• Title/Summary/Keyword: RF test

Search Result 697, Processing Time 0.03 seconds

Alteration of Endogenous Growth Substances in Cold-moist Stratified Seeds of Ginkgo biloba L. (냉습적(冷濕積)에 따른 은행나무종자내(種子內) 생장조정물질(生長調整物質)의 변화(變化))

  • Lee, Kyong Jae;Yim, Kyong Bin
    • Journal of Korean Society of Forest Science
    • /
    • v.38 no.1
    • /
    • pp.1-12
    • /
    • 1978
  • This study has intended to disclose the change of some chemical compositions of Ginkgo seeds which were acquired the treatment of cold-moist-stratification after collection. As check sample, the room-stored seeds were used. With the reasons that when the seeds not stratified were sown the delay of field germination has usually been resulted, the effectiveness of stratificaation in respect to alteration of chemical composition is to be investigated. The increase and decrease of growth promoting and inhibiting substances were investigated by means of chromatography method followed by rice seedling test or wheat coleoptile straight-growth test. The results obtained are summarized as follows; 1. In the untreated seeds, the zone of growth inhibitors on paper chromatograph were observed without regard to the tissue differences, embryo, endosperm and seedcoat. 2. Due to stratification, the amount of inhibitor has decreased in the embryo and seed coat, but growth promoters was decreased as compared with the check materials 3. The indications of results appear that each portion of the embryo, endosperm, and seedcoats of Ginkgo biloba L. contains the growth in hibitor taking part in germination dormancy. 4. It was presumed that hastening germination was influenced by decreasing of inhibitors in the embryo and seed coats rather than by increasing of promoters. 5. Gibberellin was detected at Rf 0.26 under the UV-lamp and the abscisic acid was detected at Rf 0.62, Rf 0.70, and Rf 0.78 and showed purple, gray, blue fluorescence respectively under the UV-lamp.

  • PDF

Design of a High Dynamic-Range RF ASIC for Anti-jamming GNSS Receiver

  • Kim, Heung-Su;Kim, Byeong-Gyun;Moon, Sung-Wook;Kim, Se-Hwan;Jung, Seung Hwan;Kim, Sang Gyun;Eo, Yun Seong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.4 no.3
    • /
    • pp.115-122
    • /
    • 2015
  • Global Positioning System (GPS) is used in various fields such as communications systems, transportation systems, e-commerce, power plant systems, and up to various military weapons systems recently. However, GPS receiver is vulnerable to jamming signals as the GPS signals come from the satellites located at approximately 20,000 km above the earth. For this reason, various anti-jamming techniques have been developed for military application systems especially and it is also required for commercial application systems nowadays. In this paper, we proposed a dual-channel Global Navigation Satellite System (GNSS) RF ASIC for digital pre-correlation anti-jam technique. It not only covers all GNSS frequency bands, but is integrated low-gain/attenuation mode in low-noise amplifier (LNA) without influencing in/out matching and 14-bit analogdigital converter (ADC) to have a high dynamic range. With the aid of digital processing, jamming to signal ratio is improved to 77 dB from 42 dB with proposed receiver. RF ASIC for anti-jam is fabricated on a 0.18-μm complementary metal-oxide semiconductor (CMOS) technology and consumes 1.16 W with 2.1 V (low-dropout; LDO) power supply. And the performance is evaluated by a kind of test hardware using the designed RF ASIC.

Design of RF coupler for KIRAMS-13;Korea Institute of Radiological & Medical Sciences-13

  • Jung, In-Su;An, Dong-Hyun;Kim, Yu-Seok;Yang, Tae-Gun;Kim, Jea-Hong;Jang, Hong-Seok;Hong, Bong-Hwan;Lee, Min-Yong;Hong, Sung-Seok;Chai, Jong-Seo;Oh, Bong-Hun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2203-2205
    • /
    • 2003
  • KIRAMS-13, the first medical cyclotron developed by domestic technique, is used to produce radio-isotope such as $^{18}F$ whose life time is relatively short through test operation. For high-power operation of charged particle accelerators, the power coupler must withstand enormous stresses due to charging induced by high RF power passing through. High-power RF testing with peak power in excess of 30kW has been performed on prototype power coupler for KIRAMS-13 normal conducting cavities. CST MICROWAVE STUDIO(CST MWS) is used for fundamental RF Design, and power coupler is manufactured according to fundamental power coupler design requisite. The qualification of the couplers has occurred for the time being only in a limited set of conditions as the available RF system and control instrumentation are under improvement.

  • PDF

The Optimum Structure Design of 1005 RF Chip Inductors for GHz Band (GHz 대역을 위한 1005 RF 칩 인덕터의 최적 구조 설계)

  • Kim, Jae-Wook;Ryu, Chang-Keun
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.785-788
    • /
    • 2005
  • In this study, micro-scale, high-performance, solenoid-type RF chip inductors were investigated. The size of the RF chip inductors fabricated in this work was $1.0{\times}0.5{\times}0.5mm^3$ The material and shape of the core were 96% $Al_2O_3$ and I-type. The material and number of turn of coil were copper (Cu) and 6. The diameter ($40{\mu}m$) of coil and length (0.35mm) of solenoid were determined by a Maxwell three-dimensional field simulator to maximize the performance of the inductors. High frequency characteristics of the inductance (L) and quality-factor (Q) of developed inductors were measured using an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). The inductors developed have inductances of 10.8nH and quality factors of 25.2 at 250MHz, and show results comparable to those measured for the inductors prepared by CoilCraftTm that is one of the best chip inductor company in the world. The simulated data predicted the high-frequency data of the Land Q of the inductors developed well.

