• 제목/요약/키워드: Radiant Energy

검색결과 189건 처리시간 0.033초

시설하우스의 폐열을 이용한 열펌프시스템의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Heat Pump System Using Waste Heat in Greenhouse)

  • 조기현;박윤철;고광수
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.35-41
    • /
    • 2015
  • This study was conducted to develop a heat pump system to utilize waste heat within the greenhouse during the daytime in winter season. The system runs at 8 am to 6 pm for the heat storage operation, and from 6 pm to 8 am of the next day for the heat radiant work. In the case of the heat storage operation, the average solar radiation was $168.3W/m^2$ with $16.3^{\circ}C$ outside temperature. The $COP_s$ of the system shows 4.59 in this operation mode. When the temperature goes up to $18.6^{\circ}C$, the system $COP_s$ reached at 5.10. On the other hand, the $COP_h$ of the system in heat radiation mode shows 2.63. In this case, the inside of the greenhouse temperature was reaches at $24.7^{\circ}C$ when the outside temperature was $12.9^{\circ}C$.

하절기 복사환경 관측을 통한 수목과 일사차폐 막 구조물의 자연냉각효과 (Analysis of Passive Cooling Effect of Membrane Shading Structure and the Tree by Field Observations in the Summer)

  • 최동호;이부용
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.137-146
    • /
    • 2007
  • This study is about the passive cooling effects of three outdoor solar shading facilities as trees, pergola with wistaria vine and membrane shading structure, which are expected to provide cool spots in the summer. Field observations of measuring thermal environment of selected facilities is executed. Thermal environment measuring was categorized as short wave radiation, long wave radiation, net radiation, globe temperature, surface temperature measured by infrared camera. Heat transfer mechanism is analyzed with overall data from field measurement. Results from this study are as below; 1) Radiation balance measured on shaded surface under membrane shading structure was 17%($86W/m^2$) of the unshaded surface radiation balance($511W/m^2$). 2) Surface temperature comparison between vegetation and membrane of the shading structure is performed at 3 o'clock in the afternoon. Surface temperature of vegetation was same as air temperature and that of membrane was $5^{\circ}C$ higher than air temperature. Vegetation transpiration is considered as the causing factor which make those differences. 3) Results from this study could be used as fundamental data for reducing heat island phenomena and continuos research on this subject would be needed.

Mock-up실험에 의한 바닥복사 냉방시스템의 온도특성에 관한 연구 (A Study on the Temperature Characteristics of the Floor Cooling System of Mock-up Experimentent)

  • 유호천;이영아
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.48-57
    • /
    • 2008
  • The research analyzed the distribution of the indoor temperatures of a radiant floor cooling system through mock-up experiments. It investigated the temperature difference of feed water, the vertical temperature difference of indoor air, the temperature difference of floor surface, and so on. The following is the results of the research. First, the research shows that the difference between indoor temperature and outside temperature was the smallest when the temperature of feed water was set at 16$^{\circ}C$. In addition, the temperature changes according to indoor positions (wall, room, floor, and ceiling) were the most uniform. Thus, the research found that the cold water temperature of 16$^{\circ}C$ is the most proper. In addition, it confirmed that the feed water temperature of 18$^{\circ}C$ is effective because the temperature can lower the temperature of a room to 13.55$^{\circ}C$, which is lower than the temperature of a non-cooling mode. Second, an investigation on the temperature distribution of vertical air in indoor space shows that the temperature distribution had a difference of 0.2 to 1.9$^{\circ}C$ on the average, which satisfies the range of 3.0$^{\circ}C$ in the standard of ISO.

A Sensitivity Analysis of Accuracy for COMS Outgoing Longwave Radiation Product

  • Kim, Hyunji;Han, Kyung-Soo;Lee, Chang Suk;Shin, Inchul
    • 대한원격탐사학회지
    • /
    • 제31권1호
    • /
    • pp.39-46
    • /
    • 2015
  • Outgoing Longwave Radiation (OLR) is emitted energy from the Earth that is an important indicator of cooling effect in global scale and meteorological events in regional scale. Satellite-driven OLR products have its advantages overcoming spatially limited representation. The Korean geostationary satellite, Communication, Ocean and Meteorological Satellite (COMS), has been producing OLR product in accordance with its own algorithm since Apr. 2011. This study introduces Spatio-Temporally Equalized Match-up (STEM) approach to evaluate the COMS OLR products. We have tested a number of cases of thresholds set by standard deviations of a subpixel $10.8{\mu}m$ to find optimal representation of OLR in the selective match-up. Each case was then validated with broadband reference data, Clouds and the Earth's Radiant Energy System (CERES). We found that selective STEM approach was useful to validate OLR product especially its distribution in homogeneous grids.

