Reduction of Scattered Radiation by Air Gap Technique for High Kilovoltage Chest Roentgenography (흉부(胸部) 고관전압(高管電壓) 촬영(撮影)에 있어 Air Gap Technique를 이용한 산란선(散亂線) 경감(輕減)에 관(關)한 연구(硏究))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Youn, Chul-Ho;Lee, Sang-Suk;Lim, Han-Young;Song, Jae-Kwan
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 1980
  • X-ray grid is the most important means to reduce the scattered ray from patients, but alternative way is air gap technique that is another name of Groedel technique. This technique is mainly used in chest radiography. Authors performed an experimental study on the air gap technique for chest radiography and obtained the results as follows; 1. In using the high voltage air technique, scattered ray could be reduced effectively, while the percentage of scattered ray was slightly increased than conventional grid technique. 2. In film contrast, 30cm air gap technique was inferior to 12:1 grid technique and contrast improvement was increased when the object was thicker and higher voltage was used. 3. The patient exposure dose was reduced about $25{\sim}45%$ compared with conventional grid technique by air gap technique used.

  • PDF

chemopreventive Effects of 2-(Allylthio) pyrazine

  • Kim, Nak-Doo;Kim, Sang-Geon
    • Archives of Pharmacal Research
    • /
    • v.22 no.2
    • /
    • pp.99-107
    • /
    • 1999
  • A series of organosulfur compounds were synthesized with the aim of developing chemopreventive compounds active against hepatotoxicity and chemical carcinogesis. 2-(Allylthio) prazine (2-AP) was effective in inhibiting cytochrome P450 2E1-mediated catalytic activities and protein expression, and in inducing microsomal epoxide hydrolase and major glutathione S-transferases. 2-AP reduced the hepatotoxicity caused by toxicant sand elevated cellular GSH content. Development of skin tumors, pulmonary adenoma and aberrant crypt foci in colon by various chemical carcinogens was inhibited by 2-AP pretreatment. Anticarcinogenic effects of 2-AP at the stage of initiation of tumors were also observed in the aflatoxin B1 ($AFB_1$)-induced three-step medium-term hepatocarcinogenesis model. Reduction of $AFB_1$-DNA adduct by 2-AP appeared to result from the decreased formation of $AFB_1$-8,9-epoxide via suppression of cytochrome P450, while induction of GST 2-AP increases the excretion of glutathione-conjugated $AFB_1$ . 2-AP was a radioprotective agent effective against the lethal dose of total body irradiation and reduced radiation-induced injury in association with the elevation of detoxifying gene expression. 2-AP produces reactive oxygen species in vivo, which is not mediated with the thiol-dependent production of oxidants and that NF-KB activation is not involved in the induction of the detoxifying enzymes. the mechanism of chemoprotection by 2-AP may involve inhibition of the P450-mediated metabolic activation of chemical carcinogens and enhancement of electrophilic detoxification through induction of phase II detoxification enzymes which would facilitate the clearance of activated metabolites through conjugation reaction.

  • PDF

Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix (자궁암 치료용 다채널 초음파 온열치료기)

  • Lee Rena
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this study was to construct multi-element ultrasound applicators for the treatment of gynecologic cancer with high dose rate brachytherapy. For the treatment of uterus, piezo-ceramic crystal transducer (PZT -5A) with outer diameter of 4 mm, wall thickness of 1.3 mm, and length of 24.5 mm was selected. For the treatment of cervix or vagina, it should be possible to insert the applicator into the vagina. Thus, a cylindrical PZT -8 material with outer diameter of 24.5 mm, wall thickness of 1.3 mm, and length of 15.2 mm was selected. The operating frequencies determined by vector impedance measurement were 3.2 MHz for the PZT 5A cylinder (OD=4 mm) and 1.7 MHz for the PZT -8 cylinder (OD: 24.5 mm). The ratios of generated acoustic output power to applied electric power were 33% and 61% for the tandem type crystal and the cylinder type crystal, respectively. The radiated acoustic pressure fields from both transducers were calculated using a Matlab code and measured in water using hydrophone. There was good agreement between measured and calculated acoustic pressure field distribution. For a tandem type transducer, the calculated acoustic pressure field decreased from 0.023 MPa at 10 mm to 0.010 Mpa at 30 mm, the reduction of 57%. For the cylinder type transducer which will be used for the treatment of vagina showed 78% reduction at 15 mm and 66% at 25 mm as compared to values at 5 mm from the surface. Based on the characteristics of the transducers, this study demonstrated the possibility of using the crystals as a heating source. Finally, a 3-element and 4-element prototype applicators were constructed. The 3-element applicator is 75 mm long and 4 mm thick and will be used for the treatment of uterus. The 4-element applicator is 61 mm long and 24.5 mm thick and will be used for the treatment of vagina. Using these applicators, it is possible to generate enough power to increase temperature to therapeutic level.

