• Title/Summary/Keyword: RF Signal Pattern

Search Result 49, Processing Time 0.023 seconds

Design of Radiation Pattern Reconfigurable Antenna for Vital Signal Sensing Device Attached on Wristband and SAR Analysis on Human body (팔목 부착형 생체신호 측정기기에 사용가능한 방사패턴 재구성 안테나 설계 및 인체 SAR 영향 분석)

  • Lee, Chang Min;Jung, Chang Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.666-670
    • /
    • 2015
  • This paper presents radiation pattern reconfigurable antenna for Fitbit Flex wristband which detects vital signal. Also, the paper presents Specific Absorption Rate (SAR) from the loop-dipole radiation pattern reconfigurable antenna based on the position of human body. The proposed loop-dipole radiation pattern reconfigurable antenna produces two opposite side direction radiation pattern using two RF switches. The resonant frequency of the radiation pattern reconfigurable antenna is Bluetooth communication bandwidth (2.4 - 2.485 GHz) and the maximum gain of the proposed antenna is 1.96 dBi. The proposed antenna satisfied the standard SAR value of 1.6 W/kg in 1 g tissue of the human body when the Bluetooth communication input average power of 0.04 W is excited to five parts of human body (head, chest, stomach, back, wrist). The maximum SAR value of in this simulation is presented in the part of head.

Q-band Beam-Lead Single-ended Mixer (Q-band 빔 리드 Single ended 믹서)

  • 이창훈;한석태
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.1
    • /
    • pp.26-32
    • /
    • 1994
  • In this paper, using the newly developed GaAs Schottky beam-lead diode made by Marconi company, we have developed and evaluated the waveguide type single-ended mixer at Q-band. The various components of the mixer were separately designed and optimized using the Super-Compact software. These studies included the design of the step waveguide impedance transformer and the RF-choke filter, and the optimization of a high and low impedance for the RF-choke filter. Moreover, this RF-choke filter pattern included a section to reject the second harmonic frequency of the RF signal. Finally, this Q-band mixer with 1.4GHz/400MHz IF frequency exhibits an average conversion loss of 5.3 dB over 33-50GHz bandwidth.

  • PDF

Performance Enhancement of Emergency Rescue System using Surface Correlation Technology

  • Shin, Beomju;Lee, Jung Ho;Shin, Donghyun;Yu, Changsu;Kyung, Hankyeol;Lee, Taikjin
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.3
    • /
    • pp.183-189
    • /
    • 2020
  • In emergency rescue situations, the localization accuracy of the rescue requestor is a very important factor in determining the success or failure of the rescue. Indoors where Global Navigation Satellite System (GNSS) is not operated, there is no choice but to use Wi-Fi or LTE signals. However, the performance of the current emergency rescue system utilizing those RF signals is exceedingly low. In this study, the effectiveness of the surface correlation technology using the accumulated signal pattern of RF signals was verified in relation to the emergency localization technology. To validate the proposed system, we configured and tested an emergency rescue scenario in multi-floors building. When the emergency rescue was requested, it was confirmed that the initial localization error was large owing to the short length of the accumulated signal pattern. However, the localization error decreased over time, which eventually led to the accurate location information being delivered to the rescuer.

The multipath propagation loss analysis of dynamic telemetry link using the 3D antenna pattern (3차원 안테나 패턴을 사용한 동적 원격측정링크의 다중경로 전파손실 분석)

  • Kim, Kyun-Hoi;Shin, Seok-Hyun;Koh, Kwang-Ryul;Yun, Jung-Kug
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.3
    • /
    • pp.254-260
    • /
    • 2011
  • Telemetry link is dynamic communication link that antenna gain and polarization are varying with the movement of the airplane. In this paper we calculated the antenna gain, polarization mismatch using the flight trajectory, motion of the airplane and 3D antenna pattern. And we modeled the multipath environment to the 2-Ray spherical earth reflection geometry, estimated the received signal strength when the narrow beam antenna received the RF signal transmitted from the airplane. Also we performed the flight test and after comparing measured value with the estimated value, we confirmed to almost coincide with each other.

