MOSFET 검출기의 방사선 측정 기법 (A Methodology of Radiation Measurement of MOSFET Dosimeter)

  • 노영찬;이상용;강필현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.159-162
    • /
    • 2009
  • The necessity of radiation dosimeter with precise measurement of radiation dose is increased and required in the field of spacecraft, radiotheraphy hospital, atomic plant facility, etc. where radiation exists. Until now, a low power commercial metal-oxide semiconductor(MOS) transistor has been tested as a gamma radiation dosimeter. The measurement error between the actual value and the measurement one can occur since the MOSFET(MOS field-effect transistor) dosimeter, which is now being used, has two gates with same width. The measurement value of dosimeter depends on the variation of threshold voltage, which can be affected by the environment such as temperature. In this paper, a radiation dosimeter having a pair of MOSFET is designed in the same silicon substrate, in which each of the MOSFETs is operable in a bias mode and a test mode. It can measure the radiation dose by the difference between the threshold voltages regardless of the variation of temperature.

  • PDF

Preliminary Results of Tissue-Equivalent Proportional Counter (TEPC) Dosimeter for Measuring In-Situ Aviation Radiation

  • Nam, Uk-won;Park, Won-kee;Hwang, Junga;Sohn, Jongdae;Moon, Bongkon;Kim, Sunghwan
    • Journal of Astronomy and Space Sciences
    • /
    • 제37권4호
    • /
    • pp.249-255
    • /
    • 2020
  • We develop the tissue-equivalent proportional counter (TEPC) type's space radiation dosimeter to measure in-situ aviation radiation. That was originally developed as a payload of small satellite in the low-earth orbit. This dosimeter is based on a TEPC. It is made of an A-150 tissue-equivalent plastic shell of an internal diameter of 6 cm and a thickness of 0.3 cm. TEPC is filled with pure propane at 13.9 torrs to simulate a cell diameter of 2 ㎛. And the associated portable and low power electronics are also implemented. The verification experiments have been performed by the calibration experiments at ground level and compared with Liulin observation at aircraft altitude during the flight between Incheon airport (ICN) and John F. Kennedy airport (JFK). We found that the TEPC dosimeter can be used as a monitor for space radiation dosimeter at aviation altitude based on the verification with Liulin observation.

방사선피폭관리시스템를 위한 D-Shuttle 선량계의 방사선 선량측정 (Radiation Dose Measurement of D-Shuttle Dosimeter for Radiation Exposure Management System)

  • 권대철
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.321-328
    • /
    • 2017
  • D-Shuttle (Chiyoda Technol Corporation, Tokyo, Japan) 선량계를 이용하여 개인피폭관리 및 자연방사선량의 모니터링을 위한 기초자료를 제공하는데 연구의 목적이 있다. D-Shuttle을 이용하여 선량을 산출하였다. 선량보고서에서 400 일 노출되었을 때에 1.346 mSv 이었고, 연간선량 (annual dose per year)은 1.228 mSv/year, 평균시간선량 (average dose per hour)은 $0.014{\mu}Sv/hr$ 이었다. 국내의 개인 외부피폭선량 (1.295 mSv/year =Korea average natural individual external dose), 국내의 연간부가선량 (additional dose per year)은 -0.0663 mSv/year 이다. D-Shuttle은 방사선모니터링을 위한 개인선량계로 방사선의 검출성능 우수한 기능, 실시간 방사선 피폭관리, 방사선 작업의 경보 기능, 효율적이고 사용이 편리한 개인 방사선선량의 피폭관리로 ALARA에 매우 유용한 선량계로 사용할 수 있다. 방사선작업종사자와 지역주민의 방사선모니터링 측정기기로 병원, 산업, 의료현장, 원전사고 지역과 비파괴 분야의 위험한 지역에서 방사선모니터링으로 활용될 수 있다.