SOFC용 고온 적층 단열재의 해석적 고찰 (An Analysis Using Numerical Model of Composite Multi-Layer Insulation for SOFC)

  • 최종균;황승식;최규홍
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.540-548
    • /
    • 2019
  • This study was conducted to develop insulation for solid oxide fuel cell (SOFC). The developed insulation is based on the lamination technology and the radiation shielding technology of the satellite insulation. The insulation material is consisting of insulation material for conduction resistance, spacer, and radiation shielding material. The experimental apparatus consisting vacuum bell jar, pump, heater and temperature recording device has developed to verify the performance of the insulation. The experimental values were used as reference data for the modeling development. In this paper, heat transfer is assumed to be one- dimensional phenomena for the prediction of insulation performance and internal temperature distribution in high temperature region of SOFC. The developed model was used to compare the performance difference of insulation types according to composition materials. The analysis result shows that the insulation including spacer and radiation shielding has better heat insulation performance than other cases. In this study, the thickness reduction effect of about 20% was shown compared to the insulation including only conductive material. It is noted that the radiant shielding material should be carefully selected for durability, because SOFC insulation should be used for a long time at high temperature.

원적외선 가열에 의한 농산물의 건조특성 (Drying Characteristics by Infrared Heating of agricultural products)

  • 상희선;배내경
    • 한국산업융합학회 논문집
    • /
    • 제8권1호
    • /
    • pp.47-55
    • /
    • 2005
  • Infrared heating has been traditionally used in industrial applications for processes such as dehydration of food industrial. This heating method involves the application of radiation in the wavelength range of 2 to 50 micrometers. In this work, simultaneous heat balance equations were developed to simulate the infrared radiation heating of agricultural products. The equations assume that moisture diffuses to the outer boundaries of the material in liquid form and evaporation occurs at the surface of the agricultural products. Energy for moisture evaporation is supplied by the infrared radiant energy. The optimum temperature and drying time for the best drying conditions of changing the red peppers with the moisture content of 18% and the restore rate of 80~85% are $80^{\circ}C$ and 44 hours. The performance of radiation tubes coating with the radiation paint developed in this research has the energy of $2.27{\times}103W/m^2{\mu}m$, $150^{\circ}C$ within the scope of radiation wave length of $2{\sim}30{\mu}m$ and has the radiation 0.92~0.93, which is superior to the general radiation tubes. The extinction coefficient according to the band pass filter using the 4 flux theory ha higher dependability on wave length, accounting for $2{\sim}17{\mu}m$ and $5{\times}105{\sim}106m-1$. A comparison between the theoretical energy transfer whose figures are interpreted according to 4 flux theory and the experimental energy transfer of far infrared dryer leads to the findings of the agreement less than 5%.

  • PDF

매트 형태 연소촉매를 사용하는 촉매버너의 구조와 연소특성 (Combustion Characteristics and Design of Fiber Mat Catalytic Burners)

  • 송광섭;정남조;김희연
    • 에너지공학
    • /
    • 제17권2호
    • /
    • pp.100-106
    • /
    • 2008
  • 매트형태의 연소촉매를 사용하는 촉매연소 버너는 발생 열을 원적외선 형태로 피 가열체에 공급할 수 있기 때문에 저온 공정에서 효율적으로 열을 사용할 수 있다. 매트형태 촉매연소 버너의 활용 가능성을 높이기 위해 촉매연소버너를 제작하고 구조에 따른 연소성능에 대해 고찰하였다. 확산식 촉매연소에서는 연소면의 방향이 연소반응에 많은 영향을 주며, 촉매 주위 온도변화에 따른 산소의 확산속도 차이가 촉매 연소 반응 속도에 많은 영향을 주는 것을 알았다. 예혼합 촉매연소에서 연소공기는 이론공기량 보다 조금 많게 공급하는 것이 최적이고, 연소열의 70% 이상이 복사로 전달됨을 알았다.

온실내 잉여 태양에너지 산정 (I) - 1-2W형을 중심으로 - (Estimation of Surplus Solar Energy in Greenhouse (I) - Case Study Based on 1-2W Type -)

