• Title/Summary/Keyword: RE-connection

Search Result 206, Processing Time 0.024 seconds

Effect of cleansing methods on the bone resorption due to repeated dis/re-connection of implant abutment (지대주 풀림과 조임시 지대주 세척방법에 따른 임플란트 주변 골소실의 양에 대한 평가)

  • Yang, Seung-Min;Shin, Seung-Yun;Kye, Seung-Beom
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.535-542
    • /
    • 2007
  • Background : Repeated dis/re-connection of implant abutment caused bone loss around implant fixtures due to the new formation of biologic width of the mucosal-implant barrier. The aim of this clinical study was to evaluate whether the repeated dis/re-connection of implant abutment cause bone loss clinically and the effect of cleansing methods on a bone loss during the early healing period. Methods : A total 50 implants were installed in 20 patients and repeated dis/re-connection of abutment was performed at the time of surgery and once per week for 12 weeks. 0.9% normal saline solution as group1 and 0.1% chlorhexidine solution as group 2 was used to clean abutments. All patients had radiographs taken at the placement of implant and 4, 8, and 12 weeks postoperatively. The data for bone loss around implant were analyzed. Results: The marginal bone loss at 12 weeks were $1.28{\pm}0.51mm$, $1,32{\pm}0,57mm$ in the mesial and distal sides in group1, $1.94{\pm}0.75mm$, $1.81{\pm}0.84mm$ in group 2, respectively. In view of marginal bone loss, there was not a significant statistical difference between groups. Conclusions : Repeated dis/re-connection of implant abutment may not cause marginal bone loss around implant fixture although limited samples and short-term observation period. In spite of more bone loss in group 2, there was no statistical significant difference between groups. In context of those results, the clinical significance of the repeated dis/re-connection of implant abutment and the cleansing method of abutments is debatable when it comes to marginal bone loss during early healing period.

A Study on Benefit/Cost Analysis of Re-Bar Connection Methods for Hyper Strength(SD500) Reinforcement (SD500철근 커플러 이음의 편익/비용분석에 관한 연구)

  • Kim, Jae-Yeob;Kwon, Yeo-Wool;Kim, Jun-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.2
    • /
    • pp.81-87
    • /
    • 2008
  • High-rise building is taking a place as one of building types from apartment housings to commercial buildings. With taking in account of stability and durability, strength of used materials is increasing gradually in these high-rise buildings. According to this, frequency in use of SD500 re-bar is increasing gradually in high-rise buildings. However the study of SD500 re-bar is insufficient because SD500 re-bar started to be used for domestic buildings lately. Specially because there is no guide or study to refer to, people get into difficulties when to decide the method of re-bar connection in construction using SD500 re-bar. Accordingly in this study, it suggests the method of estimating the economical efficiency on SD500 re-bar connection, and conducts benefit/ cost analysis on lapped splice and coupler splice by applying AHP theory, and then presents its result. After to analyze re-bar diameter of D25, 29, and 32, finally we attained the result that the coupler splice is advantageous in all parts of benefit/ cost more than the lapped splice.

Experimental study of Hydraulic Cable Connection Systems with Re-tensioning and Wireless Monitoring (재긴장과 무선 모니터링이 가능한 유압식 케이블 접합부시스템의 실험에 대한 연구)

  • Kim, Min-Su;Lee, Ki-Hak;Kim, Seong-Beom;Lee, Sung-Min;Baek, Ki-Youl
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.2
    • /
    • pp.71-79
    • /
    • 2011
  • Due to the self-equilibrium status of the cable system, the loss of the tensioning in the cable system results in other cables carrying larger tension forces than those initially calculated by structural engineers. Also, turn-buckle systems, which have been widely used to pre-tension and/or re-tension the cables, are limited to use for small cables and to provide a rough estimation for tension forces. In this study, the re-tensioning cable connection systems were developed to overcome the problems mentioned above. The main objective of the proposed system is to re-tension large cables and measure the exact amount of tension forces of the cable systems. This connection system is also combined with the wireless signal monitoring module so that engineers are able to measure the tension forces any place where the internet is available. This paper presents the development of the re-tensioning cable connection systems and experiment using the real-scale cable systems to verify the fe-tensioning and signal monitoring systems.

Dynamic resource reservation scheme for connection rerouting on ATM-based PCN (ATM-based PCN에서의 연결재라우팅을 위한 유선망자원 예약방안)

  • 장경훈;심재정;김덕진;강경훈
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.2
    • /
    • pp.11-20
    • /
    • 1997
  • It is a recent trend that mobile communications and PCS are intergrated into the broadband network. Broadband mutlimedia traffic will be transported over the integrated network. In this paper, we propose a connection re-routing method for fast inter-switch hadoffs and dynamic resurce reservation scheme, which is based on the proposed re-routing method, for the ATM-based personal communications network. To reduce the delay for re-routing method, for the ATM-based personal communications network. To reduce the delay for re-routing, the proposed re-routing method is to reserve VPI/VCIs for possible inter-swich handoff calls in advance. Our reservation scheme is to statistically reserve the fixed resources for possible inter-switch handoff calls, according to the QoS of the handoff calls. The simmulation reslts show that our proposed scheme satisfies the required QoS of handoff calls and keep the dropping probability of handoff calls lower than other schemes.

