• 제목/요약/키워드: Rabbit tibia

검색결과 47건 처리시간 0.023초

가토 경골에 식립된 Ca-P 박막코팅 임프란트의 뒤틀림 제거력 및 조직형태학적 평가 (THE EVALUATION OF THE REMOVAL TORQUE AND THE HISTOMORPHOMETRY OF THE CA-P COATING SURFACE IN RABBIT TIBIA)

  • 곽명배;이청희
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.556-571
    • /
    • 2004
  • Statement of problem: Surface texture of the implant is one of the important factors of the implant success, especially in the immediate implant loading. Many methods of the surface treatment of implant have developed and introduced. Purpose : This study was to evaluate the effects of the Ca-P coating implant crystallized the hydroxyapatite on the surface by the removal torque test and the histomorphometric analysis in vivo. Material and methods: 135 screw type implants, 4.0mm in length and 3.75mm in diameter were used in this study. Implants were divided into 3 groups and treated in the different mothods. Group I was not treated, Group II was treated in the SLA method, and Group III was treated in the Ca-P coating with the anodizing method and the hydroxyapatite was crystallized on the surface with the hydrothermal treatment. Firstly, the surface roughness of each group was measured, 45 rabbits were used in this experiment. Two implants were inserted on right tibial metaphysis and one implant was inserted on left side with the alternating order. After the healing periods of 3, 5, and 12 weeks, the rabbits were sacrificed to evaluate the osseointergration by the removal torque test and the histomorphometric analysis. Results : 1. In the analysis for the surface roughness, Group II showed the highest roughness. And Group III showed higher secondly. There was a significant difference one another statistically 2. In the removal torque test, Group III and II were significantly higher than Group I. There was no statistical difference between Group III and Group II. 3. For all Groups, the removal torque values at 12th week were significantly higher than at 3rd and 5th week. 4. In histomorphometric analysis, the bone implant contact rates of Group III and II were higher than that of Group I at 3rd and 5th week. There was a significant difference at 5th week. 5. In histomorphometric analysis, the bone implant contact rate of Group III and II increased from 3rd week to 5th week, but decreased at 12th week. In Group I, the contact rate at 12th week was significantly higher than at 3rd week and 5th week.

섬유아세포 성장인자와 파이브로넥틴 복합 단백질로 처리한 타이태늄의 생물학적 효과;가토의 경골을 이용한 조직계측학적 분석 (In vivo assessment of Fibroblast growth factor(FGF)-Fibronectin fusion protein coating on titanium;Histomorphometric analysis in rabbit tibia)

