• Title/Summary/Keyword: RF Noise

Search Result 623, Processing Time 0.03 seconds

Highly Accelerated SSFP Imaging with Controlled Aliasing in Parallel Imaging and integrated-SSFP (CAIPI-iSSFP)

  • Martin, Thomas;Wang, Yi;Rashid, Shams;Shao, Xingfeng;Moeller, Steen;Hu, Peng;Sung, Kyunghyun;Wang, Danny JJ
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.210-222
    • /
    • 2017
  • Purpose: To develop a novel combination of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) with integrated SSFP (CAIPI-iSSFP) for accelerated SSFP imaging without banding artifacts at 3T. Materials and Methods: CAIPI-iSSFP was developed by adding a dephasing gradient to the balanced SSFP (bSSFP) pulse sequence with a gradient area that results in $2{\pi}$ dephasing across a single pixel. Extended phase graph (EPG) simulations were performed to show the signal behaviors of iSSFP, bSSFP, and RF-spoiled gradient echo (SPGR) sequences. In vivo experiments were performed for brain and abdominal imaging at 3T with simultaneous multi-slice (SMS) acceleration factors of 2, 3 and 4 with CAIPI-iSSFP and CAIPI-bSSFP. The image quality was evaluated by measuring the relative contrast-to-noise ratio (CNR) and by qualitatively assessing banding artifact removal in the brain. Results: Banding artifacts were removed using CAIPI-iSSFP compared to CAIPI-bSSFP up to an SMS factor of 4 and 3 on brain and liver imaging, respectively. The relative CNRs between gray and white matter were on average 18% lower in CAIPI-iSSFP compared to that of CAIPI-bSSFP. Conclusion: This study demonstrated that CAIPI-iSSFP provides up to a factor of four acceleration, while minimizing the banding artifacts with up to a 20% decrease in the relative CNR.

Field Probe Sensor Based on the Electro-Optic Effect (전기광학효과를 이용한 전계 프로브 센서)

  • Kyoung, Un-Hwan;Kim, Gun-Duk;Eo, Yun-Seong;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.2
    • /
    • pp.71-75
    • /
    • 2009
  • A compact electric field probe sensor incorporating two different electro-optic materials of $LiNbO_3$ and GaAs was proposed and fabricated, and it was used to measure the strength of the horizontal and vertical fields generated by a microstrip ring-resonator filter. The sensitivities of the sensors in $LiNbO_3$ and GaAs were $9.315{\mu}V/\sqrt{Hz}$ and ${\sim}49.346{\mu}V/\sqrt{Hz}$ respectively, and their signal to noise ratios were approximately ${\sim}50\;dB$ and ${\sim}40\;dB$ respectively. And the operating frequency range was up to ${\sim}1.2\;GHz$. The electric field profile for the test circuit was scanned and found to be in good agreement with that obtained by using the HFSS simulation.

Review of Magnetocardiography Technology based on SQUIDs (SQUID를 이용한 심자도 기술의 개발동향)

  • Lee, Y.H.;Kwon, H.;Kim, J.M.;Kim, K.;Yu, K.K.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.13 no.3
    • /
    • pp.139-145
    • /
    • 2012
  • Electric activity of cardiac muscles generates magnetic fields. Magnetocardiography (or MCG) technology, measuring these magnetic signals, can provide useful information for the diagnosis of heart diseases. It is already about 40 years ago that the first measurement of MCG signals was done by D. Cohen using SQUID (superconducting quantum interference device) sensor inside a magnetically shielded room. In the early period of MCG history, bulky point-contact RF-SQUID was used as the magnetic sensor. Thanks to the development of Nb-based Josephson junction technology in mid 1980s and new design of tightly-coupled DC-SQUID, low-noise SQUID sensors could be developed in late 1980s. In around 1990, several groups developed multi-channel MCG systems and started clinical study. However, it is quite recent years that the true usefulness of MCG was verified in clinical practice, for example, in the diagnosis of coronary artery disease. For the practical MCG system, technical elements of MCG system should be optimized in terms of performance, fabrication cost and operation cost. In this review, development history, technical issue, and future development direction of MCG technology are described.

