• 제목/요약/키워드: Radiant Energy

검색결과 191건 처리시간 0.021초

차폐막이 있는 밀폐공간 내에서의 난류 자연대류 - 복사열전달에 관한 연구 (A Study on the Turbulent Natural Convection - Radiative Heat Transfer In a Partitioned Enclosure)

  • 박경우;이주형;박희용
    • 대한기계학회논문집
    • /
    • 제18권10호
    • /
    • pp.2738-2750
    • /
    • 1994
  • The Effects of radiative heat transfer on turbulent flow in a partitioned enclosure is studied numerically. The enclosure is partially divided by a thin, poorly conducting vertical divider projecting from the ceiling of the enclosure. The low Reynolds number $k-{\epsilon}$ model is adopted to calculate the turbulent flow field. The solutions to the radiative transfer equations are obtained by the discrete ordinates method(DOM). This method is based on control volume method and is compatible with the SIMPLER algorithm used to solve the momentum and energy equations. The effects of optical thickness and Planck number on the flow, temperature fields and heat transfer rates are investigated for a moderate Rayleigh number($=10^9$). The changes in buoyant flow fields and temperature distributions due to the variation of baffle length are also analyzed. From the predictions, radiant heat exchange between the baffle and the sidewalls strongly influences the temperature distribution in the baffle and its vicinity and total heat transfer increases as the optical thickness and the baffle length decrease. It is possible to neglect the radiative heat transfer effect when Planck number is over one.

정사각형 밀폐공간내에서의 자연대류와 표면복사의 수치해석 (Numerical Analysis of Natural Convection and Surface Radiation in a Square Enclosure)

  • 권용일;권순석
    • 대한기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.983-991
    • /
    • 1992
  • 본 연구에서는 정사각형 밀폐공간에서 밑면과 윗면이 각각 고온과 저온부이고 좌측, 우측면일부가 단열이며 우측면 일부는 저온부인 온돌공간으로 가정하였다. 일 사에너지가 우측면 저온부(창)으로 통과된 경우와 통과되지 않는 경우의 표면복사와 자연대류에 관하여 연구하였다.그리고 창에서 일사 에너지가 존재하는 표면복사의 경우는 표면복사와 구별하기 위하여 일사복사로 취급하였다. 표면복사 열전달을 해 석하기 위해서는 Hottel에 의해 고안된후 보안 발전된 정미복사방법(net radiation method)을 이용하여 벽면에서의 정미 복사량을 구하였으며 형상계수(shape factor)를 구하기 위하여 교차선방법(crossed string method)을 이용하였다.

Study on Integrated Workflow for Designing Sustainable Tall Building - With Parametric method using Rhino Grasshopper and DIVA for Daylight Optimization

  • Kim, Hyeong-ill
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.21-28
    • /
    • 2016
  • Purpose: The Objective of this study is to explore the capabilities of an integrated modelling and simulation workflow when applied to an experiment-based research process, aimed at deriving daylight optimization strategies specific to tall buildings. Methods: Two methods were devised to apply this workflow with the help of DIVA and Rhino/Grasshopper. The first method is a multiple variant analysis by setting up an appropriate base case and analysing its daylight and energy performance, forming the basis of comparison for subsequent cases for design variants. The second method involved setting up the base case within a site context and conducting a solar irradiation study. An architectural variables such as overhang and shading device, were then defined as inputs in the parametric definition in Grasshopper to control the selected variable. Results: While the first method took advantage of the speed and efficiency of the integrated workflow, the second method was derived based on the ability to directly process simulation data within the integrated, single-software platform of the proposed workflow. Through these methods, different architectural strategies were explored, both to increase daylight penetration and to reduce radiant heat gain. The focus is on methods by which this workflow can be applied to facilitate the experimental derivation of daylight optimization strategies that are specific to tall building design.

