• Title/Summary/Keyword: RF Detector

Search Result 121, Processing Time 0.025 seconds

Research on PAE and Linearity of Power Amplifier Using Adaptive Bias and PBG Structure (적응형 바이어스와 PBG를 이용한 전력증폭기 전력효율과 선형성 개선에 관한 연구)

  • Cho Sunghee;Seo Chulhun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.2 s.332
    • /
    • pp.87-92
    • /
    • 2005
  • In this paper, adaptive bias circuit and PBG structure have been employed to suppress IMD and improve PAE (Power Added Efficiency) of the power amplifier. It is controlling the gate 'dc' bias voltage with the envelope of the input RF signal. and The PBG structure has been employed on the output port of power amplifier . The proposed power amplifier using adaptive bias circuit and PBG has been improved the IMG by 3 dBc, and the average PAE by $35.54\%$, respectively.

RF Impedance Matching Algorithm Using Phase Detector (임피던스 정합장치 내 위상센서를 이용한 RF정합 알고리즘 연구)

  • Kim, Hwanggyu;Yang, Jinwoo;Kang, Sukho;Choi, Daeho;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.2
    • /
    • pp.32-37
    • /
    • 2022
  • As semiconductors become finer, equipment must perform precise and accurate processes to achieve the desired wafer fabrication requirement. Radio frequency power delivery system in plasma system plays a critical role to generate the plasma, and the role of impedance matching unit is critical to terminate the reflected radio frequency power by modifying the impedance of the matching network in the plasma equipment. Impedance matching unit contains one fixed inductor and two variable vacuum capacitors whose positions are controlled two step motors. Controlling the amount of vacuum variable capacitor should be made as soon as possible when the mismatched impedance is detected. In this paper, we present the impedance matching algorithm using the phase sensor.

A Biomolecular Sensing Platform Using RF Active System

  • Kim, Sang-Gyu;Lee, Hee-Jo;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.4
    • /
    • pp.227-233
    • /
    • 2012
  • This paper describes a novel and compact biosensing platform using an RF active system. The proposed sensing system is based on the oscillation frequency deviation due to the biomolecular binding mechanism on a resonator. The impedance variation of the resonator, which is caused by a specific biomolecular interaction results in a corresponding change in the oscillation frequency of the oscillator so that this change is used for the discrimination of the biomolecular binding, along with concentration variation. Also, a Surface Acoustic Wave (SAW) filter is utilized in order to enhance the biosensing performance of our system. Because the oscillator operates at the skirt frequency range of the SAW filter, a small amount of oscillation frequency deviation is transformed into a large variation in the output amplitude. Next, a power detector is used to detect the amplitude variation and convert it to DC voltage. It was also found that the frequency response of the biosensing system changes linearly with three streptavidin concentrations. Therefore, we expect that the proposed RF biosensing system can be applied to bio/medical applications capable of detecting a nano-sized biomolecular interaction.

Ringer's solution detector and transceiver design for efficient manage of patient (효율적인 환자관리를 위한 링거액 감지기 및 송수신기 설계)

  • Song, Je-Ho;Lee, In-Sang;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.45-50
    • /
    • 2016
  • This paper reports a Ringer's solution detector and transceiver design for the efficient management of patients. The ringer's solution detection and transceiver consisted of the main control part, ringer's solution detection part, display and warning light part, wireless transceiver, and power supply part. The light receiving part of the ringer's solution detection part employed TSL260R-LF photodiode; light permeating part, Water-Clear type LED; and wireless transceiver part, the RF wireless data transceiver module, NR-FPCX. As a result of this Ringer's solution detector and transceiver design that can manage the patient efficiently, it was found that when the ringer's solution was detected by the double photodiode, the operating frequency was 11.95kHz; when it was not detected, the number was 9.6kHz. In the ringer's solution receiver, when the ringer's solution was detected, the number was 0. The corresponding unique RF code was displayed when not detected. The power used in the ringer's solution detection part was converted to the Sleep mode to operate under battery save mode. The ringer's solution transceiver can exchange wireless communication approximately within a 700m radius.

A Study on Apparatus of Human Body Antenna for Mine Detection (지뢰탐지용 휴먼바디 안테나 장치 연구)

  • Kim, Chi-Wook;Koo, Kyong-Wan;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.269-272
    • /
    • 2015
  • this is the study of the human body antenna device which can detect the powder in a 360-degree on(under) the ground whether it is metal or nonmetal using superhigh frequency RF beam equipped with the body. and it is able to transmit the data of the detection of the powder, battle combats can share that among them. with its flexible roof radial antenna structure, it emits the superhigh frequency RF beam to the front and flank multiply, preprocesses through the powder preprocessing part. and with the non-linear regression model algorism engine part, reflecting the attenuation characteristics depend on the delayed time of degree of the signal power which is received to the superhigh frequency RF beam. so it is able to detect the signal of the most likely mine or powder based on the degree of the answer signal power according to the delayed time of the superhigh frequency RF beam. also, it can detect the powder whether it is metal or nonmetal, mine, dud, VBIED. it can increase the chance of detection about 90% more than existing mine detector.