  • 나호균;김태일;임상훈;조기영;정종평;한수부;구영
    • Journal of Periodontal and Implant Science
    • /
    • 제35권1호
    • /
    • pp.153-161
    • /
    • 2005
  • 파이브로넥틴은 세포외기질에 존재하는 당단백질로 세포의 부착, 이동, 성장 및 분화에 관여하며, 섬유아세포 성장인자는 세포의 증식 이동 및 분화에 영향을 주는 중요한 성장인자로 알려져 있다. 최근 연구에 의하면, 파이브로넥틴은 조골세포의 타이태늄 임플란트 표면으로 이주와 증식 및 골생성을 촉진하며, 섬유아세포 성장 인자는 파이브로넥틴에 상승작용을 한다고 보고된 바 있다. 이 실험의 목적은 파이브로넥틴 및 섬유아세포 성장인자의 복합 단백질을 이용하여 타이태늄 임플란트의 골 반응을 알아보는 것이다. 체중 2.5 kg 내외의 건강한 18 마리의 웅성가토를 준비하여 무균 사육하였고, 순수 타이태늄을 절삭가공하여 직경 3.5mm, 길이 6mm 의 machined surface를 지니는 screw type 의 임플란트를 준비하였다. 사람의 유전자를 기초로, 유전자 재조합법을 통해, 적절한 primer를 이용하여 얻은 섬유아세포 성장인자를 파이브로넥틴 III 형 분절의 9-10 번 도메인에 결합시켜 얻은 복합 단백질을 준비된 임플란트에 표면처리하여 실험군으로 하였고, 표면처리하지 않은 임플란트를 대조군으로 하여, 가토의 좌우 경골에 각각 2 개씩의 임플란트를 식립하였다. 4주 후, 가토를 희생시켜 각 경골 당 한 개의 임플란트에서 뒤틀림 제거력을 측정하였고 나머지 임플란트 식립 부위 에서는 경골을 포함하는 조직표본을 제작하였다. 조직표본상에서 골접촉이 가장 좋은 3 개의 나사산의 길이를 측정하고, 나사와 접촉하는 골의 길이를 측정하여 골-임플란트 접촉도를 구하고, 같은 부위에서 나사산 사이의 면적과 골이 차지하는 면적을 비교하여 골생성률을 얻었다. 실험군과 대조군의 결과는 Student t-test 를 이용하여 신뢰도 95% 수준에서 통계학적 유의성을 검정하였다. 파이브로넥틴과 섬유아세포 성장인자의 복합 단백질로 표면처리된 임플란트와 표면처리를 하지 않은 임플란트는 뒤틀림 제거력에서는 통계적 유의성이 나타나지 않았으나, 골-임플란트 접촉도와 골생성률에서 복합 단백질로 처리된 임플란트가 통계적으로 유의하게 높은 결과를 보였다. 이상의 연구결과로, 섬유아세포 성장인자와 파이브로넥틴 복합 단백질로 처리한 타이태늄 임플란트가 주변 골 형성을 촉진시켜, 골유합을 증진시킴을 알 수 있었다. 따라서, 복합 단백질이 타이태늄 임플란트의 성공률을 높이기 위한 표면개질 물질로 이용될 가능성을 확인할 수 있었다.

골절부위에 생긴 혈종의 골막하 이식이 골형성에 미치는 영향에 관한 실험적 연구 - 골스캔 소견을 중심으로 - (An Experimental Study on the Effect of Subperiosteal Transplantation of Fracture Site Hematoma: Focus on the Scintigraphic Detection)

  • 양승오;강흥식;장기현;이명철;구경회;성상철;박인애
    • 대한핵의학회지
    • /
    • 제24권1호
    • /
    • pp.124-132
    • /
    • 1990
  • It has been reported that hematoma is one of the most crucial factors in fracture healing since callus formation is disturbed by washing out the hematoma near a fracture site. However, it is not clear why the hamatoma is important and how it plays a role during the fracture healing. In order to investigate the role of hematoma in the process of fracture healing, the osteogenic potential by subperiosteal transplantation have been studied. Experimental fractures by operation were made at the mid-shaft of the tibia in New Zealand white rabbits. Removal of hematoma at the fracture site was done after 2 and 3 days from experimental fracture, and the removed hematoma was transplanted into the subperiosteal area at the mid-shaft of the ulna of each rabbit. As control groups, we have performed 3 different procedures 1) the hematoma was transplanted into the muscular layers at the thigh and forearm; 2) autologous blood clots were transplanted into the subperiosteal area of the ulna; and 3) sham operation without a transplantation into the subperiosteal area. After transplantation, serial bone scintigraphy and simple radiography were performed at 4 days, 1 week, and 2 weeks to detect an abnormality. The results of bone scintigraphy were positive in 5 of 6 experimental group. However, all in three control groups were negative. Histological observation of the positive bone revealed new bone formation with trabeculation. These results suggest the hematoma in fracture site has osteogenic potential in the subperiosteal area which can be demonstrable by bone scintigraphy and histologic findings. Therefore, it is considered that hematoma of the fracture site plays an important role in the process of fracture healing. Further biochemical investigation using various experimental models is mandatory to apply this preliminary result to the treatment of clinical delayed union or nonunion.

