Park, Mijung;Lee, Keum Hee;Lee, Eun Kyung;Park, Sang Hee;Kim, So Ra;Lee, Heum Sook
Journal of Korean Ophthalmic Optics Society
/
v.13
no.4
/
pp.43-49
/
2008
Purpose: The current study was conducted to evaluate the compatibility of UV-A blocking contact lens on eye protection with regular contact lens. Methods: The protective activity of regular contact lens (UV-A blocking: 20%) and UV-A blocking contact lens (UV-A blocking: 85%) on the denaturation of RNase A, catalase, and superoxide dismutase (SOD) induced UV-A irradiation were compared by acrylamide gel electrophoresis. The enzyme solutions were irradiated with UV-A for 1, 3, 6, 24 and 96 hours at the wavelength of 365 nm. Covering area with contact lenses were varied as 50%, 70% and 100% according to the calculation of blocking areas of anterior eye that could be covered with RGP lens, soft contact lens, and eye glasses, respectively. Results: Denaturations of RNase, catalase and SOD were exaggerated when they were exposed to UV-A for a longer period. The denaturation was effectively prevented by UV-A blocking contact lens compared to regular contact lens. The capability of UV-A blocking contact lens was considerably reduced when the covering area with contact lens decreased and exposure time to UV-A extended. Conclusion: Therefore, it would be suggested that wearing contact lens for a long time under sunlight is carefully considered since the activity of UV-A blocking contact lens against UV-A irradiation may not be enough to protect enzymes presented in eyes when exposure time to UV-A increased.
Purpose: This study is for compared the change of corneal refractive power before and after wearing of rigid gas permeable contact lense with diagnostic method which is 1 D flatter than alignment fitting on right eye and alignment fitting on left eye for 2 months and investigate the preference. Methods: Twenty middle school and high school students (40 eyes) who had never worn a contact lense before for no corneal topographical change, no ocular disease, no experience of ophthalmic surgery and have normal tear amount were selected for this study and corneal refractive power were examined before wearing rigid gas permeable contact lense and adaptation status and corneal examination were performed after 10 days of wearing and after cheking up the continuation of wearing, all candidate wear contact lens 8 hours per day for 2 month and corneal refractive power were compared. Results: After 2 months of wearing with 1 D flatter than the alignment fitting on right eyes, there was significant difference in the central corneal refractive power was $43.84{\pm}1.33D$, flat K power was $43.05{\pm}1.29D$, and steep K power was $44.61{\pm}1.42D$ decreased than before wearing (p<0.001, 0.001, 0.047). The e-value of the principal meridians also shows statistically significant difference (p=0.037, 0.015). After 2 months of wearing with alignment fitting on left eyes, the central corneal refractive power was $44.40{\pm}1.26D$, flat K power was $43.57{\pm}1.23D$. and flat K e-value was $0.58{\pm}0.05$ which showed no statistically significant difference (p = 0.769, 0.614, 0.181). But steep K power was $45.25{\pm}1.36$, and steep K e-value was $0.45{\pm}0.18$ which shows statistically significant difference (p=0.018, 0.027). Conclusions: Consider the comfort, clear vision, dryness for preference fitting investment, 6 students (30%) prefer right eye which is 1 D flatter fitting, 14 students (70%) prefer left eye which is alignment fitting. For rigid gas permeable fitting needed for accurate examination and should prescribe the alignment fitting which is suitable for each cornea.
We performed refraction, keratometry, slit lamp biomicroscopy. We selected 58 current spherical RGP lens wearers for this three-month study. All patients exhibits at least 0.75D of corneal astigmatism measured with the keratometer, and 37 patients had corneal astigmatism of 1.50D or greater. At least follow-up visit, we measured Snellen acuity with lenses, and performed overrefraction, overkeratometry and slit lamp biomicroscopy. We charted lens position, movement and surface quality. During the three month, biomicroscopy revealed no corneal edema and neovascularization on any patients. Fluorescein staining were 52 patients case of grade 0.5 patients case of grade 1, and 1 patient case of grade 2. In evaluating post-fit residual cylinder, on overrefraction as a percentage of refractive cylinder. By the initial visit, one-week visit, one-month visit, and two-month visit are 41%, 34%, 29%, respectively. In this data, we knew no change after one month. The average overrefraction for these eyes in absolute diopters is 0.26D(initial visit), 0.22D(one-week visit, 0.17D(one-month visit), and 0.16D(two-month visit). The use of a regimen containing a dedicated daily cleaner was more effective in maintaining patient comfort and lens cleanliness than was the use of a regimen containing only a multipurpose solution.
