• 제목/요약/키워드: RUNOff RATE

검색결과 442건 처리시간 0.032초

EVALUATION OF THE WATER RESOURCES ASPECT OF THE OPERATING RESULTS OF THE DAECHEONG MULTIPURPOSE DAM

  • Noh, Jaek-young
    • Water Engineering Research
    • /
    • 제5권1호
    • /
    • pp.17-36
    • /
    • 2004
  • This paper evaluated the water resources aspect of the operating results of the Daecheong Multipurpose Dam for the last 21 years. The elements that were evaluated included the amount of water supply from the dam. volume of outflow from the regulating dam, changes in the runoff volume at the dam site and downstream, and variations in the water supply capacity of the Daecheong Multipurpose Dam and the Geum River Barrage Dam situated in the estuary. The rainfall-runoff model was used to evaluate the changes in the runoff volume, and the water balance analysis system was used to evaluate the variations in the dams'water supply capacities. The volume of domestic and industrial water supply from the Daecheong Multipurpose Dam increased to 6.1 times for the last 21 years from 61${\times}$$10^6$$m^3$ in 1981 to 375${\times}$$10^6$$m^3$in 2001. The rate of outflow to inflow of the Daecheong Dam was analyzed 1.30 times in dry season, 1.12 times in semi-dry season, and 0.90 times in rainy season. The volume of inflow to the Geum River Barrage Dam down- stream after the dam's construction increased to 1.25 times in dry season and 1.02 times in semi-dry season and decreased to 0.94 times in rainy season. The water supply capacity of the estuary barrage dam almost did not change in cases with or without the Daecheong Multipurpose Dam, but storages were largely affected by the outflows of the Daecheong Multipurpose Dam.

  • PDF

최적화 기법을 이용한 임하호유역 대표 CN값 추정 (Regionalization of CN values at Imha Watershed with SCE-UA)

  • 전지홍;김태동;최동혁
    • 한국농공학회논문집
    • /
    • 제53권5호
    • /
    • pp.9-16
    • /
    • 2011
  • Curve Numbers (CN) for the combination of land use and hydrologic soil group were regionalized at Imha Watershed using Long-term Hydrologic Impact Assessment (L-THIA) coupled with SCE-UA. The L-THIA was calibrated during 1991-2000 and validated during 2001-2007 using monthly observed direct runoff data. The Nash-Sutcliffe (NS) coefficients for calibration and validation were 0.91 and 0.93, respectively, and showed high model efficiency. Based on the criteria of model calibration, both calibration and validation represented 'very good' fit with observe data. The spatial distribution of direct surface runoff by L-THIA represented runoff from Thiessen pologen at Subi and Sukbo rain gage station much higher than other area due to the combination of poor hydrologic condition (hydrologic soil C and D group) and locality heavy rainfall. As a results of hydrologic condition and treatment for land use type based on calibrated CNs, forest is recommended to be hydrologically modelled dived into deciduous, coniferous, and mixed forest due to the hydrological difference. The CNs for forest and upland showed the poor hydrologic condition. The steep slope of forest and alpine agricultural field make high runoff rate which is the poor hydrologic condition because CN method can not consider field slope. L-THIA linded with SCE-UA could generated a regionalized CNs for land use type with minimized time and effort, and maximized model's accuracy.

도로노면 유출수 처리를 위한 여과에서의 여재별 손실수두 특성 (A study on the headloss of filter media for treatment of Road Runoff)

  • 최원석;송창수;김석구
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.697-704
    • /
    • 2008
  • Stormwater runoff from urban road area as non-point source has a tendency of including lots of pollutants at initial rain period. Recently, there are several cases of having installed treatment facilities for reducing pollution discharge from the impervious cover in urban area to prevent watershed environment from getting worse. The filtration type among non-point source treatment systems has been known as one of the most efficient system for treatment of non-point source pollutants. Therefore, various kinds of filter media such as expanded polypropylene(EPP), granular activated carbon, zeolite, perlite, illite, sand, gravel has been developed. This study was conducted to verify performance and hydraulic characteristics of filter media as measures for non-point source. The experiment was carried out to evaluate applicability and variation of 4 kind of most popular filter media(EPP, GAC, Zeolite, Perlite) in headloss with elapsed time and influent flow rate and to obtain data base that could be used to establish management plan for road runoff treatment. In experiment by tap water, it showed that EPP and perlite those are floatable materials showed stable operating performance and lower headloss than the others.

