• 제목/요약/키워드: RODS

검색결과 1,122건 처리시간 0.025초

회전 및 굽힘 스프링 기구로 연속 지지된 핵연료봉의 진동연구 (A Study on the Vibration Behavior of the Fuel rods Continuously Supported by a Rotatory and Bent Spring System)

  • 강흥석;송기남;윤경호;정연호;임정식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.454-460
    • /
    • 1998
  • The vibration behavior of fuel rods has been analyzed by FEM in consideration of axial force and support spring constants. The axial compression force on the fuel rod in reactor decreases with the fuel rod burnup, and its decrease makes the natural frequencies of fuel rod considerably increase. The change of support spring constant can contribute to the remarkable change of the mode shapes, but not greatly to the natural frequencies. The reaction forces of support springs are obtained from normalizing the lst mode with the max. 0.2 mm displacement. The calculated reaction forces are larger than the previous results obtained by disregarding the deflections of the support springs.

  • PDF

확공형 마이크로 파일의 강도 평가에 관한 연구 (A Study on the Strength Evaluation of Micropile with Expanded Drill Hole)

  • 이재민;김두환
    • 한국안전학회지
    • /
    • 제29권5호
    • /
    • pp.74-81
    • /
    • 2014
  • This study proposes an advanced type of a micropile system. The proposed micropile system consists of perfobond ribs installed steel rod to improve shear capacity between the thread and the grout, and partially expanded drill holes to increase resistance capacity between the grout and the ground. This study contains experimental evaluations on the proposed micropile system to verify the shear capacity of perfobond rib installed on the steel rod and the load-carrying capacity of shear key created by the partially expanded drill hole. Push-out tests were conducted on a rolled screw thread and steel rods which perfobond ribs are installed instead of rolled screw, in order to compare their load-carrying capacity and behavioral characteristics. As a result, it was confirmed that the perfobond-rib steel rods show much superior structural behavior in terms of initial stiffness, ultimate load, and ductile behavior.

Vibration of axially functionally graded nano rods and beams with a variable nonlocal parameter

  • Aydogdu, Metin;Arda, Mustafa;Filiz, Seckin
    • Advances in nano research
    • /
    • 제6권3호
    • /
    • pp.257-278
    • /
    • 2018
  • Vibration of axially functionally graded nano-rods and beams is investigated. It is assumed that the material properties change along the rod and beam length. The Ritz method with algebraic polynomials is used in the formulation of the problems. Stress gradient elasticity theory is utilized in order to include the nonlocal effects. Frequencies are obtained for different boundary conditions, geometrical and material properties. Nonlocal parameter is assumed as changing linearly or quadratically along the length of the nanostructure. Frequencies are compared to constant nonlocal parameter cases and considerable differences are observed between constant and variable nonlocal parameter cases. Mode shapes in various cases are depicted in order to explain the effects of axial grading.

Lumbo-sacro-pelvic Fixation Using Iliac Screws for the Complex Lumbo-sacral Fractures

  • Rhee, Woo-Tack;You, Seung-Hoon;Jang, Yeon-Gyu;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권6호
    • /
    • pp.495-498
    • /
    • 2007
  • Fractures of lumbo-sacral junction involving bilateral sacral wings are rare. Posterior lumbo-sacral fixation does not always provide with sufficient stability in such cases. Various augmentation techniques including divergent sacral ala screws, S2 pedicle screws and Galveston rods have been reported to improve lumbo-sacral stabilization. Galveston technique using iliac bones would be the best surgical approach especially in patients with bilateral comminuted sacral fractures. However, original Galveston surgery is technically demanding and bending rods into the appropriate alignment is time consuming. We present a patient with unstable lumbo-sacral junction fractures and comminuted U-shaped sacral fractures treated by lumbo-sacro-pelvic fixation using iliac screws and discuss about the advantages of the iliac screws over the rod system of Galveston technique.

Enterobacter Aerogenes에 의한 뇌실염에 대한 Pefloxacine의 뇌실내 주입 - 증 례 보 고 - (Intraventricular Pefloxacine Therapy for a Cerebral Ventriculitis by Enterobacter Aerogenes - Case Report -)

  • 이준행;이경회;홍승관
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권1호
    • /
    • pp.126-130
    • /
    • 2000
  • A 40-year-old female with hypertensive thalamic hemorrhage, secondary intraventricular hemorrhage, and hydrocephalus was treated with extraventricular drainage. She developed catheter-related ventriculitis caused by gram-negative rods, Enterobacter aerogenes. She was treated with systemic pefloxacine, ceftazidime, amikin and intraventricular vancomycin, gentamicin was unsuccessful. The ventriculitis was successfully controlled by intraventricular administration of the pefloxacine. Regarding their excellent activity against gram-negative rods, Enterobacter aerogenes, and probable safety when administered intraventricularly, administration of the pefloxacine, may be considered in the treatment of ventriculitis if the pathogen is resistant to other conventional antibiotics.

