• 제목/요약/키워드: RTD sensor

검색결과 41건 처리시간 0.027초

Lift-off법에 의한 RTD의 제조 (The fabrication of RTD via Lift-off process)

  • 김종성;원종각
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.299-302
    • /
    • 2000
  • RTD temperature sensor is a thermoresistor which uses the liner dependence of the resistance of the sensing material on the temperature, and has good stability and sensibility, so it can be used in highly precise temperature measurement. In this study RTD sensor was fabricated using Pt thin film. The Pt thin film was deposited on alumina using DC-Sputter, and annealed with various temperature. Through the experiments of XRD, AFM, 4-point probe, the surface structure of the thin film with annealing conditions and their effects on the electrical resistance were investigated. RTD with serpentine pattern was fabricated using Lift-off and resistance-temperature characteristics were studied.

  • PDF

곡면 유리 표면 위에서 박막 측온저항체 온도센서 어레이 제작 및 성능 평가 (Fabrication and Performance Evaluation of Thin Film RTD Temperature Sensor Array on a Curved Glass Surface)

  • 안철희;김형훈;박상후;손창민;고정상
    • 한국가시화정보학회지
    • /
    • 제9권2호
    • /
    • pp.34-39
    • /
    • 2011
  • This paper presents a novel direct fabrication method of the thin metal film RTD temperature sensor array on an arbitrary curved surface by using MEMS technology to measure a distributed temperature field up to $300^{\circ}C$ without disturbing a fluid flow. In order to overcome the difficulty in the three dimensional photography of sensor patterning, the UV pre-irradiated photosensitive dry film resist technology has been developed newly. This method was applied to the fabrication of the temperature sensor array on a glass tube, which is arranged parallel and transverse to a main flow. Gold was used as a temperature sensing material. The resistance change was measured in a thermally controlled oven by increasing the environmental temperature. The linear increase in resistance change and a constant slope were obtained. Also, the sensitivity of each RTD temperature sensor was evaluated.

측온저항체 온도센서용 백금박막의 형성에 관한 연구 (The study on formation of platinum thin films for RTD temperature sensor)

  • 정귀상;노상수
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권9호
    • /
    • pp.911-917
    • /
    • 1996
  • Platinum thin films were deposited on Si-wafer by DC rnagnetron sputtering for RTD (resistance thermometer devices). We investigated the physical and electrical characteristics of these films under various conditions, the input power, working vacuum, temperature of substrate and also after annealing these films. The deposition rate was increased with increasing the input power but decreased with increasing Ar gas pressure. The resistivity and sheet resistivity were decreased with increasing the temperature of substrate and the annealing time at 1000.deg. C. At substrate temperature of >$300^{\circ}C$, input power of 7 w/cm$^{2}$, working vacuum of 5 mtorr and annealing conditions of 1000.deg. C and 240 min, we obtained 10.65.mu..ohm..cm, resistivity of Pt thin films and 3800-3900 ppm/.deg. C, TCR(temperature coefficient of resistance). These values are close to the bulk value. These results indicate that the Pt thin films deposited by DC magnetron sputtering have potentiality for the development of Pt RTD temperature sensor.

  • PDF

RTD 및 피에조 센서를 활용하는 풍향/풍속 측정장치 개발 (The Developement of a Wind Direction/Speed Measurement Equipment Using RTD or Piezo Sensors)

  • 주재훈;김동현;공병권;이진호;최중경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 춘계학술대회
    • /
    • pp.827-830
    • /
    • 2011
  • 본 논문에서는 풍향 풍속 계측모듈 및 DSP 센서인터페이스 회로시스템을 제안한다. 이 DSP 시스템은 풍향 풍속모듈, 대기압센서, 대기 온도 센서의 정보를 받아들이고, 빠르게 처리하여 PC 모니터링 시스템에 전달한다. 특히 풍향 풍속 모듈과 DSP 하드웨어는 직접 설계하여 적용한다. 풍향 풍속 모듈은 바람에 관한 벡터적 정보를 얻기 위해 4개의 박막형 RTD(Resistive Temperature Detectors) 또는 박박형 피에조센서를 원기둥 모양의 지지표면에 벡터적으로 배치하는 구조를 채택한다. 이 구조를 채택한 계측 모듈은 진동, 습기, 부식 등에 강인하면서 정확한 계측을 가능케 한다. 센서 신호처리 회로는 TI 사의 고속 DSP인 TMS320F2812 를 사용한다.

  • PDF

온도센서가 집적된 WLP LED의 제작과 이를 통한 광 특성 보상 시스템의 구현 (Fabrication of the Wafer Level Packaged LED Integrated Temperature Sensor and Configuration of The Compensation System for The LED's Optical Properties)

  • 강인구;김진관;이희철
    • 대한전자공학회논문지SD
    • /
    • 제49권7호
    • /
    • pp.1-9
    • /
    • 2012
  • 기존의 LED 패키지가 갖는 온도에 따른 광 특성 변화 문제를 해결하기 위하여 온도센서가 집적된 LED 패키지 시스템을 제안하였다. 패키지의 온도를 실시간으로 측정하기 위하여 정확도가 우수하며 온도에 따른 저항의 변화가 선형적인 특징을 갖는 온도센서(RTD 형)를 설계하였으며, 장기간의 안정성을 보장하기 위하여 안정된 박막의 증착조건을 결정하고 이를 바탕으로 $1.560{\Omega}/^{\circ}C$의 민감도를 갖는 온도센서를 패키지 내부에 제작하였다. 제작된 패키지를 이용하여 온도에 무관하게 일정한 광량을 나타내는 시스템의 구현을 위하여 변환 회로부와 제어 회로부를 제작하고 이들을 결합함으로써, 패키지의 온도 변화에 따라 PWM duty ratio의 변화를 통해 광 출력을 보상해 주는 시스템을 제안하고 제작하였다. LED의 동작온도인 $0^{\circ}C$에서 $140^{\circ}C$ 범위에서 PWM duty ratio를 관측한 결과 제안했던 일정한 광량을 위한 PWM duty ratio에 매우 근접한 출력 신호를 발생시키는 것을 확인할 수 있었다.

