• Title/Summary/Keyword: RELATIVE HUMIDITY

Search Result 2,542, Processing Time 0.028 seconds

Effects of Curing Temperature on Autogenous Shrinkage, Relative Humidity, Pore Structure of Cement Pastes

  • Park Ki-Bong
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.853-856
    • /
    • 2005
  • A low water/cement ratio leads to autogenous shrinkage of cement paste at an early age. This autogenous shrinkage is related to the change of relative humidity in the pore structure that is formed during the hydration process. The relationship between autogenous shrinkage and relative humidity change are relatively well defined today, but the effects of temperature on autogenous shrinkage, relative humidity, and pore structures have been studied less systematically. This study focused on correlating alterations of these properties of cement paste hydrated at constant temperatures of 20, 40, and $60^{\circ}C$. The test results clearly indicate that increasing curing temperature resulted in increased porosity, particularly for pores between 5 to 50 nm as measured by MIP, and increased autogenous shrinkages, as a consequence of a reduction of relative humidity at early ages.

Effect of relative humidity in swine house on pathogenesis of swine pleuropneumonia (돈사의 상대습도가 돼지흉막폐렴의 병인에 미치는 영향)

  • Jeong, Hyun-kyu;Han, Jeong-hee;Kim, Jae-hoon
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.1
    • /
    • pp.131-142
    • /
    • 1996
  • The effect of relative humidity in swine house on swin pleuropneumonia was examined in piglets experimentally infected with Actinobacillus pleuropneumoniae serotype 5. A total of 20 piglet were grown under 30~40%, 41~50%, 51~64% and 65~80% relative humidity chambers after intratracheal inoculation of A pleuropneumoniae. Characteristic fibrinous pleuropneumonia was observed in the pigs grown at the low relative humidity groups. The detailed results were as follows : 1. Growth performance and environment conditions were lower than high relative humidity groups. 2. Characteristic histopathological findings were fibrinous pleuritis and pneumonia accompanied congestion, hemorrhage, thrombosis and edematous change. 3. Antigenic distribution of inoculated bacterium was found mainly in alveolar macrophages or accumulated foci of macrophages adjacent to necrotic area. 4. Characteristic electron microscopic findings were proliferation of type II pneumocyte with increased lamella bodies and activated alveolar macrophages with pseudopods and widening of interstitium.

  • PDF

Effects of Relative Humidity on the Evaporator Pressure Drop (증발기의 압력강하에 대한 상대습도의 영향)

  • 김창덕;강신형;박일환;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.397-407
    • /
    • 2004
  • It is well known that some key parameters, such as evaporating temperature, refrigerant mass flow rate, face velocity and inlet air temperature, have significant influence on the evaporator performance. However performance studies related to a humid environment have been very scarce. It is demonstrated that the refrigerant mass flow rate, heat flux, water condensing rate and air outlet temperature of the evaporator significantly increase with air inlet relative humidity. As the air inlet relative humidity increases, the latent and total heat transfer rates increase, but the sensible heat transfer rate decreases. The purpose of this study is to provide experimental data on the effect of air inlet relative humidity on the air and refrigerant side pressure drop characteristics for a slit fin-tube heat exchanger. Experiments were carried out under the conditions of inlet refrigerant saturation temperature of 7 $^{\circ}C$ and mass flux varied from 150 to 250 kg/$m^2$s. The condition of air was dry bulb temperature of 27$^{\circ}C$, air Velocity Varied from 0.38 to 1.6 m/s. Experiments Showed that air Velocity decreased 8.7% on 50% of relative humidity 40% of that at degree of superheat of 5$^{\circ}C$, which resulted that pressure drop of air and refrigerant was decreased 20.8 and 8.3% for 50% of relative humidity as compared to 40%, respectively.

Development of Fuzzy Controller for Air Conditioning of Grain Bin (곡물빈용 공기조화장치의 퍼지제어기 개발)

  • 최영수;문대식;정종훈
    • Food Science and Preservation
    • /
    • v.9 no.2
    • /
    • pp.137-143
    • /
    • 2002
  • Temperature and humidity are the most important factors and should be effectively controlled for the cold storage of graius. Fuzzy logic can be easily implemented to the MIMO(Multi-Input Multi-Output) control systems. For the cold storage in grain bin, fuzzy logic was applied to an air conditioning system. The capacities of the grain bin and the air conditioner are 80 tons and 30㎾, respectively. Also, the target values of temperature and relative humidity in outlet duct of the air conditioner were 8$\^{C}$ and 75%, respectively. In order to control temperature and relative humidity of air, a damper in inlet duct was manipulated for temperature control and a heater was used for humidity control. Temperature deviation and change of temperature deviation were used as input parameters for the fuzzy system. Humidity was only considered as a load. The experimental results showed that the controlled temperature of exhausted air was maintained at 8$\pm$2$\^{C}$. Relative humidity of the air was also controlled at the target relative humidity of 50∼80%.