  • PDF

원자로 제어봉구동장치의 동작 검출을 통한 안전한 이중유지 방법 (The Method of safe double holding by detecting movements of Control Rod Drive Mechanism)

  • 천종민;김춘경;이종무;박민국;권순만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2655-2657
    • /
    • 2005
  • When a fault relating to the urgent alarm occurs, we must prevent control rods from dropping and make one of two grippers in Control Rod Drive Mechanism (CRDM) grip the drive rod taking a control rod assembly. To enhance the reliability of holding control rods, we order two grippers to hold the drive rod. This action is called the double holding. In the middle of the movement of the drive rod, the latching of the drive rod can cause friction between a gripper and the drive rod. This state may give damage to both the gripper and the drive rod. In this paper, we have devised the method which can have two grippers hold the drive rod more stably, without damaging the equipment.

  • PDF

선재 공정에서 C-Hook 트래킹을 위한 RFID 시스템 적용에 대한 연구 (A study on application of RFID systems for tracking of C-Hook in the wire rods process)

  • 권영신;이창우;반성준;조현우;김상우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.413-415
    • /
    • 2006
  • Wire rods are carried by C-Hooks and are tracked by bringing the inspection sensors into contact with steel bars on the C-Hooks. However, the conventional system using mechanical equipment is not reliable due to aging, wearing and bending of steel bars. To overcome these problems, a non-contact type identification system is required. This paper introduces the radio frequency identification(RFID) technology which is one of the most popular non-contact identification methods, and evaluates its performance in the real environment of POSCO. Specifically, we use tags which are designed for operating on high temperature and allowing easy attaching and detaching on the C-Hook. A new monitoring program is developed for reacting upon the conventional system and showing the results of reading of reading tags.

  • PDF

탄소주강품과 경강선재간의 미끄럼 마멸특성 (The Sliding Wear Characteristics of the Carbon Steel Castings against High Carbon Steel Wire Rods)

  • 류중북;채영훈;김석삼
    • Tribology and Lubricants
    • /
    • 제19권4호
    • /
    • pp.223-229
    • /
    • 2003
  • The sliding wear characteristics of the crane sheave were investigated using a pin-on-disk rig tester. The experiment was conducted using a high carbon steel wire that was upper material, also carbon steel castings that was disk material. There are various operating conditions in this work. At the room temperature, we carried out the wear test under a grease lubrication and dry condition. The results of wear test showed that an annealed-casted have lower, also the wear curves are linearly increased with increasing of sliding distance. For the specific wear rate of annealed-casted, the wear resistance was increased with decreasing diameter of wire. The wear of a wire and a disk have a different mechanism, the one is the abrasive wear due to fatigue wear under lubrication, another is the adhesion wear under dry condition.

Crystal Growth of Nd:YAG for 1.06$\mu m$ Lasers

  • Yu, Y.M.;Jeoung, S.J.;Koh, J.C.;Ryu, B.H.
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1998년도 PROCEEDINGS OF THE 14TH KACG TECHNICAL MEETING AND THE 5TH KOREA-JAPAN EMGS (ELECTRONIC MATERIALS GROWTH SYMPOSIUM)
    • /
    • pp.165-167
    • /
    • 1998
  • Nd:YAG crystals were grown by Horizontal Bridgman method. The effects of sliding rate (growth rate) of Molydbenum container, growth atmosphere and concentration of Neodymium ions on crystal qualities were investigated. The size of the crystals grown was up to 150-200 mm in length, 70 mm in width and 25-35 mm in thickness. Crystals grown under the optimum conditions were violet, transparent and could not be observed any macroscopic defects. Under the polarizing microscopoc observations with crossed polar, striations, {211} facets and inclusions were detected. With the grown crystals, prototypes of laser rods for 1.06$\mu$m laser application were manufactured and then characterized. As a result, we can get high quality of Nd:YAG laser rods with <111> and <110> axis, 63 mm in length and6.3 mm in diameter.

  • PDF

연약지반의 강성 측정을 위한 벤더 엘리멘트의 현장 적용성 연구 (Implementation of Bender Elements to In-situ Measurements of Stiffness of Soft Clays)

  • 정재우;한만진;김봉찬;목영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.161-170
    • /
    • 2006
  • Bender elements, composed of thin piezo-ceramics and elastic shims, have been used to measure shear wave velocities of specimens in laboratories. In a preliminary stage of their field applications, an in-house research of optimizing suitable bender elements and geometrical arrangement has been carried out in a barrel of kaolinite-water mixture. Two types of measurement configuration, similar to cross-hole and in-hole seismic testing, has been implemented. A pair of prototype instrumented rods was penetrated into a soft clay layer in the west coast and excellent shear waves were recorded. Development of penetration device(mandrel) and associated instrumented rods are in progress for deeper investigation.

  • PDF