• Title/Summary/Keyword: RS485 Communication

Search Result 109, Processing Time 0.034 seconds

Development of DSP-based Modbus Communication Scheme and Control Module for Controlling Actuators in Industrial Equipment (산업용 장비에서의 액추에이터를 제어 하기 위한 DSP에서의 Modbus통신 구현과 제어 모듈 개발)

  • Kim, Won-Jun;Gwak, Dong-Gi;Kim, Dong Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1109-1117
    • /
    • 2017
  • In this work, a new control module and communication system associated with DSP are proposed to overcome the limitations of the contemporary prevailing PLC-based industrial equipment controller, and the performance of the proposed system was experimentally verified. In the light of this issue, a communication conversion scheme from RS-485 to Modbus, the dominant communication protocol used by PLC, was developed and shown to yield enhanced compatibility between devices. The proposed system allows for ~50% cost reduction as well as downsizing of the industrial controllers. Furthermore, the design includes 24 V general digital I/O pins, which facilitate partial expansion of inputs and outputs. With Modbus communication implemented in DSP with the RS-485 interface, multi-to-multi communication may also be achieved.

Internet Based Remote Control and Monitoring for Motor (인터넷기반 모터 원격제어 및 모니터링)

  • Kang, Shin-Young;Kim, Eun-Ju;Wi, Seog-Oh;Kim, Gwang-Heon;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.7
    • /
    • pp.279-285
    • /
    • 2002
  • This Paper deals with the economical equipment control which is used by internet network system at the industrial workplace. If the control devices can be accessed by internet, we can have the developed possibility of work conditions. in this paper, we presented the advanced digital timer which has a communication function to control and observe panel to realize control solution based on internet to be easily applicable at workplace with low cost, and we used RS-485 serial communication module to have parallel expansibility and safety. And, this system was experimented and designed for easy system management and status check from remote station through internet. As the result for experiment, the circuit configuration would be more simplified than the existing, and it is expected that multi connection control and monitoring can be simply implemented with low cost equipment at industrial workplace.

Vacuum Gauge Control System Using MSCC for PLS (MSCC를 이용한 가속기 진공장치 감시 시스템 개발)

  • Yoon, J.C.;Lee, T.Y.;Hang, J.Y.;Nam, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2169-2171
    • /
    • 2001
  • The vacuum gauge control system has been designed and implemented using multi-serial communication controllers (MSCC) for the 2.5 Gev storage ring at the Pohang Accelerator Laboratory (PAL). There are 20 Balzers vacuum gauges and 17 Granville-Phillips vacuum gauges at the storage ring. A MSCC have two RS485 (max speed 460.8Kbps) field network port, 8 channel serial communication ports (max speed 460.8Kbps) connected to gauge controller for serial communication control. 12 MSCCs are connected to a personal computer (PC) through the RS485 field network. The PC can automatically control the MSCCs by sending set of commands through the network. The commands specify the duration of the MODBUS protocol. Upon receiving a command from a PC running under Windows2000 through the network, the MSCC communicate through the serial output ports to gauge controller. In this paper, we describe control structure and scheme of the vacuum gauge control system.

  • PDF

Cause Analysis and Improvement of Signal Interference in Byteflight Data Bus

  • Kwon, Jung-Hyuk;Tak, Su-Pyeong;Kwon, Ik-Hyun;Lee, Wang-Sang
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.6
    • /
    • pp.50-58
    • /
    • 2021
  • Byteflight is developed based on RS-485 communication (an international standard), and it can be used as a data bus during the operation of an integrated avionics system in the latest aircraft. Therefore, the integrated avionics system can perform an effective and safe flight mission only when the accurate and seamless display of flight information, communication, and accurate functions of navigation are implemented. In this study, cause analysis and failure investigation were performed on screen abnormalities and communication interruptions due to signal interference in the Byteflight data bus of the integrated avionics system during aircraft operation. To improve signal interference between avionics units, the branch point and wiring path of the Byteflight data bus were changed, and the verification result of the improved method was also described.

Development of Multi-channels NMEA0183 Indicator System (다채널 NMEA0183 인디케이트 시스템 개발)

  • Kim, Gwan-Hyung;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.11
    • /
    • pp.2327-2332
    • /
    • 2011
  • Recently, the increase of loading amount on cargo ships due to the automation of loading process results in much complex ship operation. For this reason, NMEA-0183 based on RS-422,485 and NMEA-2000 based on CAN communication methods have been usually used as a standardized method in the marin electric interfacing equipments. In this paper, a general NMEA-0183 protocol was designed to support 7-channel NMEA-0183 serial communication data, which can receive 3-channel 16 bits ADC and 2-channel pulse using SPI(Serial Peripheral Interface). In particular, this method was designed for ship communication requires 7 important factors. Also in this study, using the minimization of the proposed method and realizing the monitoring system based on PC, the effectiveness of multichannel indicator system was proposed.

