• Title/Summary/Keyword: Radiation Condition

Search Result 1,120, Processing Time 0.026 seconds

Sound Radiation Characteristics of Rectangular Plates with a Guided Edge Condition (모서리의 경계조건이 가이드 조건인 사각 평판의 음향방사 특성 연구)

  • Yoo, Ji-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.9
    • /
    • pp.876-883
    • /
    • 2009
  • The radiation of sound from a rectangular plate with a guided edge condition is investigated. By taking this particular boundary condition into account, simple analytical forms of the average radiation efficiency and radiation power based on the modal approach can be found, where the cross-modal terms can average out for all possible point excitation locations. Design variables of the plate such as thickness, aspect ratio, and damping that are closely related to the sound radiation are mainly discussed. The radiation power of the guided plate is found to be governed by the piston mode as well as the critical frequency. While both the radiation efficiency and the radiation power seem to be influenced by thickness and a large aspect ratio, damping loss factor seems less important to the radiation power. It is also shown that no clear corner and edge mode regions may be found for the guided case, unlike the pinned.

Hybrid radiation technique of frequency-domain Rankine source method for prediction of ship motion at forward speed

  • Oh, Seunghoon;Kim, Booki
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.260-277
    • /
    • 2021
  • The appropriate radiation conditions of ship motion problem with advancing speed in frequency domain are investigated from a theoretical and practical point of view. From extensive numerical experiments that have been conducted for evaluation of the relevant radiation conditions, a hybrid radiation technique is proposed in which the Sommerfeld radiation condition and the free surface damping are mixed. Based on the comparison with the results of the translating and pulsating Green function method, the optimal damping factor of the hybrid radiation technique is selected, and the observed limitations of the proposed hybrid radiation technique are discussed, along with its accuracy obtained from the numerical solutions. Comparative studies of the forward-speed seakeeping prediction methods available confirm that the results of applying the hybrid radiation technique are relatively similar to those obtained from the translating and pulsating Green function method. This confirmation is made in comparisons with the results of solely applying either the free surface damping, or the Sommerfeld radiation condition. By applying the proposed hybrid radiation technique, the wave patterns, hydrodynamic coefficients, and motion responses of the Wigley III hull are finally calculated, and compared with those of model tests. It is found that, in comparison with the model test results, the three-dimensional Rankine source method adopting the proposed hybrid radiation technique is more robust in terms of accuracy and numerical stability, as well as in obtaining the forward speed seakeeping solution.

RADIATION SAFETY ASSESSMENT FOR KN-12 SPENT NUCLEAR FUEL TRANSPORT CASK USING MONTE CARLO SIMULATION

  • Kim, J.K.;Kim, G.H.;Shin, C.H.;Choi, H.S.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.207-214
    • /
    • 2001
  • The KN-12 spent nuclear fuel (SNF) transport cask is designed for transportation of up to 12 assemblies and is in standby status for being licensed in accordance with Korea Atomic Energy Act. To evaluate radiation shielding and criticality safety of the KN-12 cask, each case of study was carried out using MCNP4B Code. MCNP code is verified by performing benchmark calculation for the KSC-4 SNF cask designed in 1989. As a result of radiation safety evaluation for the KN-12 cask, calculated dose rates always satisfied the standards at the cask surface, at 2m from the surface in normal transport condition, and at 1 m from the surface in hypothetical accident condition. Maximum dose rate was always arisen on the side of the cask. For normal transport condition, photons primarily contribute to dose rate between two kinds of released sources, neutrons and photons, from spent nuclear fuel but for hypothetical accident condition, contrary case was resulted. The level of calculated dose rate was 27.8% of the limit at the cask surface, 89.3% at 2 m from the cask surface, and 25.1% at 1 m from the cask surface. For criticality analysis, keff resulting from the criticality analysis considering the condition of optimum partial flooding with fresh water is 0.89708(0.00065. The results confirm the standards recommended by all regulations on radiation safety.

