• Title/Summary/Keyword: Radiating

Search Result 603, Processing Time 0.029 seconds

A Case of Esophageal Perforation due to Foreign Body (식도이물에 의한 식도천공 1예)

  • 홍기환;조규모;송기준
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.7.1-7
    • /
    • 1983
  • Esophageal perforation occurred rarely, but it leads to a high mortality and morbidity. Main cause of esophageal perforation in Korea is instrumental perforation in patients with lye stricture of esophagus during diagnostic endoscopy or therapeutic bouginage. A case of 25-year-old male patient entered to outpatient clinic. Chief complaints were mild pain at swallowing, mild fever elevation and chest tightness with radiating pain to shoulder and interscapular region for 1 day. On the X-ray film with barium soaked cotton piece in esophagus, it was revealed that foreign body (fish bone) had been located on the level of 2nd vertebra with leakage of barium to mediastinum. The foreign body was removed with endoscopy in Dept. of otolaryngology, and cervical mediastinostomy was performed in Dept. of thoracic surgery.

  • PDF

Radiation Technology in the Preparation of Polyethylene Oxide Hydrophilic Gels and Immobilization of Proteases for Use in Medical Practice

  • E.I.Vereschagin;Han, Do-Hung;A.W.Troitsky;O.V.Grishin;S.E.Petrov;E.P.Gulyaeva;L.A.Bogdanova;M.V.Korobeinikov;V.L.Auslender
    • Archives of Pharmacal Research
    • /
    • v.24 no.3
    • /
    • pp.229-233
    • /
    • 2001
  • This Paper deals with the development of a technology for making a hydrophilic gel of Polyethylene oxide reception in which radiating ability is employed to cause cross-linking of Polymers in a water solution. The gel of polyethylene oxide was shown to be nontoxic contain 5-50% of polymer and be useful in composite medicinal forms along with biologically active substances including Bac. subtilis proteases. Proteases immobilized in the gel possess high thermal stability and proteolytic activity and are readily applied in medicine. The effect of immobilized proteolytic and glucolytic enzymes of Bac. subtillis (Immozimase) on the warm ischemia-reperfusion (I/R) which can cause hepatic and jejunum injury was also studied. These enzymes were immobilized on water-soluble polymer polyethylene glycol by means of an electron beam. The number of degraanulated mast cells as well as serum ALT after I/R in the group with Immozimase was decreased to almost half as compared with the control group. Pretreatment with Immozimase resulted in significant reduction of hepatic and gut neutrophil accumulation as compared with control animals. It was concluded that Immozimase has a protective effect for hepatic and gut ischemia/reperfusion, and this effect seems to be associated with prevention of leukocyte accumulation .

  • PDF

K-Band Radar Development for the Ground Moving Vehicle (지상 이동 차량용 K-대역 레이다 개발)

  • Lee, Jong-Min;Cho, Byung-Lae;Sun, Sun-Gu;Lee, Jung-Soo;Park, Sang-Soon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.362-370
    • /
    • 2011
  • This paper presents a K-band radar system installed on the ground moving vehicle to detect and track a high-speed target. The presented radar is separated into three search regions to satisfy a wide area detection and a limitation of the installing space of the radar, and each region performs detecting the target independently and tracking the detected target automatically. The presented radar radiating K-band FMCW waveform acquires range and velocity information of the target at the every dwell and receiving antenna of the radar is applied the multiple baseline interferometer to extract the precise angle information of the target. 3-dimensional tracking accuracy of the radar is 0.25 m RMSE measured actually through a fire experiment of an imitation target.

Analysis on the RFI Noise Path of Electrical Railway System in the Frequency Range of 9 kHz to 150 kHz (전기철도 시스템의 9~150 kHz 대역에서의 RFI 노이즈 전달 경로 분석)

  • Kwun, Suk-Tai;Chung, Yeon-Choon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.12
    • /
    • pp.1373-1379
    • /
    • 2012
  • The interaction of magnetic field in the frequency range of 9~150 kHz radiating from a railway system with wireless systems has been the cause of radio frequency interference. In this paper, the equivalent circuit model of the RFI noise is proposed through source and transfer path analysis, and it is confirmed that the switching noise of several kHz that occurs a vehicle traction drive system and a substation is radiated by forming the loop circuit with a feeder line by a rolling stock. And the validity of the proposed equivalent circuit model is verified by analyzing the effects of RC banks installed in the real railway between Guri and Guksu stations, the RFI noise can be effectively mitigated by loading suitable capacitance between rail and feeding line.

