• Title/Summary/Keyword: Radiation Emergency

Search Result 224, Processing Time 0.024 seconds

Current status of disposal and measurement analysis of radioactive components in linear accelerators in Korea

  • Kwon, Na Hye;Shin, Dong Oh;Kim, Jinsung;Yoo, Jaeryong;Park, Min Seok;Kim, Kum Bae;Kim, Dong Wook;Choi, Sang Hyoun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.507-513
    • /
    • 2022
  • When X-ray energy above 8 MV is used, photoneutrons are generated by the photonuclear reaction, which activates the components of linear accelerator (linac). Safely managing the radioactive material, when disposing linac or replacing components, is difficult, as the standards for the radioactive material management are not clear in Korea. We surveyed the management status of radioactive components occurred from medical linacs in Korea. And we also measured the activation of each part of the discarded Elekta linac using a survey meter and portable High Purity Germanium (HPGe) detector. We found that most medical institutions did not perform radiation measurements when disposing of radioactive components. The radioactive material was either stored within the institution or collected by the manufacturer. The surface dose rate measurements showed that the parts with high surface dose rates were target, primary collimator, and multileaf collimator (MLC). 60Co nuclide was detected in most parts, whereas for the target, 60Co and 184Re nuclides were detected. Results suggest that most institutions in Korea did not have the regulations for disposing radioactive waste from linac or the management procedures and standards were unclear. Further studies are underway to evaluate short-lived radionuclides and to lay the foundation for radioactive waste management from medical linacs.

A Study on Exposure to radiation of the patient who visited an emergency room at a University Hospital (한 대학병원 응급실에 방문한 환자의 방사선 피폭에 관한 연구)

  • Ahn, Buyung-Ju;Lee, Sang-Bock;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.23-34
    • /
    • 2007
  • To find how much radiation was exposed the patients who visit emergency room, a measurement study was made for radiation amount toward 200 patients selected randomly among visitors to an emergency room in a university hospital from March 16 to 31st, 2006. The results are as follows ; 1. Among the subjects 50 person(25.0%) were transferred from other hospitals, 24 persons(8.3) come after traffic accident, 50 persons for other accident and 76 persons for general medical care. 2. The average frequency of X-ray taking was calculated as 6.4 time per person among transferred patients, 14.5 times per person among patients with traffic accident and 2.6 times per person among general medical care. 3. The radiation exposure amount by kind of X-ray showed 28.9mGyfor general X-ray diagnosis, 84.2mGy for CT scanning and 1.02mGy for other special radiation study. 4. Average radiation exposure amount was calculated as 24.6mGy by transferred patients, 55.2mGy by patients with traffic accident, 17.1mGy by patients with other accidents and 17.0mGy by general patients. 5. Through the comparison of radiation exposure amount among to subject with maximum allowance threshold by International Commission on X-ray Radium Protection, transferred patients exceeded 6 times than allowance in whole body except extremities and joints, blood forming organ, reproductive system, vitreous body of eye, bone, thyroid gland, skin and etc, Patient suffered from traffic accidents were exposed 10 times more than allowance. In conclusion, the radiation exposure amount during X-rat diagnosis re too much and exceeded allowance standard by International Commission on X-ray Radium Protection. So further study and preventive measure to decrease radiation exposure by patients who visit emergency room.

  • PDF

Tissue distribution, excretion and effects on genotoxicity of tritium following oral administration to rats

  • Lee, Jei Ha;Kim, Cha Soon;Choi, Soo Im;Kim, Rae-Kwon;Kim, Ji Young;Nam, Seon Young;Jin, Young Woo;Kim, In Gyu
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.303-309
    • /
    • 2019
  • Tritium is an important nuclide that must be monitored for radiation safety management. In this study, HTO was orally administered to rats at the level of 37 kBq ($1{\mu}Ci$) or 370 kBq ($10{\mu}Ci$) to examine tissue distribution and excretion levels. After sacrifice, wet and dry tissue samples were weighed and analyzed for tissue free-water tritium (TFWT) and organically bound tritium (OBT). The mean tissue concentrations of TFWT (OBT) were 30.9 (17.8) and 4.4 (8.1) Bq/g on days 7 and 13 at the 37 kBq level and 30.8 (64.6) Bq/g on day 17 at the 370 kBq level. To assess the cytogenetic damage due to tritium exposure, a cytokinesis-blocked micronucleus (MN) assay was performed in blood samples from rats exposed to HTO for 14 and 21 days after oral administration. There was no significant difference in the MN frequencies between the control and exposed rats.

Application for Limitation of Food Stuffs in a Radiological Emergency (방사선비상시 식품섭취제한 기준 및 적용성)

  • Lee, Jong-Tai;Lee, Goan-Yup;Khang, Byung-Oui;Oh, Ki-Hoon;Kim, Chang-Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.2
    • /
    • pp.89-94
    • /
    • 2002
  • Intervention levels for foodstuff restriction in a radiological emergency in Korea are suggested based on the justification and the optimization through the cost-benefit approach method from IAEA Safty Series 109 recommendation. Intervention levels are specified for three broad groups of radionuclides with similar values of committed effective dose per unit intake and specified for two broad categories of foodstuff grouped according to value per kg. It is also discussed on the applicability of revised intervention levels for foodstuff restriction.

