• Title/Summary/Keyword: ROM data

Search Result 377, Processing Time 0.03 seconds

The Design of Algorithm for Saving the Real-time Data Using Microprocessor (원칩마이컴을 이용한 실시간 데이터 저장을 위한 알고리즘 설계)

  • Shin Sa-Hyun;Kim Ki-Bum;Cho Geum-Bae;Baek Hyung-Lae;Seo Jin-Youn;Choi Nak-Il
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.657-661
    • /
    • 2001
  • In This paper describes on the development of detecting power using Microprocessor. The detecting power system is composed of main controller system and analyzing software. Re system detected voltage, current, temperature, leakage current md its saved in ROM. This system applies the 'AT89C52' to CPU and 'AM29F040B' used a memory to sue the data.

  • PDF

Design of WLAN-based A/V System for Multimedia Home Networks (멀티미디어 홈 네트워크 실현을 위한 WLAN 기반의 A/V 전송용 변복조 모뎀 설계)

  • Lee, Youn-Sung;Kim, Hyun-Sik;Wee, Jung-Wook;Paik, Jong-Ho
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.327-330
    • /
    • 2008
  • This paper shows an implementation of WLAN-based Audio/Video(A/V) system for multimedia home networks. Proposed WLAN-based A/V system can transmit multimedia data of high quality. The entire system consists of a 16-bit RISC controller, a program ROM, a SRAM, timers, an interrupt controller, a DART, GPIOs, an I2C and the OFDM modem supporting for the IEEE 802.11g standard. The simple MAC functions are implemented by firmware on an embedded 16-bit RISC controller. The OFDM modem supports a complete set of data rates up to 54Mbps. Proposed the system is implemented by an Altera FPGA EP1S60F1020C6 device, a 10-bit 2-ch DAC, a 10-bit 2-ch ADC and RF/IF chips.

  • PDF

Uninterruptible Power Supply Using Fuzzy Controller (퍼지제어기를 이용한 무정전 전원장치)

  • Kim, D.G.;Park, H.A.;Baek, H.L.;Jung, H.S.;Jung, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.394-396
    • /
    • 1995
  • This paper present fuzzy control technique for the control of output voltage and improvement of UPS wave forms. General UPS has the harmonics in carrier because of output of PWM signal using analog circuit. Output voltage is controlled by selecting PWM data to improve these problems, PWM signal discreted is written on ROM and analog circuit is removed at the system and output voltage is controlled by selecting PWM data by fuzzy controller.

  • PDF

Surgical Outcome of Cervical Arthroplasty Using $Bryan^{(R)}$

  • Kim, Hong-Ki;Kim, Myung-Hyun;Cho, Do-Sang;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.532-537
    • /
    • 2009
  • Objective : Recently, motion preservation has come to the forefront of emerging technologies in spine surgery. This is the important background information of the emergence of cervical arthroplasty as an alternative to arthrodesis that offers the promise of restoring normal spinal movement and reduces a kinematic strain on adjacent segments. The study was designed to evaluate early surgical outcome and radiological effects of $Bryan^{(R)}$ cervical disc prosthesis. Methods : The authors retrospectively reviewed radiographic and clinical outcomes in 52 patients who received the $Bryan^{(R)}$ Cervical Disc prosthesis, for whom follow-up data were available. Static and dynamic radiographs were measured by computer to determine the angles formed by the endplates of the natural disc preoperatively, those formed by the shells of the implanted prosthesis, the angle of functional spine unit (FSU), and the C2-7 Cobb angle. The range of motion (ROM) was also determined radiographically, whereas clinical outcomes were assessed using Odom's criteria, visual analogue pain scale (VAS) and neck disability index (NDI). Results : A total of 71 $Bryan^{(R)}$ disc were placed in 52 patients. A single-level procedure was performed in 36 patients, a two-level procedure in 13 patients, and a three-level procedure in 3. Radiographic and clinical assessments were made preoperatively. Mean follow-up duration was 29.2 months, ranging from 6 to 36 months. All of the patients were satisfied with the surgical results by Odom's criteria, and showed significant improvement by VAS and NDI score (p < 0.05). The postoperative ROM of the implanted level was preserved without significant difference from preoperative ROM of the operated level (p < 0.05). 97% of patients with a preoperative lordotic sagittal orientation of the FSU were able to maintain lordosis. The overall sagittal alignment of the cervical spine was preserved in 88.5% of cases at the final follow up. Interestingly, preoperatively kyphotic FSU resulted in lordotic FSU in 70% of patients during the late follow up, and preoperatively kyphotic overall cervical alignment resulted in lordosis in 66.6% of the patients postoperatively. Conclusion : Arthroplasty using the $Bryan^{(R)}$ disc seemed to be safe and provided encouraging clinical and radiologic outcome in our study. Although the early results are promising, this is a relatively new approach, therefore long-term follow up studies are required to prove its efficacy and its ability to prevent adjacent segment disease.