XP-SWMM을 이용한 도시화 유역에서의 유출 관리 방안 연구 (Management Scheme of Urbanization Runoff Using XP-SWMM)

  • 이범희;채준영
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.1167-1172
    • /
    • 2004
  • 최근 급격한 인구증가와 산업화, 도시화로 포장지역의 증가에 따른 불투수지역의 증가로 유역의 유출 특성의 변화를 유발시키고 있다. 도시화 유역의 효율적인 관리를 위해서는 유역에 내할 정확할 지형인자 및 수문 관련 인자들을 추출해야 한다. 본 연구에서는 GIS와 XP-SWMM을 이용하여 안양천유역의 유출분석을 수행하였다. 안양천 유역을 GIS를 이용하여 13개의 소유역으로 분할하고 입력자료를 구축하였다. GIS를 이용하여 지형도로부터 각각의 소유역에 대하여 면적, 경사도, 폭과 하천 각 구간의 길이, 경사도를 얻었고, 토지이용도와 토양도로부터 불투수비, 토지이용상태, 침투능에 내한 정보를 얻었다. 여기서 얻은 결과를 토대로, 안양천 유역에 도시유출 모형인 XP-SWMM을 적용하여 도시화유역의 관리방안을 제시하였다.

  • PDF

강우시 도시지역 비점오염원 유출특성 분석 - 홍제천 상류 유역을 중심으로 - (Analyzing Runoff Characteristics of Nonpoint Sources During Rainfall in Urban Area - Focussing on upstream of Hongjechun watershed)

  • 황병기
    • 환경영향평가
    • /
    • 제14권2호
    • /
    • pp.63-73
    • /
    • 2005
  • This study was performed to characterize stormwater runoff of pollution material from nonpoint sources during rainfall in drainage basins of Hongjechun watershed, and to suggest management methods to control the first flush of nonpoint sources. We conducted 4 times of field surveys including 3 times of wet period and 1 times of dry period for 5 stations, which consist of 3 stations in main stream of Hongjechun and 1 station in tributaries of Sinyoungchun and Gukichun, respectively. The variation of pollutant concentrations in terms of BOD, COD, SS and TP was large depending on the flow rate of stormwater, while a little change of TN concentration was investigated. Depending on the rainfall event, the difference of flowrates, and runoff loadings was large, while the difference of those for dry wether period was not noticeable for various sub-basins. In the results of unit load calculation, the range of 153-277 kg/ha/yr for BOD, 222-422 kg/ha/yr for COD, 264-432 kg/ha/yr for SS, 40-70kg/ha/yr for TN, and 13-25 kg/ha/yr for TP was obtained for Hongjechun, Sinyoungchun, and Gukichun sub-basins. Compared with the previous studies, the result of this study was founded to be acceptable.

CN의 시공간적 변화를 고려한 용산 물순환 환경도시계획의 비점오염물질 저감효과 비교 (Comparison of NPS Reduction at Yongsan Area Considering Spatio-Temporal Chnages in CN)

  • 최재완;이성준;류지철;신동석;임경재
    • 한국환경과학회지
    • /
    • 제21권10호
    • /
    • pp.1203-1212
    • /
    • 2012
  • Yongsan ward is located at central place connecting south and north ecology axis of seoul. Various environment-friendly Yongsan development could pose positive effects on NPS(non pollutant source) pollutant reductions and water quality improvement at Han-rive because BOD, T-N, and T-P NPS discharges took 90% of total pollutant from this area. In this study, direct runoff and NPS pollutant loads were evaluated before and after development using spatio-tamporal change in CN(curve number) and EMC(event mean concentration) data. It was found that direct runoff value is $23,584,724m^3$, and BOD, T-N and T-P loads are 104,456 kg/year, 111,483 kg/year and 7,500 kg/year under pre-development condition, respectively. Annual runoff, BOD, T-N and T-P reducing rate were 12.9%, 33.3%, 35.6% and 40.7% under integrated post-development condition, respectively. Based on the results obtained in this study, environment-friendly urban development could be achieved at Yongsan area.

Factors affecting the infiltration rate and removal of suspended solids in gravel-filled stormwater management structures

  • Guerra, Heidi B.;Yuan, Qingke;Kim, Youngchul
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.67-74
    • /
    • 2019
  • Apparent changes in the natural hydrologic cycle causing more frequent floods in urban areas and surface water quality impairment have led stormwater management solutions towards the use of green and sustainable practices that aims to replicate pre-urbanization hydrology. Among the widely documented applications are infiltration techniques that temporarily store rainfall runoff while promoting evapotranspiration, groundwater recharge through infiltration, and diffuse pollutant reduction. In this study, a laboratory-scale infiltration device was built to be able to observe and determine the factors affecting flow variations and corresponding solids removal through a series of experiments employing semi-synthetic stormwater runoff. Results reveal that runoff and solids reduction is greatly influenced by the infiltration capability of the underlying soil which is also affected by rainfall intensity and the available depth for water storage. For gravel-filled structures, a depth of at least 1 m and subsoil infiltration rates of not more than 200 mm/h are suggested for optimum volume reduction and pollutant removal. Moreover, it was found that the length of the structure is more critical than the depth for applications in low infiltration soils. These findings provide a contribution to existing guidelines and current understanding in design and applicability of infiltration systems.

