fumes, toxic gases, electricity, heat, noise, and radiation such as ultraviolet and infrared light. We encountered a patient who developed non-cardiogenic pulmonary edema within a day after cutting copper pipe with an oxyethylene torch. The patient was a 26-year-old welder. He complained of dyspnea, generalized myalgia, and febrile sensation the following morning. The patient's chest X-ray and chest CT scan showed extensively distributed and ill-defined centrilobular nodules. Both his symptoms and chest X-ray abnormalities improved spontaneously. We attributed the patient's symptoms to non-cardiogenic pulmonary edema due to nitrogen dioxide, reasoning that: 1) the pipe consisted only of copper, according to material safety data sheet (MSDS); 2) a previous report in the literature demonstrated increased nitrogen dioxide levels under similar conditions; 3) the patient's clinical course and radiologic findings were very reminiscent of non-cardiogenic pulmonary edema following accidental exposure to nitrogen dioxide.

  • PDF

LNG 재기화 공정에서 LNG 누출에 따른 화재 및 폭발사고의 피해영향 분석 (Analysis of the Impact of Fire and Explosion Accidents due to LNG Leaks in the LNG Re-gasification Process)

  • 이윤호
    • 해양환경안전학회지
    • /
    • 제24권6호
    • /
    • pp.825-833
    • /
    • 2018
  • 본 연구에서는 LNG 공급계통시스템의 재기화 공정에서 배관 손상으로 인한 누출사고 발생시 LNG 성분 및 누출공의 크기에 따른 연소특성에 대한 피해범위를 산출하고, 피해영향을 해석하였다. LNG 성분에 따른 연소특성을 확인하기 위하여 7곳의 LNG 산지별 위험도를 확인한 결과 산지별 큰 차이를 보이지 않았으나, LNG 구성성분 중 메탄의 함유량이 많을수록 플래시화재 발생범위 및 증기운 폭발에 의한 과압이 발생하는 위험범위 그리고 제트화재 발생에 의한 열 복사량 피해영향이 다른 산지에 비해 비교적 낮음을 알 수 있었다. 또한 배관 누출공의 크기에 따라 누설, 파공, 파괴 3단계에 나누어 위험 범위 및 폭발에 미치는 영향에 대한 연구를 수행하였으며, 플래시화재로 인한 피해영향범위를 계산하고, 이에 따라 LNG 누출시 화재가능 위험범위를 확인했으며, 과압의 영향 및 복사열로 부터의 피해범위를 예측할 수 있었다. 이를 통해 LNG 조성 및 배관 누출공의 크기가 화재 및 폭발에 미치는 영향을 예측할 수 있었다.

Thermal field of large-diameter concrete filled steel tubular members under solar radiation

  • Yang, Daigeng;Chen, Guorong;Ding, Xiaofei;Xu, Juncai
    • Computers and Concrete
    • /
    • 제26권4호
    • /
    • pp.343-350
    • /
    • 2020
  • Concrete-filled steel tubular (CFST) members have been widely used in engineering, and their tube diameters have become larger and larger. But there is no research on the thermal field of large-diameter CFST structure. These studies focused on the thermal field of the large-diameter CFST structure under solar radiation. The environmental factors and the actual placement position were considered, and the finite element model (FEM) of the thermal field of CFST members under solar radiation (SR) was established. Then the FEM was verified by practical experiments. The most unfavorable temperature gradient model in the cross-section was proposed. The testing results showed that the temperature field of the large-diameter CFST member section was non-linearly distributed due to the influence of SR. The temperature field results of CFST members with different pipe diameters indicated that the larger the core concrete diameter was, the slower the central temperature changed, and there was a significant temperature difference between the center and the boundary. Based on the numerical model, the most unfavorable temperature gradient model in the section was proposed. The model showed that the temperature difference around the center of the circle is small, and the boundary temperature difference is significant. The maximum temperature difference is 15.22℃, which appeared in the southern boundary area of the specimen. Therefore, it is necessary to consider the influence of SR on the thermal field of the member for large-diameter CFST members in actual engineering, which causes a large temperature gradient in the member.

동도금 EP방열판에 의한 소형LED조명등 방열 (Heat Radiation of LED Light using eu Plating Engineering Plastic Heat Sink)

  • 조영태
    • 한국생산제조학회지
    • /
    • 제20권1호
    • /
    • pp.81-85
    • /
    • 2011
  • Recently, the electronic parts are to be thinner plate, smaller size, light weight material and CPU, HDD and DRAM in all the parts have been produced on the basis of the high speed and greater capacity. Also, conventional goods have replaced a LED (Light-Emitting Diode) in lighting products so; such industry devices need to have cooling. To maximize all the performance on the heat-radiated products, the area of heat-radiated parts is required to be cooled for keeping the life time extension and performance of product up. Existing cooling systems are using radiant heat plate of aluminum, brass by extrusion molding, heat pipe or hydro-cooling system for cooling. There is a limitation for bringing the light weight of product, cost reduction, molding of the cooling system. So it is proposed that an alternative way was made for bringing to the cooling system. EP (Engineering Plastic) of low-cost ABS (Acrylonitrile butadiene styrene Resin) and PC (Polycarbonate) was coated with brass and the coating made the radiated heat go up. The performance of radiant heat plate is the similar to the existing part. We have studied experimentally on the radiated heat plate for the light-weight, molding improvement and low-cost. From now on, we are going to develop the way to replace the exiting plate with exterior surface of product as a cooling system.