A Low Power Single-End IR-UWB CMOS Receiver for 3~5 GHz Band Application (3~5 GHz 광대역 저전력 Single-Ended IR-UWB CMOS 수신기)

  • Ha, Min-Cheol;Park, Byung-Jun;Park, Young-Jin;Eo, Yun-Seong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.7
    • /
    • pp.657-663
    • /
    • 2009
  • A fully integrated single ended IR-UWB receiver is implemented using 0.18 ${\mu}m$ CMOS technology. The UWB receiver adopts the non-coherent architecture, which simplifies the RF architecture and reduces power consumption. The receiver consists of single-ended 2-stage LNAs, S2D, envelope detector, VGA, and comparator. The measured results show that sensitivity is -80.8 dBm at 1 Mbps and BER of $10^{-3}$. The receiver uses no external balun and the chip size is only $1.8{\times}0.9$ mm. The consumed current is very low with 13 mA at 1.8 V supply and the energy per bit performance is 23.4 nJ/bit.

Design of a 960MHz CMOS PLL Frequency Synthesizer with Quadrature LC VCO (960MHz Quadrature LC VCO를 이용한 CMOS PLL 주파수 합성기 설계)

  • Kim, Shin-Woong;Kim, Young-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.7
    • /
    • pp.61-67
    • /
    • 2009
  • This paper reports an Integer-N phase locked loop (PLL) frequency synthesizer which was implemented in a 250nm standard digital CMOS process for a UHF RFID wireless communication system. The main blocks of PLL have been designed including voltage controlled oscillator, phase frequency detector, and charge pump. The LC VCO has been used for a better noise property and low-power design. The source and drain juntions of PMOS transistors are used as the varactor diodes. The ADF4111 of Analog Device has been used for the external pre-scaler and N-divider to divide VCO frequency and a third order RC filter is designed for the loop filter. The measured results show that the RF output power is -13dBm with 50$\Omega$ load, the phase noise is -91.33dBc/Hz at 100KHz offset frequency, and the maximum lock-in time is less than 600us from 930MHz to 970MHz.

H-Band(220~325 GHz) Transmitter and Receiver for an 1.485 Gbit/s Video Signal Transmission (H-대역(220~325 GHz) 주파수를 이용한 1.485 Gbps 비디오 신호 전송 송수신기)

  • Chung, Tae-Jin;Lee, Won-Hui
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.345-353
    • /
    • 2011
  • An 1.485 Gbit/s video signal transmission system using the carrier frequency of H-band(220~325 GHz) was implemented and demonstrated for the first in domestic. The RF front-end was composed of Schottky barrier diode sub-harmonic mixers(SHM) and frequency triplers, and diagonal horn antennas for transmitter and receiver, respectively. The transmitted carrier frequency of 246 GHz was implemented in the H-band, and LO frequencies of H-band SHM is 120 GHz and 126 GHz for transmit and receive chains, respectively. The modulation scheme is ASK(Amplitude Shift Keying) where IF frequency is 5.94 GHz and the envelop detection was used in heterodyne receiver architecture, and direct detection receiver using ZBD(Zero Bias Detector) was implemented as well. The 1.485 Gbit/s video signal with HD-SDI format was successfully transmitted over wireless link distance of 5 m and displayed on HDTV at the transmitted average output power of 20 ${\mu}W$.

A Design and Implementation of a Prototype Microwave Power Transmission System (마이크로파 전력전송시스템의 프로토타입 설계 및 구현)

  • Park, Min-Woo;Park, Jin-Woo;Back, Seung-Jin;Koo, Ja-Kyung;Lim, Jong-Sik;Ahn, Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2227-2235
    • /
    • 2009
  • This paper describes the system configuration and measured performances of a wireless power transmission system which utilizes microwave. The technically final target of this system is to provide DC power to various mobile terminals within limited spaces such as buildings, conference rooms, and so on. The prototype system is built using in-house designed and fabricated circuits such as microwave oscillator, high power amplifier, microstrip patch antenna, low pass filter, and detector/rectifier. The fixed RF power of 29.3dBm at 2.4GHz is produced from the high power amplifier and transmitted through the transmitting antenna, while the received RF power at the receiving antenna is transformed into DC power through the detector/rectifier. The measured change of DC voltage according to the distance between transmitting and receiving antenna is described.

Implementation of apparatus for detecting Ringer's solution exhaustion using electrostatic capacitance variation (정전용량변화를 이용한 링거액소진감지장치의 구현)

  • Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Electrostatic capacitance measurement method in a fine hose was proposed, in which two ring-type electrodes were disposed on the hose in the direction of fluid flow instead of the conventional face-to-face electrodes. With the proposed electrode structure, we realized a Ringer's solution exhaustion detector for an IV(invasive vein) injection set. On a 4 mm-diameter hose of IV set, we disposed two ring-type electrodes of 10 mm width at a distance of 5 mm each other and obtained 0.72 pF and 2.51 pF for air and 10 % dextrose Ringer's solution in the hose, respectively. The capacitance between the two electrodes varied with the hose-wraparound coverage of electrode as well as the width of electrode and the distance between the electrodes. For hose-wraparound electrode coverage of 75 %, the capacitance varied from 0.62 pF to 1.98 pF with the Ringer's solution level between the two electrodes. A charge amplifier converted the capacitance. variation into electric signal and a comparator was used to detect whether Ringer's solution was exhausted or not. The result was delivered to a host using a RF transmitter with 320 MHz carrier frequency.