• Title/Summary/Keyword: Radiation Correction

Search Result 338, Processing Time 0.026 seconds

Effect of Inhomogeneity correction for lung volume model in TPS (Lnug Volume을 모델로 한 방사선치료계획 시 불균질 조직 보정에 따른 효과)

  • Chung SeYoung;Lee SangRok;Kim YoungBum;Kwon YoungHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Introduction : The phantom that includes high density materials such as steel was custom-made to fix lung and bone in order to evaluation inhomogeneity correction at the time of conducting radiation therapy to treat lung cancer. Using this, values resulting from the inhomogeneous correction algorithm are compared on the 2 and 3 dimensional radiation therapy planning systems. Moreover, change in dose calculation was evaluated according to inhomogeneous by comparing with the actual measurement. Materials and Methods : As for the image acquisition, inhomogeneous correction phantom(Pig's vertebra, steel(8.21g/cm3), cork(0.23 g/cm3)) that was custom-made and the CT(Volume zoom, Siemens, Germany) were used. As for the radiation therapy planning system, Marks Plan(2D) and XiO(CMS, USA, 3D) were used. To compare with the measurement value, linear accelerator(CL/1800, Varian, USA) and ion chamber were used. Image, obtained from the CT was used to obtain point dose and dose distribution from the region of interest (ROI) while on the radiation therapy planning device. After measurement was conducted under the same conditions, value on the treatment planning device and measured value were subjected to comparison and analysis. And difference between the resulting for the evaluation on the use (or non-use) of inhomogeneity correction algorithm, and diverse inhomogeneity correction algorithm that is included in the radiation therapy planning device was compared as well. Results : As result of comparing the results of measurement value on the region of interest within the inhomogeneity correction phantom and the value that resulted from the homogeneous and inhomogeneous correction, gained from the therapy planning device, margin of error of the measurement value and inhomogeneous correction value at the location 1 of the lung showed $0.8\%$ on 2D and $0.5\%$ on 3D. Margin of error of the measurement value and inhomogeneous correction value at the location 1 of the steel showed $12\%$ on 2D and $5\%$ on 3D, however, it is possible to see that the value that is not correction and the margin of error of the measurement value stand at $16\%$ and $14\%$, respectively. Moreover, values of the 3D showed lower margin of error compared to 2D. Conclusion : Revision according to the density of tissue must be executed during radiation therapy planning. To ensure a more accurate planning, use of 3D planning system is recommended more so than the 2D Planning system to ensure a more accurate revision on the therapy plan. Moreover, 3D Planning system needs to select and use the most accurate and appropriate inhomogeneous correction algorithm through actual measurement. In addition, comparison and analysis through TLD or film dosimetry are needed.

  • PDF

A Study on Atmospheric Correction in Satellite Imagery Using an Atmospheric Radiation Model (대기복사모형을 이용한 위성영상의 대기보정에 관한 연구)

  • Oh, Sung-Nam
    • Atmosphere
    • /
    • v.14 no.2
    • /
    • pp.11-22
    • /
    • 2004
  • A technique on atmospheric correction algorithm to the multi-band reflectance of Landsat TM imagery has been developed using an atmospheric radiation transfer model for eliminating the atmospheric and surface diffusion effects. Despite the fact that the technique of satellite image processing has been continually developed, there is still a difference between the radiance value registered by satellite borne detector and the true value registered at the ground surface. Such difference is caused by atmospheric attenuations of radiance energy transfer process which is mostly associated with the presence of aerosol particles in atmospheric suspension and surface irradiance characteristics. The atmospheric reflectance depend on atmospheric optical depth and aerosol concentration, and closely related to geographical and environmental surface characteristics. Therefore, when the effects of surface diffuse and aerosol reflectance are eliminated from the satellite image, it is actually corrected from atmospheric optical conditions. The objective of this study is to develop an algorithm for making atmospheric correction in satellite image. The study is processed with the correction function which is developed for eliminating the effects of atmospheric path scattering and surface adjacent pixel spectral reflectance within an atmospheric radiation model. The diffused radiance of adjacent pixel in the image obtained from accounting the average reflectance in the $7{\times}7$ neighbourhood pixels and using the land cover classification. The atmospheric correction functions are provided by a radiation transfer model of LOWTRAN 7 based on the actual atmospheric soundings over the Korean atmospheric complexity. The model produce the upward radiances of satellite spectral image for a given surface reflectance and aerosol optical thickness.