Performance analysis of SNR and BER for radiation pattern reconfigurable antenna (인체 부착용 방사패턴 재구성 안테나의 SNR 및 BER 성능 분석)

  • Lee, Chang Min;Jung, Chang Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4125-4130
    • /
    • 2015
  • This paper presents the communication performance for the radiation pattern reconfigurable antenna in the wearable device measuring bio signal (temperature, blood pressure, pulse etc.) of human body. The operational frequency is 2.4 - 2.5 GHz, which covers Bluetooth communication bandwidth. The maximum gain of the antennas is 1.96 dBi. The proposed antenna is efficiently transmitting and receiving signal by generating two opposite beam directions using two RF switches (PIN diode). Also, we investigated how radiation pattern changes according to three angles ($30^{\circ}$, $90^{\circ}$, $150^{\circ}$) of Top Loading. In this paper, we measured and compared the SNR (Signal-to-Noise Ratio) and BER (Bit Error Rate) performances of the proposed antennas in the condition between an ideal environment of anechoic chamber and smart house existing practical electromagnetic interferences (Universal Software Radio Peripheral, USRP). Throughout the comparing the results of the measurement of two cases, we found that the SNR is degraded over 5dB in average and BER is increased over ten times in maximum, therefore, it is confirmed that the error rate of receiving signal is increased. The measured results of SNR and BER value in this paper able to expect the performance degrading by the interference from the electromagnetic devices.

λ/64-spaced compact ESPAR antenna via analog RF switches for a single RF chain MIMO system

  • Lee, Jung-Nam;Lee, Yong-Ho;Lee, Kwang-Chun;Kim, Tae Joong
    • ETRI Journal
    • /
    • v.41 no.4
    • /
    • pp.536-548
    • /
    • 2019
  • In this study, an electronically steerable parasitic array radiator (ESPAR) antenna via analog radio frequency (RF) switches for a single RF chain MIMO system is presented. The proposed antenna elements are spaced at ${\lambda}/64$, and the antenna size is miniaturized via a dielectric radome. The optimum reactance load value is calculated via the beamforming load search algorithm. A switch simplifies the design and implementation of the reactance loads and does not require additional complex antenna matching circuits. The measured impedance bandwidth of the proposed ESPAR antenna is 1,500 MHz (1.75 GHz-3.25 GHz). The proposed antenna exhibits a beam pattern that is reconfigurable at 2.48 GHz due to changes in the reactance value, and the measured peak antenna gain is 4.8 dBi. The reception performance is measured by using a $4{\times}4$ BPSK signal. The measured average SNR is 17 dB when using the proposed ESPAR antenna as a transmitter, and the average SNR is 16.7 dB when using a four-conventional monopole antenna.

A Study on the Estimation of Energy Expenditure and falls measurement system for the elderly (고령자를 위한 에너지 소비 추정 및 낙상 측정 시스템에 관한 연구)

  • Lim, Chae-Young;Jeon, Ki-Man;Ko, Kwang-Cheol;Koh, Kwang-Nak;Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.4
    • /
    • pp.1-9
    • /
    • 2012
  • As we are turnning into the aged society, accidents by falling down are increasing in the aged people's group. In this paper, we design the system with the 3-Axis acceleration sensor which is composed by a single chip. The body activity signal is measured with the signal detector and RF communicator in this proposed system and the and falling by the entering signal pattern analysis with 3-Axis acceleration sensor. For the RF communication, we are using nRF24L01p and 8bits ATmega uC for the processor. The error of energy expenditure estimation between motor driven treadmill and proposed a body activity module was 7.8% respectively. Human activities and falling is monitored according to analyze and judge the critical value of the Signal Vector. as falled down if they don't turn off the alarm after specific period and the aged person's after falling down activities are their position and more.