Redundant Operation of a Parallel AC to DC Converter via a Serial Communication Bus

  • Kanthaphayao, Yutthana;Kamnarn, Uthen;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.533-541
    • /
    • 2011
  • The redundant operation of a parallel AC to DC converter via a serial communication bus is presented. The proposed system consists of three isolated CUK power factor correction modules. The controller for each converter is a dsPIC30F6010 microcontroller while a RS485 communication bus and the clock signal are used for synchronizing the data communication. The control strategy of the redundant operation relies on the communication of information among each of the modules, which communicate via a RS485 serial bus. This information is received from the communication checks of the converter module connected to the system to share the load current. Performance evaluations were conducted through experimentation on a three-module parallel-connected prototype, with a 578W load and a -48V dc output voltage. The proposed system has achieved the following: the current sharing is quite good, both the transient response and the steady state. The converter modules can perform the current sharing immediately, when a fault is found in another converter module. In addition, the transient response occurs in the system, and the output voltages are at their minimum overshoot and undershoot. Finally, the proposed system has a relatively simple implementation for the redundant operation.

Developmetn of Integrated Monitoring System for Composition of CIM System's infrastructure(DLU & DAU) (l) (CIM 시스템의 Infrastructure(DLU & DAU) 구성을 위한 통합 모니터링 시스템의 개발(I))

  • Kang, H.W.;Lee, W.;Kim, S.B.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.10
    • /
    • pp.18-24
    • /
    • 1995
  • This paper describes a multi-computer system developed for CIM(Computer Integrated Manufacturing) system, which combines single board computers and personal computers by using RS422/485 communication and LAN. The system adopts a concept of hot run back up system based on dual CUP system of host and supervisor structure. The dual CPU system and the single board computer are respectively developed using 32 bits microcomputer and 16 bits microprocessor. 8097BH. The multi communication between two types of system is done by using RS 422/485, and also data logging computers are linked with LAN.

  • PDF

A study on the implementation of digital anti-fire monitoring system with multipoint communication protocol (다중포인트 통신 프로토콜을 지원하는 디지털 화재 방지 모니터링 시스템 구현에 관한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1423-1428
    • /
    • 2012
  • In this paper, we investigated an implementation of anti-fire monitoring system based on the RS-485 communication to support local area coverage within a range of 1 Km range. We developed a Multi Point Communication Protocol supporting input/output information processing and control up to 8128 terminal check points, which provides an interface between the anti-fire monitoring system receiver and multiplex transponders. Additionally, a multiplex transponders controller has been designed for the implemented system to comply with the government regulation on fire protection, especially to monitor, report and control 1016 terminal check points within the time limit.

A Design of Gateway for Industrial Communication (산업용 통신 게이트웨이 설계)

  • Eum, Sang-hee;Lee, Byong-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.281-283
    • /
    • 2016
  • Recently, many industrial instruments face the problem of protocol compatibility with the external monitoring and control system. This paper is prepared in the main control board to support the industrial communication protocol conversion, control, and monitoring. The industrial communication gateway module is also designed to ensure that the protocol conversion of CAN bus and Ethernet. The main board processor is used the Atmega2560, and placed 4ea RS485 serial slots for sub-board. One of them is used for communication CAN bus and Ethernet. It provides analog and digital I / O through each of the slots is used for control and monitoring.

  • PDF

Chaos Based Random Number Generation In Tiny MCU (소형마이콤에서의 카오스난수 발생 함수구현)

  • Hyun, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.3
    • /
    • pp.1-4
    • /
    • 2010
  • RS-485, communication bases from small network system must prepare in collision. The collision is that mean the data transfer breaks. For a stabilized communication chooses 1:N polling methods. But polling is low speed in addition to maybe overload Master device. So, usual N:N Prefers a communication. In this case, must be preparing to avoid collision or some solutions. Generally, to after collision retransmits after short time. It's called delay time for short time. When making a delay time, uses address of each systems. (Address of each node) If the many nodes collided, the each node has different delay time. When making a delay time, uses a usual random number. Making a random number is hard job. So uses a usual pseudorandom number. It is more difficult from small size MCU. The Chaos random number provides stabled value. Finally, when uses the Chaos random number, the stability and reliability of system get better.