We measured the effect of wettability of six MPSs for RGP(rigid gas permeable) lens. The used MPSs(multipurpose solutions) were OPTI-SOAK(ALCON), SOLO care hard(CIBA Vision), Total care(ALLERGAN), Simplicity(BOSTON), Wetting and Soaking Sol.(Bausch & Lomb) and Aquas-multi(Saehan). These MPSs keeps hydrophilic property of lens surface and increase the effect of cleaning or increase the effect of preservative effect. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. The results showed that every lens was nearby hydrophilic property within $25\;^{\circ}-36\;^{\circ}$. Also, it was differed by various factors. The surface tension showed various differences between 19.8 and 31.3 mN/m. In the viscosity, MPSs represented the highest viscosity between $4^{\circ}C$ and $20^{\circ}C$. It was much higher than compared with the viscosity of soft lens MPS. This experiment could be used to grasping the interaction between solutions used to MPS and the natural endowments of lens and to considering the relations of different factors effecting the wettability.
The measurement of the radius of corneal curvature with keratometer was followed in 184 university students who wearing RGP contact lens and consisted of female(167), male(17) and keratoconus patients(3). Overall mean value in the radius of corneal curvature is 7.77mm, and right and left eyes is appeared the same mean value. Overall mean value in horizontal and vertical is 7.88mm and 7.65mm. Horizontal means is larger than vertical means by 0.22mm of the all female and male students. Male's mean value in the radius of corneal curvature(7.84mm) is larger than female's by 0.08mm, and right and left eyes is also the same mean value. Keratoconus patients' mean value in the radius of corneal curvature(6.86mm) is smaller than others students by 0.91mm.
Kim, Young-Hoon;Baarg, Saangbai;Kim, Kwang-Bae;Kim, Dae-Hyoun;Lim, Byung-Kwan;Sun, Kyoung-Ho
Journal of Korean Ophthalmic Optics Society
/
v.12
no.3
/
pp.7-17
/
2007
There has been an increase in rigid gas permeable contact lens prescription by the optometrists in Korea since 1995. Therefore, the aim of our study was to find out which equipment is needed for adequate RGP contact lens prescription and the level of the clinical knowledge that they have and the level of education for the patient, to seize about the extended lens education programmes for the Korean optometrist. Also, we tried to figure out the problem that they had in the RGP contact lens prescription, to develope the educational programs for students and to improve legal uncertainties, through this research. The result came out with the following through questionnaires of 400 male and female opticians who is in clinical field. The distributions of respondents are 270 male (67.5%), 130 female (32.5%), and 356 optometry major (89%). We found out the optometry-majored people had faster clinical lens prescriptions (p=0.000), 72.5% of opticians prescribe the RGP-Lenses, and 27.5% do not because of laking in experience (P=0.000). They responded that they need slit-lamp, button lamp, fluorescein dry paper, and etc,for prescription or fitting test. In regular-check-up (Follow-up), the result came out very low by 83% of respondents who are not getting it regularly. And 83.5% (334 people) of them wanted to have those Extended Educational Programs and also the Clinical Education Programs.
Park, Hyun-Ju;Goe, Eun-Kyung;Seo, Eun-Sun;Kim, Jai-Min;Lee, Ki-Young
Journal of Korean Ophthalmic Optics Society
/
v.8
no.2
/
pp.119-127
/
2003
We measured the effect of wettability of six MPSs for RGP lens. The used MPSs(multipurpose solutions) were OPTI-SOAK(ALCON), SOLO care hard(CIBA Vision), Total care(ALLERGAN), Simplicity(BOSTON). Wetting and Soaking Sol.(Bausch & Lomb) and Aquas-multi(Saehan). These MPSs keeps hydrophilic property of lens surface and increase the effect of cleaning or increase the effect of preservative effect. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. The results showed that every lens was nearby hydrophilic property within $25^{\circ}{\sim}36^{\circ}$. Also, it was differed by various factors. The surface tension showed various differences between 19.8 and 31.3(mN/m). In the viscosity, MPSs represented the highest viscosity between $4^{\circ}C$ and $20^{\circ}C$. It was much higher than compared with the viscosity of soft lens MPS. This experiment could be used to grasping the interaction between solutions used to MPS and the natural endowments of lens and to considering the relations of different factors effecting the wettability.
