• Title/Summary/Keyword: RF motion sensor

Search Result 15, Processing Time 0.03 seconds

Implementation of the Hand-motion Recognition based Auxiliary Input Device using Gyro Sensor (자이로센서를 이용한 손 동작 인식형 보조 입력장치 구현)

  • Park, Ki-Hong;Lee, Hyun-Jik;Kim, Yoon-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2009
  • In this paper, we have designed the auxiliary input device which based on hand-motion recognition. It is aimed at some individually specified person such as the disabled, rehabilitation patient, and the aged. The gyro sensor is used to recognize the hand-motion in 3D space, and communication bandwidth for transceiver is also set to the 2.4GHz. Prototype board includes a set of modules; Gyro sensor, RF transmitter/receiver, MCU for signal processing and USB connector etc. Some experiments are conducted so as to verify the prototype, and as a result, mouse-based curser motion as well as program control are well operated just same as the design specification.

  • PDF

An Intelligent Wireless Camera Surveillance System with Motion sensor and Remote Control (무선조종과 모션 센서를 이용한 지능형 무선감시카메라 구현)

  • Lee, Young-Woong;Kim, Jong-Nam
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.672-676
    • /
    • 2009
  • Recently, intelligent surveillance camera systems are needed popularly. However, current researches are focussed on improvement of a single module rather than implementation of an integrated system. In this paper, we implemented a wireless surveillance camera system which is composed of face detection, and using motion sensor. In our implementation, we used a camera module from SHARP, a pair of wireless video transmission module from ECOM, a pair of ZigBee RF wireless transmission module from ROBOBLOCK, and a motion sensor module (AMN14111) from PANASONIC. We used OpenCV library for face dection and MFC for implement software. We identified real-time operations of face detection, PTT control, and motion sensor detecton. Thus, the implemented system will be useful for the applications of remote control, human detection, and using motion sensor.

  • PDF

An Intelligent Moving Wireless Camera Surveillance System with Motion sensor and Remote Control (무선조종과 모션 센서를 이용한 지능형 이동 무선감시카메라 구현)

  • Lee, Young Woong;Kim, Jong-Nam
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.661-664
    • /
    • 2009
  • Recently, intelligent surveillance camera systems are needed popularly. However, current researches are focussed on improvement of a single module rather than implementation of an integrated system. In this paper, we implemented a moving wireless surveillance camera system which is composed of face detection, and using motion sensor. In our implementation, we used a camera module from SHARP, a pair of wireless video transmission module from ECOM, body of moving robot used for A4WD1 Combo kit for RC, a pair of ZigBee RF wireless transmission module from ROBOBLOCK, and a motion sensor module (AMN14111) from PANASONIC. We used OpenCV library for face dection and MFC for implement software. We identified real-time operations of face detection, PTT control, and motion sensor detecton. Thus, the implemented system will be useful for the applications of remote control, human detection, and using motion sensor.

  • PDF

Real-time 3-Dimensional Measurement of Lumbar Spine Range of Motion using a Wireless Sensor (무선 센서를 활용한 요추 가동 범위의 실시간 3차원 측정)

  • Jeong, Woo-Hyuk;Jee, Hae-Mi;Park, Jae-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.8
    • /
    • pp.713-718
    • /
    • 2012
  • Lumber spine range of motion has been used to measure of physical and functional impairment by various tools from a ruler to 3D kinematic devices. However, pre-existing tools have problems in either movement or accuracy and reliability limitations. Accurate devices are limited by fixed space whereas simple devices are limited in measuring complex movements with less accuracy. In order to solve the location, movement and accuracy limitations at once, we have developed a novice measurement device equipped with accelerometer sensor and gyroscope sensor for getting three-dimensional information of motion. Furthermore, Kalman filter was applied to the algorithm to improve accuracy. In addition, RF wireless communication was added for the user to conveniently check measured data in real time. Finally, the measurement method was improved by considering the movement by a reference point. An experiment was conducted to test the accuracy and reliability of the device by conducting a test-retest reliability test. Further modification will be conducted to used the device in various joints range of motion in clinical settings in the future.

MEMS Embedded System Design (MEMS 임베디드 시스템 설계)

  • Hong, Seon Hack
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.18 no.4
    • /
    • pp.47-54
    • /
    • 2022
  • In this paper, MEMS embedded system design implemented the sensor events via analyzing the characteristics that dynamically happened to an abnormal status in power IoT environments in order to guarantee a maintainable operation. We used three kinds of tools in this paper, at first Bluetooth Low Energy (BLE) technology which is a suitable protocol that provides a low data rate, low power consumption, and low-cost sensor applications. Secondly LSM6DSOX, a system-in-module containing a 3-axis digital accelerometer and gyroscope with low-power features for optimal motion. Thirdly BM1422AGMV Digital Magnetometer IC, a 3-axis magnetic sensor with an I2C interface and a magnetic measurable range of ±120 uT, which incorporates magneto-impedance elements to detect the magnetic field when the current flowed in the power devices. The proposed MEMS system was developed based on an nRF5340 System on Chip (SoC), previously compared to the standalone embedded system without bluetooth technology via mobile App. And also, MEMS embedded system with BLE 5.0 technology broadcasted the MEMS system status to Android mobile server. The experiment results enhanced the performance of MEMS system design by combination of sensors, BLE technology and mobile application.

