• Title/Summary/Keyword: Radiation Condition

Search Result 1,129, Processing Time 0.024 seconds

Study on Characteristics of Radiation Environment in the Urban through the Field Observation in the Summer (하절기 도시의 장.단파 복사특성 관측)

  • Jung, Im-Soo;Choi, Dong-Ho;Lee, Bu-Yong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.105-110
    • /
    • 2011
  • The objective of this study is to analyze the characteristic of radiation environment in the urban and rural through the field observation in the summer. The radiation balance was compared through the measurement of the shortwave radiation and long-wave radiation in the urban, sub-urban, and rural. The following conclusion could be obtained from this research. (1) In the results of observation including the rain-day, it was found that the short wave radiance in the urban is lower about 10% than the rural. (2) The upper part of atmosphere layers in the urban area absorb much short wave radiation energies compared with the rural relatively. It can increase the temperature of the upper part of atmosphere layers and the emittance of long wave radiation. (3) The ratio of the downward short wave radiation to the downward long wave radiation was 1.24 for the urban, 1.28 for sub-urban and1.35 for rural. It can be estimated that the atmosphere condition of the rural is better than that of other areas.

  • PDF

A Basic Study on Urban Radiation Heat Transfer (도시의 방사전열에 관한 기초 연구)

  • Kim, C.M.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.35-43
    • /
    • 2002
  • This research makes that quantitative radiation property of an actual town ward is obtained in quest of the parameter with regard to a radiation heat transfer property and set up several town ward models that reproduced a solid form of a city along the attribute of the city. A regular trend possibility that is able to evaluate a radiation characteristics of a town ward quantitatively from a town ward guideline and confirmation that is produced about each parameter as a result of a numerical value simulation it obtained. This research shot a coefficient of Gebhart's emission absorption. sky radiation absorption rate direct solar radiation absorption rate the parameter with regard to a radiation heat transfer characteristics of a town ward in each town ward model and a volume rate of a town ward advances case study under regular such condition and shot the absorption rate, direct and others days and calculated an absorption rate and checked about the relation between a town ward and each radiation heat transfer property of a city.

Radiation Effects on Fiber Bragg Grating Sensors Written in UV KrF Laser Process Condition (UV KrF 레이저 공정조건에 따른 FBG 센서의 방사선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.161-166
    • /
    • 2016
  • We studied the effect of $Co^{60}$ gamma-radiation on the FBGs by a variation of grating the fabrication parameters. The FBGs were fabricated in a different UV KrF laser intensity using the same boron co-doped photo-sensitive fiber and exposed to gamma-radiation up to a dose of 33.8 kGy. According to the experimental data and analysis results, We confirmed that the laser intensity for grating inscription has a highly effect on the radiation sensitivity of the FBGs and the radiation-induced Bragg wavelength shift by the change of laser process condition showed a difference more than about 30 %.

The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System (진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리)

  • Kim, Sang-Woo;Rhim, Jea-Dong;Han, Dong-Kyoon;Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

On the Method of Rankine Source Distribution for Free Surface Flow Problem: Radiation Condition and Influence of Finite Distribution (자유표면문제해석(자유표면문제해석)을 위한 Rankine용출점(湧出點) 분포법(分布法) -방사조건(放射條件)과 유한분포(有限分布)의 영향-)

  • Chang-Sup,Lee;Seung-Il,Yang;Chang-Gu,Kang
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.19 no.2
    • /
    • pp.13-18
    • /
    • 1982
  • The method of Rankine source distribution is emerging as a powerful yet simple alternative for the solution of complicated free surface problems. But it has been uncertain whether the radiation condition could be satisfied exactly by distributing the simple sources on the free surface only. In this paper, it is proved rigorously that the Rankine sources, whose intensities are varying sinusoidally along the axis satisfying the free surface boundary condition, generate the radiation waves both in the infinite and finite-depth flows. A formula is derived to give the upper and lower bounds of the errors in the induced velocity computation that will be introduced by truncating the extent of source distribution on the free surface. Since the truncation is inevitable in the numerical analysis, this formula may be used as a criterion to limit the position of the field points, where velocity computation is made, away from the truncation boundary. A typical analysis shows that the maximum error will be 3.4 percent of the exact induced velocity when the field point is on the free surface two wave lengths away from the truncation boundary.