The Hydroxyethyl methacrylate(HEMA) was developped in 1960's and later the use of contact lenses increased. At present more and more people use RGP contact lenses. Due to the wide range of optical corrections available and due to their high oxygen transmission Japanese and Korean people like them. Nevertheless one of nine CL users(beginners) stopped wearing the CL within the first year. We conducted a survey to evaluate the level of patient compliance in lens care and maintenance and to assess practitioner knowledge of contact lens information. Generally 6% of contact lens wearers drop out per year. The aim of this research was to find out what opticians can do to reduce the drop-out rate by getting information on handling, on general data of the patient and on optical prescription. Lens wearer were asked to complete a 10 question survey that focused on lens care-wear modality, lens replacement, storage, symptoms and case disinfection. There were total 180 participants in the study. Most of contact lens wearers have an inadequate understanding of contact lens care system. Therefore, it is important that contact lens specialists place more emphasis on practitioner education about general contact lens fields and reinforce patient education during the dispensing visit.
Purpose: The purpose of this study is to investigate the changes of asphericity according to diameter and direction of the cornea. Methods: The changes of asphericity according to diameter and direction of cornea is measured by using Pentacam(Oculus Co., Germany), as targeting 57 adults (average $27.0{\pm}4.8$, 20 men, 37 women) without any ophthalmic diseases, which may be effective in eyesight, and refractive surgery. Results: As diameter increases in every direction based on the corneal vertex, asphericity has attentively increased (p<0.05), and the size of asphericity in each direction from every measured diameter showed as superior > nasal > inferior > temporal. In group comparison by nearsightness and astigmatism level, asphericity measured high when nearsightness and astigmatism levels were higher, and this appears to be statistically attentive.(p<0.05). Conclusions: Asphericity of cornea significantly increased according to increase of diameter of cornea, and as measured figure or increased quantity appeared differently in all directions based on corneal vertex, so it helps to understand shape of cornea, and considered that is the part to be considered during manufacturing and fitting of RGP lenses.
Kim, So Ra;Gil, Ji-Yeon;Park, Chang Won;Kim, Ji Hye;Park, Mijung
Journal of Korean Ophthalmic Optics Society
/
v.16
no.3
/
pp.273-281
/
2011
Purpose: In order to provide the fundamental information for the design development of RGP lenses and its clinical prescription, the corneal types of Korean twenties were analyzed according to corneal shapes, astigmatic degree, and the certain distance from the corneal apex. Methods: Corneal types of total 252 eyes in 20s were firstly classified, then their corneal radii from the certain distance from the corneal apex were measured by corneal topography and further analyzed based on the astigmatic degree. Results: Korean 20s' corneal types were classified as 14.3%(36 eyes) of round, 31.3%(79 eyes) of oval, 28.6%(72 eyes) of symmetric bow tie, 17.5%(44 eyes) of asymmetric bow tie, 8.3%(21 eyes) of irregular shapes. The round and oval typed corneas had mild astigmatic degree whereas the higher astigmatic degree in symmetric and asymmetric bow tie typed corneas were shown. The relative corneal radii of round and oval typed corneas at each distance from corneal apex were shown to consistently increase regardless of astigmatic degrees when they measured at certain distances from the corneal apex. However, the relative corneal radii of symmetric and asymmetric bow tie typed corneas within 1.0-1.5mm from the corneal apex were decreased, which showed steeper slope than it within 1.0 mm and somewhat different based on astigmatic degrees. Bigger change of corneal radii outer 3.5 mm from the corneal apex in symmetric bow tie typed corneas with astigmatism of 1.50-2.00 D and 2.25-2.75 D appeared. Conclusions: The consideration of radial change from the central cornea to peripheral cornea is necessary for manufacturing RGP lens and its prescription since they showed different change in corneal radii by corneal patterns and astigmatic degrees.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.