• Title/Summary/Keyword: RSD

Search Result 528, Processing Time 0.028 seconds

Testing LCDM with eBOSS / SDSS

  • Keeley, Ryan E.;Shafieloo, Arman;Zhao, Gong-bo;Koo, Hanwool
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.47.3-47.3
    • /
    • 2021
  • In this talk I will review recent progress that the SDSS-IV / eBOSS collaboration has made in constraining cosmology from the clustering of galaxies, quasars and the Lyman-alpha forest. The SDSS-IV / eBOSS collaboration has measured the baryon acoustic oscillation (BAO) and redshift space distortion (RSD) features in the correlation function in redshift bins from z~0.15 to z~2.33. These features constitute measurements of angular diameter distances, Hubble distances, and growth rate measurements. A number of consistency tests have been performed between the BAO and RSD datasets and additional cosmological datasets such as the Planck cosmic microwave background constraints, the Pantheon Type Ia supernova compilation, and the weak lensing results from the Dark Energy Survey. Taken together, these joint constraints all point to a broad consistency with the standard model of cosmology LCDM + GR, though they remain in tension with local measurements of the Hubble parameter.

  • PDF

Development of an UPLC-DAD Method for Simultaneous Analysis of Eight Marker Compounds of Bulhwangeumjeonggi-san (UPLC-DAD를 이용한 불환금정기산의 다성분 동시분석법 개발)

  • Lee, Kyung-hee;Lamichhane, Ramakanta;Kumar, Sharma Dipak;Raj, Pandeya Prakash;Kim, Se-Gun;Jung, Hyun-Ju
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.4
    • /
    • pp.366-373
    • /
    • 2016
  • Bulhwangeumjeonggisan (BHGJGS) is a traditional herbal formulation generally used in the treatment of cold and gastritis. BHGJGS consists of eight herbal plants; Atractylodis Rhizoma, Magnoliae Cortex, Citri Pericarpium, Glycyrrhizae Radix, Agastachis Herba, Pinelliae Rhizoma, Zingiberis Rhizoma and Zizyphi Fructus. Complete standardization of this formulation has not been done yet. So, a simple and accurate method was developed and validated using Ultra Performance Liquid Chromatography (UPLC) with Diode Array Detector (DAD) for the standardization of BHGJGS. UPLC conditions were optimized using a c18 RP-Amide column with mobile phase; 0.1% phosphate buffer and acetonitrile, detection wavelength; 210 and 325 nm. The linearities of calibration curves were acceptable ($R^2$>0.9994), and the limit of detection and quantification were within the ranges of 0.011-0.091 and $0.034-0.277{\mu}g/ml$ respectively. The relative standard deviation (RSD) of intra- and inter-day precisions were under 3.61%. The RSD of repeatability was under 0.68 %. The results of recovery test were 94.4-107.9%, and the RSD were under 4.6%. The developed method was used to find the contents of standard constituents in BHGJGS mix extract powder, and two commercial formulation (A and B). The data show that the developed method was specific, sensitive, accurate, and precise for analysis of BHGJGS components.

Pain Control by Spinal Cord Stimulation in the Reflex Sympathetic Dystrophy -A case report- (반사성 교감신경성 위축증 환자에서 척수 자극기를 이용한 통증관리 -증례 보고-)

  • Lee, Sang-Chul;Kim, Jin-Hee;Hwang, Jung-Won;Han, Mi-Ae;Kim, Seong-Deok;Kim, Kye-Min;Lee, Byeong-Geon
    • The Korean Journal of Pain
    • /
    • v.10 no.1
    • /
    • pp.86-88
    • /
    • 1997
  • Regional sympathetic blockade is the most effective treatment for reflex sympathetic dystrophy (RSD). Radiofrequency thermocoagulation provides longer duration of pain relief than local anesthetics and less complication than chemical neurolytic agents for lumbar sympathectomy. Spinal cord stimulation (SCS) is thought to be an effective modality yieding good results in treating intractable neuropathic pain. Therefore RSD might be a good indication for SCS. We treated a patient with RSD who responded well to lumbar sympathetic blockade (LSB) with radiofrequency thermocoagulation and SCS. The patient had a left ankle sprain requiring a case for the lower leg for 2 weeks. The patient suffered increasing pain and swelling on the lower part of that leg. We thought to block the lumbar sympathetic chain utillzing radiofrequency thermocoagulation 2 days after LSB with local anesthetics. The results provided accepatable pain relief (VAS $8{\rightarrow}15$) but the patient still could not walk due to remaining pain which was further aggravated by walking. After SCS, pain relief improved (VAS $5{\rightarrow}13$) and patient could walk without assistance.