A Reconfigurable Antenna for Quad-Band Mobile Handset Application (4중 대역을 포함하는 휴대폰용 재구성 안테나)

  • Park, Young-Keun;Sung, Young-Je
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.5
    • /
    • pp.570-582
    • /
    • 2012
  • In the communication, a reconfigurable antenna using two PIN diodes is presented for quad-band(GSM900/GSM1800/GSM1900/UMTS) mobile handset applications. The proposed antenna has a size $45{\times}11{\times}6mm^3$. By independently adjusting the on/off states of two PIN diodes located on the radiating element, the proposed structure can be operated in the PIFA and loop mode, respectively. The PIN diodes are replaced by conducting tape in order to verify the concept. In regards to the fabricated reconfigurable antenna, when operating in the PIFA mode, the measured results show that the 7 dB bandwidth is 8.62 %. which covers the GSM900(880~960 MHz) band. When operating in the loop mode, the measured results show that the 7 dB bandwidth is 26.36 %, which covers the GSM1800(1,710~1,880 MHz), GSM1900(1,850~1,990 MHz), and UMTS(1,920~2,170 MHz) bands, respectively.

Circularly Polarized Antenna with Wide Axial-Ratio Bandwidth (광대역 축비 특성의 원형 편파 안테나)

  • Lee, Kwang-Jae;Woo, Duk-Jae;Lee, Taek-Kyung;Lee, Jae-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.842-849
    • /
    • 2010
  • This paper deals with a TT&C circularly polarized turnstile antenna for LEO satellites. The turnstile antenna consists of radiator for radiating power to free-space and power divider for generating circularly polarized wave. we presents a radiator to tolerate in space environments and a power divider to provide flat phase difference at wide bandwidth. The bandwidth of the proposed antenna covers the frequency bands of up- and down-link. The antenna shows wide beamwidth and enhanced axial ratio for unfavorable space environments.

Design and Fabrication of Dual-Ring Monopole Antenna for Wideband Characteristics (광대역 특성을 갖는 이중 원형 링 모노폴 안테나의 설계와 제작)

  • Yoon, Joong-Han;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.9
    • /
    • pp.1285-1291
    • /
    • 2013
  • In this paper, a double circular ring monopole antenna for wideband applications is designed and fabricated. The proposed antenna is based on a planar monopole design, and composed of double circular ring of radiating patches and ground plane to obtain the wideband characteristics. To get the optimized parameters, we used the simulator, Ansoft's High Frequency Structure Simulator(HFSS) and found the parameters that effect antenna characteristics. Using the obtained parameters, the proposed antenna is fabricated. The fabricated antenna is measured at the operating frequencies, and the return loss coefficient, gain, and radiation patterns are determined. The results of measurement, -10dB impedance bandwidth, measured return loss is 4,530 MHz(2,510-7,040 MHz) and antenna peak and average gains for the frequencies are obtained 0.71~3.38 dBi, -3.85~0.3 dBi, respectively. In case of radiation patterns, the proposed antenna displays nearly omnidirectional radiation characteristics in the E-plane, and monopole-like radiation pattern characteristics in the H-plane.

