• Title/Summary/Keyword: RN

Search Result 518, Processing Time 0.027 seconds

Growth Root Tuber and Economic Yields of Chinese Yam and Their Relationship as Affected by Tuber Head Origin and Fertilizer Application Method (두부종류와 여비방법에 따른 장마의 생육, 괴근수량 및 상품성과 이들간의 관계)

  • 김영광
    • Korean Journal of Plant Resources
    • /
    • v.8 no.2
    • /
    • pp.201-207
    • /
    • 1995
  • Chinese yam (Dioscorea Opposita Thanb) has been cultivated as medicinal crop and food. The experiment was carried out to determine the effect of tuber head origin and fertilizer application method on its agronomic characters of shoot and root tuber to get some imformation on its cultivation. The tuber head cultivated were cut from normal or branched root tuber. 37-28-32-2000 : N-P-K-Humus(Kg/10a) by dispersal but 30% N reduction of Con(RN) or strip application on the two-side of hill(SRN), were applied but N and K were given by the above method with the rate of 40% in March, 30% in June and 30% in July. Agronomic characteristics related to shoot and root tuber were measured and their relationship was analyzed. Tuber head origin had no effect on emergence rate, vine length, branch and node of vine, while emergence date of the tuber head from the normal root which showed the greatest emergence rate, vine length and node in Con treatment was earlier than the others. The tuber head from the normal root, furthermore, had greater length and diameter of root tuber harvested from the field and fresh weight per plant of per 10a compared to the tuber head from the branched root, whereas in both the normal and the branched tuber head RN had the worst result in the characters related to tuber yield except tuber diameter. The tuber head from the normal root produced heavier root tuber than that from the branched tuber and SRN had the best economic yield among the application methods, which resulted from production of less branched root tubers and their rate. In both the normal and the branched tuber head, moreover, yield per plant and economic yield were positively correlated to tuber length but negatively done to number. of branch of vine.

  • PDF

Properties in Strength of Raschel Netting (랏쉘그물감의 강도)

  • KIM Dai An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 1978
  • 1) The decrease in strength of Raschel twines at Raschel joints is regarded to be due mainly to the frictional force between yarns and the unbalanced tensile distribution by the deformation of the joints. The rate of the decrease is about $13\%$ in lengthwise pull and 22 to $26\%$ in breadthwise pull. 2) The 3-course joint is less in deformation and stronger than the 2-course joint in all cases of pulls. 3) The variation of Raschel joint strength $T_R$ with the angle $\varphi$ between the adjacent bars is expressed as $T_R=T_{R0}-k\varphi$ where $T_{R0}$ is the strength at $\varphi=0^{\circ}$ and K is a constant. 4) The tensile strength ${\sigma}R$ and tile breaking energy $E_R$ of Raschel netting are given by $${\sigma}R=KN\;or\;${\sigma}R=T_RN$$ and $$E_R=AN$$ respectively, where N is the number of meshes at the pulling side, and K and A are constants. But the breaking energy of the netting is almost constant independent of tile variation of N. 5) The Raschel netting with some bars cut already breaks from tile joints of the bars next to the cut bars and its tensile strength, breaking energy, and breaking elongation decrease largily even if only one bar is in already cut state. 6) The tearing strength of Raschel netting is almost equal to the tensile strength of its single joint pulled by two bars. 7) The twisted joint is much more excellent in strength than the knot or the Raschel joint. The knot strength is 69 to $76\%$, and the Raschel joint strength is 71 to $74\%$ in lengthwise pull and 62 to $67\%$ in breadthwise pull, respectively, of the twisted joint strength.