Investigation of Internal Temperature and Relative Humidity of Concrete Immediately After Mix and Placement (양생직후 초기재령의 콘크리트 내부 온도와 상대습도의 측정 및 분석)

  • Park, Cheol-Woo;Park, Young-Hoon;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1065-1068
    • /
    • 2008
  • Concrete is still one most common construction materials even in railway structures. As structures become massive and mega-sized, the importance of early age concrete quality control becomes more significant. Among various factors, relative humidity and temperature are the primary factors governing the early age quality. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF

Studies on the cigarette hardness(II) The Influence of relative humidity, temperature and net weight on cigarette hardness (담배 경도에 관한 연구(II) 상대습도, 온도 및 진충량이 담배의 경도에 미치는 영향)

  • 정한주;민영근;김병구;김기환
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.13 no.1
    • /
    • pp.13-18
    • /
    • 1991
  • This experiment carried out to review influence of relative humidity, temperature and net weight on cigarette hardness for the uniformal control of cigarette quality. Obtained results are as follows: 1. The difference in the cigarette physical properties of constant hardness control is considerably lower than that of constant net weight control. 2. Contribution rate for cigarette hardness is relative humidity > net weight > temperature. 3. The multiple regression equation of cigarette hardness related with relative humidity, temperature and net weight is calculated as follows.

  • PDF

Effects of Relative humidity Conditions on the Compressive Strength Changes of Corrugating Mediums (상대습도조건에 따른 골심지의 압축강도 변화에 관한 연구)

  • 이준호;김수일;하영선
    • Food Science and Preservation
    • /
    • v.7 no.1
    • /
    • pp.63-67
    • /
    • 2000
  • Changes in the compressive strength of four typical corrugating mediums (K$_2$A, AS and S) as affected by relative humidity conditions were compared and their relative cost effectiveness was analysed. All mediums lost their compressive strength as relative humidity increased. at the relative humidity of 93% , As medium lost 58% of its initial strength while S medium did about 40%. Calculations of compress factor and compress factor by price indicated that $K_2$ medium was the most cost effective and maintained the highest compressive strength among the mediums tested. It was recommended that $K_2$ medium could be effectively used to make corrugated fiberboard especially for fresh agricultural product packaging .

  • PDF

Tribological Behavior of DLC Coatings at Various Humidities (습도에 따른 DLC 코팅의 마찰 거동)

  • Jo, Gyeong-Man;An, Hyo-Seok;Kim, Dae-Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.9
    • /
    • pp.1842-1848
    • /
    • 2002
  • Although DLC coatings have good tribological properties, these are dependant on the deposition method, the property of contact surface, and test condition. Humidity, which has little influence on tribological behavior in macro scale, is an important factor of tribological behavior in small devices like MEMS. The objective of this study is to investigate the tribological behavior of DLC coatings with particular attention to their wettability at various humidities. DLC coatings were deposited on Si substrates and tested using a reciprocating friction tester against Si$_3$N$_4$balls at various humidities. The results showed that the tribological behavior of DLC coatings was dependant on relative humidity and wettablility of DLC coatings. Friction coefficient at high relative humidity was higher thar that at low relative humidity. The tungsten-containing DLC coatings had a good wear resistance at low relative humidity whereas DLC coatings derived from argon(Ar)+cesium(Cs) gases showed a good wear resistance at high relative humidity.

The Effects of Micro-Environmental Factors on the House Dust Mite

  • Jo, Wan-Je;Sohn, Jang Yeul
    • Architectural research
    • /
    • v.9 no.2
    • /
    • pp.37-45
    • /
    • 2007
  • The proliferation of the House Dust Mite(HDM) is affected by temperature, humidity, ventilation, etc. Measuring temperature and humidity was performed at the very location where dust samplings take place and where they live in reality together with temperature and humidity of the ambient of the room. There has been discussion over the key environment factor of HDM survival; absolute humidity or relative humidity. It seems that relative humidity is the more important determinant for the mite's survival through the analysis of previous studies. Temperature, humidity, ventilation rate and Der P1 were measured in 4 flats in London. Mite allergen was detected in every house. Levels of Der P1 varied between <100ng/g and 22,778ng/g. Flats with high relative humidity(>50%) and poor ventilation(<0.5ach) showed higher levels of mite allergen than flats with lower humidity and adequate air change rate. Questionnaire survey was conducted and the result helped to confirm the findings from monitoring of environmental factors and the dust sampling.

Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Low-Priced Generic Ceramic Panel Materials for Humidity Control - Focuses on analyzed measurements of temperature and humidity obtained from the housing units - (저가보급형 습도조절용 세라믹패널의 조습성능 평가 - 리빙랩 온·습도 모니터링 분석을 통한 실측결과를 중심으로 -)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.39-40
    • /
    • 2017
  • This study aims to evaluate the humidity control performance of low-priced generic ceramic panels that are used to control humidity. Temperature and humidity are monitored by using 'Living Lab' and the change of indoor relative humidity is measured and analyzed. According to the results of the study, the indoor relative humidity of rooms installed with ceramic panels was found to be low compared to that of living rooms by 2.2%RH (test period) and 3.2%RH (daily). In the case of maximum relative humidity, rooms installed with ceramic panels were found to be low by 6.9%RH. The results are attributable to the humidity absorption of ceramic panels. Accordingly, future ceramic panels need the improvement of performance and an appropriate construction area should be derived depending on indoor space.

  • PDF