Stem Effect Correction Factor of Ionization Chamber in Exposure Measurements of High Energy Photons (고 에너지 광자선의 조사선량 측정 시 전리함의 스템효과 보정계수)

  • Park, Cheol-Woo;Lee, Jae-Seung;Kweon, Dae-Chel;Cha, Dong-Soo;Kim, Jin-Soo;Kim, Kyoung-Keun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2010
  • Ionization chambers often exhibit a stem effect, caused by interactions of radiation with air near the chamber end, or with dielectric in the chamber stem or cable. In this study measured stem effect correction factor for length of ionization chamber from medical linear accelerator recommend to with the use of stem correction method. For a model of the Farmer-type chamber, were used to calculate the beam quality correction factor. These interactions contribute to the apparent measured exposure. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field. Linear accelerator generated photons energy and increased dose repeatedly measured by using stem correction method. Stem effect was dependence of the energy and increases with photon energy conditions improved of beam quality. In conclusion, stem effect correction factor was measured within 0.4% calculated according to the exposures stem length and also supposed to determined below 1% of another stem correction method.

  • PDF

Methodology for Calculating Correction Factors to Improve the Accuracy of Radiation Dose Predictions for High-Exposure Tasks in Nuclear Power Plants Using Computational Scenarios (원전 고피폭 작업의 예측 피폭선량 정확도 개선을 위한 전산코드 시나리오 보정인자 도출 방법론)

  • Changju Song;Tae Young Kong;Jiung Kim;Jaeok Park;Seungho Jo;Hee Geun Kim;Yongkwon Kim
    • Journal of Radiation Industry
    • /
    • v.18 no.3
    • /
    • pp.223-226
    • /
    • 2024
  • It is essential to precisely evaluate the expected dose (collective dose) before performing high-exposure tasks in nuclear power plants because those have a high potential to cause significant radiation exposure to workers. A dose evaluation method is to design the scenarios of high-exposure tasks using computational codes, which allows for the calculation of the expected collective dose. Although these computational scenarios are useful for estimating the expected radiation dose and establishing radiation protection plans, the calculated doses may not perfectly match the actual doses that workers receive during tasks due to differences between the scenario and the actual circumstances in the radiation fields. Therefore, this study presents a methodology for calculating correction factors to improve the accuracy of dose predictions from computational scenarios. This approach aims to make the predicted collective dose before the task closer to the actual dose received by workers, thereby enhancing radiation safety for personnel performing high-exposure tasks. Additionally, these correction factors will help accurately predict doses under various working conditions in the future, contributing to minimizing radiation exposure risks for nuclear power plant workers.

An Experimental Study on the Scale Correction of Measured Horizontal Global Solar Radiation (수평면 전일사량 측정데이터 보정에 관한 실험적 연구)

  • Song, Su-Won
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.25-31
    • /
    • 2010
  • A Precision Spectral Pyranometer (PSP) is mainly used as a reference to calibrate other pyranometers due to its high accuracy and sensitivity in response to the spectrum wavelength range of 0.285 ${\mu}$ to 2.8 ${\mu}$, while the sensitivity of photovoltaic-type Li-Cor pyranometer is limited within a certain spectral range from 0.4 ${\mu}$ to 1.1 ${\mu}$. In this study, two Eppley PSPs($PSP_1$ and $PSP_2$) were first compared to the calibrated Eppley PSPs from National Renewable Energy Laboratory (NREL), resulting in two linear correction factors based on the comparison between the logger output (V) from the test PSP and the solar radiation (W/m2) from the NREL PSP. The Li-Cor pyranometer used in this study was then corrected based on the comparison of measured solar radiation ($W/m^2$) from the corrected $PSP_1$ and the Li-Cor pyranometer. In addition, instrument scale corrections were also performed for the PSPs and the Li-Cor from the transmitter to the data logger. From the comparisons, a linear correction factor (1.0214) with R=0.9998 was developed for the scale correction between$PSP_1$ and $PSP_2$, while the Li-Cor pyranometer has a scale(1.0597) and offset (32.046) with R=0.9998 against$PSP_1$. As a result, it was identified that there were good agreements within ${\pm}$ 10 W/ $m^2$ between Eppley $PSP_1$ vs. $PSP_2$ solar radiation and within ${\pm}$ 20 W/$m^2$ between$PSP_1$ vs Li-Cor solar radiation after the empirical scale corrections developed in this study.

