• Title/Summary/Keyword: Rabbit radius

Search Result 7, Processing Time 0.023 seconds

Bone Healing Properties of Autoclaved Autogenous Bone Grafts Incorporating Recombinant Human Bone Morphogenetic Protein-2 and Comparison of Two Delivery Systems in a Segmental Rabbit Radius Defect

  • Choi, Eun Joo;Kang, Sang-Hoon;Kwon, Hyun-Jin;Cho, Sung-Won;Kim, Hyung Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.3
    • /
    • pp.94-102
    • /
    • 2014
  • Purpose: This study aims to validate the effect of autoclaved autogenous bone (AAB), incorporating Escherichia coli-derived recombinant human bone morphogenetic protein-2 (ErhBMP-2), on critical-sized, segmental radius defects in rabbits. Delivery systems using absorbable collagen sponge (ACS) and fibrin glue (FG) were also evaluated. Methods: Radius defects were made in 12 New Zealand white rabbits. After autoclaving, the resected bone was reinserted and fixed. The animals were classified into three groups: only AAB reinserted (group 1, control), and AAB and ErhBMP-2 inserted using an ACS (group 2) or FG (group 3) as a carrier. Animals were sacrificed six or 12 weeks after surgery. Specimens were evaluated using radiology and histology. Results: Micro-computed tomography images showed the best bony union in group 2 at six and 12 weeks after operation. Quantitative analysis showed all indices except trabecular thickness were the highest in group 2 and the lowest in group 1 at twelve weeks. Histologic results showed the greatest bony union between AAB and radial bone at twelve weeks, indicating the highest degree of engraftment. Conclusion: ErhBMP-2 increases bony healing when applied on AAB graft sites. In addition, the ACS was reconfirmed as a useful delivery system for ErhBMP-2.

New Bone Formation in Experimental Model of Vascularized Periosteal Flap for the Bone Defect in the Shaft of the Radius of Rabbit - Radiological, Histological and Immunohistochemical Study - (가토 요골 간부 골 결손시에 혈관 부착 골막 보존 유무에 따른 신생골 형성에 대한 실험적 연구)

  • Chung, Duke-Whan;Yum, Jae-Kwang;Tae, Suk-Kee;Ko, Kwang-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.2
    • /
    • pp.97-107
    • /
    • 1999
  • The osteogenic capacity of the vascularized periosteum autograft has been extensively demonstrated by experimental works. The objective of this study was to characterize the behavior of experimental model of vascularized periosteal flap(VPF) by observing sequential stages of osteogenesis after simulated VPF in rabbits. In experimental group, segmental resection of bone including the periosteum was performed in 22 radii of 22 New Zealand white rabbits preserving the periosteal circulation of median artery to the periosteum. In order to simulate the transplantation of VPF, the vascular pedicle consisting of median artery and veins was dissected from adjacent soft tissue and the periosteum was longitudinally incised to remove the bone followed by repair of the periosteum. From the first to sixteenth week after the simulated VPF, the changes in VPFs were observed by radiological, light microscopical, scanning electron microscopical methods and the activity of osteocalcin was measured by immunohistochemical method. In control group, the bone tissue and periosteum were completely removed from the mid-shaft of radius and the findings were observed by radiological and light microscopical methods. From the results of this study, it is demonstrated that the experimental model of VPF is vigorously and uniformly osteogenic. Therefore it is thought that VPF can be used as a measure to treat bone defect of shaft of long bone.

  • PDF

Characteristics of Rotating Stall in a Centrifugal Compressor with Vaned Diffuser (원심압축기 베인 디퓨저에서의 선회실속 특성)

  • Lee, Du-Yeol;Kang, Chang-Sik;Shin, You-Hwan;Kim, Kwang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.1 s.14
    • /
    • pp.42-48
    • /
    • 2002
  • In this study, the instability of a centrifugal compressor with vaned diffuser was investigated. During unstable operation of the test compressor, pressure fluctuations at different diffuser radius ratios were measured by using high frequency pressure transducers. Two different types of stall, mild and deep stalls, were observed alternately and irregularly at some flow rates where the compressor performance was steeply deteriorated. In this transient zone, the size of rotating stall cell was estimated through the wavelet transform analysis. It was about 45 percents of rotor circumferential space at 300 rpm and not dependent on flow rate.

