• Title/Summary/Keyword: RF-type

Search Result 841, Processing Time 0.025 seconds

A Study of Thin Film deposition using of RF Magnetron Sputtering (RF 마그네트론 스퍼터링을 이용한 박막 증착에 관한 연구)

  • Lee, Woo Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.6
    • /
    • pp.772-777
    • /
    • 2018
  • This paper used RF Magnetron Sputtering to deposition n-type and p-type to ITO glass. The N-type ohmic contact worked well under all conditions. Sheet resistance has been shown to increase sheet resistance as RF Power increases. After analyzing the surface of the deposited thin film, in the condition that RF Power was 250W and substrate temperature was $250^{\circ}C$, particles were measured to have a uniform and consistent thin film. P-type has good ohmic contact under all conditions and sheet resistance has been shown to increase as RF Power increases. As the RF Power grew, thickness increased and stabilized. PN junction thin film and NP junction thin film showed increased thickness and stabilized as sputtering time increased. As a result of thin film, conversion efficiency was at 0.2 when sputtering time was 10 minutes.

FDTD 방법을 이용한 3T MRI용 RF 코일의 해석

  • 이종오;박준서;명노훈;박부식;김용권;정성택
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.6
    • /
    • pp.976-983
    • /
    • 2000
  • In this paper, Bridcage type RF coils used widely as RF coils for MRI and its applicable type, spiral type RF coil are analyzed and designed using FDTD method. In low tesla (IT, 1.5T) MRI system, several tools have been used for the analysis and design of the RF coils for MRI. This includes, so-called, LC equivalent circuit method for predicting the resonance frequency of the coil and the Biot-Savart law to determine the field distribution within the coil. Both of the circuit analysis and Biot-Savart law are low frequency techniques. Therefore, at high frequency applications, the circuit model approximation breaks down because the coil geometry is a significant fraction of the wavelength. In this paper, we analyzed and designed RF coils for 3T MRI using FDTD method. This method is a full wave analysis and very accurate at low and high frequencies. Also, this RF coils are actually fabricated and FDTD models of RF coils for MRI are proven.

  • PDF

Simulation Method for Radio-Frequency Single-Electron Transistor (RF-SET) Operation (고주파 단일전자 트랜지스터 (RF-SET) 동작의 시뮬레이션 방법)

  • Yu Yun Seop;Park Hyun-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.5 s.335
    • /
    • pp.9-14
    • /
    • 2005
  • Simulation method for a pure radio-frequency (rf) mode of reflection-type and a pure rf mode of transmission-type radio-frequency single-electron transistor (RF-SET) operation is introduced. In this method, the solutions of differential equations based on Kirchhoff's law are obtained self-consistently at frequency-domain. Also, the steady-sate single-electron transistor (SET) current model and the time-dependent SET current model are used in this method. The reflected wave of a typical reflection-type RF-SET and the transmitted wave of a typical transmission-type RF-SET are calculated, and the accuracy of our developed method including the steady-state SET current model is verified with the method introduced by reference 2. At high frequency over GHz, results of our developed method including the time-dependent SET current model are considerably different from that including the steady-state SET current model. At high frequency over GHz, an exact time-dependent SET current model is needed to analyze RF-SET operation.

A Study on Impurity Deposition using of ITO Substrate (ITO기판을 이용한 불순물 증착에 관한 연구)

  • Park, Jung-Cheul;Chu, Soon-Nam
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.231-238
    • /
    • 2015
  • In this paper, we have studied a sheet resistance property of N- and P-type thin films deposited on ITO glass by use of RF magnetron sputtering. The N-type samples which has the deposition condition of 150W RF power, shows the highest current value, and the samples deposited for 15 minutes shows a better Ohmic contact property. As the substrate temperature, RF power and deposition time are increased, the sheet resistance of the samples is increased, and the low sheet resistance sample shows a better I-V property. The P-type samples shows the highest current value by 150W RF power condition as similar as N-type samples. and the samples deposited for 20 minutes shows a better ohmic contact property. The sheet resistance of the both types samples is increased as increasing RF power and deposition time.

On-chip ESD protection design by using short-circuited stub for RF applications (Short-Circuited Stub를 이용한 RF회로에서의 정전기 방지)

  • 박창근;염기수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.288-292
    • /
    • 2002
  • We propose the new type of on-chip ESD protection method for RF applications. By using the properties of RF circuits, we can use the short-circuited stub as ESD protection device in front of the DC blocking capacitor Specially, we can use short-circuited stub as the portion of the matching circuit so to reduce the and various parameters of the transmission line. This new type ESD protection method is very different from the conventional ESD protection method. With the new type ESD protection method, we remove the parasitic capacitance of ESD protection device which degrade the performance of core circuit.