  • PDF

USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN (전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가)

  • Park, Do-Geun;Choe, Byeong-Gi;Kim, Jin-Man;Lee, Dong-Hun;Song, Gi-Won;Park, Yeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.127-135
    • /
    • 2014
  • Purpose : By taking advantage of each imaging modality, the use of fused CT/MRI image has increased in prostate cancer radiation therapy. However, fusion uncertainty may cause partial target miss or normal organ overdose. In order to complement such limitation, our hospital acquired MRI image (Planning MRI) by setting up patients with the same fixing tool and posture as CT simulation. This study aims to evaluate the usefulness of the Planning MRI through comparing and analyzing the diagnostic MRI image and Planning MRI image. Materials and Methods : This study targeted 10 patients who had been diagnosed with prostate cancer and prescribed nonhormone and definitive RT 70 Gy/28 fx from August 2011 to July 2013. Each patient had both CT and MRI simulations. The MRI images were acquired within one half hour after the CT simulation. The acquired CT/MRI images were fused primarily based on bony structure matching. This study measured the volume of prostate in the images of Planning MRI and diagnostic MRI. The diameters at the craniocaudal, anteroposterior and left-to-right directions from the center of prostate were measured in order to compare changes in the shape of prostate. Results : As a result of comparing the volume of prostate in the images of Planning MRI and diagnostic MRI, they were found to be $25.01cm^3$(range $15.84-34.75cm^3$) and $25.05cm^3$(range $15.28-35.88cm^3$) on average respectively. The diagnostic MRI had an increase of 0.12 % as compared with the Planning MRI. On the planning MRI, there was an increase in the volume by $7.46cm^3$(29 %) at the transition zone directions, and there was a decrease in the volume by $8.52cm^3$(34 %) in the peripheral zone direction. As a result of measuring the diameters at the craniocaudal, anteroposterior and left-to-right directions in the prostate, the Planning MRI was found to have on average 3.82cm, 2.38cm and 4.59cm respectively and the diagnostic MRI was found to have on average 3.37cm, 2.76cm and 4.51cm respectively. All three prostate diameters changed and the change was significant in the Planning MRI. On average, the anteroposterior prostate diameter decrease by 0.38cm(13 %). The mean right-to-left and craniocaudal diameter increased by 0.08cm(1.6 %) and 0.45cm(13 %), respectively. Conclusion : Based on the results of this study, it was found that the total volumes of prostate in the Planning MRI and the diagnostic MRI were not significantly different. However, there was a change in the shape and partial volume of prostate due to the insertion of prostate balloon tube to the rectum. Thus, if the Planning MRI images were used when conducting the fusion of CT/MRI images, it would be possible to include the target in the CTV without a loss as much as the increased volume in the transition zone. Also, it would be possible to reduce the radiation dose delivered to the rectum through separating more clearly the reduction of peripheral zone volume. Therefore, the author of this study believes that acquisition of Planning MRI image should be made to ensure target delineation and localization accuracy.

A Study on the Effect of "ADAPTAGEN"$^{\textregistered}$ Korean Ginseng Components, for the Injured Mouse by X-ray($^{60}Co$) Irradiation (X-방사선($^{60}Co$)에 조사된 새앙쥐의 상해에 대한 "아답태겐"$^{\textregistered}$의 효과에 관한 연구)