  • PDF

Multiphasic Analysis of Growth Curve of Body Weight in Mice

  • Kurnianto, E.;Shinjo, A.;Suga, D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.3
    • /
    • pp.331-335
    • /
    • 1999
  • The present study describes the analysis of the multiphasic growth function (MGF) to body weight in laboratory and wild mice. Three genetic groups of laboratory mice (Mus musculus domesticus) designated $CF_{{\sharp}1}$, C3H/HeNCrj and C57BL/6NCrj, and a genetic group of Yonakuni wild mice (Mus musculus molossinus yonakuni, Yk) were used. Mean body weights of each genetic group-sex subclass from birth to 69 days of age taken at 3-day intervals were analyzed by a monophasic, diphasic and triphasic functions for describing growth patterns. A comparison among the three functions of the MGF was based on the goodness-of-fit criteria: residual standard deviation (RSD), adjusted R-square (Adj $R^2$) and Akaike's information criterion (AIC). Result of this study indicated that body weight averaged heavier for males than for females. Among the four genetic groups within both sexes, $CF_{{\sharp}1}$ showed the highest, subsequent followed by C3H/HeNCrj, C57BL/6NCrj and Yk. Comparison among the three functions revealed that the triphasic function was the best fit to growth data, with the lowest RSD, the highest Adj $R^2$ and the lowest AIC, for the four genetic groups. For the triphasic function, RSD within each genetic group-sex subclass was similar for males and females. Adj $R^2$ was 0.999 for all genetic group-sex subclasses. AIC for laboratory mice males and females ranged from -70.48 to 66.50 and from -92.81 to -68.64, respectively; whereas for Yk wild mice males was -74.29 and females -78.42.

Quantitative Analytical Method for Eighteen Marker Compounds in Ongyeong-tang, a Traditional Herbal Formula, Using High-Performance Liquid Chromatography for Quality Assessment

  • Kim, Jung-Hoon;Shin, Hyeun-Kyoo;Seo, Chang-Seob
    • The Korea Journal of Herbology
    • /
    • v.30 no.4
    • /
    • pp.11-20
    • /
    • 2015
  • Objectives : Ongyeong-tang (OGT) is a traditional herbal formula used to cure gynaecological disorders. OGT consists of 12 herbal medicines containing various bioactive components. Therefore, the development of suitable analytical method for the marker compounds is necessary for the quality control of OGT. Methods : Determination of the 18 marker compounds in OGT preparations was quantitatively performed by high-performance liquid chromatography-photodiode array detection analysis. The marker compounds were separated on a reversed-phase C 18 column and the analytical method was successfully validated, which was applied to compare OGT extracts from laboratory preparation and commercial OGT granules. Results : Limit of detection and limit of quantification values were in the ranges of $0.001-0.016{\mu}g/mL$ and $0.003-0.047{\mu}g/mL$, respectively. Precision was 0.03-3.71 % within a day and 0.03-3.81 % over four consecutive days. Recovery of marker compounds ranged from 90.63-108.26 %, with relative standard deviation (RSD) values < 4.0 %. Reproducibility was < 2.5 % of the RSD value. The 18 marker compounds were stable within 16 h at $10^{\circ}C$, with the RSD value < 3.5 %. Quantitative analysis results showed that the quantities of the 18 marker compounds varied among OGT samples. Pearson coefficient evaluation and principal component analysis demonstrated that an OGT water extract produced by a laboratory method clearly differed from commercial OGT granules. Conclusions : The developed analytical method was simple, precise, and reliable. Therefore, it can be used for the quality assessment of OGT preparations.

Signal compensation by the light scattering of sample aerosols in ICP-AES (ICP-AES에서 에어로졸의 광산란에 의한 신호의 보정)

  • Yeon, Pyung-Hum;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.223-229
    • /
    • 2012
  • Analytical signal from ICP was compensated by the light scattering of sample aerosols. Reference scattering signal was generated by a He-Ne or diode laser, monitored for the amount of aerosol producing and used for the compensation of analytical signals. The result showed that significant improvement in precision could be achieved for the short-term signal (within 1 minute) from 3.4% to 0.9% RSD in signal and 14.9% to 4.2% for the long-term (10 minutes) for Be, Pb and Co. This method is very useful not only for the pulse type but for continuous type signals especially when a nebulizer is unstable. To improve long-term precision, higher stability is required in the scattering cell and detector as well as the reduction of noise from the line between a nebulizer and plasma.

The Evaluation and Fabrication of Radiation Phosphor Screen for Non-destructive Testing using the Special Room Temperature Gel-printing Method (상온 겔프린팅 기법을 이용한 비파괴 검사용 방사선 증감지 제작 및 평가)

  • Lee, Jun Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.391-396
    • /
    • 2020
  • In this study, we developed a phosphor film screen that can be applied to radiographs during non-destructive testing using Gd2O2S:Tb phosphor compounds. The image uniformity of the fabricated phosphor screen film was analyzed by FE-SEM, RMS and RDS analysis. In addition, the tensile strength, elongation, and modulus of elasticity of the Gd2O2S:Tb phosphor screen were evaluated by measuring the stress-strain characteristic curve. As a result, it was evaluated that the RSD value had an excellent image uniformity within 10% of the evaluation criteria. In addition, as a result of evaluation of physical properties, the tensile strength was 1.1760 N/㎟, the tensile strength at break was 1.1515 N/㎟. These results suggest that the Gd2O2S:Tb phosphor screen fabricated using the room temperature gel-printing method could be applied to digital radiography detectors for radiography.