  • PDF

A Rapid Analysis of 226Ra in Raw Materials and By-Products Using Gamma-ray Spectrometry (감마분광분석을 이용한 원료물질 및 공정부산물 중 226Ra 신속분석방법)

  • Lim, Chung-Sup;Chung, Kun-Ho;Kim, Chang-Jong;Ji, Young-Yong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.1
    • /
    • pp.35-44
    • /
    • 2017
  • A gamma-ray peak of $^{226}Ra$ (186.2 keV) overlaps with one of $^{235}U$ (185.7 keV) in a gamma-ray spectrometry system. Though reference peaks of $^{235}U$ can be used to correct the peak interference of $^{235}U$ in the analysis of $^{226}Ra$, this requires a complicated calculation process and a high limit of quantitation. On the other hand, evaluating $^{226}Ra$ using the correction constant in the overlapped peak can make a rapid measurement of $^{226}Ra$ without the complicated calculation process as well as overcome the disadvantage in the indirect measurement of $^{214}Bi$, which means the confinement of $^{222}Rn$ gas in a sample container and a time period to recover the secular equilibrium. About 93 samples with 6 species for raw-materials and by-products were prepared to evaluate the activity of $^{226}Ra$ using the correction constant. The results were compared with the activity of $^{214}Bi$, which means the indirect measurement of $^{226}Ra$, to validate the method of the direct measurement of $^{226}Ra$ using the correction constant. The difference between the direct and indirect measurement of $^{226}Ra$ was generally below about ${\pm}20%$. However, in the case of the phospho gypsum, a large error of about 50% was found in the comparison results, which indicates the disequilibrium between $^{238}U$ and $^{226}Ra$ in the materials. Application results of the contribution ratio of $^{226}Ra$ were below about ${\pm}10%$. The direct measurement of $^{226}Ra$ using the correction constant can be an effective method for its rapid measurement of raw materials and by-products because the activity of $^{226}Ra$ can be produced with a simple calculation without the consideration of the integrity of a sample container and the time period to recover the secular equilibrium.

A Study on the Nurse's Due Care in Medical Malpractice (의료과오시(醫療過誤時) 간호사의(看護師)의 주의의무(注意義務)에 관한 연구(硏究))

  • Kang, Sun-Joo
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.1
    • /
    • pp.113-136
    • /
    • 1999
  • There are some new trends in judgments concerning medical malpractice. which include emphasis on medical professionals' explanation duty in order to materialize patient's rights of self-determination. Now, patient is not a mere subject of medical and nursing care any more, but a subject, participating in medical practice on equal terms with medical professionals. Legal accountability is no limited to nurses in advanced practice: it is a recognized fact of life for every practicing nurse. whether she is an RN employed as a staff nurse in a hospital, a Certified Nurse-Midwife in independent practice or a patient's home. Therefore, it is essential for nurses to be as familiar as possible with the legal guidelines that govern their patient care responsibilities. However there are only a few studies focused on nursing negligence. To define nurse's civil liability in medical malpractice, it is necessary to indentify both legal nursing behaviors and nurse's due care in those nursing behaviors. So this paper focused on nurse's due care, especially in nursing malpractice. To clarify nurses' due care. chapter II has focused on nursing behavior and the scope of nursing practice based on the medical law and health care related study results. Chapter III deals with the content and scope of nurse's due care. Generally. negligence is defined as not doing something which a resonable person. guided by those ordinary considerations which or dinarily regulate human affairs. would do. or doing something which a resonable and prudent man would not do. Next. it describes how we can set the standard of due care in nursing practice. There is objective factors and subjective factors. And we also discuss about the limitation of due care in nursing practice. Finally. chapter IV deals with the case studies related to nursing negligence in the situation of determination. Now', patient is not a mere subject of medical and nursing care any more, but a subject participating in medical practice on equal terms with medical professionals. Legal accountability is not limited to nurses in advanced practice; it is a recognized fact of life for every practicing nurse. whether she is an RN employed as a staff nurse in a hospital. a Certified Nurse-Midwife in independent practice or a patient's home. Therefore, it is essential for nurses to be as familiar as possible with the legal guidelines that govern their patient care responsibilities. However. there are only a few studies focused on nursing negligence. To define nurse's civil liability in medical malpractice, it is necessary to identify both legal nursing behaviors and nurse's due care in those nursing behaviors. So this paper focused on nurse's intravenous injection. post operation nursing care. blood transfusion. and patient nursing care. The result of this paper is as follows. First. there are several cases dealing with nurse's negligence in nursing practice. however, those cases didn't judge nurse's due care based on individual -specific standard but general-objective standard. Second, there is a tendency to put an emphasis on the principal of belief to distinguish who has the liability in the case of medical malpractice among medical care team. So nurses shoud practice nursing care more actively to protect themselves and patients because there is an effort to form professional nurse system and the scope of nursing practice will be deeper and broader. Third, standard of care is a necessary element in establishing negligence. If a nurse is able to meet the standard of care, no breach will be found.