Potential soil loss evaluation using the RUSLE/RUSLE-runoff models in Wadi Saida watershed (N-W Algeria)

  • Cherif, Kessar;Yahia, Nasrallah;Bilal, Bilssag
    • Advances in environmental research
    • /
    • 제9권4호
    • /
    • pp.251-273
    • /
    • 2020
  • Soil degradation has become a major worldwide environmental problem, particularly in arid and semi-arid climate zones due to irregular rainfall and the intensity of storms that frequently generate heavy flooding. The main objective of this study is the use of geographic information system and remote sensing techniques to quantify and to map the soil losses in the Wadi Saida watershed (624 ㎢) through the revised universal soil loss equation model and a proposed model based on the surface erosive runoff. The results Analysis revealed that the Wadi Saida watershed showed moderate to moderately high soil loss, between 0 and 1000 t/㎢/year. In the northern part of the basin in the region of Sidi Boubkeur and the mountains of Daia; which are characterized by steep slopes, values can reach up to 3000 t/㎢/year. The two models in comparison showed a good correlation with R = 0.95 and RMSE = 0.43; the use of the erosive surface runoff parameter is effective to estimate the rate of soil loss in the watersheds. The problem of soil erosion requires serious interventions, particularly in basins with disturbances and aggressive climatic parameters. Good agricultural practices and forest preservation areas play an important role in soil conservation.

수문학적 가뭄전망을 위한 GloSea5의 활용체계 구축 및 예측성 평가 (Construction & Evaluation of GloSea5-Based Hydrological Drought Outlook System)

  • 손경환;배덕효;정현숙
    • 대기
    • /
    • 제25권2호
    • /
    • pp.271-281
    • /
    • 2015
  • The objectives of this study are to develop a hydrological drought outlook system using GloSea5 (Global Seasonal forecasting system 5) which has recently been used by KMA (Korea Meteorological Association) and to evaluate the forecasting capability. For drought analysis, the bilinear interpolation method was applied to spatially downscale the low-resolution outputs of GloSea5 and PR (Predicted Runoff) was produced for different lead times (i.e., 1-, 2-, 3-month) running LSM (Land Surface Model). The behavior of PR anomaly was similar to that of HR (Historical Runoff) and the estimated values were negative up to lead times of 1- and 2-month. For the evaluation of drought outlook, SRI (Standardized Runoff Index) was selected and PR_SRI estimated using PR. ROC score was 0.83, 0.71, 0.60 for 1-, 2- and 3-month lead times, respectively. It also showed the hit rate is high and false alarm rate is low as shorter lead time. The temporal Correlation Coefficient (CC) was 0.82, 0.60, 0.31 and Root Mean Square Error (RMSE) was 0.52, 0.86, 1.20 for 1-, 2-, 3-month lead time, respectively. The accuracy of PR_SRI was high up to 1- and 2-month lead time on local regions except the Gyeonggi and Gangwon province. It can be concluded that GloSea5 has high applicability for hydrological drought outlook.

L-THIA를 이용한 낙동강수계 임하댐유역 비점오염원의 공간적 분포해석 (Spatial Analysis of Nonpoint Source Pollutant Loading from the Imha dam Watershed using L-THIA)

  • 전지홍;다니엘차;최동혁;김태동
    • 한국농공학회논문집
    • /
    • 제55권1호
    • /
    • pp.17-29
    • /
    • 2013
  • Long-Term Hydrologic Impact Assessment (L-THIA) model which is a distributed watershed model was applied to analyze the spatial distribution of surface runoff and nonpoint source pollutant loading from Imha watershed during 2001~2010. L-THIA CN Calibration Tool linked with SCE-UA was developed to calibrate surface runoff automatically. Calibration (2001~2005) and validation (2006~2010) of monthly surface runoff were represented as 'very good' model performance showing 0.91 for calibration and 0.89 for validation as Nash-Sutcliffe (NS) values. Average annual surface runoff from Imha watershed was 218.4 mm and Banbyun subwatershed was much more than other watersheds due to poor hydrologic condition. Average annual nonpoint source pollutant loading from Imha wateshed were 2,295 ton/year for $BOD_5$, 14,752 ton/year for SS, 358 ton/year for T-N, and 79 ton/year for T-P. Amount of pollutant loading and pollutant loading rates from Banbyun watershed were much higher than other watersheds. As results of analysis of loading rate from grid size ($30m{\times}30m$), most of high 10 % of loading rate were generated from upland. Therefore, major hot spot area to manage nonpoint source pollution in Imha watershed is the combination of upland and Banbyun subwatershed. L-THIA model is easy to use and prepare input file and useful tool to manage nonpoint source pollution at screening level.