The Effects of Cynanchi wilfordii Radix Ethanol Extracts upon Irradiated Rat's Blood and Organ (백하수오 에탄올추출물이 방사선조사에 따른 흰쥐의 혈구 및 장기에 미치는 영향)

  • Kim, Jang-Oh;Choi, Jun-Hyeok;Shin, Ji-Hye;Jung, Do-Young;Min, Byung-In
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.451-459
    • /
    • 2016
  • The development of radioprotector is being actively conducted in order to reduce the damage from over radiation exposure at radiation accident or radiation therapy. So this study was confirmed for radiation protective effects using the Cynanchi wilfordii Radix that has been known to be effective for antioxidant activity, anti-cancer, immune enhancing effects. The method of this study was administered orally Cynanchi wilfordii Radix ethanol extracts to Sprague Dawley Rat(SD Rat) for 14 days once a day, while measuring changed blood cell, spleen index, liver and uterus tissue along the change in time of 1, 4, 7 and 21 days after X-ray beam of 7 Gy irradiation. As the result of the experiment, the experimental group's rats which are administered with Cynanchi Wilfordii Radix ethanol extracts showed a rapid recovery in white blood cell count(p < 0.05) and spleen index(p < 0.05). In addition, condensation of nuclei, cytoplasmic swelling, and inflammatory cell infiltration in experimental group's liver cell was decreased more than in irradiation group's component. Further, experimental group's Uterine gland decreased the apoptosis more than irradiation group's components did. It is expected that Cynanchi Wilfordii Radix extracts will be useful as a new radioprotector. With above in mind, this paper may provide appropriate implications with the field of emergency management such as radiation accident.

A Rapid Dose Assessment and Display System Applicable to PWR Accident (선량평가 및 Display시스템)

  • Moon, Kwang-Nam;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.67-77
    • /
    • 1988
  • The necessity of developing a rapid dose assessment system has been emphasized for an effective emergency response of mitigation of off-site radiological consequences. A microcomputer program based on a rapid dose assessment model of the off-site radiological consequences is developed for various accdident sinarios for the Nuclear Power Plants in Korea. This model, which is consists of the user answering-question input format as a menu driven method and the output format of table and graphic types, is helpful to decision-making on Emergency Preparedness by being more rapidly able to implement the off-site dose assessment and to interpret the result.

  • PDF

Thermally assisted IRSL and VSL measurements of display glass from mobile phones for retrospective dosimetry

  • Discher, Michael;Kim, Hyoungtaek;Lee, Jungil
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.429-436
    • /
    • 2022
  • Investigations of retrospective dosimetry have shown that components of mobile phones are suitable as emergency dosimeters in case of radiological incidents. For physical dosimetry, components can be read out using optically stimulated luminescence (OSL), thermoluminescence (TL) and phototransferred thermoluminescence (PTTL) methods to determine the absorbed dose. This paper deals with a feasibility study of display glass from modern mobile phones that are measured by thermally assisted (Ta) optically stimulated luminescence. Violet (VSL, 405 nm) and infrared (IRSL, 850 nm) LEDs were used for optical stimulation and two protocols (Ta-VSL and Ta-IRSL) were tested. The aim was to systematically investigate the luminescence properties, compare the results to blue stimulated Ta-BSL protocol (458 nm) and to develop a robust measurement protocol for the usage as an emergency dosimeter after an incident with ionizing radiation. First, the native signals were measured to calculate the zero dose signal. Next, the reproducibility and dose response of the luminescence signals were analyzed. Finally, the signal stability was tested after the storage of irradiated samples at room temperature. In general, the developed Ta-IRSL and Ta-VSL protocols indicate usability, however, further research is needed to test the potential of a new protocol for physical retrospective dosimetry.

Necessity for a Whole-body CT Scan in Alert Blunt Multiple Trauma Patients. (의식이 명료한 다발성 외상환자에게 전신 전산화단층촬영이 반드시 필요한가?)

  • Mun, You-Ho;Kim, Yun-Jeong;Shin, Soo-Jeong;Park, Dong-Chan;Park, Sin-Ryul;Ryu, Hyun-Wook;Seo, Kang-Suk;Park, Jung-Bae;Chung, Jae-Myung;Bae, Ji-Hye
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.89-95
    • /
    • 2010
  • Purpose: Whole-body CT is a very attractive diagnostic tool to clinicians, especially, in trauma. It is generally accepted that trauma patients who are not alert require whole-body CT. However, in alert trauma patients, the usefulness is questionable. Methods: This study was a retrospective review of the medical records of 146 patients with blunt multiple trauma who underwent whole body CT scanning for a trauma workup from March 1, 2008 to February 28, 2009. We classified the patients into two groups by patients' mental status (alert group: 110 patients, not-alert group: 36 patients). In the alert group, we compared the patients' evidence of injury (present illness, physical examination, neurological examination) with the CT findings. Results: One hundred forty six(146) patients underwent whole-body CT. The mean age was $44.6{\pm}18.9$ years. One hundred four (104, 71.2%) were men, and the injury severity score was $14.0{\pm}10.38$. In the not-alert group, the ratios of abnormal CT findings were relatively high: head 23/36(63.9%), neck 3/6(50.0%), chest 16/36(44.4%) and abdomen 9/36(25%). In the alert group, patients with no evidence of injury were rare (head 1, chest 6 and abdomen 2). Nine(9) patients did not need any intervention or surgery. Conclusion: Whole-body CT has various disadvantages, such as radiation, contrast induced nephropathy and high medical costs. In multiple trauma patients, if they are alert and have no evidence of injury, they rarely have abnormal CT findings, and mostly do not need invasive treatment. Therefore, we should be cautious in performing whole-body CT in alert multiple trauma patients.