• Title/Summary/Keyword: RMS signal

Search Result 304, Processing Time 0.028 seconds

Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves (발전용 밸브누설 음향 진단 및 감시시스템)

  • Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

Automatic Phonetic Segmentation of Korean Speech Signal Using Phonetic-acoustic Transition Information (음소 음향학적 변화 정보를 이용한 한국어 음성신호의 자동 음소 분할)

  • 박창목;왕지남
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.8
    • /
    • pp.24-30
    • /
    • 2001
  • This article is concerned with automatic segmentation for Korean speech signals. All kinds of transition cases of phonetic units are classified into 3 types and different strategies for each type are applied. The type 1 is the discrimination of silence, voiced-speech and unvoiced-speech. The histogram analysis of each indicators which consists of wavelet coefficients and SVF (Spectral Variation Function) in wavelet coefficients are used for type 1 segmentation. The type 2 is the discrimination of adjacent vowels. The vowel transition cases can be characterized by spectrogram. Given phonetic transcription and transition pattern spectrogram, the speech signal, having consecutive vowels, are automatically segmented by the template matching. The type 3 is the discrimination of vowel and voiced-consonants. The smoothed short-time RMS energy of Wavelet low pass component and SVF in cepstral coefficients are adopted for type 3 segmentation. The experiment is performed for 342 words utterance set. The speech data are gathered from 6 speakers. The result shows the validity of the method.

  • PDF

Analysis of Sound Signal by Conducting Particle in Coaxial Cylindrical Electrodes (동축원통 전극내의 파티클에 의한 음향신호 분석)

  • 조국희;권동진;곽희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.104-110
    • /
    • 1997
  • In thes paper, the soung signals due to the collisions against the inside wall by conductint particles with in coaxial cylindrical electrodes, and the corresponding frequency spectrum are analyzed and discribed.Thesesound signals were detected and measured using ultrasonic and vibration sensors attached to the exterior of the GIS enclosure. In the case where a particls is bouncing about between these coaxoal electrodes, the sound signal was found to be more than 10[dB] greater than the background noise due to no particlel. Also, in the case where a particle collides and insulation breakdown caesed by the particle made it possible to determine the condition of the insulation inside the sealed GIS. Lastly, the relationship between the peak amplitude and RMS voltage of the measured signal, the diameter and length of the particle was analyzed. Using thes analysis, it is possible to confirm the size of particle.

  • PDF

Positioning using ZigBee and Ultrasound

  • Park, Chan-Sik;Kim, Seung-Beom;Kang, Dong-Youn;Yun, Hee-Hak;Cha, En-Jong;Lee, Sang-Jeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.217-222
    • /
    • 2006
  • To find a location, GPS has been wildly used. But, it is hard to use in indoor because of very weak signal level. To meet indoor requirements, there have been many studies applying wireless communication networks such as WLAN, UWB and ZigBee. Among these, ZigBee is widely adopted in many WSN applications because it has an advantage of low-power and low-cost. In ZigBee, the RSSI is used as range measurement for ad-hoc network. The RSSI are converted to ranges using the signal attenuation model and these ranges become inputs of positioning methods. The obtained position with RSSI has large error because of its poor accuracy. To overcome this problem, ultrasonic sensors are added in many researches. By measuring the arrival time difference of ZigBee and ultrasound as a range measurement, the precise position can be found. However, there are still many problems: scheduling of beacons to transmit signals in a correct order, addition and synchronization of beacons and low-rate positioning rate. At this paper, an efficient method to solve these problems is proposed. In the proposed method, a node transmits ZigBee and ultrasound signal simultaneously. And beacons find the range with the received signals and send it back to a node with ZigBee. The position is computed in a node with the received ranges. In addition, a new positioning algorithm to solve the risk of the divergence in the linearization method and the singularity problem in the Savarese method is presented. Both static and dynamic experimental results show 0.02m RMS errors with high output rate.