Preparation of Metal-p-aminobenzyl-DOTA Complex Using Magnetic Particles for Bio-tagging in Laser Ablation ICP-MS

  • Yoon, S.Y.;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3665-3670
    • /
    • 2012
  • Metal-p-$NH_2$-Bn-DOTA (paraammionobenzyl-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid: ABDOTA) complex was synthesized and purified for bio-tagging to quantify biological target materials using laser ablation (LA)-ICP-MS. Since the preparation of a pure and stable tagging complex is the key procedure for quantification, magnetic particles were used to purify the synthesized metal-ABDOTA complex. The magnetic particles immobilized with the complex attracted to a permanent magnet, resulting in fast separation from free un-reacted metal ions in solution. Gd ions formed the metal-complex with a higher yield of 64.3% (${\pm}3.9%$ relative standard deviation (RSD)) than Y ions, 52.3% (${\pm}2.5%$ RSD), in the pH range 4-7. The complex bound to the magnetic particles was released by treatment with a strong base, of which the recovery was 81.7%. As a reference, a solid phase extraction (SPE) column packed with Chelex-100 resin was employed for separation under similar conditions and produced comparable results. The tagging technique complemented polydimethylsiloxane (PDMS) microarray chip sampling in LA-ICP-MS, allowing determination of small sample volumes at high throughputs. For application, immunoglobulin G (IgG) was immobilized on the pillars of PDMS microarray chips and then tagged with the prepared Gd complex. IgG could then be determined through measurement of Gd by LA-ICP-MS. A detection limit of 1.61 ng/mL (${\pm}0.75%$ RSD) for Gd was obtained.

Development of Jaspine B analysis using LC-MS/MS and its application: Dose-independent pharmacokinetics of Jaspine B in rats

  • Song, Im-Sook;Jeon, Ji-Hyeon;Lee, Jihoon;Lim, Dong Yu;Lee, Chul Haeng;Lee, Dongjoo;Choi, Min-Koo
    • Analytical Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.37-45
    • /
    • 2021
  • A rapid and simple LC-MS/MS analytical method in determining Jaspine B has been developed and validated in rat plasma. The standard curve value was 25 - 5000 ng/mL and the linearity, inter-day and intra-day accuracy and precision were within 15.0 % of relative standard deviation (RSD). The mean recoveries of Jaspine B ranged from 87.5 % to 91.2 % with less than 3.70 % RSD and the matrix effects ranged from 91.1 % to 108.2 % with less than 2.6 % RSD. The validated LC-MS/MS analytical method of Jaspine B was successfully applied to investigate the dose-escalated pharmacokinetic study of Jaspine B in rats following an intravenous injection of Jaspine B at a dose range of 1 - 10 mg/kg. The initial plasma concentrations and area under plasma concentration curves showed a good correlation with intravenous Jaspine B dose, indicating the dose independent pharmacokinetics of Jaspine B in rats. In conclusion, this analytical method for Jaspine B can be easily applied in the bioanalysis and pharmacokinetic studies of Jaspine B, including its administration at multiple therapeutic doses, or for making pharmacokinetic comparisons for the oral formulations of Jaspine B in small experimental animals as well as in vivo pharmacokinetic-pharmacodynamic correlation studies.

Feasibility study of CdZnTe and CdZnTeSe based high energy X-ray detector using linear accelerator

  • Beomjun Park;Juyoung Ko;Jangwon Byun;Byungdo Park ;Man-Jong Lee ;Jeongho Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2797-2801
    • /
    • 2023
  • CdZnTeSe (CZTS) has attracted attention for applications in X- and gamma-ray detectors owing to its improved properties compared to those of CdZnTe (CZT). In this study, we grew and processed single crystals of CZT and CZTS using the Bridgeman method to confirm the feasibility of using a dosimeter for high-energy X-rays in radiotherapy. We evaluated their linearity and precision using the coefficient of determination (R2) and relative standard deviation (RSD). CZTS showed sufficient RSD values lower than 1.5% of the standard for X-ray dosimetry, whereas CZT's RSD values increased dramatically under some conditions. CZTS exhibited an R2 value of 0.9968 at 500 V/cm, whereas CZT has an R2 value of 0.9373 under the same conditions. The X-ray response of CZTS maintains its pulse shape at various dose rates, and its properties are improved by adding selenium to the CdTe matrix to lower the defect density and sub-grain boundaries. Thus, we validated that CZTS shows a better response than CZT to high-energy X-rays used for radiotherapy. Further, the applicability of an onboard imager, a high-energy X-ray (>6 MV) image, is presented. The proposed methodology and results can guide future advances in X-ray dose detection.