• Title/Summary/Keyword: RPM 신호

Search Result 61, Processing Time 0.032 seconds

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF

Active control of pump noise of dishwashers using FxLMS algorithm (FxLMS 알고리듬 기법을 이용한 식기 세척기의 펌프 소음 능동 제어)

  • Tark, Un-su;Oh, Han-Eum;Hong, Chinsuk;Jeong, Weui-Bong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.46-54
    • /
    • 2021
  • In this paper, active noise control was performed to reduce radiated noise in the low frequency band of dishwashers. First, through an analysis of the noise environment of the dishwasher, it was confirmed that the pump noise contributed the most to the radiated noise in the low frequency band, From the result of the noise environment analysis, the reference signal was selected to be the vibration signal of the pump body. The reference signal was obtained by using the accelerometer on the pump body, which can prevent acoustic feedback. The error signal sensor was selected as a microphone located at 1 m in front of the dishwasher and 0.5 m in height. And to design the controller, the error signal and the reference signal were measured at the operational rpms of the dishwasher at 2,500 rpm, 2,600 rpm and 2,800 rpm, and the secondary path transfer function was measured. The designed controller was mounted on Digital Signal Processor (DSP) equipment, and the control performance was verified experimentally. As a result of the measurement at the 3 operational rpms, the 7th multiple component of pump operating frequency decreased by 1.93 dB, 4.43 dB, 5.15 dB per rpm, and the 12th multiple component decreased by 6.67 dB, 2.34 dB, 4.28 dB per rpm. And overall Sound Pressure Level (SPL) decreased by 0.84 dB, 2.58 dB, 1.48 dB by rpm.

A Study on Vibration Measurement Using LabVIEW and Acceleration Sensor (LabVIEW와 가속도 센서를 이용한 진동신호 측정에 관한 연구)

  • Park, Jiye;Moon, Chae-Joo;Kim, Tae-Gon;Jeong, Moon-Seon
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.129-130
    • /
    • 2012
  • 본 논문에서는 3축 가속도 센서의 부착 방법과 위치에 따른 진동 신호의 주파수 특성을 분석하였다. 날개 하나가 깨진 환풍기를 철제 기둥에 나사로 고정하고 회전수를 50rpm, 1710rpm, 2400rpm으로 각기 달리하여 진동을 발생 시켜 가속도 센서의 부착 방법과 위치에 따른 진동 신호를 측정하고 비교하였다. 3축 가속도 센서를 측정하기 위한 측정 소프트웨어를 설계 제작하였으며, 센서의 진동을 비교한 결과 실험에 사용된 회전수에서는 각각의 부착 방법보다는 부착 위치에 따른 진동의 차이가 있는 것으로 나타났다.

  • PDF

The Analysis of High Frequency Signal for 7tonf-class Power Pack System of KSLV-II (한국형발사체 7톤 파워팩 시스템 고주파 신호 분석)

  • So, Younseok;Yi, Seungjae;Lee, Kwangjin;Kim, Seunghan;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.3
    • /
    • pp.96-102
    • /
    • 2016
  • The 7tonf-class power pack test at turbopump test facility in Naro space center was performed for confirmations of starting/running/ending operation characteristics before 7tonf rocket engine hot-firing test. The dynamic pressure mounted on a combustion chamber of gas generator is measured under 0.2 bar which does not conditioned to the unstable combustion. The analysis results of RPM and acceleration sensors mounted on the turbopump, the power pack test was performed to the estimated RPM with the stable combustion.

Exhaust Noise Control with the Active Muffler in Exhaust System of Vehicle (상용차 배기계에서 액티브 머플러를 이용한 배기 소음 제어)

  • 김홍섭;홍진석;오재응;송진호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.36-42
    • /
    • 1998
  • In this study, active muffler was designed and was manufactured for exhaust noise reduction of commercial vehicle, then experiment of real vehicle was conducted. In a manufactured active muffler, because the flow of exhaust noise in tail pope outlet are become a plane wave, the global reduction if radiation noise from outlet and the placement of error microphone to avoid the exhaust gas of high temperature could be implemented. In control algorithm, reduction of noise of engine driving frequency and harmonic frequency can be archieved using proposed reference signal including a fixed speed state(2,000rpm, 3,000rpm, 4,000rpm) and a run-up speed state(2,000rpm$\rightarrow$4,000rpm) is accomplished with the active muffler installed in vehicle.

  • PDF

Speed Control of High Speed Miniature BLDCM Based on Software PLL (소프트웨어 PLL 기반 소형 고속 BLDCM의 속도 제어)

  • Lee, Bong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.112-119
    • /
    • 2009
  • This paper presents a PLL(Phase Lock Loop) approach for effective speed and torque control of high speed miniature BLDCM(Brushless DC Motor) using hall sensor. The proposed speed control method based on PLL uses only a phase shift between reference pulse signal according to speed reference and actual pulse signal from hall sensor. It doesn't use any speed calculation, and calculates a direct current reference from phase shift. The current reference is changed to reduce the phase shift between reference and actual pulse. So the actual speed can keep the reference speed. The proposed control scheme is very simple but effective speed control is possible. In order to obtain a smooth torque production, the reference current is changed using acceleration and deceleration slope. The proposed control scheme is verified by experimental results of the 50W, 40,000[rpm] high speed miniature BLDCM.