A Study of TOM(Turn-of-the-Month) Effect in KOSDAQ Market (코스닥시장의 월바뀜(TOM)효과에 관한 연구)

  • Hong, Geon-Pyo;Im, In-Seob;Oh, Hyun-Tak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.308-316
    • /
    • 2015
  • The purpose of this study is to verify TOM(turn-of-the-month) effect in the Kosdaq market, and that to compare to TOM effect of KOSPI for supporting degree of identification and to find new features. For this study, as the study basis sample, we used the daily data of the KOSDAQ from January 1996 to December 2013 and verified the TOM effect through yearly, monthly, classification by event as financial crisis, different period of TOM in order to clarify the effect of the KOSPI and KOSDAQ. As a result, We find that the TOM effect in KOSDAQ is always present uniformly in yearly, monthly, event-specific, which unlike TOM period also in KOSPI and generally TOM effect in KOSDAQ market which has larger volatility was appeared more pronouncedly than KOSPI market, and particularly TOM effect of KOSDAQ was larger than that of KOSPI on financial crisis occasion. But TOM effect of KOSDAQ was less stable than KOSPI.

Assessment of Elderly's Isokinetic Muscle Function, Flexibility and Balance in a Region of Seoul (서울 일부 지역 노인들의 등속성 근기능, 유연성, 균형성 측정 및 평가)

  • Kim, Suk-Won;Sohn, Jee-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.37-44
    • /
    • 2016
  • The aim of the present study was to compare the strength, balance, and flexibility across two age groups (older adults vs. young adults). The isokinetic muscle function, ankle ROM, trunk forward flexibility, stability, and antropometric data for the elderly and 46 university students were collected. The results indicated that male older adults possessed relatively low flexibility (2.97cm) among the groups and showed better stability in the right foot than in the left foot and $35^{\circ}$ of plantar flexion ROM, which was not in the normal range. Their peak strength at the knee joint was below 50% of their counterpart. They revealed a hamstring deficit of 18.55%, ankle eversion deficit of 23.08%, and ankle inversion deficit of 19.19%. The results indicated that female older adults possessed comparable flexibility compared to female young adults. The reciprocal muscle strength ratio of both knees was under 50%, and the deficit was 14.32% (extension) and 19.73% (flexion). The ankle plantar flexion peak torque was approximately 62% (left) and 73% (right) of WS's. The ankle dorsi flexion deficit was 25.05% and the plantar flexion was 26.86%. The eversion deficit was 19.97% and the inversion was 21.09%. These results will be significant in establishing an elderly fitness enhancement program and policy.

The Effect of Taping on Lower Extremity during lump Landing in Subjects with functional Ankle Instability (테이핑이 기능적 발목 불안정성이 있는 선수들의 점프 착지 시 하지에 미치는 영향)

  • Kim, Kyoung-Hun;Cho, Joon-Haeng;Lee, Sung-Cheol
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.265-272
    • /
    • 2009
  • K. H. KIM, J. H. CHO, and S. C. LEE, The Effect of Taping on Lower Extremity during Jump Landing in Subjects with Functional Ankle Instability. Korean Journal of Sport Biomechanics, Vol. 19, No. 2, pp. 265-272, 2009. Ankle taping is thought that it can be very useful in clinical setting for reducing injury. However, the studies of ankle taping is focused only ankle joint. The purpose of this study was to examine the effect of taping on lower extremity during jump landing in subjects with functional ankle instability. we collected the data from VICON. Joint range of motion for sagittal plane, frontal plane and transverse plane were measured during a jump-landing task. Taping used in this study appeared to restrict ankle motion with altering the knee and hip joint ROM. We found ankle taping had effects of reducing PF, initial contact PF in sagittal plane, while increasing knee flexion, hip flexion, intial contact hip flexion statistically. It decreased ankle inversion, knee valgus, initial contact knee valgus, hip abduction in frontal plane and ankle abduction, hip internal rotation in transverse plane statistically. Ankle taping showed significant change Knee and hip joint ROM with ankle joint ROM.

