Browse > Article
http://dx.doi.org/10.5369/JSST.2003.12.4.176

Implementation of Externally Controllable Miniaturized Capsule for the Stimulation of Intestine  

Park, J.C. (경북대학교 센서공학과)
Park, H.J. (경북대학교 전자전기컴퓨터학부)
Lee, J.W. (경북대학교 전자전기컴퓨터학부)
Song, B.S. (경북대학교 첨단감각기능회복장치연구소)
Lee, S.H. (경북대학교 전자전기컴퓨터학부)
Cho, J.H. (경북대학교 전자전기컴퓨터학부)
Publication Information
Journal of Sensor Science and Technology / v.12, no.4, 2003 , pp. 176-184 More about this Journal
Abstract
In this paper, a swallowable miniaturized capsule, which applicable for electrical stimulation of digestive organ to improve the motion of intestine in research purpose, is proposed and implemented. The developed capsule can be controlled for the behavior of the power on/off, amplitude and pulse rate for the patient stimulus, by internally equipped with miniaturized RF receiver that linked by the command of external transmitter. The experimental result of the implemented miniaturized capsule in the animal intestine show the ability of effective control for the stimulus parameters.
Keywords
swallowable miniaturized capsule; gastrointestinal tract; bi-directional telemetry; electrical stimulation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Podmarenkova L. F, Stimulant of the Gastrointestinal Tract and Mucosae(AESGTM) in Patients with Disturbances of the Large Gut Function, 1987
2 Shturkalin B, 'Instruction for the Application of Autonomous Electronic Stimulant of the Gastrointestinal Tract and Mucosae,' AESGTM: Electronic Normalizer, 1995
3 M. Appleyard, Z. Fireman, A. Glukhovsky, H. Jacob, R. Shreiver, S. Kadirkamanathan, A. Lavy, S. Lewkowicz, E. Scapa. R. Shofti, P. Swain, and A. Zaretsky, 'A randomized trial comparing wireless capsule endoscopy with push enteroscopy for the detection of smallbowel lesions,' Gastroenterology, vol. 119, no. 6, pp. 1431-1438, Dec., 2000   DOI   ScienceOn
4 H. J. Park, H. W. Nam, B. S. Song, and J. H. Cho, 'Design of Miniaturized Telemetry Module for . Bi-Directional Wireless En doscopv,' ITC-CSCC 2002 Proceedings, pp. 494-496, July, 2002
5 H. J. Park, H. W. Nam, B. S. Song, J. L. Choi, H. C. Choi, J. C. Park, M. N. Kim, J. T. Lee, J. H. Cho, 'Design of Bi-Directional And Multi-Channel Miniaturized Telemetry Module For Wireless Endoscopy,' 2nd IEEE-EMBS special topic conference on microtechnologies in medicine & biology, pp. 273-276, May, 2002
6 H. J. Park, H. W. Nam, Y. H. Yoon, Y. S. Park, B. S. Song, J. H. Cho, 'Technique for Position Detection of Miniatured Wireless Telemetry Module in the Human Body,' Proceding of the 32nd ISR, pp. 19-21. April, 2001
7 S. D'Attanasio, O. Tonet, G. Megali, M. Carrozza, and P. Dario, 'A Semi-Automatic HandHeld Mechatronic Endoscope with Collision-Avoidance Capabilities,' Proc. of International Conference on Robotic and Automation ICRA2000, 2:1586-1591, 2000
8 H. R. Choi, 'Micro Robot Actuated by Artificial Muscle Actuators Based on Dielectric Elastomer,' Proc. of 2nd China-Korea Workshop on Robotics, pp. 51-56, June, 2002
9 P. Dadvani, Report on the clinical tests of the autonomous electronic siimulent of the gastrointestinal tract and mucosae (AESGTM as applied to patients with some digestive diseases), 1998
10 Ronnie Turner, 'Electronic Sputnik Capsule Against Parasites,' Positive Health, Complementary Medicine Magazine, http://www.positivehealth. com/permit/Articles/Health/turn60.htm, 2002
11 Korkina G. Report of Clinical Tests of the Autonomous Electronic Stimulant of the Gastrointestinal Tract and Mucosae (AESGTM) in Diabetes Mellitus Patients, 1996
12 Velichkovsky B and Lurie B. Manual of the AESGTM Device, 1997
13 Seregin V, Zubare A, Chernyshev M, and Sheblanov V, The Major Link of the Mechanism of Nonspecific Effect of the AESGTM Generator on the Organism, 1996
14 Shyrkalin B, Effect of the Autonomous Electronic Stimulant of the Gastrointestinal Tracts and Mucosae (AESGTM) on functional status of Gastrointestinal Organs, 1999