Characteristics of Rotating Stall in a Centrifugal Compressor with Vaned Diffuser (원심압축기 베인 디퓨저에서의 선회실속 특성)

  • Lee, Du-Yeol;Kang, Chang-Sik;Shin, You-Hwan;Kim, Kwang-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.99-105
    • /
    • 2001
  • In this study, the instability of a centrifugal compressor with vaned diffuser was investigated. During unstable operation of the test compressor, pressure fluctuations at different diffuser radius ratios were measured by using high frequency pressure transducers. Two different types of stall, mild and deep stall, were observed alternately and irregularly at some flow rate where the compressor performance was steeply deteriorated. In this transient zone, the size of rotating stall cell was estimated through the Wavelet transform analysis. It was about 45 percents of rotor circumferential space at 3000 rpm and not dependent on flow rate.

  • PDF

BONE HEALING CAPACITY IN THE FRACTURE OF RABBIT MANDIBULAR BONE USING LOW-LEVEL LASER (가토 하악골 절단부의 저수준 레이저 처치가 골치유에 미치는 영향)

  • Bae, Yong-Hyeon;Han, Se-Jin;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.2
    • /
    • pp.120-124
    • /
    • 2009
  • The concept of biostimulation of wounds by low-level laser therapy(LLLT) is attracting considerable attention. Although its effect on whole tissues has been studied quite extensively, the biological and cellular mechanisms underlying LLLT have not been clarified. In an experimental radius fracture in rabbits, Tang and Chai reported that LLLT enhanced the activity of red blood cells, macrophages, fibroblasts, chondrocytes, and osteoclasts within the fracture area. The purpose of the present study was to evaluate the effect of LLLT with a GaAlAs diode laser device on bone healing in rabbit mandibular fractures. We use 12 rabbits for this study. All rabbits were fractured mandible angle area using saw in anesthetic condition. In control group(n=6), none treatment was performed at fracture site. In experimental group(n=6), LLLT with a GaAlAs diode laser was radiated at fracture site daily for 7 days. All rabbits were sacrificed at 6 weeks later from performed fracture day. We studied the immunohistochemical staining of CD34 and Vimentin and the histochemical analysis for calcium and phosphorus content. The results were as follows. 1. In the histological and immunohistological staining, after 6week, fibroblasts, osteogenic cells and collgen fibers were observed more in experimental group than in control group. 2. In the histochemical analysis, the amount of calcium and phosphorus contents of the experimental group were more than the control group. From the results obtained, we suggest that the bone healing is stimulated by low-level laser irradiation in bone fractures.

The Effect of Negative electric field using charged PTFE membrane on Bone Healing of Rabbit Long Bone (Charged membrane에 의한 negative electric field가 토끼 장골의 골 치유에 미치는 영향)

  • Kwon, Yong-Su;Park, Jin-Woo;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.551-562
    • /
    • 2004
  • The purpose of this study was to evaluate the effects of negatively electric field on bone healing in rabbit segmental long bone defects using negatively charged PTFE membrane. Ten millimeter segmental defects in the rabbit radius were used as the experimental model. After membranes were then charge injected using a corona-charging apparatus, the left defects were covered with non charged PTFE membranes as control groups, whereas the right defect was covered with negatively charged PTFE membranes as test group. The animals were divided into 4 groups of 2 rabbits each, and sacrificed at 2, 4, 6, and 8 weeks. Histomorphometric analysis showed a more newly formed bone in negatively charged membrane at early healing period. At 2 weeks, the proportion of new bone formation to total defect area was 0.32% in control group, 1.10% in experimental group. At 4 weeks, the proportion of new bone formation to total defect area was 6.86% in control, and 13.75% in experimental. At 6 and 8 weeks, no obvious difference was found between the two groups but newly formed bone in test groups were slightly more than that in control groups. In conclusion, negatively charged membranes showed more newly bone tissue than noncharged membranes at an early healing period. Although the number of samples was small, this study showed that the combination of negatively electrical stimulation and P1FE membrane may be of value in long bone healing.