Browse > Article
http://dx.doi.org/10.7742/jksr.2020.14.4.391

The Evaluation and Fabrication of Radiation Phosphor Screen for Non-destructive Testing using the Special Room Temperature Gel-printing Method  

Lee, Jun Haeng (Department of Radiology of Nambu University)
Publication Information
Journal of the Korean Society of Radiology / v.14, no.4, 2020 , pp. 391-396 More about this Journal
Abstract
In this study, we developed a phosphor film screen that can be applied to radiographs during non-destructive testing using Gd2O2S:Tb phosphor compounds. The image uniformity of the fabricated phosphor screen film was analyzed by FE-SEM, RMS and RDS analysis. In addition, the tensile strength, elongation, and modulus of elasticity of the Gd2O2S:Tb phosphor screen were evaluated by measuring the stress-strain characteristic curve. As a result, it was evaluated that the RSD value had an excellent image uniformity within 10% of the evaluation criteria. In addition, as a result of evaluation of physical properties, the tensile strength was 1.1760 N/㎟, the tensile strength at break was 1.1515 N/㎟. These results suggest that the Gd2O2S:Tb phosphor screen fabricated using the room temperature gel-printing method could be applied to digital radiography detectors for radiography.
Keywords
$Gd_2O_2S:Tb$; NDT; SEM; RMS; RSD;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Occupational health 313, "Cancer prevention management of radiation nondestructive examination worker", Vol. 2, pp 38. Korea Industrial Health Association 2014.
2 Occupational health 350. "Repeated Radiation Overexposure in Non-Destructive Examiners and Disease outbreak at worker", Korea Industrial Health Association 2017.
3 J. K. Park, S. W. Yang, J. H. Jeon, J. H. Kim, Y. J. Heo, S. S. Kang, K. T. Kim "Fabrication of Bendable Gd2O2S Intensifying Screen and Evaluation of Fatigue Properties", Journal of the Korean Society of Radiology, Vol. 11, No. 7, pp. 611-617, 2017. http://dx.doi.org/10.7742/jksr.2017.11.7.611   DOI
4 T. Istvan and V. Katalin, "Radiation Accidents: Occurrence, Types, Consequences, Medical Management, an d the Lessons to be Learned", Central European Journal of Occupational and Environmental Medicine, Vol. 7, No. 1, pp. 3-14, 2001.
5 K. J. Lee, J. I. Yun, B. G. Park, S. Kim, B. S. Lee, "Evaluation of luminance performance of scintillating film for monitoring the position of a radioactive source in an NDT apparatus", Journal of Radiological Science and Technology, Vol. 28, No. 1, pp. 13-17, 2005.
6 K. T. Kim, J, H, Kim, M, J, Han, Y, J, Heo, K, J, Ahn, S. K. Park "The Study on Design of Semiconductor Detector for Checking the Position of a Radioactive Source in an NDT", Journal of the Korean Society of Radiology, Vol. 11, No. 3, June 2017. https://doi.org/10.7742/jksr.2017.11.3.171
7 Occupational health 312, "Cancer prevention management of radiation nondestructive examination worker", Vol. 1, pp 45. Korea Industrial Health Association 2014.
8 KINS/HR-977 Final Research Report, "Evaluation of Exposure Radiation by Work of Non-destructive Testing Workers", Korean Industrial Testing CO. Ltd 2009.
9 Occupational health 309, "Development of Non-destructive Testing Radiation Exposure Reduction Plan", pp 68-70. Korea Industrial Health Association 2014.