실리콘 핀 포토다이오드를 이용한 능동형 방사선 피폭 전자선량계의 구현 (Implementation of Electronic Personal Dosimeter Using Silicon PIN Photodiode)

  • 이운근;백광렬;권석근
    • 제어로봇시스템학회논문지
    • /
    • 제9권4호
    • /
    • pp.296-303
    • /
    • 2003
  • A personal portable type electronic dosimeter using silicon PIN photodiode and small GM tube is recently attracting much attention due to its advantages such as an immediate indication function of dose and dose rate, alerting function, and efficient management of radiation exposure history and dose data. We designed and manufactured a semiconductor radiation detector aimed to directly measure X-ray and v-ray irradiated in silicon PIN photodiode, without using high-priced scintillation materials. Using this semiconductor radiation detector, we developed an active electronic dosimeter, which measures the exposure dose using pulse counting method. In this case, it has a shortcoming of over-evaluating the dose that shows the difference between the dose measured with electronic dosimeter and the dose exposed to the human body in a low energy area. We proposed an energy compensation filter and developed a dose conversion algorithm to make both doses indicated on the detector and exposed to the human body proportional to each other, thus enabling a high-precision dose measurement. In order to prove its reliability in conducting personal dose measurement, crucial for protecting against radiation, the implemented electronic dosimeter was evaluated to successfully meet the IEC's criteria, as the KAERI (Korea Atomic Energy Research Institute) conducted test on dose indication accuracy, and linearity, energy and angular dependences.

A Methodology of Dual Gate MOSFET Dosimeter with Compensated Temperature Sensitivity

  • Lho, Young-Hwan
    • 전기전자학회논문지
    • /
    • 제15권2호
    • /
    • pp.143-148
    • /
    • 2011
  • MOS (Metal-Oxide Semconductor) devices among the most sensistive of all semiconductors to radiation, in particular ionizing radiation, showing much change even after a relatively low dose. The necessity of a radiation dosimeter robust enough for the working environment has increased in the fields of aerospace, radio-therapy, atomic power plant facilities, and other places where radiation exists. The power MOSFET (Metal-Oxide Semiconductor Field-Effect Transistor) has been tested for use as a gamma radiation dosimeter by measuring the variation of threshold voltage based on the quantity of dose, and a maximum total dose of 30 krad exposed to a $^{60}Co$ ${\gamma}$-radiation source, which is sensitive to environment parameters such as temperature. The gate oxide structures give the main influence on the changes in the electrical characteristics affected by irradiation. The variation of threshold voltage on the operating temperature has caused errors, and needs calibration. These effects can be overcome by adjusting gate oxide thickness and implanting impurity at the surface of well region in MOSFET.

KAEROT/m2용 방사선 수명 측정모듈 개발 (The development of radiation lifetime measuring module for KAEROT/m2)

  • 이남호;김승호;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.793-796
    • /
    • 2003
  • The electronics of a mobile robot ill nuclear facilities is required to satisfied the reliability to sustain survival in its radiation environment. To know how much radiation the robot has been encountered to replace sensitive electronic parts, a dosimeter to measure total accumulated dose is necessary. Among many radiation dosimeters or detectors, semiconductor radiation sensors have advantages in terms of power requirements and their sires over conventional detectors. This paper describes the use of the radiation-induced threshold voltage change of a commercial power pMOSFET as an accumulated radiation dose monitoring mean and that of the photo-current of a commercial PIN Diode as a dose-rate measurement mean. Commercial p-type power MOSFETs and PIN Diodes were tested in a Co-60 gamma irradiation facility to see their capabilities as radiation sensors. We found an inexpensive commercial power pMOSFET that shows good linearity in their threshold voltage shift with radiation dose and a PIN diode that shows good linearity in its photo-current change with dose-rate. According to these findings, a radiation hardened hybrid electronic radiation dosimeter for nuclear robots has been developed for the first time. This small hybrid dosimeter has also an advantage in the point of view of reliability improvement by using a diversity concept.

  • PDF

필름배지선량계에 의한 개인피폭선량 측정에 관한 연구 (A Study on the Measurement of the Personal Exposure Dose by Film Badge Dosimeter)

  • 정운관
    • Journal of Radiation Protection and Research
    • /
    • 제19권1호
    • /
    • pp.37-50
    • /
    • 1994
  • X-선과 감마선의 에너지에 따른 선질특성과 선량 및 필름의 사진농도와의 관계를 이용한 필름배지선량계의 선량환산식을 실험적으로 체계화 하였고, 시간경과에 따른 잠상퇴행 특성과 방사선의 입사방향에 따른 방향특성을 실험적으로 조사하여 보정계수를 산출하였다. 본 연구에서 구한 선량환산식은 필름배지선량계의 기술기준인 성능판정 기준을 잘 만족시키는 것으로 나타났다.