  • PDF

Study on Temperature Load of Curved Steel Box Girder Bridges (곡선강박스거더교의 온도하중에 관한 연구)

  • Kim Sang-Hyo;Cho Kwang-Il;Hong Ju-Hyung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.20-27
    • /
    • 2005
  • Solar radiation causes non-uniform temperature distribution in the structure, depending on the shape of the structure and its shadows. Especially in cases of curved steel box girder bridges, non-uniform temperature distribution due to solar radiation can reduce bridge life and serviceability when combined with another load combination. In this study, the method for predicting the temperature distribution of curved bridges developed by Kim et al., was used to predict the non-uniform temperature distribution which served as a basis for structural analysis of 3-D bridge behavior. In order to seek the most unfavorable conditions of solar radiation, observation data from the Korea Meteorological Administration for solar radiation were analyzed. The region of the most high solar radiation condition was selected and its one year variation of the solar radiation data was considered. From this analysis, the most unfavorable solar radiation condition with lower solar altitude and intense solar radiation was selected. Based on the selected solar radiation condition, structural behavior of curved bridges with diverse bridge direction, span length, radius and support conditions are analyzed.

  • PDF

Soot Formation and Oxidation of an Ethylene Laminar Diffusion Flame with Different Radiation Boundary Conditions (에틸렌 층류 확산화염의 복사경계조건에 따른 매연생성 및 산화특성)

  • Lee, Chun-Beom;Nam, Youn-Woo;Lee, Won-Nam;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.11-18
    • /
    • 2003
  • The soot formation and oxidation characteristics with different radiation boundary conditions have been studied experimentally in a co-flow ethylene/air laminar diffusion flame. The boundary conditions are two cases, one is a fully refractive radiation boundary condition by a polished aluminum cylinder(AL) and the other is a fully absorbing radiation boundary condition by a black body cylinder(BB). The AL case compared with BB condition show the lower inception point, denser soot volume fraction, wider and longer annular soot area owing to the reabsorption of radiating energy.

  • PDF

A Numerical Model of an Edge-clamped Rectangular Plate Based on a Mode Method to Predict Acoustic Radiation Characteristics (모드법에 의한 클램프 조건 사각평판의 음향방사특성 예측모델)

  • Yoo, Ji-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.374-383
    • /
    • 2011
  • A numerical model based on a mode method coupling beams and a rectangular plate is proposed to estimate radiation characteristics of an edge-clamped rectangular plate. The radiation efficiency and radiation power in the audio frequency range including the critical frequency can be predicted. The proposed model is rather simple and straightforward and gives reliable results comparing to the previous studies. The estimated radiation characteristics are compared to those of the pinned condition plates and also to those based on the formulae proposed by Maidanik. The radiation efficiency of the clamped plate seems a little higher than that of the pinned plate in the frequency range of corner and edge modes. It is explicitly shown that the power as well as efficiency at high frequencies is not influenced by these edge boundary conditions.

Development of Oxygen Combustion Burner for Industrial Gasification and Smelting Furnace (산업용 가스화 용융로를 위한 산소 버너의 개발)

  • Bae, Soo-Ho;Lee, Uen-Do;Shin, Hyun-Dong;Kim, Soung-Hyoun;Gu, Jae-Hoi;Yoo, Young-Don
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.170-178
    • /
    • 2005
  • Multi-hole type oxygen combustion burner was developed for industrial gasification and smelting furnace. We investigated characteristics of flame, radiation transfer, and soot emission in the convectional oxygen burner with respect to the feeding condition of fuel and oxygen. Regarding the results of the conventional burner, we designed new burners which have larger fuel consumption rate and radiation heat transfer. We changed the size and hole number and shape of the exit plane of the burner. In addition, the performance of the burner was tested with respect to the feeding condition of the fuel and air: Normal Diffusion flame(NDF) and Inverse Diffusion Flame(IDF). We investigated the flame configuration, radiation heat transfer, and soot formation by using a CCD camera, heat flux meter, and Laser Induced Incadescence(LII), respectively. The stable operating condition was obtained by the flame configuration and the flame of the burner which has dented exit plane was more stable in whole operating conditions. The characteristics of radiative heat transfer were sensitive to the feeding condition of reactants and the flame of 75% primary oxygen and 25% secondary oxygen of the IDF case shows maximum radiation heat transfer. The soot volume fraction of the flame was measured in the axial direction of the flame and the amount of soot volume fraction is proportion to the radiation heat transfer. As a result, we can get the optimal operating condition of the newly designed burner which enhances the characteristics of flame stabilization and radiation heat transfer.