Atmospheric Correction of Sentinel-2 Images Using Enhanced AOD Information

  • Kim, Seoyeon;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.1
    • /
    • pp.83-101
    • /
    • 2022
  • Accurate atmospheric correction is essential for the analysis of land surface and environmental monitoring. Aerosol optical depth (AOD) information is particularly important in atmospheric correction because the radiation attenuation by Mie scattering makes the differences between the radiation calculated at the satellite sensor and the radiation measured at the land surface. Thus, it is necessary to use high-quality AOD data for an appropriate atmospheric correction of high-resolution satellite images. In this study, we examined the Second Simulation of a Satellite Signal in the Solar Spectrum (6S)-based atmospheric correction results for the Sentinel-2 images in South Korea using raster AOD (MODIS) and single-point AOD (AERONET). The 6S result was overall agreed with the Sentinel-2 level 2 data. Moreover, using raster AOD showed better performance than using single-point AOD. The atmospheric correction using the single-point AOD yielded some inappropriate values for forest and water pixels, where as the atmospheric correction using raster AOD produced stable and natural patterns in accordance with the land cover map. Also, the Sentinel-2 normalized difference vegetation index (NDVI) after the 6S correction had similar patterns to the up scaled drone NDVI, although Sentinel-2 NDVI had relatively low values. Also, the spatial distribution of both images seemed very similar for growing and harvest seasons. Future work will be necessary to make efforts for the gap-filling of AOD data and an accurate bi-directional reflectance distribution function (BRDF) model for high-resolution atmospheric correction. These methods can help improve the land surface monitoring using the future Compact Advanced Satellite 500 in South Korea.

MONTE CARLO SIMULATION FOR CORRECTION OF IONIZATION CHAMBER WALL

  • Kurosawa, Tadahiro;Takata, Nobuhisa;Koyama, Yasuji
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.271-273
    • /
    • 2001
  • In precise measurement of air kerma with cavity ionization chambers, the effect of wall attenuation and scatter are corrected by Kwall and that of nonuniformity by Knu. Using the EGS4 code, we calculated these two correction factors. Correction factors calculated for two different-sized cylindrical ionization chamber differ by up to 0.7% from those obtained by measurements.

  • PDF

PIXEL-BASED CORRECTION METHOD FOR GAFCHROMIC®EBT FILM DOSIMETRY

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong;Ju, Sang-Gyu;Shin, Jung-Suk;Kim, Jin-Sung;Park, Joo-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.670-679
    • /
    • 2010
  • In this paper, a new approach using a pixel-based correction method was developed to fix the non-uniform responses of flat-bed type scanners used for radiochromic film dosimetry. In order to validate the method's performance, two cases were tested: the first consisted of simple dose distributions delivered by a single port; the second was a complicated dose distribution composed of multiple beams. In the case of the simple individual dose condition, ten different doses, from 8.3 cGy to 307.1 cGy, were measured, horizontal profiles were analyzed using the pixel-based correcton method and compared with results measured by an ionization chamber and results corrected using the existing correction method. A complicated inverse pyramid dose distribution was made by piling up four different field shapes, which were measured with GAFCHROMIC$^{(R)}$EBT film and compared with the Monte Carlo calculation; as well as the dose distribution corrected using a conventional method. The results showed that a pixel-based correction method reduced dose difference from the reference measurement down to 1% in the flat dose distribution region or 2 mm in a steep dose gradient region compared to the reference data, which were ionization chamber measurement data for simple cases and the MC computed data for the complicated case, with an exception for very low doses of less than about 10 cGy in the simple case. Therefore, the pixel-based scanner correction method is expected to enhance the accuracy of GAFCHROMIC$^{(R)}$EBT film dosimetry, which is a widely used tool for two-dimensional dosimetry.