  • PDF

ICRP 103 방사선방호 체계 하에서 유효선량 평가를 위한 Two-Dosimeter Algorithm의 적용방안 (Application of the Two-Dosimeter Algorithm for Effective Dose Evaluations based on ICRP Publication 103)

  • 김희근;공태영
    • Journal of Radiation Protection and Research
    • /
    • 제36권3호
    • /
    • pp.154-159
    • /
    • 2011
  • 국내 원전에서는 고 방사선량율 또는 고피폭 예상 방사선작업에 종사자의 가슴과 등에 두 개의 개인선량계를 패용하여 피폭방사선량을 평가하고 있다. 이러한 Two-Dosimeter Algorithm (TDA)으로 현장시험과 심층검토를 통해 NCRP(55:50) TDA를 최적 알고리즘으로 최종적으로 선정하였고, 2006년 이후 원전 종사자의 피폭방사선량 평가 실무에 적용 중에 있다. 한편, 2007년 국제방사선방호위원회(ICRP)는 간행물 ICRP 103을 통해 방사선가중계수 및 조직가중계수와 기준 인체모형팬텀(Reference phantom) 등을 일부 변경한 유효선량 평가방법을 제시하였다. 이에 따라 본 논문에서는 국내원전에서 적용되고 있는 NCRP (55:50) TDA에 대해 ICRP 103 방사선방호 체계 하에서의 계속 적용 타당성을 분석하였다. 그 결과, NCRP (55:50) TDA를 계속 사용하더라도 ICRP 103의 유효선량을 신뢰성 있게 평가할 수 있는 것으로 판단되었다.

Effect of D-(+)-Glucose on the Stability of Polyvinyl Alcohol Fricke Hydrogel Three-Dimensional Dosimeter for Radiotherapy

  • Yang, Yuejiao;Chen, Jie;Yang, Liming;Chen, Bin;Sheng, Zhenmei;Luo, Wenyun;Sui, Guoping;Lu, Xun;Chen, Jianxin
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.608-612
    • /
    • 2016
  • D-(+)-glucose (Glc) was added to the original Fricke polyvinyl alcohol-glutaraldehyde-xylenol orange (FPGX) hydrogel dosimeter system to make a more stable FPGX hydrogel three-dimensional dosimeter in this paper. Polyvinyl alcohol was used as a substrate, which was combined with Fricke solution. Various concentrations of Glc were tested with linear relevant fitting for optimal hydrogel production conditions. The effects of various formulations on the stability and sensitivity of dosimeters were evaluated. The results indicated that D-(+)-Glc, as a free radical scavenger, had a great effect on stabilizing the dose response related to absorbency and reducing the auto-oxidization of ferrous ions. A careful doping with Glc could slow down the color change of the dosimeter before and after radiation without any effect on the sensitivity of the dosimeter.

Novel Dosimeter for Low-Dose Radiation Using Escherichia coli PQ37

  • Park, Seo-Hyoung;Kim, Tae-Hwan;Cho, Chul-Koo;Lee, Yeon-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권3호
    • /
    • pp.524-528
    • /
    • 2001
  • The measurement of radiation response using simple and informative techniques would be of great value in studying the genetic risk following occupational, therapeutic, or accidental exposure to radiation. When patients receive radiation therapy, many suffer from side effects. Since each patient receives a different dose due to different physical conditions, it is important to measure the exact dose of radiation received by each patient to lessen the side effects. Even though several biological dosimetric systems have already been developed, there is no ideal system that can satisfy all the criteria for an idean dosimetric system, especially for low-dose radiation as used in radiation therapy. In this study, an SOS Chromotest of E. coli PQ37 was evaluated as a novel dosimeter for low-dose gamma-rays. E. coli PQ37 was originally developed to screen chemical mutagens using the SOS Chromotest-a colorimtric assay, based on the induction of ${\beta}$-galactosidase ue to DNA damage. The survival fraction of E. coli PQ37 decreased dose-dependently with an increasing dose of cobalt-60 gamma-rays. Also, a good linear correlation was found between the biological damage revealed by the ${\beta}$-galactosidase expression and the doses of gamma-rays. The expression of ${\beta}$-galactosidase activity that responded to low-dose radiation under 1 Gy was $Y=0.404+(0.089{\pm}0.3)D+(-0.018{\pm}0.16)D^2$ (Y, absorbance at 420 nm; D, Dose of irradiation) as calculated using Graph Pad In Plot and Excel. When a rabbit was fed with capsules containing an agar block embdded with E. coli PQ37 showed a linear response to the radiation doses. Accordingly, the results confirm that E. coli PQ37 can be used as a sensitive biological dosimeter fro cobalt-60 gamma-rays. To the best of our knowledge, this is the first time that a bacterium has been used as a biological dosimeter, especially for low-dose radiation.

  • PDF