  • 서원명;배용한;유영선;이성현;윤용철
    • 한국농공학회논문집
    • /
    • 제51권5호
    • /
    • pp.79-86
    • /
    • 2009
  • This research performed to analyze surplus solar energy, which is generated from a greenhouse during daytime, and to make the basic materials for designing thermal energy storage system for surplus solar energy. For this goal, it analyzed the surplus solar energy coming from two types of greenhouse. The results of this research are as per the below: In the case of 1-2W-type greenhouse, this research gave the same temperature and ventilation condition regardless of regions, but it was judged that the quantity of surplus solar energy could be greatly changed, depending on the energy consumed for the photosynthesis and evapotranspiration of crops in the greenhouse, on the heating temperature during daytime and night, on the existence/non-existence of a curtain and its warming effect, and on the ventilation temperature suitable for the overcoming of high temperature troubles or for the optimum cultivation temperature. In the case of a single-span greenhouse, there was a big difference in energy incoming and outgoing by month, but throughout seasons, 85.0 % of the total energy put into the greenhouse was solar energy and the energy input by heating was just 15.0 % of the total. 26.4 % of the total energy input for the greenhouse was used for photosynthesis and evapotranspiration of crops, and 44.2 % of the remaining 73.6 % went out in the form of radiant heat through the surface of the greenhouse. That is, 25.2 % of the total energy loss was just the surplus solar energy. 67.6 % of the total heating energy was concentrically used for 3 months from December to February next year, but the surplus solar energy during the same period was just 19.4 % of the total annual quantity so it was found that the given condition was more restrictive in directly converting the surplus heat into greenhouse heating. Under the disadvantageous circumstance of 3 months from December to February next year, it was possible to supplement 28 % (December) $\sim$ 85 % (February) of heating energy with surplus solar energy.

구름과 에어로솔의 혼재시 에어로솔의 광학특성이 상향 단파 복사에 미치는 영향 (Effects of Aerosol Optical Properties on Upward Shortwave Flux in the Presence of Aerosol and Cloud layers)

  • 이권호
    • 대한원격탐사학회지
    • /
    • 제33권3호
    • /
    • pp.301-311
    • /
    • 2017
  • 에어로솔의 광학특성과 연직고도는 태양 복사의 반사와 흡수과정을 통하여 지구복사수지에 영향을 미치게 된다. 본 연구에서는 복사전달모델과 위성관측자료를 이용하여 동북아시아 지역에서 구름의 존재 시 에어로솔 층에 의한 복사특성을 분석하였다. 복사전달 모의 결과는 구름이 하부에 존재하는 경우에 에어로솔 층의 고도가 높아짐에 따라 대기 온난화 효과가 증가하였다. 이러한 관계는 에어로솔의 광 흡수성이 커질수록, 지표 반사도가 증가할수록 비례하는 경향을 나타내었다. 그리고 연구대상지역 ($20-50^{\circ}N$, $110-140^{\circ}E$)에서 주요 에어로솔 이벤트 사례에 대하여, UV Absorbing Aerosol Index (AAI) derived from Total Ozone Mapping Spectrometer (TOMS), cloud parameters derived from the Moderate Resolution Imaging Spectro-radiometer (MODIS), with Upward Shortwave Flux (USF) Clouds and the Earth's Radiant Energy System (CERES) 위성관측자료를 이용하여 광 흡수성 에어로솔에 의한 영향을 정량적으로 분석하였다. 각 사례에 대한 평균적인 복사효과는 약 6 - 26 %에 해당하는 상향 단파 복사량의 감쇄효과가 나타났다. 이러한 결과는 에어로솔에 의한 직접효과와 간접효과를 정량화 하기 위한 중요성을 설명해 준다.

고밀도 주거지역에서의 복사플럭스 영향 연구 - 서울시 중랑구 지역을 대상으로 - (Radiation Flux Impact in High Density Residential Areas - A Case Study from Jungnang area, Seoul -)

  • 이채연;권혁기;프레드릭 린드버그
    • 한국지리정보학회지
    • /
    • 제21권4호
    • /
    • pp.26-49
    • /
    • 2018
  • 본 연구는 도시지역을 대상으로 태양복사모델링을 수행하고 검증하여, 도시 내 열스트레스 완화에 대한 적용 가능성을 논의하였다. 이를 위해 연구지역은 항공 LiDAR 자료를 기반으로 실제 건물과 식생의 형태와 높이가 구현되었고, 보행자높이에서의 단파 및 장파복사 플럭스가 모의될 수 있도록 해상도를 향상시켰다. 고층 및 저층 건물이 고밀도로 존재하는 주거지역 $4km^2$에서 SOLWEIG 모델을 이용하여 복사플럭스를 모의하고, 지표에너지수지시스템의 Net radiometer를 이용한 복사플럭스 관측자료로 검증하였다. 그 결과 여름철 맑은 날 가장 높은 정확도를 나타냈고, 같은 날에 대한 평균복사온도를 모의한 결과, 그림자영향이 적은 저층 건물지역과 도로표면에서 가장 높은 수치를 나타냈으며, 고층 건물지역과 식생지역에서는 그림자의 영향으로 상대적으로 낮은 수치를 나타냈다. 본 연구에서 제안된 방법은 보행자높이에서 도시 내 열스트레스 지역 관리를 위한 높은 신뢰도를 보여주었다. 더욱 확장되고 있는 도시재생 및 재개발에 있어서, 새로운 주거환경을 도입하기 위해 도시 기반시설을 계획할 때 자연 및 인공 도시환경 설정과 관련된 많은 기능이 적용될 수 있다.