  • PDF

Role of NO in Activation of $NF{\kappa}B$ by PM2.5 in Lung Epithelial Cells (PM2.5로 자극한 폐상피세포의 $NF{\kappa}B$ 활성화에 NO의 역할)

  • Kim, Kyoung-Ah;Nam, Hae-Yun;Mun, Je-Hyeok;Jeong, Jin-Sook;Lim, Young;Kai, Hirofumi
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.6
    • /
    • pp.616-626
    • /
    • 2002
  • Background : The present study was performed to further improve our understanding of molecular mechanisms involved in the activation of NFkB, a major transcriptional factor involved in the inflammatory response in the lung, by particulate matter in lung epithelial cells with an aerodynamic diameter of less than $2.5{\mu}m$(PM2.5). Materials and Methods : Immediate production of reactive oxygen species (ROS) and nitrogen species (RNS), with the PM2.5 induced expression of inducible nitric oxide synthase (iNOS), $I{\kappa}B$ degradation and $NF{\kappa}B$-dependent transcriptional activity, in 549 cells, were monitored. Addition, we also examined the effect of the iNOS inhibitor, L-N6-(1-iminoethyl) lysine hydrochloride (L-NIL), on the PM2.5-induced $NF{\kappa}B$ activation in A549 cells. Results : The rapid degradation of $I{\kappa}B$ and the increase of transcriptional activity of the $NF{\kappa}B$-dependent promotor were observed in A549 cells exposed to PM2.5. The immediate production of ROS in response to PM2.5 in A549 cells was not clearly detected, although immediate responses were observed in RAW264.7 cells. A 549 cells, cultured in the presence of PM2.5, produced an increase in NO, which was noticeably significant after 15 min of exposure with the expression of iNOS mRNA. The addition of L-NIL, an iNOS inhibitor, significantly inhibited the PM2.5-induced $I{\kappa}B$ degradation and the increase of the $NF{\kappa}B$-dependent transcriptional activity. Conclusion : These results suggest that PM2.5 stimulates the immediate production of RNS, leading to the activation of $NF{\kappa}B$ in the pulmonary epithelium.

The Concentration of Indoor Air Quality and Correlations of Materials at Multiple-use Facilities in Gwangju (광주지역 다중이용시설에서 실내공기질 농도와 상관성 분석)

  • Lee, Dae-Haeng;Lee, Se-Haeng;Bae, Seok-Jin;Kim, Nan-Hee;Park, Kang-Soo;Kim, Do-Sool;Paik, Ke-Jin;Moon, Yong-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.11
    • /
    • pp.1001-1010
    • /
    • 2010
  • The purpose of this study is to investigate the concentration levels of particle materials ($PM_{10}$, asbestos), gas materials ($CO_2$, CO, $NO_2$, HCHO, Rn, VOCs) and total suspended colony (TSC), and the correlations among these materials in indoor air quality of 54 multiple-use facilities and 15 public-use facilities of Gwangju. The highest mean concentration of $PM_{10}$ was $69.2\;{\mu}g/m^3$ at indoor parking place, followed by childcare facilities, large commercial building and subway station building. The highest mean concentration of CO was 2.7 ppm at indoor parking place and that of $CO_2$ was 604.1 ppm at medical service facilities. The highest mean concentration of $NO_2$ was 0.036 ppm at indoor parking place. The geomean concentration of HCHO was $3.6\;{\mu}g/m^3$ in all facilities and the highest was $631.8\;{\mu}g/m^3$ at art gallery. The geomean concentration of VOCs (5 species) was $24.14\;{\mu}g/m^3$ in all facilities and toluene was the highest material of $15.30\;{\mu}g/m^3$, followed by xylene, ethylbenzene, benzene and styrene. The highest mean concentration of TSC was $625.3\;CFU/m^3$ at jjimjilbang, followed by childcare facilities, medical service facilities and large commercial building. The highest of asbestos was 0.0072 each/cc at childcare facilities and that of radon was 1.41 pCi/L at art gallery. PM10 showed positive correlations to TSC with $R^2\0.5332$ by lognormal equation at childcare facilities. CO2 showed positive correlations to CO at childcare facilities and indoor parking place. Lognormal equation fitted to the VOCs data more than normal equation in all facilities.