  • 공태훈;유성렬
    • Journal of Ginseng Research
    • /
    • v.15 no.3
    • /
    • pp.171-178
    • /
    • 1991
  • The results ok feeding experiments to the mice with ginseng extract, ginseng Powder, and ADAPTAGEN, for 30 days before X-ray irradiation and for 40 days after the X-ray irradiation at 750 rads were as follow: 1. The 50% lethals days (LD50, ) by the X-ray irradiation were 9 days at 1, 000 rads. 10 days at 900 rads, 11 days at 800 rads, 14 days at 760 rads, and 19 darts at 750 rads. Therefore, the standard radiation dose was set at 750 radb/8 min. 2. The 80% of the control group mice exposed to the X-ray radiation without ginseng feeding died in periods ranging from 14 to 24 days and the 20~30% of the ginseng extract and ginseng powder feeding groups died. But the 100% of the mice fed with ADAPTAGEN survived. 3. Testicles of the control group became smaller in weight than the nomad group by 26.5 to 29.0% and those of the ginseng extract and ginseng powder feeding group reduced by 44.6 to 60.4%. However, testicles of the ADAPTiIGEN feeding group increased in size by 77.4% to 87.1% and in weight by 61%, showing a recovery phenomenon approarhing to those of the ordinary mice. The ADAPTAGEN feeding group mice were also as active in color as the ordinary ones. 4. An electron micrograph(X8, 000X2.2) of the liver cells of the mice which had been 40 days after X-ray irradiation showed as follows; The control group appeared that is physiological action stopped due to the frequent occurrence of morphological change of the nucleus and diffusion of chromosome, reduction in microspores and expansion of microsomts, and endoplasmic change of mitochondria. The liver cells or the ADAPTAGEN feeding group were in a state similar to those of the ordinary mice restoring to normalcy In contrast, the liver cells of the ginseng extract and ginseng powder feeding groups were still far from being normal. 5. A serological analysis showed that the control group sharply decreased in albumin, Y-g1obu1in, and IgG so far as to cause dystrophy and to weaken antibody resistance but that ginseng extract and ginseng powder feeding groups, though in a little more restoring state than the control group, were still far from the normal group. The ADAPTAGEN feeding group restored to a state as comparable to the normal group in the contents of albumin ${\gamma}$-globulin, IgG and serum protein. In order words, it is noteworthy that ADAPTAGEN feeding was effective in revitalizing the destroyed cells of a living body and that it has the function of normalizing antibody components.

  • PDF

Effects of Different UV-B Levels on Growth, Antioxidant Contents and Activities of Related Enzymes in Cucumber(Cucumis sativus L.). (UV-B 강도 변화가 오이의 생장 및 항산화 물질 함량과 관련 효소의 활성에 미치는 영향)

  • Kim, Hak-Yoon;Shin, Dong-Hyun;Kim, Kil-Ung
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.4
    • /
    • pp.309-313
    • /
    • 2000
  • To investigate the effects of different UV-B levels on growth and biochemical defense response in plants, cucumber plants were subjected to three levels of biologically effective ultraviolet-B $(UV-B_{BE})$ radiation [daily dose: 0.03 (No), 6.40 (Low) and $11.30\;(High)\;kJ{\cdot}m^{-2}$, $UV-B_{BE}$] in the growth chambers for 3 weeks during the early growth period. Enhanced UV-B radiation drastically decreased both dry weight and leaf area of cucumber. With increasing UV-B intensity, chlorophyll content was decreased, however the level of malondialdehyde was highly increased linearly. Total contents of ascorbic acid and glutathione were tended to increase by UV-B, while the ratios of dehydroascorbate/ascorbate and oxidized glutathione/reduced glutathione were significantly increased with increasing UV-B intensity in cucumber. All the enzyme activities investigated (superoxide dismutase, ascorbate peroxidase, dehydroascorbate reductase, guaiacol peroxidase etc.) in cucumber were increased by the UV-B enhancement. These results suggested that enhanced UV-B irradiation caused photooxidative stress in cucumber plant and resulted in significant reduction in plant growth. Biochemical protection responses might be activated to prevent the leaves from damaging effects of oxidative stress generated by UV-B irradiation.

  • PDF

Evaluation of Phototoxicity for Cosmetics and Alternative Method (화장품 광독성 평가와 동물대체시험법)

  • Lee, Jong-Kwon;Sin, Ji-Soon;Kim, Jin-Ho;Eom, Jun-Ho;Kim, Hyung-Soo;Park, Kui-Lea
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.3 s.52
    • /
    • pp.245-251
    • /
    • 2005
  • Safety is one of the key issue in the regulation of cosmetics. Cosmetic Act deals with it in Korea. The guidance for the testing cosmetic ingredients and their safety evaluation are prepared by Korea Food and Drug Administration. Ultraviolet radiation could Induce skin damage, edema, erythema, photoaging, immune dysfunction and skin cancer. Ultraviolet radiation is classified as Group 2A(probably carcinogenic to humans) by International Agenry for Reaserch on Cancer(IARC). The in vitro methodologies for evaluating the toxic potential of ingredients reported in the literature have not yet been sufficiently validated for use in areas other than the study for mutagenicity/genotoxicity, for pre-screening for severe irritancy, for screening of phototoxicity and for evaluating the percutaneous absorption. The 3T3 neutral red uptake photoxicity test (3T3 NRU PT) was accepted as OECD toxicity guideline in 2002. The 3T3 NRU PT is an in vitro method based on a comparison of the cytotoxicitv of a chemical when tested in the presence and in the absence of exposure to a non-cytotoxic dose of UVA/visible light.