장파복사 모형의 매개변수 추정 (Parameters Estimation in Longwave Radiation Formula)

  • 조홍연;이길하;이정미
    • 환경영향평가
    • /
    • 제21권2호
    • /
    • pp.239-246
    • /
    • 2012
  • Daily net radiation is essential for heat budget analysis for environmental impact assessment in the coastal zone and longwave radiation is an important element of net radiation because there is a significant exchange of radiant energy between the earth's surface and the atmosphere in the form of radiation at longer wavelengths. However, radiation data is not commonly available, and there has been no direct measurement for most areas where coastal environmental impact assessment is usually most needed. Often an empirical equation, e.g., Penman and FAO-24 formulae is used to estimate longwave radiation using temperature, humidity, and sunshine hour data but local calibration may be needed. In this study, local recalibration was performed to have best fit from a widely used longwave equation using the measured longwave radiation data in Korea Global Atmospheric Watch Center (KGAWC). The results shows recalibration can provided better performance AE=0.23($W/m^2$) and RMSE=14.73($W/m^2$). This study will contribute to improve the accuracy of the heat budget analysis in the coastal area.

하절기 도시의 장.단파 복사특성 관측 (Study on Characteristics of Radiation Environment in the Urban through the Field Observation in the Summer)

  • 정임수;최동호;이부용
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.105-110
    • /
    • 2011
  • The objective of this study is to analyze the characteristic of radiation environment in the urban and rural through the field observation in the summer. The radiation balance was compared through the measurement of the shortwave radiation and long-wave radiation in the urban, sub-urban, and rural. The following conclusion could be obtained from this research. (1) In the results of observation including the rain-day, it was found that the short wave radiance in the urban is lower about 10% than the rural. (2) The upper part of atmosphere layers in the urban area absorb much short wave radiation energies compared with the rural relatively. It can increase the temperature of the upper part of atmosphere layers and the emittance of long wave radiation. (3) The ratio of the downward short wave radiation to the downward long wave radiation was 1.24 for the urban, 1.28 for sub-urban and1.35 for rural. It can be estimated that the atmosphere condition of the rural is better than that of other areas.

  • PDF

옥외광고용 발광조명의 야간휘도분포 분석 (Luminance Assessment of Outdoor Lighting for Advertisements at Night)

  • 신화영;이종수;김정태
    • KIEAE Journal
    • /
    • 제9권6호
    • /
    • pp.65-72
    • /
    • 2009
  • Lighting for outdoor advertising is very common feature of building facades as they provide the information and commercial identification. As the interest of improving street beautification more widely, application of various lighting technologies has been develop for advertisement such as electric sign board and signage. Furthermore, the installation of higher sign luminance than needed has many negative consequences, including higher energy consumption and light pollution. There are now no standard for outdoor advertisements in terms of luminance, and installation of indiscreet outdoor advertisement without luminance consideration is becoming more commonplace. This study was to evaluate the luminous characteristics of outdoor advertising as a function of sign and building facade luminance, luminance ratio. Data were collected on 8 electric sign boards, 20 internally illuminated, externally illuminated, neon, and channel letter signs and 4 commercial areas. Photometric measurements were taken by CS-100(Minolta) and ProMetric-1400(Radiant Imaging) for various sign modes and sign design. Also luminance of building facades were analyzed according with CIE standard of maximum obtrusive light permitted for exterior lighting installations. The findings are as follows; (1) There were excessive luminance of electric sign boards that could affect adjacent building facade and night sky luminance. (2) Sings that are externally illuminated providing an inappropriate amount of light on to the outer surface of the sign caused higher building facade luminance and potential of unnecessary glare.

초고층 공동주택 외기전담 시스템 기반 중앙 공급식 환기시스템의 적정 급기조건 설정 (Acceptable Supply Air Conditions of Dedicated Outdoor Air System for a High-rise Apartment Building)

  • 김민휘;김진효;권오현;정재원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.285-290
    • /
    • 2009
  • The main thrust of this paper is to investigate acceptable supply air conditions of a dedicated outdoor air system (DOAS) for highrise apartment buildings. As for a typical $132-m^2$ apartment unit, it was assumed that centralized DOAS-Ceiling Radiant Cooling Panel was installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program. The optimized dew point temperature of the DOAS was discussed on the basis of the ASHRAE standard 62.1-2007 and the current Korean ventilation standard for apartments. It was found that the optimized dew point temperature of the DOAS supply air accommodating total latent load of a space is $11-12^{\circ}C$ and the appropriate supply air temperature of the DOAS is $11-12^{\circ}C$ in cooling period and neutral temperature of $18-20^{\circ}C$ in intermediate period.