  • PDF

Effects of ibuprofen-loaded TiO2 nanotube dental implants in alloxan-induced diabetic rabbits

  • Kim, Young-Gyo;Kim, Wan-Tae;Jung, Bo Hyun;Yoo, Ki-Yeon;Um, Heung-Sik;Chang, Beom-Seok;Lee, Jae-Kwan;Choi, Won-Youl
    • Journal of Periodontal and Implant Science
    • /
    • 제51권5호
    • /
    • pp.352-363
    • /
    • 2021
  • Purpose: Some systemic conditions, especially diabetes mellitus (DM), adversely affect dental implant success. This study aimed to investigate the effects of ibuprofen-loaded TiO2 nanotube (ILTN) dental implants in alloxan-induced diabetic rabbits. Methods: Twenty-six New Zealand white rabbits were treated with alloxan monohydrate to induce DM. At 2 weeks following DM induction, 3 types of implants (sandblasted, large-grit, and acid-etched [SLA], ILTN, and machined) were placed into the proximal tibia in the 10 rabbits that survived following DM induction. Each type of implant was fitted randomly in 1 of the holes (round-robin method). The animals were administered alizarin (at 3 weeks) and calcein (at 6 weeks) as fluorescent bone markers, and were sacrificed at 8 weeks for radiographic and histomorphometric analyses. Results: TiO2 nanotube arrays of ~70 nm in diameter and ~17 ㎛ in thickness were obtained, and ibuprofen was loaded into the TiO2 nanotube arrays. A total of 26 rabbits were treated with alloxan monohydrate and only 10 rabbits survived. The 10 surviving rabbits showed a blood glucose level of 300 mg/dL or higher, and the implants were placed in these diabetic rabbits. The implant stability quotient (ISQ) and bone-to-implant contact (BIC) values were significantly higher in the ILTN group (ISQ: 61.8, BIC: 41.3%) and SLA group (ISQ: 62.6, BIC: 46.3%) than in the machined group (ISQ: 53.4, BIC: 20.2%), but the difference in the BIC percentage between the SLA and ILTN groups was not statistically significant (P=0.628). However, the bone area percentage was significantly higher in the ILTN group (78.0%) than in the SLA group (52.1%; P=0.000). Conclusions: The: ILTN dental implants showed better stability (ISQ) and BIC than the machined implants; however, these values were similar to the commercially used SLA implants in the 2-week diabetic rabbit model.

타이타늄 임플랜트 시편 내부에 설치한 자석의 자성강도에 따른 골형성 변화 (THE CHANGE OF BONE FORMATION ACCORDING TO MAGNETIC INTENSITY OF MAGNET PLACID INTO TITANIUM IMPLANT SPECIMENS)