An Efficient CT Image Denoising using WT-GAN Model

  • Hae Chan Jeong;Dong Hoon Lim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.5
    • /
    • pp.21-29
    • /
    • 2024
  • Reducing the radiation dose during CT scanning can lower the risk of radiation exposure, but not only does the image resolution significantly deteriorate, but the effectiveness of diagnosis is reduced due to the generation of noise. Therefore, noise removal from CT images is a very important and essential processing process in the image restoration. Until now, there are limitations in removing only the noise by separating the noise and the original signal in the image area. In this paper, we aim to effectively remove noise from CT images using the wavelet transform-based GAN model, that is, the WT-GAN model in the frequency domain. The GAN model used here generates images with noise removed through a U-Net structured generator and a PatchGAN structured discriminator. To evaluate the performance of the WT-GAN model proposed in this paper, experiments were conducted on CT images damaged by various noises, namely Gaussian noise, Poisson noise, and speckle noise. As a result of the performance experiment, the WT-GAN model is better than the traditional filter, that is, the BM3D filter, as well as the existing deep learning models, such as DnCNN, CDAE model, and U-Net GAN model, in qualitative and quantitative measures, that is, PSNR (Peak Signal-to-Noise Ratio) and SSIM (Structural Similarity Index Measure) showed excellent results.

Development of Spent Nuclear Fuel Transportation Worker Exposure Scenario by Dry Storage Methods (건식 저장방식별 사용후핵연료 운반 작업자 피폭시나리오 개발)

  • Geon Woo Son;Hyeok Jae Kim;Shin Dong Lee;Min Woo Kwak;Kwang Pyo Kim
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.43-52
    • /
    • 2024
  • Currently, there are no interim storage facilities and permanent disposal facilities in Korea, so all spent nuclear fuels are temporarily stored. However, the temporary storage facility is approaching saturation, and as a measure to this, the 2nd Basic Plan for the Management of High-Level Radioactive Waste presented an operation plan for dry interim storage facilities and dry temporary storage facilities on the NPP on-site. The dry storage can be operated in various ways, and to select the optimal dry storage method, the reduction of exposure for workers must be considered. Accordingly, it is necessary to develop a worker exposure scenario according to the dry storage method and evaluate and compare the radiological impact for each method. The purpose of this study is to develop an exposure scenario for workers transporting spent nuclear fuel by dry storage method. To this end, first, the operation procedure of the foreign commercial spent nuclear fuel dry storage system was analyzed based on the Final Safety Analysis Report (FSAR). 1) the concrete overpack-based system, 2) the metal overpack-based system, and 3) the vertical storage module-based system were selected for analysis. Factors were assumed that could affect the type of work (working distance, working hours, number of workers, etc.) during transportation work. Finally, the work type of the processes involved in transporting spent nuclear fuel by dry storage method was set, and an exposure scenario was developed accordingly. The concrete overpack method, the metal overpack method, and the vertical storage module method were classified into a total of 31, 9, and 23 processes, respectively. The work distance, work time, and number of workers for each process were set. The product of working hours and number of workers (Man-hour) was set high in the order of concrete overpack method, vertical storage module method, and metal overpack method, and short-range work (10 cm) was most often applied to the concrete overpack method. The results of this study are expected to be used as basic data for performing radiological comparisons of transport workers by dry storage method of spent nuclear fuel.

Study on the Institutional Control Period Through the Post-drilling Scenario Of Near Surface Disposal Facility for Low and Intermediate-Level Radioactive Waste (중·저준위 방사성폐기물 천층처분시설에서 시추 후 거주시나리오 평가를 통한 폐쇄 후 제도적 관리기간 연구)

  • Hong, Sung-Wook;Park, Jin-Baek;Yoon, Jung-Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.1
    • /
    • pp.59-68
    • /
    • 2014
  • The public's access to the disposal facilities should be restricted during the institutional control period. Even after the institutional control period, disposal facilities should be designed to protect radiologically against inadvertent human intruders. This study is to assess the effective dose equivalent to the inadvertent intruder after the institutional control period thorough the GENII. The disposal unit was allocated with different kind of radioactive waste and the effects of the radiation dose to inadvertent intruder were evaluated in accordance with the institutional control period. As a result, even though there is no institutional control period, all were satisfied with the regulatory guide, except for the disposal unit with only spent filter. However, the disposal unit with only spent filter was satisfied with the regulatory guide after the institutional control period of 300 years. But the disposal unit with spent filter mixed with dry active waste could shorten the institutional control period. So the institutional control period can be reduced through the mixing the other waste with spent filter in disposal unit. Therefore, establishing an appropriate plan for the disposal unit with spent filter and other radioactive waste will be effective for radiological safety and reduction of the institutional control period, rather than increasing the institutional control period and spending costs for the maintenance and conservation for the disposal unit with only spent filter.