Design and Fabrication of the Ka-Band Receive Module for Millimeter Wave Seeker (밀리미터파 탐색기를 위한 Ka-대역 수신기 모듈의 설계 및 제작)

  • Yang, Seong-Sik;Lim, Ju-Hyun;Song, Sung-Chan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.1
    • /
    • pp.78-84
    • /
    • 2012
  • In this paper, we introduced the design technique about a Ka band receive module for millimeter wave seekers. The receiver module consists of a waveguide, circulator and transition for antenna connection, and a limiter and gain control amplifier for receiver protection. This module is comprised of a sum, azimuth and elevation channel for receiving monopules signal, and a SLB channel for the acquisition of jamming signal. In this paper, receiver gain and range of gain control dependent on ADC nonlinear characteristic was analyzed and designed for wide dynamic range receive. In the test result of the fabricated Ka-band receive, the frequency band is 1 GHz, the noise figure is as low as 8.2 dB, the gain is $56{\pm}2dB$, the dynamic range is 135 dB, the gain congtrol is more than 86 dB, the channel isolation is more than 35 dB.

A Study on Link Analysis of Telemetry Rocket-borne Antenna (텔레메트리 로켓 탑재 안테나의 회선 분석에 관한 연구)

  • 김성완;황수설;이재득
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.3
    • /
    • pp.311-318
    • /
    • 2004
  • It is required to design the RF link with sufficiently stable signal margin to minimize bit errors and improve the quality of received data in the telemetry system modulated digitally like PCM/FM. In case of the vehicle flying at a high speed, the variation of the gain pattern between transmitting and receiving antenna and the fee space loss due to flight distance cause the fluctuation of link. In this paper, KSR(Korea Sounding Rocket)- III, the first domestic liquid rocket which was successfully launched in Nov. 2002 is introduced. The SNR(signal-to-noise ratio) variation of the telemetry signal which was measured at S-band ground station, the one which was simulated considering the flight trajectory, and the attitude variation such as roll, pitch and yaw are compared, analyzed, and agree very well. In addition, two virtual flying situations are simulated and evaluated-only one antenna is equipped in one case, and rocket is roll-free in the other.

Development and Applications of a Wireless Bioelectric Signal Measurement System on the Electrodes (전극 상의 일체형 무선 생체전기신호 측정 시스템 개발 및 응용)

  • Joo, Se-Gyeong;Kim, Hee-Chan
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.88-94
    • /
    • 2003
  • Electromyogram (EMG) is the bioelectric signal induced by motor nerves. Analyzing EMG with the movement produced by muscle contraction, we can provide input commands to a computer as a man-machine interface as well as can evaluate the patient's motional abnormality. In this paper, we developed an integrated miniaturized device which acquires and transmits the surface EMG of an interested muscle. Developed system measures $60{\times}40{\times}25mm$, weighs 100g. Using an amplifier circuitry on the electrodes and the radio frequency transmission, the developed system dispenses with the use of cables among the electrodes, amplifier, and the post processing system (personal computer). The wiring used in conventional systems can be obstacle for natural motion and source of motion artifacts. In results, the developed system improves not only the signal-to-noise ration in dynamic EMG measurement, but also the user convenience. We propose a new human-computer interface as well as a dynamic EMG measurement system as a possible application of the developed system.

Capacity esitmation of microcell in macro/microcell overlaid W-CDMA WLL system (매크로셀과 마이크로셀이 중첩된 W-CDMA 무선가입자망에서 마이크로셀의 용량 산정)

  • 손성찬;노재성;김수용;조성준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.9A
    • /
    • pp.2153-2164
    • /
    • 1998
  • This paper has presented the parameters for the coexistence between two systems in macro/microcell ovelaid W-CDMA WLL (wideband CDMA wireless local loop) and has calculated the capacity of forward/reverse link in microcell. To produce the capacity for analyzing system interference effects, we have shown tables and graphs with the parameters sucyh as RF channel bandwidth of WLL(W), the transmission rate of service message(R), the required signal power to noise power ratio( $E_{b/}$ $N_{0}$) for achieving accepatable error rate, te user number ( $N_{W1}$, $N_{W2}$) of the neighboring system, the signal power to interference power ratio(.GAMMA.$_{C1B}$, .GAMMA.$_{C2B}$) of the neighboring system, the normalized distance(d) between microcell and macrocell base-station, and microcell to macrocell radius ratio ( $R_{d}$). From the results, we have convinced that the capacity of microcell diminishes as increasing the user number ( $N_{W2}$) in macrocell, increasing the microcell radius, and decreasing the normalized distance(d) between microcell and macrocell base-station. Especially, we have known that when $R_{d}$=0.1, $N_{W2}$ must be below 24 at .GAMMA.$_{C2B}$ = 0 dB and below 8 at .GAMMA.$_{C2B}$ = 4 dB for the acceptable capacity raito to be over 80%. Therfore, this paper is usefult to design microcell W-CDMA WLL for accommodating more user number under the interference effects of macrocell W-CDMA WLL and is expected to be reference in power control if base-station.ation.ion.ation.ation.