  • PDF

날아가는 섬광탄이 연료탱크 수평핀에 미치는 복사열전달 연구 (An Investigation of Radiation Heat Transfer on The Horizontal Fin of An External Fuel Tank by Flame of a Flying Flare)

  • 정대한;강치행;김시태
    • 한국군사과학기술학회지
    • /
    • 제17권2호
    • /
    • pp.197-203
    • /
    • 2014
  • In this paper, the effect of unsteady radiation on the horizontal fin of an external fuel tank by flame of a flying flare was analysed to see the temperature increase of the fin and the thermal impact on the fin. Radiation between two surfaces was calculated using the concept of radiation resistance of surface and space including radiation, irradiation and shape factor for two flying trajectories of a flare, maximum temperature of 2200 K, emissivity of 0.95, flying velocity of 30 m/s, and thermal surface area of $0.01m^2$. The result shows that the temperature increase of the fin is 0.236 K, and the thermal effect on the fin is ignorable. And it was found that temperature is increased a little because small amount of heat energy can be radiated due to the short exposure time to the heat source.

복사에너지를 이용한 TIM소재의 방열 특성 향상을 위한 연구 (Study on Improvement of Heat Dissipation Characteristics of TIM Material Using Radiant Energy)

  • 황명원;김도형;정우창;정원섭
    • 한국표면공학회지
    • /
    • 제52권2호
    • /
    • pp.58-61
    • /
    • 2019
  • The aim of this study is to quantitatively demonstrate the possibility of heat transfer by thermal radiation by comparing heat transfer by conventional heat transfer and radiation by radiation. 1) The heat transfer was measured by using filler of TIM material with low thermal conductivity (CuS). As a result, heat transfer was easier than ceramic with high thermal conductivity ($Al_2O_3$ and $Si_3N_4$). 2) The reason for this is thought to be that the infrared wave due to radiation of the air diaphragm has moved easily. 3) From the above results, the heat dissipation of the TIM material indicates the possibility of heat transfer by thermal radiation.

미디어파사드 상영 시 경천사지 십층석탑에 미치는 영향 조사 연구 (A Study on the Impact of Media Façade Performances on the 10-story Gyeongcheonsa Pagoda)

  • 이홍식;유재형;이권준;양석진
    • 박물관보존과학
    • /
    • 제28권
    • /
    • pp.51-64
    • /
    • 2022
  • 본 연구는 문화재를 대상으로 관람객에게 보다 관심을 유도할 수 있는 증강현실(AR)이나 미디어파사드 공연 시 문화재에 조사되는 광학 에너지에 의해 문화재에 어떠한 영향을 주는지 알아보기 위한 연구를 실시하였다. 문화재는 경천사지 십층석탑을 대상으로 하였으며 평상 시 조사되는 광에너지를 기준으로 미디어파사드 공연 시 조사되는 광에너지의 값을 가지고 그 영향성을 판단하였다. 비교를 위해서 경천사지 십층석탑에 조사되는 광원 별 조도(lx)값을 측정하였고 이 값을 활용하여 적산조도값(lx·h)을 통해 그 영향성을 비교하였다. 그 결과 태양광과 인공광원이 동시에 존재하는 경우 경천사지 십층석탑이 받는 시간 당 적산조도는 786.4 lx·h 이며, 1회 상영 시 미디어파사드에 의해서는 13.2 lx·h의 에너지가 입사됨을 확인하였다. 이 결과는 한 시간 기준으로 미디어파사드 공연 시(주 2회 기준) 경천사지 십층석탑이 받는 광 에너지보다 태양광과 인공광원에 의한 광에너지가 약 29.8배 높음이 확인되었고 이에 미디어 파사드 공연에 의한 경천사지 십층석탑이 광 에너지에 의한 손상은 미미한 수준일 것이라는 결론을 얻었다.