  • PDF

Phase Error Decrease Method for Target Direction Detection Improvement (표적 방향 탐지 향상을 위한 위상 오차 감소 방법)

  • Lee, Min-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.1
    • /
    • pp.7-13
    • /
    • 2021
  • This paper proposes a method to minimize the target's direction detection error using RADAR. The radar system cannot accurately detect the target direction due to the phase error of he received signal. The proposed method of this study obtains a phase by applying an root mean square to each antenna incident signal, and reduces the phase error by using an optimal signal to noise ratio. In the simulation result, the probability of detecting the target direction is the best when the antenna spacing is half wavelength. The conventional method of direction detection probability 10-1.7 and the proposed method is 10-3.3. The target detection direction of the existing method represents [-8°,8°] with an error of 2 degrees. The target detection direction of the proposed method is shown in [-10°,10°], and all target directions are accurately detected. In the future, There is need for a method to reduce the phase error even though the resolution decrease.

Efficient FPGA Logic Design for Rotatory Vibration Data Acquisition (회전체 진동 데이터 획득을 위한 효율적인 FPGA 로직 설계)

  • Lee, Jung-Sik;Ryu, Deung-Ryeol
    • 전자공학회논문지 IE
    • /
    • v.47 no.4
    • /
    • pp.18-27
    • /
    • 2010
  • This paper is designed the efficient Data Acquisition System for an vibration of rotatory machines. The Data Acquisition System is consist of the analog logic having signal filer and amplifier, and digital logic with ADC, DSP, FPGA and FIFO memory. The vibration signal of rotatory machines acquired from sensors is controlled by the FPGA device through the analog logic and is saved to FIFO memory being converted analog to digital signal. The digital signal process is performed by the DSP using the vibration data in FIFO memory. The vibration factor of the rotatory machinery analysis and diagnosis is defined the RMS, Peak to Peak, average, GAP, FFT of vibration data and digital filtering by DSP, and is need to follow as being happened the event of vibration and make an application to an warning system. It takes time to process the several analysis step of all vibration data and the event follow, also special event. It should be continuously performed the data acquisition and the process, however during processing the input signal the DSP can not be performed to the acquisited data after then, also it will be lose the data at several channel. Therefore it is that the system uses efficiently the DSP and FPGA devices for reducing the data lose, it design to process a part of the signal data to FPGA from DSP in order to minimize the process time, and a process to parallel process system, as a result of design system it propose to method of faster process and more efficient data acquisition system by using DSP and FPGA than signal DSP system.

Optimized DSP Implementation of Audio Decoders for Digital Multimedia Broadcasting (디지털 방송용 오디오 디코더의 DSP 최적화 구현)

  • Park, Nam-In;Cho, Choong-Sang;Kim, Hong-Kook
    • Journal of Broadcast Engineering
    • /
    • v.13 no.4
    • /
    • pp.452-462
    • /
    • 2008
  • In this paper, we address issues associated with the real-time implementation of the MPEG-1/2 Layer-II (or MUSICAM) and MPEG-4 ER-BSAC decoders for Digital Multimedia Broadcasting (DMB) on TMS320C64x+ that is a fixed-point DSP processor with a clock speed of 330 MHz. To achieve the real-time requirement, they should be optimized in different steps as follows. First of all, a C-code level optimization is performed by sharing the memory, adjusting data types, and unrolling loops. Next, an algorithm level optimization is carried out such as the reconfiguration of bitstream reading, the modification of synthesis filtering, and the rearrangement of the window coefficients for synthesis filtering. In addition, the C-code of a synthesis filtering module of the MPEG-1/2 Layer-II decoder is rewritten by using the linear assembly programming technique. This is because the synthesis filtering module requires the most processing time among all processing modules of the decoder. In order to show how the real-time implementation works, we obtain the percentage of the processing time for decoding and calculate a RMS value between the decoded audio signals by the reference MPEG decoder and its DSP version implemented in this paper. As a result, it is shown that the percentages of the processing time for the MPEG-1/2 Layer-II and MPEG-4 ER-BSAC decoders occupy less than 3% and 11% of the DSP clock cycles, respectively, and the RMS values of the MPEG-1/2 Layer-II and MPEG-4 ER-BSAC decoders implemented in this paper all satisfy the criterion of -77.01 dB which is defined by the MPEG standards.