Context Awareness Using Wireless Biosignal Processing (무선 생체신호 처리를 이용한 상황인식)

  • Lee Sang-Bock;An Byung-Ju;Lee Sanyol;Lee Jun-Haeng
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.6 s.38
    • /
    • pp.117-126
    • /
    • 2005
  • In this paper, it was suggested method to recognize the motion of a person(lying, sitting, walking, running) using fuzzy inference and wireless biologic signal processing system. These are to Perceive the motion of the person. Furthermore, the information of motion is indispensable parameter for Context Awareness (CA). In the present study, ADXL 202JE accelerometer sensor was used to measure for checking the continuance motion, biological quantify of motion, and motion pattern of a Person. The measured data was transmitted to CA server by Radio Frequency(RF). From the present result, we confirmed that it is difficult to decide the motion of walking and running with only the magnitude of the Longitudinal Accelerometer Average Value(LAAV) and moreover the covariance of LAAV in any block is very useful for CA of walking and running.

  • PDF

Design of ECG/PPG Gating System in MRI Environment (MRI용 심전도/혈류 게이팅 시스템 설계)

  • Jang, Bong-Ryeol;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.132-138
    • /
    • 2007
  • MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

Localization of a High-speed Mobile Robot Using Ultrasonic/RF Sensor and Global Features (RF/초음파센서와 이동특성에 기반한 고속 이동로봇의 위치추정기법)

  • Lee, Soo-Sung;Choi, Mun-Gyu;Park, Jae-Hyun;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.7
    • /
    • pp.734-741
    • /
    • 2009
  • A new localization algorithm is proposed for a fast moving mobile robot, which utilizes only one beacon and the global features of the differential-driving mobile robot. It takes a relatively long time to localize a mobile robot with active beacon sensors since the distance to the beacon is measured by the traveling time of the ultrasonic signal. When the mobile robot is moving slowly the measurement time does not yield a high error. At a higher mobile robot speed, however, the localization error becomes too large to locate the mobile robot. Therefore, in high-speed mobile robot operations, instead of using two or more active beacons for localization, only one active beacon and the global features of the mobile robot are used to localize the mobile robot in this research. The two global features are the radius and center of the rotational motion for the differential-driving mobile robot which generally describe motion of the mobile robot and are used for the trace prediction of the mobile robot. In high speed operations the localizer finds an intersection point of this predicted trace and a circle which is centered at the beacon and has the radius of the distance between the mobile robot and the beacon. This new approach resolves the large localization error caused by the high speed of the mobile robot. The performance of the new localization algorithm has been verified through the experiments with a high-speed mobile robot.

Design of an X-band patch array antenna for an energy saving system (절전센서용 X-밴드 대역 패치 어레이 안테나 설계)

  • Chae, Gyoo-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.125-129
    • /
    • 2010
  • This paper introduces an X-band microstrip patch array antenna that can be suitable for an energy saving system. The presented patch antenna comprises with 2-element linear array. The antenna is simulated using CST MWS and manufactured using FR-4(h=1.0mm, ${\varepsilon}r=4.4$). The estimated bandwidth, gain and beamwidth are 4%(VSWR$\leq$2), 6.3dBi and about 60o in elevation and 15o in azimuth, respectively. The antenna is fabricated and optimized based on the simulation result and installed on the backside of the sensor circuit and measured. The measured bandwidth, gain and beamwidth are 7%(VSWR$\leq$2), 4.8dBi and about 55o(El)/15o(Az), respectively.

Implementation of Externally Controllable Miniaturized Capsule for the Stimulation of Intestine (체외 제어 가능한 소화관 자극용 초소형 캡슐 구현)

  • Park, J.C.;Park, H.J.;Lee, J.W.;Song, B.S.;Lee, S.H.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.176-184
    • /
    • 2003
  • In this paper, a swallowable miniaturized capsule, which applicable for electrical stimulation of digestive organ to improve the motion of intestine in research purpose, is proposed and implemented. The developed capsule can be controlled for the behavior of the power on/off, amplitude and pulse rate for the patient stimulus, by internally equipped with miniaturized RF receiver that linked by the command of external transmitter. The experimental result of the implemented miniaturized capsule in the animal intestine show the ability of effective control for the stimulus parameters.