A Study on the Design and Implement of The Function of the Sidelobe Blanking of VHF Radar (초단파 레이다의 부엽 차단 기능에 대한 설계 및 구현에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.4
    • /
    • pp.637-642
    • /
    • 2020
  • In this study, the SLB(Sidelobe Blanking)/BLB(Blacklobe Blanking) design of the VHF band radar using the low-frequency band having a relatively larger beam width than the S-band or X-band radar. The antenna of the VHF band has a relatively large beam width, so it is reflected from the side lobe. If the reflected target signal is not processed into sidelobe, the false alarm rate of the radar increases by recognizing it from the main lobe signal. This method of SLB blocking is the elimination of the side lobe signal in the front of the array antenna using the central radiating element of the array antenna, and the blocking of side lobe signal from the antenna rear through BLB receiver block. After completed the radar implementation, The function of blocking of side lobe signals was confirmed through the system unit test by Simulated signal generator. Through this study, it will be used in the implementation of the side-lobe blocking technology of the array antenna for low-frequency band radar with large antenna size and beam width in the future.

The Clinical Study on Acupuncture Sensation in CC, CF and BV Herbal Acupuncture -The Basic Study on Placebo Herbal Acupuncture- (CC, CF, BV 약침의 침감에 대한 임상적 연구 -placebo 약침을 위한 기초연구-)

  • Seo, Jung-Chul;Yoon, Jong-Seok;Han, Sang-Won;Park, Hi-Joon;Lee, Hye-Jung
    • Journal of Pharmacopuncture
    • /
    • v.7 no.1 s.12
    • /
    • pp.63-69
    • /
    • 2004
  • Objective : This study was designed to find out whether NS(normal saline) is able to be constituted as an appropriate control group for CC(Cervi Cornu Parvum herbal acupuncture), CF(Carthami-Flos herbal acupuncture) and BV(bee venom herbal acupuncture). Method : NS and three herbal acupuncture were inserted into Quchi(LI 11) of the subjects. After 5 minutes the subjects completed a questionnaire rating the intensity of 21 kinds of acupuncture sensation; hurting, penetrating, sharp, aching, intense, spreading, radiating, tingling, pricking, stinging, pulling, heavy, dull, numb, electric, shocking, hot, burning, cool, pulsing, and throbbing. We compared subjective evaluations of acupuncture sensation between or among the groups. Results : As for CC half items of the acupuncture sensation were significantly different from NS. As for CF all items were not significantly different from NS. As for CC all items were significantly different from NS except one item. In general the score of CF acupuncture sensation was lower than the others and the score of BV acupuncture sensation was higher than the others from comparison of sensation among herbal acupunctures(CC, CF, BV). Conclusion : We found that NS is able to be an appropriate placebo herbal acupuncture for CF. Further study is needed for new placebo herbal acupuncture for CC and BV.

The Effect of Three 20 mg Caudal Epidural Injections of Triamcinolon on the Blood Glucose, ACTH and Cortisol Concentrations in the Elderly Women (노인에서 경막외강에 3회 분할 투여된 Triamcinolone 60 mg이 혈중 포도당, ACTH와 Cortisol에 미치는 영향)

  • Goh, Jee Eun;Min, Soon;Jeong, Young Ju;Lee, Heon Keun
    • The Korean Journal of Pain
    • /
    • v.18 no.1
    • /
    • pp.15-18
    • /
    • 2005
  • Background: Epidural steroid injections (ESI) have been used widely for the treatment of back and radiating extremity pain. Although its effects on the metabolic and endocrine system have been studied, the effects following repeated injections remain to be determined. We studied the effects of three repeated caudal epidural injections of low dose triamcinolone. Methods: the subject were 10 elderly women with spinal stenosis. Caudal epidural injections were performed biweekly. Triamcinolone (20 mg), mixed with 15 ml of 0.25% lidocaine, was used as the ESI injectate. The procedures were performed with the patient in the prone position. Blood sampling was performed just before the first injection, and used as the baseline, and then just before each injection on the same day of the 2nd and 4th weeks, with the last samples taken 2 weeks after the third injection. Results: The blood glucose concentrations showed no significant changes. The blood cortisol and ACTH concentrations were significantly decreased after the first injection, but there were no further decreases after each of the subsequent injections. The cortisol concentrations were maintained within the normal range. Conclusion: Caudal epidural injections, with low dose triamcinolone, suppressed the hypothalamus-pituitary-adrenal (HPA) axis, but no further suppression followed the subsequent repeated injections. Three consecutive caudal injections at 2 week intervals seems to be a safe procedure.