• Title/Summary/Keyword: RHI

Search Result 71, Processing Time 0.02 seconds

A Study of User's Characteristics of Searching Behavior on the World-Wide Web (인터넷 이용자의 검색 행동 성향에 관한 연구)

  • Oh Kyung-Mook;Hwang Sang-Kyu;Rhi Yong-Hyun
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.33 no.3
    • /
    • pp.87-108
    • /
    • 1999
  • Information retrieval on World Wide Web is very different from the one in traditional environment. Since Internet user's searching behavior shows it's own special search characteristics, a study of user's specific characteristics is necessary to offer better services. Through analysis and examination of Internet user behaviors, we suggest guidelines of design for developing Internet -based information retrieval systems.

  • PDF

3D Coordinates Acquisition by using Multi-view X-ray Images (다시점 X선 영상을 이용한 3차원 좌표 획득)

  • Yi, Sooyeong;Rhi, Jaeyoung;Kim, Soonchul;Lee, Jeonggyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.10
    • /
    • pp.886-890
    • /
    • 2013
  • In this paper, a 3D coordinates acquisition method for a mechanical assembly is developed by using multiview X-ray images. The multi-view X-ray images of an object are obtained by a rotary table. From the rotation transformation, it is possible to obtain the 3D coordinates of corresponding edge points on multi-view X-ray images by triangulation. The edge detection algorithm in this paper is based on the attenuation characteristic of the X-ray. The 3D coordinates of the object points are represented on a graphic display, which is used for the inspection of a mechanical assembly.

Thermal characteristics of Nanofluidic Heatpipe Hot Chuck (나노유체를 이용한 히트파이프 핫척의 열적 특성)

  • Lim, Taek-Kyu;Rhi, Seok-Ho;Kim, Dae-Hyun;Lee, Chung-Gu
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2110-2115
    • /
    • 2008
  • In this study, We disigned and manufactured the Hot Chuck which can be operated until $120^{\circ}C$. Its shape is circular, wide is 300mm and depth is 15mm. Two types working fluid was used as working fluid(distilled water, 0.1%-$TiO_2$ nanofluid). The experimental results were compared to each working fluid. The effect of various working fluid, charging volume ratio was investigated. Also we investigated heat transfer rate against each working fluid. By using nanofluid, heat transfer rate can be enhanced and the wick structure can be constructed automatically on smooth surface. The experiment of 40% charged 0.1%-$TiO_2$ nanofluid showed the best performance of thermal accuracy and uniformity. To improve performance of Hot Chuck, more study is needed.

  • PDF

Study on Improvement of Surface Temperature Uniformily in Flate-Plate Heat Pipe Hot Chuck (평판형 히트파이프식 핫척의 표면온도 균일화 향상을 위한 연구)

  • Kim, D.H.;Rhi, S.H.;Lim, T.K.;Lee, C.G.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2369-2374
    • /
    • 2008
  • In the precision hot plate for wafer processing, the temperature uniformity of upper plate surface is one of the key factors affecting the quality of wafers. Precision hot plates require temperature variations less than ${\pm}1.5%$ during heating to $120^{\circ}C$. In this study, we have manufactured the flat plate heat pipe hot chuck of circle type(300mm) and investigated the operating characteristics of flat plate heat pipe hot chuck experimentally. Various liquids(aceton, FC-40, water) were used as the working fluid and charging ratio was changed($14{\sim}36\;vol.%$). Several cases were tested to improve temperature uniformity. Major working fluid to be investigated was water. Using water, various parameters such as charging ratio, wafer operation on-off time, different working fluids. In case of water, the temperature uniformity was ${\pm}1.5%$, response time of wafer were investigated.

  • PDF

Experimental Validation of Two Simulation Models for Two-Phase Loop Thermosyphons

  • Rhi, Seok-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.4
    • /
    • pp.159-169
    • /
    • 2003
  • Five two-phase closed loop thermosyphons (TLTs) specially designed and constructed for the present study are one small scale loop, two medium scale loops (MSLI and MSLII) and two large scale loops (LSLI and LSLII). Two simulation models based on thermal resistance network, lumped and sectorial, are presented. In the Lumped model, the evaporator section is dealt as one lumped boiling section. Whereas, in the Sectorial model, all possible phenomena which would occur in the evaporator section due to the two-phase boiling process are considered in detail. Flow regimes, the flow transitions between flow regimes and other two-phase parameters involved in two-phase flows are carefully analyzed. In the present study, the results of two different simulation models are compared with experimental results. The comparisons showed that the simulation results by the Lumped model and by the Sectorial model did not show any partiality for the model used for the simulation. The simulation results according to the correlations show the various results in the large different range.