  • PDF

Comparative Study on the Radiation Techniques for the Problem of Floating Body Motion with Forward Speed (전진 속도를 가지는 부유체 운동 문제에 대한 방사기법 비교 연구)

  • Oh, Seunghoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.5
    • /
    • pp.396-409
    • /
    • 2019
  • In this paper, a comparative study on the radiation techniques for the motion analysis of the three dimensional floating structure with the forward speed was carried out. The Sommerfeld radiation condition, the damping technique, and the point shift technique were used for the comparative study. Radiated wave patterns and hydrodynamic coefficients of the heave motion of floating structure with the forward speed were compared and analyzed. The characteristics and limitations of each radiation technique were analyzed through the calculation results. To overcome the limitations of conventional radiation techniques, the hybrid radiation technique combining the Sommerfeld radiation condition with the damping technique was proposed. It is confirmed that the proposed method, the Hybrid radiation technique, improves the limitation of the speed range and the dissipation of the wave of the conventional radiation technique. The motion analysis code of the three dimensional floating structure with the forward speed based on the Rankine source method with hybrid radiation technique was developed. In order to validate the developed code, hydrodynamic analyses were carried and compared with published experiments.

Evaluation of Scatter Radiation in Digital Radiological Condition by using Photostimulated Luminescence (BaFBr:$Eu^{2+}$) (휘진성 형광체 (BaFBr:$Eu^{2+}$)를 이용한 영상의학분야에서 산란선 특성에 관한 평가)

  • Min, Jung-Whan;Han, Seong-Gyu;Kim, Jung-Min;Lee, Joo-Ah;Kim, Ki-Won;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.85-91
    • /
    • 2014
  • The purpose of this study is evaluated scatter radiation in digital radiological condition by using photo-stimulated luminescence (BaFBr:$Eu^{2+}$). Experiment condition changed kVp (from 50 kVp to 120 kVp), filed size (from $4{\times}4cm^2$ to $26{\times}26cm^2$) and phantom thickness (from 1 cm to 15 cm). This method was analysed ImageJ and characteristic curve of CR. This results was scatter radiation to primary radiation ratio increased from 50 kVp to 70 kVp, and it was fixed at over 80 kVp. The scatter radiation to primary radiation ratio are increased according to increasing the ratio of field size. Scatter radiation is also increased by increasing the phantom thickness.

SUGGESTIONS FOR IMPROVMENTS OF THE RADIATION PROTECTION FOR THE EMERGENCY WORKERS DURING THE FUKUSHIMA NUCLEAR POWER PLANT ACCIDENT

  • Khasawneh, Khalid;Cho, Kun-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.103-108
    • /
    • 2014
  • Following the emergency work in Fukushima Daiichi nuclear power plant, more attention was paid for the radiation protection of workers working under severe accident condition. The protection procedure for the emergency workers, including the on-site emergency center, the seismic isolated building and the reestablishment of the radiation protection framework were analyzed to investigate drawbacks and deficiencies which led to adverse effects on the emergency planning and on emergency workers' health and comfort. Those drawbacks were identified and studied, and then suggestions were made to enhance the emergency working condition to avoid any future problems during severe accident emergency work and management.