  • PDF

Development Status of High Enthalpy Plasma Equipment (전북대 고온플라즈마 설비 구축 및 응용연구 소개)

  • Choi, Chea-Hong;Lee, Mi-Yun;Kim, Min-Ho;Hong, Bong-Guen;Seo, Jun-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.694-696
    • /
    • 2011
  • The high enthalpy plasma research center in Chonbuk national university is under construction for four types of plasma equipments. The equipments are 1set of 0.4 MW class enhanced Huels type plasma equipment, 1 set of 2.4 MW class enhanced Huels type plasma quipment, 1 set of 60 kW RF plasma equipment and 1 set of 200 kW RF plasma equipment. 60kW RF plasma system is R&D and pilot scale production equipment of nano powder synthesis and plasma spray coating. 200kW RF plasma system is mass production equipment with high power capacity of nano powder synthesis. 0.4MW plasma system can be applied to the ground test facility for material testing under re-entry conditions for space vehicles.

  • PDF

RF MEMS 기법을 이용한 US PCS 대역 FBAR BPF 개발

  • 박희대
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.3
    • /
    • pp.15-19
    • /
    • 2003
  • In This paper, we developed 1.96 GHz air gap type FBAR BPF using ZnO as piezoelectric sputtered by RF magnetron at room temperature. FBAR BPF was fabricated by sputtering bottom electrode (Al), ZnO as piezoelectric and top electrode (Mo) on Si wafer one by one with RF magnetron sputter, then Si was dry etched to make an air hole. XRD test result of fabricated FBAR BPF showed that ZnO crystal was well pre-oriented as (002) and sigma value of XRC was 1.018. IL(Insertion loss) showed excellent result as 1 dB.

The Design of Image Rejection Mixer (이미지 제거 혼합기의 설계)

  • Kang, Eun Kyun;Jeon, Hyung Jun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.123-127
    • /
    • 2017
  • This paper fabricated and analyzed the image rejection mixer that uses FET's channel resistance. It can be applied for capacity 64QAM that has 50MHz~90MHz of IF band, 8.17GHz of LO frequency and 8.08~8.12GHz of RF band. When IF input power is -20dBm and LO input power is 10dBm, RF output power is obtained -33.2dBm. In this case, conversion loss is 12.9dB, the suppression of 14.3dB for LO frequency and 10.4dB for image frequency. The result of two tone test shows great IMD characteristics with 51.7dBc.

A Novel Predistorter design using a Balanced Type IM3 Generator (평형 구조 혼변조 발생기를 이용한 전치왜곡 선형화기 설계)

  • 정형태;김상원;김철동;장익수
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.2
    • /
    • pp.65-70
    • /
    • 2004
  • This paper presents a novel linearization scheme for a nonlinear RF amplifier It is based on the amplitude modulation with envelope signal. The 3rd order distortion generator is composed of two FETs and it adopts a balanced structure for the purpose of main carrier cancellation. The amplitude and phase of the IM3 component can be controlled at RF band. This predistorter is implemented and tested at the KOREA PCS Tx. band (1840∼1870MHz). Experimental results of two-tone test show that the IM3 cancellation is achieved about 30-40 ㏈ for the wide dynamic range. The adjacent channel power ratio is improved by over 10 ㏈ at the broad-band CDMA signal with a peak to average power ratio of l0㏈, and this improvement is maintained through a wide range of output power levels.

The Status of the High Enthalpy Plasma Test Facility in Chonbuk National University (전북대 고온플라즈마 설비 구축현황)

  • Choi, Seong-Man;Shin, Eui-Sup;Suh, Young-Sug;Seo, Jun-Ho;Hong, Bong-Geun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.417-420
    • /
    • 2010
  • The high enthalpy plasma research center in Chonbuk national university is under construction with the support of the ministry of the education, science and technology as a fundamental research project The project periods are five year and started at July, 1, 2009. The total project budget is about 39,300 million Won. Four types of plasma equipment will be installed in this research center during the project periods. The equipments are 1 set of 0.4 MW class enhanced Huels type plasma equipment, 1 set of 2.4MW class enhanced Huels type plasma equipment, 1 set of 60Kw RF plasma equipment and 1s set of 200 kW RF plasma equipment.

  • PDF

Passive and Cost Effective People Indoor Location Tracking System for Ubiquitous Healthcare (유비쿼터스 헬스케어를 위한 저비용, 수동형 실내 위치추적 시스템)

  • Chung Wan-Young;Singh Vinay Kumar;Lim Hyo-Taek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.6
    • /
    • pp.1119-1123
    • /
    • 2006
  • Wireless sensor network plays a prominent role in tracking the location of the target outdoor or indoor. This paper describes the implementation of the passive indoor location tracking system using ultrasonic and RF technologies that provides accurate location in the form of user space and position in three dimensions. Our system used a combination of RF and ultrasonic technologies to provide a location-support service to users and applicants. Ceiling-mounted beacons were spread through the building, publishing location information on an RF signal. The person carried a listener and the listener determined the location by calculating the distance from three beacons using triangulation algorithm.