  • 황윤태;이성복;최대균;최부병
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.232-247
    • /
    • 2005
  • Purpose. The purposes of this investigation were to discover the possibility of clinical application in the areas of dental implants and bone grafts by investigating the bone formation histologically around specimen which was depending on the intensity of magnetic field of neodymium magnet inside of the specimens. Material and method. 1. Measurement of magnetic intensity - placed the magnet inside of the specimen, and measured the intensity of magnetic field around the 1st thread and 3rd thread of specimen 20 times by using a Gaussmeter(Kanetec Co., Japan). 2. Surgical Procedure - Male rabbit was anesthetised by constant amount of Ketamine (0.25ml/kg) and Rompun (0.25ml/kg). After incising the flat part of tibia, and planted the specimens of titanium implant, control group was stitched without magnet, while experimental groups were placed a magnedisc 500(Aichi Steel Co., Japan) or magnedisc 800(Aichi Steel Co., Japan) into it, fixed by pattern resin and stitched. 3. Management after the surgery - In order to prevent it from the infection of bacteria and for antiinflammation, Gentamycin and Ketopro were injected during 1 week from operation day, and dressed with potadine. 4. Preparation of histomorphometric analysis - At 2, 4 and 8 weeks after the surgery, the animals were sacrificed by excessed Ketamine, and then, specimens were obtained including the operated part and some parts of tibia, and fixed it to 10% of PBS buffer solution. After embedding specimens in Technovit 1200 and B.P solution, made a H-E stain. Samples width was 75$\mu$m . In histological findings through the optical microscope and using Kappa image base program(Olympus Co. Japan), the bone contact ratio and bone area ratio of each parts of specimens were measured and analyzed. 5. Statistical analysis - Statistical analysis was accomplished with Mann Whitney U-test. Results and conclusion. 1. In histomorphometric findings, increased new bone formation was shown in both control & experimental groups through the experiment performed for 2, 4 & 8 weeks. After 4 weeks, more osteoblasts and osteoclasts with significant bone remodeling were shown in experimental groups. 2. In histomorphometric analysis, the bone contact ratios were 38.5% for experimental group 1, 29.5% for experimental group 2 and 11.9% for control group. Experimental groups were higher than control group(p<0.05) (Fig. 6, Table IV). The bone area ratios were 60.9% for experimental group 2, 46.4% for experimental group 1 and 36.0% for control group. There was no significantly statistical difference between experimental groups and control group(p<0.05) (Fig. 8, Table VII) 3. In comparision of the bone contact ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group at the 1st thread (p<0.05) and experimental group 1 (1.8mT) was higher than control group at the 3rd thread(p<0.05) (Fig. 7, Table V, VI). 4. In comparision of the bone area ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group and experimental group 1 (4.0mT) at the 1st thread(p<0.1) and experimental group 2(4.4mT) was higher than experimental group 1 (1.8mT) at the 3rd thread(p<0.1) (Fig. 9, Table IX, X). Experiment group 2 was largest, followed by experiment group l and control group at the 3rd thread of implant. There was a significant difference at the 1st thread of control group & experiment group 2, and at 1st thread & 3rd thread of experiment group 1 & 2, and not at control group experiment group 1.(p<0.1)

임플란트 고정체의 의원성 동요 후 골 유착 반응에 관한 연구 (Study of the re-osseointegration of implant fixture after mechanical unscrewing)

  • 장지훈;조진현;이청희
    • 대한치과보철학회지
    • /
    • 제48권3호
    • /
    • pp.209-214
    • /
    • 2010
  • 연구 목적: 본 연구의 목적은 골 유착된 임플란트에 인위적 비틀림을 가한 후 골 유착이 다시 일어나는지, 혹은 일어나지 않는지, 일어난다면 이전의 골유착보다 강화되는지, 약화되는지에 대해 알아보기 위함이다. 연구 재료 및 방법:상업적으로 순수한 티타늄 (commercial pure titanium 99%)으로 직경 3.75 mm, 길이 4 mm의 표면처리 없는 실험용 임플란트를 제작하였다. 3.0 kg이상의 뉴질랜드산 흰색 암컷 토끼 7마리의 좌우 경골에 제작한 임플란트를 2개씩 식립 후, 6주의 골유착 유도 기간 부여 후 비틀림 제거력을 측정한 경우를 I군으로, 다시 임플란트 고정체를 재위치시키고 봉합하여 4주간의 치유기간을 더 두고 측정한 경우를 II군으로 분류하였다. 광학현미경을 이용한 조직 형태학적 분석을 위하여, 1차 비틀림 제거력 측정 직후 1마리의 토끼를 희생시키고, 2차 비틀림 제거력 측정 직후 2마리의 토끼를 희생시켜 각각 4개, 7개의 시편을 제작하여, 광학현미경 (${\times}20$) 분석에서 골-임플란트 접촉 (Bone-Implant contact, BIC, %)비율과 치밀골 부위에 위치하는 임플란트의 나사산 수를 측정하여 CBa (Bone area in the cortical passage)비율을 측정하였다. 비틀림 제거력과 BIC및 CBa비율에서의 I군과 II군의 통계적 유의성 ($\alpha$=.05)을 평가하였다. 결과: 비틀림 제거력 측정에서 I군은 $10.8{\pm}3.6$ NCm로 측정되었으며, II군은 $20.2{\pm}9.7$ NCm로 측정되었으며, I군보다II군의 비틀림 제거력이 평균 98.1% 증가되었다 (P<.05). 조직 형태학적 분석에서 BIC와 CBa 비율은 I군과 II군 사이에 통계적 유의성을 나타내지 않았고 (P>.05), RT/BIC와 RT/CBa 값은 I군과 II군 사이에 통계적 유의성을 나타냈다 (P<.05). 결론: 임플란트 고정체에 의원성 비틀림 동요가 발생한 경우에 초기 골유착을 얻기 위해 필요로 했던 치유기간보다 짧은 기간 내에 이전보다 견고한 골유착을 얻을 수 있을 것으로 생각된다.