Noise Attenuation Effect According to the Direction of Canceling Speaker in Duct-acoustic System (덕트-음향 시스템에서 소거용스피커 방향에 따른 소음감소효과)

  • Lee, Hyung-Seok;Lee, Eung-Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.51-57
    • /
    • 2009
  • In this paper, we studied on an attenuation effect of automobile exhaust noise according to the direction of canceling speaker in duct-acoustic ANC system. Automobile exhaust noise was recorded at 800rpm, 3500rpm and 5000rpm of a diesel engine. Directions of canceling speaker can be set to $30^{\circ}$, $90^{\circ}$ and $150^{\circ}$ against the primary noise flow by acrylic ducts to be made for the experimentation. DSP board used to control the ANC system. The algorithm of this ANC system applied the Filtered-x-LMS algorithm that is modified to compensate for a property of DSP input signal and the secondary-path effect. As an experiment result, the direction of canceling speaker was proved to influence the reduction effect of noise. The $150^{\circ}$ duct in the attenuation effect of noise showed a better result than the $90^{\circ}$ or $30^{\circ}$ duct.

Noise Attenuation Effect According to the Direction of Secondary Sound Source in Duct ANC System (Duct ANC System에서 부가음원 방향별 소음감소효과)

  • Lee, Eung-Suk;Lee, Hyung-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.3
    • /
    • pp.251-260
    • /
    • 2009
  • In this paper, we studied on an attenuation effect of automobile exhaust noise according to the direction of canceling speaker in ANC system. Automobile exhaust noise was recorded at 800 rpm, 3500 rpm and 5000 rpm of a diesel engine. Directions of canceling speaker can be set to $30^{\circ}$, $90^{\circ}$ and $150^{\circ}$ against the primary noise flow by acrylic ducts to be made for the experimentation. DSP board with TMS320C6416 chip of Texas Instrument Co. used to control the ANC system. The algorithm of this ANC system applied the Filtered-x-LMS algorithm that is modified to compensate for a property of DSP input signal and the secondary-path effect. As an experiment result, the direction of canceling speaker was proved to influence the reduction effect of noise. The $150^{\circ}$ duct in the attenuation effect of noise showed a better result than the $90^{\circ}$ or $30^{\circ}$ duct.

Development of a device to measure the speed of motor used in a crane (기중기에 사용된 모터의 회전수 측정장치 개발)

  • 김강철;한석붕
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.374-377
    • /
    • 2001
  • 본 논문에서는 기중기에 사용된 모터의 회전수를 측정하는 정치를 설계하였다. 이 장치는 로타리엔코더, 회전수를 계산하는 속도 측정부, LCD 표시부 및 모터의 방향판별회로로 구성된다. 모터의 회전수측정 장치는 모터의 회전수를 측정하여 RPM으로 표시하고, 모터가 6° 회전 후에 모터의 방향을 판별할 수 있다. 그리고 모터가 제한속도를 벗어나면 위험신호를 발생하는 신호와 회전방향을 나타내는 신호를 발생한다.

Respiratory signal analysis of liver cancer patients with respiratory-gated radiation therapy (간암 호흡동조 방사선치료 환자의 호흡신호분석)

  • Kang, dong im;Jung, sang hoon;Kim, chul jong;Park, hee chul;Choi, byung ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Purpose : External markers respiratory movement measuring device (RPM; Real-time Position Management, Varian Medical System, USA) Liver Cancer Radiation Therapy Respiratory gated with respiratory signal with irradiation time and the actual research by analyzing the respiratory phase with the breathing motion measurement device respiratory tuning evaluate the accuracy of radiation therapy Materials and Methods : May-September 2014 Novalis Tx. (Varian Medical System, USA) and liver cancer radiotherapy using respiratory gated RPM (Duty Cycle 20%, Gating window 40% ~ 60%) of 16 patients who underwent total when recording the analyzed respiratory movement. After the breathing motion of the external markers recorded on the RPM was reconstructed by breathing through the acts phase analysis, for Beam-on Time and Duty Cycle recorded by using the reconstructed phase breathing breathing with RPM gated the prediction accuracy of the radiation treatment analysis and analyzed the correlation between prediction accuracy and Duty Cycle in accordance with the reproducibility of the respiratory movement. Results : Treatment of 16 patients with respiratory cycle during the actual treatment plan was analyzed with an average difference -0.03 seconds (range -0.50 seconds to 0.09 seconds) could not be confirmed statistically significant difference between the two breathing (p = 0.472). The average respiratory period when treatment is 4.02 sec (${\pm}0.71sec$), the average value of the respiratory cycle of the treatment was characterized by a standard deviation 7.43% (range 2.57 to 19.20%). Duty Cycle is that the actual average 16.05% (range 13.78 to 17.41%), average 56.05 got through the acts of the show and then analyzed% (range 39.23 to 75.10%) is planned in respiratory research phase (40% to 60%) in was confirmed. The investigation on the correlation between the ratio Duty Cycle and planned respiratory phase and the standard deviation of the respiratory cycle was analyzed in each -0.156 (p = 0.282) and -0.385 (p = 0.070). Conclusion : This study is to analyze the acts after the breathing motion of the external markers recorded during the actual treatment was confirmed in a reproducible ratios of actual treatment of breathing motion during treatment, and Duty Cycle, planned respiratory gated window. Minimizing an error of the treatment plan using 4DCT and enhance the respiratory training and respiratory signal monitoring for effective treatment it is determined to be necessary.

  • PDF