Performance Improvement of Offline Phase for Indoor Positioning Systems Using Asus Xtion and Smartphone Sensors

  • Yeh, Sheng-Cheng;Chiou, Yih-Shyh;Chang, Huan;Hsu, Wang-Hsin;Liu, Shiau-Huang;Tsai, Fuan
    • Journal of Communications and Networks
    • /
    • v.18 no.5
    • /
    • pp.837-845
    • /
    • 2016
  • Providing a customer with tailored location-based services (LBSs) is a fundamental problem. For location-estimation techniques with radio-based measurements, LBS applications are widely available for mobile devices (MDs), such as smartphones, enabling users to run multi-task applications. LBS information not only enables obtaining the current location of an MD but also provides real-time push-pull communication service. For indoor environments, localization technologies based on radio frequency (RF) pattern-matching approaches are accurate and commonly used. However, to survey radio information for pattern-matching approaches, a considerable amount of time and work is spent in indoor environments. Consequently, in order to reduce the system-deployment cost and computing complexity, this article proposes an indoor positioning approach, which involves using Asus Xtion to facilitate capturing RF signals during an offline site survey. The depth information obtained using Asus Xtion is utilized to estimate the locations and predict the received signal strength (RF information) at uncertain locations. The proposed approach effectively reduces not only the time and work costs but also the computing complexity involved in determining the orientation and RF during the online positioning phase by estimating the user's location by using a smartphone. The experimental results demonstrated that more than 78% of time was saved, and the number of samples acquired using the proposed method during the offline phase was twice as much as that acquired using the conventional method. For the online phase, the location estimates have error distances of less than 2.67 m. Therefore, the proposed approach is beneficial for use in various LBS applications.

Design and Performance Evaluation of M×M MIMO Transmission in ESPAR Antenna (ESPAR 안테나에서 M×M MIMO 송신방식의 설계와 성능 평가)

  • Bok, Junyeong;Lee, Seung Hwan;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.12
    • /
    • pp.1061-1068
    • /
    • 2013
  • In this paper, we propose a $M{\times}M$ beam-space multiple input multiple output (BS-MIMO) system using electronically steerable parasitic array radiator (ESPAR) antenna. Conventional MIMO method required multiple RF chains because it map the transmission signals onto multiple antennas. So, conventional MIMO system has high cost for design and high energy consumption at RF circuit. Also, It is difficult to use MIMO system in battery based mobile terminals with limited physical area. In order to solve these problems, BS-MIMO technique which map the data signal onto bases in beam space domain was proposed using ESPAR antenna with single RF chain. This paper, we design and analyze the performance of extended $M{\times}M$ BS-MIMO technique. Simulation results show that the proposed BS-MIMO system has similar BER performance compare to conventional MIMO scheme. Therefore, BS-MIMO system with single RF chain will has a low RF power consumption and low cost for RF hardware design as compared with conventional MIMO technique with multiple RF chains.

Analysis of Distances for MRI Scan to Maintain Pptimal Signal Intensity in a Surface Coil (MRI 검사 시 코일내 최적의 신호강도를 유지할 수 있는 거리의 기준 분석)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.10
    • /
    • pp.158-164
    • /
    • 2018
  • The purpose of this study is to statistically analyze the signal intensity pattern according distance from the surface coil center and to maintain optimal signal intensity under clinical circumstances where the surface coil centers are not correctly positioned due to various causes. The cylindrical fluid phantom was placed and moved from the coil center in vertical direction with 1 cm increments. The signal intensities were measured and compared. As a result, the signal intensity showed no significant difference within 4 cm and 1 cm from in T1 weighted images while in T2 weighted images the signal intensity was maintained up to 5 cm and lower 3 cm in the upper and lower direction from the coil center. In conclusion, to maintain the optimal signal intensity the target region should be located within the reference distances proposed in this study.