  • PDF

Development of an Improved RF Dosimeter (개량된 비접촉형 RF 선량계 구현)

  • Son, Jong-Dea;Lee, Seung-Min;Lee, Heung-Ho;Lee, Nam-Ho;Lee, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.540-543
    • /
    • 2003
  • This paper presents design and manufacture of RF type non-contact radiological dosage measuring device. It also concerns on the broad out-line and the ways of improvement about RF type non-contact radiation measuring device. Measuring radiological dosage with non-contact RF, the stability and efficiency of the measure have been improved by reforming constant current circuit. Furthermore, applying communication protocol in process makes it possible to achieve faster and more accurate communication than old circuit. On the base of those, RF type non-contact radiological dosage measuring device which consists of radiological dosage measuring module and Reader module has been designed and manufactured. While testing communication against embodied device, the possibility of the field application could be confirmed.

  • PDF

A Study of Impurity Deposition on ITO Substrate using RF Magnetron Sputtering (RF 마그네트론 스퍼터링을 이용한 ITO 기판에 불순물 증착에 관한 연구)

  • Park, Jung-Cheul;Chu, Soon-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.277-280
    • /
    • 2015
  • In this paper, we have studied the surface property and transmittance of n- and p-type thin film deposited on ITO substrate. In n-type samples, the average particle size was large and uniform as RF power was increased, and the best results were shown at the condition of the temperature of $300^{\circ}C$ and 200 W of RF power. The transmittance of the sample deposited for 20 minutes was 74.82% and the light wave was increased to 800 nm. In p-type samples, the results were 71.21% and 789 nm at the deposition condition of the RF power of 250 W and the temperature of $250^{\circ}C$.

A Study for Solenoid-Type RF Chip Inductors (솔레노이드 형태의 RF 칩 인덕터에 대한 연구)

  • 김재욱;윤의중;정여창;홍철호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.840-846
    • /
    • 2000
  • In this work, small-size, high-performance solenoid-type RF chip inductors utilizing a low-loss Al$_2$O$_3$core material were investigated. The size of the chip inductors fabricated in this work were 15$\times$10$\times$0.7㎣, 2.1$\times$1.5$\times$10㎣, and 2.4$\times$2.0$\times$1.4㎣ and copper (Cu) wire with 40 ㎛ diameter was used as the coils. High frequency characteristics of the inductance, quality factor, and impedance of developed inductors were measured suing an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). It was observed that the developed inductors with the number of turns of 7 have the inductance of 33 to 100nH and exhibit the self-resonant frequency (SRF) of .26 to 1.1 GHz. The SRF of inductors decreases with increasing the inductance and the inductors have the quality factor of 60 to 80 in the frequency range of 300 MHz to 1.1 GHz. In this study, small-size solenoid-type RF chip inductors with high inductance and high quality factor were fabricated successfully. It is suggested that the thin film-type inductor is necessary to fabricate the smaller size inductors at the expence of inductance and quality factor values.

  • PDF

Studies on the Alcohol Dehydrogenase ( ADH ) and Esterase Isozyme banding Pattern of Italian Ryegrass Varieties (이탈리안 라이그라스의 품종별 Alcohol Dehydrogenase ( ADH ) 와 Esterase의 Isozyme Banding Pattern에 관한)

  • 이성규;박병훈
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.14 no.2
    • /
    • pp.82-87
    • /
    • 1994
  • This study was planned to identify the variety of Italian ryegrass using electrophoresis. Thirty seven varieties of Italian ryegrass were tested by starch gel electrophoresis. The specific electrophoretic zymograms of each variety were observed by Alcohol dehydrogenase(ADH) and Esterase. The results were surnrnerized as follows; 1. AU varieties displayed two band zones by ADH and Rf values were 0.63 and 0.6 (Table 2, Fig. 2). 2. There were five band type for ADH isozyme of 37 varieties classified with isozyme banding pattern. According to the isozyme band type 7, 2, 6, 18 and 4 varieties belong to group, I, II, III, IV, and V, respectively (Table 2). 3. The varieties displayed single band zone for Esterase isozyme and Rf value was 1.00 (Table 2, Fig. 4). 4. According to banding type, Esterase isozyme of 37 varieties classified into 3 groups, 22, 8 and 7 varieties belong to group, I , II, and III, respectively (Table 2).

  • PDF

Development of Microscale RF Chip Inductors for Wireless Communication Systems (무선통신시스템을 위한 극소형 RF 칩 인덕터의 개발)

  • 윤의중;김재욱;정영창;홍철호
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.10
    • /
    • pp.17-23
    • /
    • 2003
  • In this study, microscale, high-performance, solenoid-type RF chip inductors were investigated. The size of the RF chip inductors fabricated in this work was 1.0${\times}$0.5${\times}$0.5㎣. The materials (96% Al2O3) and shape (I-type) of the core were determined by a Maxwell three-dimensional field simulator to maximize the performance of the inductors. The copper (Cu) wire with 40${\mu}{\textrm}{m}$ diameter was used as the coils. High frequency characteristics of the inductance (L), quality-factor (Q), and capacitance (C) of developed inductors were measured using an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). The inductors developed have inductances of 11 to 39 nH and quality factors of 28 to 50 over the frequency ranges of 250MHz to 1 GHz, and show results comparable to those measured for the inductors prepared by CoilCraf $t^{Tm}$ that is one of the best chip inductor company in the world. The simulated data predicted the high-frequency data of the L, Q, and C of the inductors developed well.l.