In-Service Identification of the Heterogeneous Zone in Petrochemical Pipelines by Using Sealed Gamma-Ray Sources $(^{60}Co,\;^{137}Cs)$

  • Kim, Jin-Seop;Jung, Sung-Hee;Kim, Jong-Bum
    • 비파괴검사학회지
    • /
    • 제26권3호
    • /
    • pp.169-173
    • /
    • 2006
  • In-service diagnoses of pipeline facilities are important for a systematic maintenance of them. Field applications by using sealed gamma-ray sources $(^{60}Co,\;^{137}Cs)$ were performed to identify the heterogeneous zone in the pipelines of a distillation tower and a flare stack respectively. From the results, the heterogeneous zones in the pipelines were successfully identified. In the case of the pipeline connected to the distillation tower, a vapor pocket was detected in the fluid under hydrodynamic conditions, which could explain the reason for a decrease of the flow rate. In another case, an area with some amount of catalyst deposits was found at the bottom of the gas pipeline which was connected to the flare stack. And these findings provided important information for the process operators. Diagnosis technique by using gamma radiation sources has been proven to be an effective and reliable method for providing information on a media distribution in a facility.

수치해석을 통한 KSTAR 주장치 열차폐 패널 열.유동 특성해석 (Thermal Flow Analysis and Design of KSTAR Thermal Shield Panel by Numerical Method)

  • 김동락;김광선;노영미;조승연;김승현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.73-77
    • /
    • 2002
  • In order to derive the detailed design of Thermal Shield Cryopanel. which plays a role to make the Tokamak Nuclear Fusion Equipment work at both static and efficient conditions the commercially available software package FLUENT Version 5.3, was utilized. This study investigated the effects of thermal sources and distributions on the temperatures of Lid. Body. Base. and EH-Port Cryopanel by the numerical technique whose grid generations cover the solid and 9as region of the panel. The physical model of the Thermal Shield Cryopanel is that the 10mm diameter of the pipe with 1mm thickness is soldered on the Stainless steel Panel with 4mm thickness. The heat fluxes to the panel are assumed to be by thermal radiation in the vacuum space and by conduction through the supporters. The inlet conditions of Helium gas are 20 atmospheric Pressures and 60K temperature. The panel shapes with cooling Pipes and the operational conditions to keep appropriate temperature distribution of Thermal Shield Cryopanel Have been found and suggested.

방사선안전관리 실무: (II) 배기중 및 배수중 배출관리기준의 적용 (Practical Radiation Safety Control: (II) Application of Numerical Guidance for the Discharges of Radioactive Gaseous and Liquid Effluents)

  • 김현기
    • Journal of Radiation Protection and Research
    • /
    • 제39권1호
    • /
    • pp.61-64
    • /
    • 2014
  • 방사성동위원소를 포함하는 방사성물질은 전력생산에서부터 연구, 산업, 진단 및 치료 등의 목적으로 다양하게 활용되고 있다. 비밀봉 방사성물질을 이용하는 시설에서 이들 시설로부터 기체, 입자 또는 액체 형태의 방사성물질이 다소간 환경으로 배출되는 것은 피할 수 없으며, 이는 일반인의 방사선피폭을 야기하는 주요한 인공 방사선원이다. 본 논문은 보수적 가정과 간단한 계산에 의거하여 액상의 비밀봉선원을 사용하는 시설에서 배기설비를 통해 배출되는 공기중 방사성물질의 최대농도와 방사성폐액을 저장하는 저류조 배수구에서 배출되는 폐액중 방사성물질의 평균농도를 산출한 후, 관련 고시에서 정하는 각각의 배출관리기준값과 비교함으로써 일반인의 피폭 정도를 평가하는 절차를 제공한다. 이를 위해 방사성핵종의 1일 사용량, 취급형태, 비산율, 방사성폐액 발생량, 배기설비, 배수설비 등을 적절히 가정하였다. 제시된 절차는 비밀봉 방사성물질을 취급하는 시설에서 환경으로의 방사성물질의 계획적 배출에 따른 주변환경 영향평가에 손쉽게 적용할 수 있으므로 일반인의 피폭량 감축에 필요한 시설에서의 방사선안전관리 실무요건 도출에 활용할 수 있다.

Study on the Development of LED Headlamps for Used Cars

  • Jung, Eui-Dae;Lee, Young-Lim
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권5호
    • /
    • pp.270-274
    • /
    • 2014
  • Currently, LED headlamps are only attached to newly manufactured vehicles, and it remains difficult to mount LED headlamps on used cars. Therefore LED headlamps need to be developed for used cars as a replacement of their halogen lamps. Due to a number of spatial limitations, it is critical to ensure a certain level of thermal performance. In order to obtain a design for efficient heat radiation, this paper aimed to optimize thermal management through a combination of heat sinks, heat pipes and fans. Based on such a design, this paper succeeded in developing LED headlamps of the desired performance to replace the halogen bulbs of used cars.