Performance Evaluation of Several Radon Detectors in the Standard Chamber and Dwellings (라돈 표준실과 가옥 내에서 일부 라돈검출기에 대한 성능 평가)

  • Yoon, Seok-Won;Kim, Yong-Jae;Chang, Byung-Uck;Byun, Jong-In;Yun, Ju-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.173-181
    • /
    • 2008
  • To ensure the performance of radon detectors, three passive radon detectors ($RadTrak^{(R)}$, $Radopot^{(R)}$, and $E-PERM^{(R)}$)have been reviewed. The difference ratios of RadTrak and Radopot tested in the radon standard chamber were -13.2% and -6.0%, respectively, which were in good accordance within 20% of the value measured by $AlphaGUARD^{(R)}$. To ensure the performance of the long term measurement, the 3 detectors were installed at the same position of approximately one hundred of dwellings for one year. The correlation curve between RadTrak and Radopot shows good agreement with a correlation coefficient ($R^2$) of 0.91. However, The correlation curve between E-PERM and Radopot shows bad agreement ($R^2$ = 0.021). In addition, the distribution map of annual mean indoor gamma dose rate measured with E-PERM was not in accordance with the distribution map of outdoor gamma dose rate measured by Portable Ion Chamber. According to the results, some requisites for the selection of the radon passive detectors in the large-scale indoor radon survey were discussed.

Neuroprotective Effects of Pinelliae Rhizoma Water-Extract by Suppression of Reactive Oxygen Species and Mitochondrial Membrane Potential Loss in a Hypoxic Model of Cultured Rat Cortical Cells. (배양대뇌신경세포 저산소증모델에서 유해산소생성억제 및 사립체막전위 소실방지에 의한 반하(半夏)의 신경세포사 억제 효능)

  • Kwon, Gun-Rok;Moon, Il-Soo;Lee, Won-Chul
    • Journal of Life Science
    • /
    • v.19 no.5
    • /
    • pp.598-606
    • /
    • 2009
  • Oxidative stress by free radicals is a major cause of neuronal cell death. Excitotoxicity in hypoxia/ischemia causes an increase in reactive oxygen species (ROS) and a loss of mitochondrial membrane potential (MMP), resulting in dysfunction of the mitochondria and cell death. Pinelliae Rhizoma (PR) is a traditional medicine for incipient stroke. We investigated the effects of PR Water-Extract on the modulation of ROS and MMP in a hypoxic model using cultured rat cortical cells. PR Water-Extract was added to the culture medium at various concentrations (0.25${\sim}$5, 5.0 ${\mu}g/ml$) on day in vitro 12(DIV12), given a hypoxic shock (2% $O_2$/5% $CO_2$, $37^{\circ}C$, 3 hr), and cell viability was assessed on DIV15 by Lactate Dehydrogenase Assay (LDH assays). PR Water-Extract showed a statistically significant effect on neuroprotection (10${\sim}$15% increase in viability; p<0.01) at 1.0 and 2.5 ${\mu}g/ml$ in normoxia and hypoxia. Measurement of ROS production by $H_2DCF-DA$ stainings showed that PR Water-Extract efficiently reduced the number and intensity of ROS-producing neurons, especially at 1 hr post shock and DIV15. When MMP was measured by JC-1 stainings, PR Water-Extract efficiently maintained high-energy charged mitochondria. These results indicate that PR Water-Extract protects neurons in hypoxia by preventing ROS production and preserving the cellular energy level.