  • PDF

Characteristics of Alpha Particle Track on Cellulose Nitrate Film (Cellulose Nitrate의 알파입자비적특성(粒子飛跡特性))

  • Do, Jin-Yeol;Jun, Jae-Shik;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.61-66
    • /
    • 1984
  • A study on the characteristics of ${\alpha}$-particle track on cellulose nitrate film was carried out with a particular emphasis on the dependence of track diameter upon chemical etching condition. The track diameters etched in KOH solution appeared to be, on average, three times larger than those etched in NaOH under the same etching condition. The relationship between the track diameters and both etching time and the energy of incident ${\alpha}$-particles was also investigated. It is shown that the particle fluence rate is fairly independent of etching time as far as the condition of irradiation remains unchanged.

  • PDF

The present condition and improvement program of the diagnostic safety management (진단용방사선발생장치의 안전관리 문제점과 개선방안)

  • Seo Jae Lyong
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.260-268
    • /
    • 2001
  • Ⅰ. Introduction : 'The regulation for the safety management of diagnostic radiation apparatus' legislated and it has been managed systematially. So that, it enables a national health to be protected from harmful radiation. But, managers and administers of

  • PDF

Fluoroscopic Radiation Exposure during Percutaneous Kyphoplasty

  • Choi, Hyun-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.1
    • /
    • pp.37-42
    • /
    • 2011
  • Objective: The author measured levels of fluoroscopic radiation exposure to the surgeon's body based on the different beam directions during kyphoplasty. Methods: This is an observational study. A series of 84 patients (96 vertebral bodies) were treated with kyphoplasty over one year. The patients were divided into four groups based on the horizontal and vertical directions of the X-Ray beams. We measured radiation exposure with the seven dosimetry badges which were worn by the surgeon in each group (total of 28 badges). Twenty-four procedures were measured in each group. Cumulative dose and dose rates were compared between groups. Results: Fluoroscopic radiation is received by the operator in real-time for approximately 50% (half) of the operation time. Thyroid protectors and lead aprons can block radiation almost completely. The largest dose was received in the chest irrespective of beam directions. The lowest level of radiation were received when X-ray tube was away from the surgeon and beneath the bed (dose rate of head, neck, chest, abdomen and knee: 0.2986, 0.2828, 0.9711, 0.8977, 0.8168 mSv, respectively). The radiation differences between each group were approximately 2.7-10 folds. Conclusion: When fluoroscopic guided-KP is performed, the X-Ray tube should be positioned on the opposite side of the operator and below the table, otherwise the received radiation to the surgeon's body would be 2.7-10 times higher than such condition.

Radiation Effects on the Flame Structure and Extinction Limit of Counterflow Partially Premixed Methane Flames Diluted with Water Vapor in the Air Stream (공기류측에 수증기가 첨가된 대향류 메탄 부분예혼합화염의 화염구조 및 소화한계에 미치는 복사효과)

  • Park, Ji-Woong;Oh, Chang Bo;Kim, Ook Joong
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.325-328
    • /
    • 2012
  • Radiation effects on the partially premixed methane flames diluted with water vapor in the air stream were numerically investigated. OPPDIF code and GRI-v3.0 were used in the numerical simulation. Adiabatic condition was compared with two different radiation models, optically-thin and WSGGM models. It was found that the radiation effect on the flame structure for the equivalence ratio (${\Phi}$) of 2.5 was less than ${\Phi}=1.5$. Extinction limit was not affected significantly, however, local flame structure was markedly influenced by the radiation models as increasing the water vapor concentration.

  • PDF

An Analysis of the Characteristics of Corrugated Horn for Feeding Beam-waveguide Antenna (빔 웨이브가이드 안테나의 급전을 위한 원뿔형 컬러게이트 혼의 특성 해석)

  • 백경훈;이상설
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.5
    • /
    • pp.666-671
    • /
    • 1990
  • The characteristics of the corrugated conical horn antenna for the satellite communication earth station operating at C band is analyzed and its radiation patterns is measured. We obtain the characterstic equations for corrugated horn in the condition that the balanced hybrid mode is formed on born aperture and calculate radiation patterns in the Fresnel region from the aperture integral expressions obtained by the equivalence principle. The radiation patterns which are calculated for the frequency of 3.85GHz and 6.18GHz are well agreed with the measured data.

  • PDF