  • PDF

Design of Temperature Compensation Circuit for W-band Radar Receiver (W-band 레이더 수신기용 온도보상회로 설계)

  • Lee, Dongju;Kim, Wansik;Kwon, Jun-Beom;Seo, Mihui;Kim, Sosu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.4
    • /
    • pp.129-133
    • /
    • 2020
  • In this paper, a temperature compensation circuit is presented in order to mitigate gain variability due to temperature in the W-band low-noise amplifier (LNA). The proposed cascode temperature compensation bias circuit automatically controls gate bias voltages of the common-source LNA in order to suppress variations of small-signal gain. The designed circuit was realized in a 100-nm GaAs pHEMT process. The simulated voltage gain of W-band LNA including the proposed bias circuit is >20 dB with gain variability less than ±0.8 dB in the range of temperatures between -35 to 71℃. We expect that the proposed circuit contributes to millimeter-wave receivers for stable performances in radar applications.

Design and Fabrication of X-Band GaN TRM for a Radar (레이더용 X대역 GaN 반도체 송수신기 설계 및 제작)

  • Lim, Jae-Hwan;Jin, Hyung-Suk;Ryu, Seong-Hyun;Park, Jong-Sun;Kim, Tae-Hun;Lim, Duck-Hee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.172-182
    • /
    • 2014
  • In this paper, is is presented the result of design and fabrication for X band T/R module using in active array radar. The high power RF circuit was fabricated using GaN element, so that high power and high efficiency was fulfilled comparing with the previous T/R module that have under 50 W output power for X band. Designed X band T/R module demonstrated 200 W(53 dBm) peak power, 20 us pulse width with 0.4 dB pulse droop and 20 % duty cycle. And it has characteristics of 26 dB receive gain and 4.5 dB noise figure. The structure was applied to prevent serious damage of receive path and GaN HPA by transmitting power during trasmit time of a pulse radar.

A Study for the Characteristics of multi-layer VOx Thin Films for Applying to IR Absorbing Layer (적외선 흡수층 응용을 위한 다층 산화 바나듐 박막의 특성에 관한 연구)

  • 박철우;문성욱;오명환;정홍배
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.859-864
    • /
    • 2000
  • Recently IR detecting devices using MEMS have been actively studied. Microbolometer, one of these devices, detects the change of resistivity as the change of temperature of the device by absorbing IR, IR absorbing materials for microbolometer should have high TCR value and low noise characteristics which depends on resistivity. We fabricated multi-layer VOx thin films to improve the IR detectivity of uncooled IR devices and analyzed IR absorbing characteristics. We fabricated multi-layer VOx thin films by RF reactive sputtering method on SiNx substrate and changed characteristics using the different thickness of V and V$_2$O$\_$5/ thin films. Then we annealed them under 300$\^{C}$. The TCR (Temperature Coefficient of Resistance) measurement was carried out to estimate the IR detectivity of multi-layer VOx thin films. XRD (X-Ray Diffraction) analysis was carried out to estimate the IR detectivity of multi-layer VOx thin films. ZXRD (X-Ray Diffraction) analysis was used to find out phases and structures of V and V$_2$O$\_$5/ thin films. AES (Auger Electron Spectroscopy) analysis was used to find out composition of multi-layer VOx thin films before and after annealing. We obtained the optimum thickness range of V and V$_2$O$\_$5/ thin films from the result of AES analysis. We changed the thickness of V$_2$O$\_$5/ about 20 to 150 $\AA$ and thickness of V about 10 to 20 $\AA$. As the result of this, TCR value of multi-layer VOx thin films was about -2%/k and the resistivity was ∼1Ωcm.

  • PDF