A Randomized Comparative Study of a Standard Anterior Capsular Release versus Inferior Extended Release for the Treatment of Shoulder Stiffness

  • Alzeyadi, Ahmed Abdullah;Kim, Yang-Soo;Lee, Hyo-Jin;Park, Sung-Ryeoll;Sung, Gwang Young;Kim, Dong-Jin;Jung, Ji-Hwan;Kim, Jong-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.117-125
    • /
    • 2017
  • Background: To compare the clinical outcomes of arthroscopic capsular release in patients with and without inferior capsular release for shoulder stiffness. Methods: Between January 2010 and December 2015, 39 patients who underwent arthroscopic capsular release for shoulder stiffness were enrolled and randomized into two groups. In group I, 19 patients underwent arthroscopic capsular release of the rotator interval and anterior capsule. In group II, 20 patients underwent arthroscopic capsular release of the anterior to inferior capsule, including the rotator interval. The American Shoulder and Elbow Surgeons score, Constant scoring system, Simple Shoulder Test, visual analogue scale for pain, and range of motion (ROM) were used for evaluation before surgery, at 3, 6, and 12 months after surgery and on the last follow-up. Results: Preoperative demographic data revealed no significant differences (p>0.05). The average follow-up was 16.07 months. Both groups showed significantly increased ROM at the last follow-up compared with preoperative (p<0.05). At the last follow-up, no statistical differences were found (p>0.05) between groups I and II in functional scores and ROM (forward flexion, p=0.91; side external rotation, p=0.17; abduction external rotation, p=0.72; internal rotation, p=0.61). But we found that group II gained more flexion compared to group I at 3 months and 6 months (p<0.05) after the surgery. Conclusions: Both techniques of capsular release are effective for stiffness shoulder. However, the extended inferior capsular release shows superiority in forward flexion over anterior capsular release alone during 6 months of follows-up (level of evidence: Level I, therapeutic randomized controlled trial).

A Home-Based Remote Rehabilitation System with Motion Recognition for Joint Range of Motion Improvement (관절 가동범위 향상을 위한 원격 모션 인식 재활 시스템)

  • Kim, Kyungah;Chung, Wan-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.3
    • /
    • pp.151-158
    • /
    • 2019
  • Patients with disabilities from various reasons such as disasters, injuries or chronic illness or elderly with limited body motion range due to aging are recommended to participate in rehabilitation programs at hospitals. But typically, it's not as simple for them to commute without help as they have limited access outside of the home. Also, regarding the perspectives of hospitals, having to maintain the workforce and have them take care of the rehabilitation sessions leads them to more expenses in cost aspects. For those reasons, in this paper, a home-based remote rehabilitation system using motion recognition is developed without needing help from others. This system can be executed by a personal computer and a stereo camera at home, the real-time user motion status is monitored using motion recognition feature. The system tracks the joint range of motion(Joint ROM) of particular body parts of users to check the body function improvement. For demonstration, total of 4 subjects with various ages and health conditions participated in this project. Their motion data were collected during all 3 exercise sessions, and each session was repeated 9 times per person and was compared in the results.

The Effect of Shoe Heel Types and Gait Speeds on Knee Joint Angle in Healthy Young Women - A Preliminary Study

  • Chhoeum, Vantha;Wang, Changwon;Jang, Seungwan;Min, Se Dong;Kim, Young;Choi, Min-Hyung
    • Journal of Internet Computing and Services
    • /
    • v.21 no.6
    • /
    • pp.41-50
    • /
    • 2020
  • The consequences of wearing high heels can be different according to the heel height, gait speed, shoe design, heel base area, and shoe size. This study aimed to focus on the knee extension and flexion range of motion (ROM) during gait, which were challenged by wearing five different shoe heel types and two different self-selected gait speeds (comfortable and fast) as experimental conditions. Measurement standards of knee extension and flexion ROM were individually calibrated at the time of heel strike, mid-stance, toe-off, and stance phase based on the 2-minute video recordings of each gait condition. Seven healthy young women (20.7 ± 0.8 years) participated and they were asked to walk on a treadmill wearing the five given shoes at a self-selected comfortable speed (average of 2.4 ± 0.3 km/h) and a fast speed (average of 5.1 ± 0.2 km/h) in a random order. All of the shoes were in size 23.5 cm. Three of the given shoes were 9.0 cm in height, the other two were flat shoes and sneakers. A motion capture software (Kinovea 0.8.27) was used to measure the kinematic data; changes in the knee angles during each gait. During fast speed gait, the knee extension angles at heel strike and mid-stance were significantly decreased in all of the 3 high heels (p<0.05). The results revealed that fast gait speed causes knee flexion angle to significantly increase at toe-off in all five types of shoes. However, there was a significant difference in both the knee flexion and extension angles when the gait in stiletto heels and flat shoes were compared in fast gait condition (p<0.05). This showed that walking fast in high heels leads to abnormal knee ROM and thus can cause damages to the knee joints. The findings in this preliminary study can be a basis for future studies on the kinematic changes in the lower extremity during gait and for the analysis of causes and preventive methods for musculoskeletal injuries related to wearing high heels.