Cooling System with Nanofluidic Loop Thermosyphon (나노유체 루프형 열사이폰을 이용한 냉각장치)

  • Park Jong-Chan;Lim Taek-Kyu;Lee Chung-Gu;Shin Dong-Ryun;Park Gi-Ho;Rhi Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.3 s.246
    • /
    • pp.246-254
    • /
    • 2006
  • The present study shows the experimental and modeling results of the cooling system using nanofludic loop thermosyphon. the experimental results show that nanofluid is not effective for small scale cooling system. The heat transfer performance is not much improved with the current small scale loop system comparing with the convectional water based loop system. In this study, various effects of nanofluids such as the concentration, the md of particle, host fluid, and heat capacity and so on were investigated. With nanofluid as the working fluid, the flow instability was improved at a certain concentration.

Fuel Conversion to Renewable Energy Analysis of the Impact on the Horticulture in the Agricultural Sector -Mainly Wood Pellets- (농업부문에서 신재생에너지로의 연료전환이 시설원예에 미치는 영향 분석 -목재펠릿을 중심으로-)

  • Yoon, Sung-Yee;Kim, Tae-Hoon
    • Korean Journal of Organic Agriculture
    • /
    • v.22 no.4
    • /
    • pp.531-547
    • /
    • 2014
  • This study analyzed the effect of Greenhouse of wood pellet fuel conversing from Diesel. Analyzed through a life cycle assessment of greenhouse gas emissions of carbon dioxide for the environmental assessment, In evaluation of the Ministry of the Environment, analyzed through the life cycle assessment of carbon dioxide emissions of the greenhouse gas and, In the case of economic evaluation, we analyzed the investment payback period to the total revenue generated by each of the calculated incentive based on the RHI and institutions reduction projects a reduction of costs associated with the reduction of fuel costs.

Development of Multiclass Assignment For Dynamic Route Guidance Strategy (동적 경로안내전략수행을 위한 다계층 통행배정모형의 개발)

  • Lee, Jun;Lim, Kang-Won;Lee, Young-Ihn;Lim, Yong-Taek
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.7 s.78
    • /
    • pp.91-98
    • /
    • 2004
  • This study focuses on the development of dynamic assignment for evaluation and application for dynamic route guidance strategy. Travelers are classified according to information contents which they received pre/on trip. The first group have no traffic information, so they travel with fixed route. The second group have real-time shortest path and travel according to it. The last group have car navigation system or individual method(cellular phone, PDA-two way communication available) for traffic information on trip. And then they are assigned in accordance with the proposed multiclass dynamic assignment model. At this time the last group is gotten under control with DFS(decentralized feedback strategy). In use of this Process we expect that various traffic information strategy can be tested and also be the key factor for success of ITS, location of VMS(variable message sign), cycle of information, area of traffic information, etc).

Theoretical Analysis of Heat Transport Limitation in a Screen Mesh Wick Heat Pipe

  • Lee, Ki-Woo;Park, Ki-Ho;Lee, Wook-Hyun;Rhi, Seok-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • The purpose of the present study is to examine the heat transport limitations in a screen mesh heat pipe for electronic cooling by theoretical analysis. Diameter of pipe was 6mm, and mesh numbers were 50, 100, 150, 200 and 250, and water was investigated as working fluid. According to the change of mesh number, wick layer, inclination and saturation temperature, the maximum heat transport limitations by capillary, entraintment, sonic and boiling were analyzed by a theoretical design method of heat pipe, including capillary pressure, pumping pressure, liquid friction coefficient in wick, vapor friction coefficient, etc. Based on the results, the capillary limitation in a small diameter of heat pipe is largely affected by mesh number and wick layer. Mesh number of 250 is desirable not to be used in pipe diameter of 6 mm, because capillary heat transport limitation decreases by the abrupt increase of liquid friction pressure due to the small liquid flow area. For the heat transport of 15 watt in 6mm diameter pipe, mesh number of 100 and one layer is an optimum wick condition, which thermal resistance is the smallest.

Study on the Capillary Limitation in Copper-Water Heat Pipes with Screen Wicks

  • Park, Ki-Ho;Lee, Ki-Woo;Noh, Seung-Yong;Rhi, Seok-Ho;Yoo, Seong-Yeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • This paper is to study the heat transfer performance of the copper-water heat pipe with screen wicks. Recently, the semiconductor capacity of an electronic unit becomes larger, but its size becomes much smaller. As a result, a high- performance cooling system is needed. Experimental variables are inclination angles, temperatures of cooling waters and the mesh number of screen wicks. The distilled water was used as a working fluid. Based on the experimental results, when the copper-water heat pipe of 6mm diameter is used at the top heat mode, the heat transfer performance of 100 mesh 2 layers heat pipe is better than that of 150 and 200 mesh. The thermal resistance of the two layers with the 100-mesh screen was 0.7-$0.8^{\circ}C$/W.