A GaAs MMIC Multi-Function Chip with a Digital Serial-to-Parallel Converter for an X-band Active Phased Array Radar System (X-대역 능동 위상 배열 레이더 시스템용 디지털 직병렬 변환기를 포함한 GaAs MMIC 다기능 칩)

  • Jeong, Jin-Cheol;Shin, Dong-Hwan;Ju, In-Kwon;Yom, In-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.6
    • /
    • pp.613-624
    • /
    • 2011
  • An MMIC multi-function chip for an X-band active phased array radar system has been designed and fabricated using a 0.5 ${\mu}m$ GaAs p-HEMT commercial process. A digital serial-to-parallel converter is included in this chip in order to reduce the number of the control interface. The multi-function chip provides several functions: 6-bit phase shifting, 6-bit attenuation, transmit/receive switching, and signal amplification. The fabricated multi-function chip with a relative compact size of 24 $mm^2$(6 mm${\times}$4 mm) exhibits a transmit/receive gain of 24/15 dB and a P1dB of 21 dBm from 8.5 GHz to 10.5 GHz. The RMS errors for the 64 states of the 6-bit phase shift and attenuation were measured to $7^{\circ}$ and 0.3 dB, respectively over the frequency.

Comparision of Signal-Averaged Electrocardiography (SAECG) Determined by Flank Lead System (FLS) and Pyramidal Lead System (PLS) in Healthy Young Adults (정상 성인의 직교유도체제와 피라미드유도체제에 의한 신호 가산 평균심전도의 비교)

  • Jang, Byeong-Ik;Kang, Seung-Ho;Kim, Hyeung-Il;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.179-189
    • /
    • 1993
  • It has recently become possible to record electrical activity originating from abnormally conducting myocardium from the body surface with high - gain amplification and averaging technique. These signals, which result from delayed ventricular activation(late potentials), have been recorded in patients with documented ventricular tachyarrythmia. Several electrode lead system for detecting ventricular late potential were introduced. Pyramidal electrode lead system(PLS) is useful. Also interpretation of SAECG in the young could be of value in detecting those at risk for episodic ventricular tachycardia, but suffer from a lack of data in normal young people. Selection of subjects : For this study, normal healthy young adult volunteers (age: mean 24 years) were recruited from the medical students at Yeungnam University Hospital, Internal Medicine. Twenty fourths male and seventeenths female subjects were selected. All subjects had normal resting ECGs as judged from both the standard 12 channel lead and echocardiography, and none had a history of cardiovascular disease. All subjects were considered to be in good general physical condition. Signal-averaged electrocardiography : In order to obtain low noise recordings with a small number of averaging cycles, all subject ware asked to relax completely in the supine position. Silver/silver chloride electrodes were attached after the skin was cleaned with alcohol, to constitute classic flank lead system(FLS) and pyramidal lead system(PLS). Signals were recorded and processed using a commercially available microprocessor-augmented ECG cart(Marquette Electronics, USA) suitable for portable bedside recording. There was no difference between normal values, determined by FLS and PLS at high pass filtering of 25 Hz and 80 Hz, but significant, difference was found in HFLAD and RMS-40 of 40 Hz(p<0.05). These results will provide a basis for interpretations of SAECG, determined by FLS and PLS in healthy young adults with normal QRS duration.

  • PDF

On the Performance Analysis of Coherent Bandwidth in Underwater Channel Environments Using Beamforming Technologies Based on the Use of Measurement Data (측정 데이터를 이용한 빔형성기의 적용에 의한 수중 채널 환경에서의 상관 대역폭 분석)

  • Kim, Min-Sang;Cho, Dae-Young;Kim, Kye-Won;Lee, Tae-Seok;Park, Jong-Won;Lim, Yong-Gon;Ko, Hak-Lim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.4
    • /
    • pp.162-168
    • /
    • 2014
  • The OFDM system have been widely studied for the purpose of increasing data rate with more reliable communications in underwater channel environments. And it is possible only when the sub-carrier's bandwidth is smaller than the coherence bandwidth of channel in the underwater OFDM communication system. However, the size of the FFT for the OFDM system will be increased because the coherence bandwidth is as small as several tens of Hz in real underwater channel environments. Also, It is necessary to add a CP having a length longer than the rms delay spread of a channel. So the complexity of the system is increased and the data efficiency is reduced. Therefore, in this paper, we have studied the increase of the coherence bandwidth by adapting the beamforming technologies. To do this, we have collected data from real underwater channel environments and analyzed the coherence bandwidth when adapting the beamforming technologies. Analyzing the experimental data show that the coherence bandwidth by the beamforming technologies in underwater channel environments was greatly increased compared to that of a single sensor.