급탄관 온도 측정시스템의 특성 비교분석에 관한 연구 (A study on the characteristic comparision of systems which measure the temperature of coal powder in feader lines of boiler)

  • 오면택;이복규;이원빈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.597-600
    • /
    • 1996
  • This study has compared the two types of systems which measure the temperature of coal powder in feeder lines of boiler and analyzed operating data. We used RTD(Resistance Temperature Detector) and optic sensors to measure the temperature. From the characteristic comparison of data, field test and system operation, we confirm that the latter is more efficient than the former.

  • PDF

환경모니터링 센서가 집적된 LED 조명용 광학시트 제작 (Fabrication of Optical Sheet for LED Lighting with Integrated Environment Monitoring Sensors)

  • 최용준;이영태
    • 반도체디스플레이기술학회지
    • /
    • 제12권3호
    • /
    • pp.35-39
    • /
    • 2013
  • In this paper, we developed an optical sheet for LED lighting with integrated $CO_2$ gas and temperature sensor which can monitor at the indoor environment. The optical sheet for LED lighting is fabricated through PMMA(Polymethyl methacrylate) injection process using mold. This research enables to fabricate the reflective sheet, light-guide plate and the prism sheet in a optical sheet. The fabricated sheet demonstrates higher intensity of optical efficiency compared with single-sided sheets. The $CO_2$ sensor was fabricated using NDIR(NON-Dispersive Infrared) method and it has $0.0235mV/V{\cdot}PPM$ sensitivity. The temperature sensor was fabricated using RTD(Resistance temperature detector) method and it has $0.563{\Omega}/^{\circ}C $sensitivity.

3C-SiC 마이크로 히터의 제작과 그 특성 (Fabrication of 3C-SiC micro heaters and its characteristics)

  • 정귀상;정재민
    • 센서학회지
    • /
    • 제18권4호
    • /
    • pp.311-315
    • /
    • 2009
  • This paper describes the characteristics of a poly 3C-SiC micro heater which was fabricated on AlN(0.1 $\mu$m)/3C-SiC(1.0 $\mu$m) suspended membranes by surface micro-machining technology. The 3C-SiC and AlN thin films which have wide energy band gap and very low lattice mismatch were used sensors for high temperature and voltage environments. The 3C-SiC thin film was used as micro heaters and temperature sensor materials simultaneously. The implemented 3CSiC RTD(resistance of temperature detector) and the power consumption of micro heaters were measured and calculated. The TCR(thermal coefficient of the resistance) of 3C-SiC RTD is about -5200 ppm/$^{\circ}C$ within a temperature range from 25 $^{\circ}C$ to 50 $^{\circ}C$ and -1040 ppm/$^{\circ}C$ at 500 $^{\circ}C$. The micro heater generates the heat about 500 $^{\circ}C$ at 10.3 mW. Moreover, durability of 3C-SiC micro heaters in high voltages is better than Pt micro heaters. A thermal distribution measured and simulated by IR thermovision and COMSOL is uniform on the membrane surface.

반도체 테스트 핸들러의 온도 제어 시스템 개발 I - 시스템 구성 (Development of Temperature Control Xystem for Semiconductor Test Handler I-System Design)

  • 조수영;이호준;이성은;김영록
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.73-76
    • /
    • 1997
  • The temperature control system for semiconductor test handler is designed. We controlled the temperature of chamber using 3-wire RTD sensor and MVME EMbedded controller. VxWorks that is a real-time operating system is used and heater is controlled by PWM. Temperature fluctuation of chamber is decreased within 0.3.deg. C, which is about one-half of that of commercial controller.

  • PDF

Cold electronics based 128 temperature sensor interface with 14 leads for testing of high Tc superconducting cable

  • Gour, Abhay Singh;Thadela, S.;Rao, V.V.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권1호
    • /
    • pp.11-14
    • /
    • 2018
  • High Temperature Superconducting (HTS) power cables are capable of transmitting bulk power without any loss compared to conventional copper cables. The major challenge in the design of such HTS cables is the high stresses (electro-thermal/electro-mechanical) developed at high voltages, high currents and cryogenic temperatures. The safe and reliable operation of HTS cables involves lots of instrumentation for monitoring, measurement, control and safe operation. In principle, a four probe method for resistance (RTD PT-100) is used for temperature measurements at various locations of HTS cable. The number of connecting leads required for this is four times that of the number of sensors. The present paper discusses a novel way of connecting 128 RTD sensors with the help of only 14 leads using a cold electronics based multiplexer board. LabVIEW 11.0 software was used for interfacing and displaying the readings of all the sensors on computer screen.