Evaluation of Indoor Radon Levels in a Hospital Underground Space and Internal Exposure (의료기관 지하시설의 라돈가스 측정과 내부피폭 조사)

  • Song, Jea-Ho;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.231-235
    • /
    • 2011
  • Radium is rock or soil of crust or uranium of building materials and thorium after radioactivity collapse process are created colorless and odorless inert gas that accrue well in sealed space like mine or basement. It inflow to lung circulate respiratory organ and caused lung cancer because of deposition of lung or bronchial tubes. Radium sheath of medical institution treat person's life is possible big danger to professional regarding radioactivity who has much amount exposed radioactivity and weaker immune patient. so we do this test. Using measuring instrument at test is real time radium measuring instrument, Professional Continuous Radon monitor, and measuring places are basement first floor and second floor of two hospitals and measure from 10 a.m to 3 p.m. Measurement result of Professional Continuous Radon monitor is minimum 14.8 Bq/$m^3$ to maximum 70.3 Bq/$m^3$ and show domestic baseline below 148 Bq/$m^3$, effective dose-rate is minimum 0.296 mSv to maximum 1.406 mSv that show 2.4 mSv, 10~58.3% level, exposed radiation amount from nature radiation one year.

Evaluation for Effectiveness of Radon Mitigation on Dwellings and Public Buildings in Korea (건축물 유형에 따른 라돈 저감 효과 평가)

  • Lee, DongHyun;Ryu, Seung-Hun;Jo, JungHeum;Seo, SungChul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.518-527
    • /
    • 2014
  • Objectives: The adverse health effects attributed to exposure to radon have been well known over the world. However, the efforts for prevention and mitigation of radon have not been taken in Korea so far. The purpose of this study was to evaluate the effectiveness of mitigation methods applied for various types of houses and public buildings with high level of radon. Methods: Based on the results of "National Radon Survey" performed by the National Institute of Environmental Research(NIER) in 2010-2012, we selected 30 candidate buildings consisting of 20 houses and 10 public buildings with greater than $148Bq/m^3$ of radon level. We measured the concentration of radon in 30 buildings, using E-PERMs and RAD-7 during January to March of 2013. More than five E-PERMs and one RAD-7 per house were installed for seven days. Ten houses and five public buildings were finally chosen to be mitigated after mainly considering the level of radon and the location of buildings nationwide. Three mitigation methods such as Sealing, two types of Active Ventilation(window-shaped and wall-typed ventilations), and Active Soil Depressurization(ASD) were applied, and the concentrations of radon were measured before and after mitigation, respectively. To evaluate the effectiveness of mitigation methods, reduction rates of radon were calculated and Wilcoxon's signed-rank test was performed. Results: The mean concentration of 15 buildings just before radon mitigation was $297.8Bq/m^3$, and most of the buildings were located in Gangwon, Chungbuk, Chungnam, and Daegu areas(73.3%), and built in 1959-1998. The level of radon decreased from 48% to 90% and kept the below recommendation limit of $148Bq/m^3$ after installation of radon mitigation. Among mitigation methods applied, the reduction rate(58.7-90.4%) of radon attributed to ASD was the greatest than that of other methods, followed by Active Ventilation(48.4-78.4%) and Sealing(<22%). The effectiveness of radon reduction by window-shaped Active Ventilation(63.2-75.2%) was relatively better than that of wall-typed Active Ventilation(48.4-54.3%). Conclusions: The results of this study indicate that ASD could be more effective for radon mitigation. Moreover, our findings would be background information in future for making the strategy for radon mitigation nationwide, as well as for developing Korean-version of mitigation techniques according to types of dwellings in Korea.