AN EXPERIMENTAL STUDY OF NEWLY DESIGNED IMPLANT WITH RBM SURFACE IN THE RABBIT TIBIA : RESONANCE FREQUENCY ANALYSIS AND REMOVAL TORQUE STUDY

  • Won Mi-Kyoung;Park Chan-Jin;Chang Kyoung-Soo;Kim Chang-Whe;Kim Yung-Soo;Isa Zakiahbt Mohd;Ariffin Yusnidar Tajul
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.720-731
    • /
    • 2003
  • Statement of problem. The importance of fixture design and surface treatment. Purpose. The clinical success of dental in plants is affected by many factors such like as degree of osseointegration, the effective load dispersion for the prostheses, and a lot of attempts have been made to overcome the difficulties. In this study, efforts were made to find the possibility of clinical acceptance of the dental implants of newly designed surface and resorbable blast media surcace. Materials and methods. In this study, two groups of custom-made, screw-shaped implants were prepared. The first with the consisting of Branemark clone design and the other with the new design. These implants were divided into four groups according to the kinds of surface treatment. Four implants($AVANA^{(R)}$, Osstem, Busan, Korea)of each group were installed in twenty rabbits. Group A was consisted of Branemark done implant left as machined, Group B with Branemark clone implants with RBM(Resorbable blast media) surface, Group C with newly designed implants left as machined and Group D with newly designed implants with RBM surface. One of the twenty rabbits died from inflammation and the observation was made for six weeks. Specimens from four groups were observed using scanning electron microscopy with 40, 100, 1000 magnification power and microsurface structures were measured by white-light scanning interferometry for three dimensional surface roughness measurements(Accura $2000^{(R)}$, Intek-Plus, Korea.). Removal torque was measured in 17 rabbits using digital torque gauge(MGT 12R, Mark-10 corp., NY, U.S.A.) immediately after the sacrifice and two rabbits were used for the histologic preparation(EXAKT $310^{(R)}$, Heraeus Kulzer, wehrheim, Germany) of specimens and observed under light microscope. Resonance frequency measurement($Osstell^{(R)}$) was taken with the 19 rabbits at the beginning of the implant fixation and immediately after the sacrifice. Results. Following results were taken from the experiment. 1. The surface of the RBM implants as seen with SEM had rough and irregular pattern with reticular formation compared to that of fumed specimens showing different surface topographies. 2. The newly designed implant with RBM surface had high removal torque value among four groups with no statistical significance. The average removal torque was $49.95{\pm}6.70Ncm$ in Group A, $51.15{\pm}4.40Ncm$ in Group B, $50.78{\pm}9.37Ncm$ in Group C, $51.09{\pm}4.69Ncm$ in Group D. 3. The RFA values were $70.8{\pm}4.3Hz$ in Group A, $71.8{\pm}3.1Hz$ in Group B, $70.9{\pm}2.5Hz$, $72.7{\pm}2.5Hz$ in Group D. Higher values were noted in the groups which had surface treatment compared to the untreated groups with no statistical significance. 4. The results from the histomorphometric evaluation showed a mean percentage of bone-to-implant contact of $45{\pm}0.5%$ in Group A, $55{\pm}3%$ in Group B, $49.5{\pm}0.5%$ in Group C, and $55{\pm}3%$ in Group D. Quite amount of newly formed bone were observed at the surface RBM-treated implants in bone marrow space.