  • PDF

A study on the geometry of 2-dimensional re-manifold $X_2$

  • Hwang, In-Ho
    • Journal of the Korean Mathematical Society
    • /
    • v.32 no.2
    • /
    • pp.301-309
    • /
    • 1995
  • Manifolds with recurrent connections have been studied by many authors, such as Chung, Datta, E.M.Patterson, M.Prvanovitch, Singal, and TAkano, etc (refer to [2] and [3]). Examples of such manifolds are those of recurrent curvature, Ricci-recurrent manifolds, and birecurrent manifolds.

  • PDF

Cyclic Behavior of Wall-Slab Joints with Lap Splices of Coldly Straightened Re-bars and with Mechanical Splices (굽힌 후 편 철근의 겹침 이음 및 기계적 이음을 갖는 벽-슬래브 접합부의 반복하중에 대한 거동)

  • Chun, Sung-Chul;Lee, Jin-Gon;Ha, Tae-Hun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.275-283
    • /
    • 2012
  • Steel Plate for Rebar Connection was recently developed to splice rebars in delayed slab-wall joints in high-rise building, slurry wall-slab joints, temporary openings, etc. It consists of several couplers and a thin steel plate with shear key. Cyclic loading tests on slab-wall joints were conducted to verify structural behavior of the joints having Steel Plate for Rebar Connection. For comparison, joints with Rebend Connection and without splices were also tested. The joints with Steel Plate for Rebar Connection showed typical flexural behavior in the sequence of tension re-bar yielding, sufficient flexural deformation, crushing of compression concrete, and compression rebar buckling. However, the joints with Rebend Connection had more bond cracks in slabs faces and spalling in side cover-concrete, even though elastic behavior of the joints was similar to that of the joints with Steel Plate for Re-bar Connection. Consequently, the joints with Rebend Connection had less strengths and deformation capacities than the joints with Steel Plate for Re-bar Connection. In addition, stiffness of the joints with Rebend Connection degraded more rapidly than the other joints as cyclic loads were applied. This may be caused by low elastic modulus of re-straightened rebars and restraightening of kinked bar. For two types of diameters (13mm and 16mm) and two types of grades (SD300 and SD400) of rebars, the joints with Steel Plate for Rebar Connection had higher strength than nominal strength calculated from actual material properties. On the contrary, strengths of the joints with Rebend Connection decreased as bar diameter increased and as grade becames higher. Therefore, Rebend Connection should be used with caution in design and construction.

Web Service Connection Management Scheme for Seamless Migration of User Workspace in Cloud Computing (클라우드 컴퓨팅에서 사용자 작업환경의 끊김 없는 연계를 위한 웹 서비스 연결 관리 기법)

  • Choi, Min
    • Journal of Information Technology Services
    • /
    • v.8 no.1
    • /
    • pp.193-202
    • /
    • 2009
  • Cloud computing emerges as a new computing paradigm which targets reliable and customizable services. The term builds on decades of research in virtual machine, distributed and parallel computing, utility computing, and more recently networking, web service, and software as a service. In this paper, we provide a seamless connection migration of web services. This is useful for cloud computing environment in which many client terminals have mobility. With the wireless internet facility, those mobile users can move place to place during internet communication. Therefore, we provide solutions to the two major problems in current virtualization based migration: communication failure problems and connection re-establishment. Communication channel flushing by zero window notification helps to resolve the communication failure problems and TCP port inheritance prevents connection re-establishment errors during socket reconstruction. Thus, our web service migration facility is now able to preserve open network connections, and even for server sockets. This is a highly transparent approach, in that we did not Introduce additional messages for channel flushing and did not make any modification to the TCP protocol stack. Experimental results show that the overhead due to connection migration of web services is almost negligible when compared with time to take the conventional web service migration.

Signaling for Inter-Switching Handoff on ATM-based Wired/Wireless Integraed Network (ATM기반 유무선 통합망에서 교환기간 핸드오프 처리를 위한 시그널링 방안)

  • 장경훈;강경훈;박상현;안영화;김덕진
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.1
    • /
    • pp.39-51
    • /
    • 1998
  • In this paper, we propose signaling procedures amon network elements for a connection rerouting method which can reduce inter-switch handoff processing delay reduces the delay in the connection re-routing by reserving VPI/VCIs for possible inter-switch handoff calls in advance. Additionally, we mathematically analyze the signaling procedures and then suggest solutions to the relations with cluser size, network topoloty, handoff-request rete and handoff delay. With simulation, the solutions are validated. From numerical examples, we concluded taht handoff delay, one of the handoff QoSs, can be satisfied by adjusting the cluster size and network topology according to the handoff -request rate of service area. With our proposed signaling and analytic methods, we concluded that the connection rerouting method using cluster-sectoring effectively reduces the delay of inter-switch handoff processing than dynamic connection rerouting method. Our solutions are useful in guaranteeing the requested handoff delay (especially, inter-switch handoff delay) when the connection rerouting method is applied to ATM-based wireless/wired integrated network.

  • PDF

Seismic Performance of Beam-Column Connections for Special Moment Frame Using 600 MPa Flexural Reinforcement (600 MPa 휨 철근을 사용한 특수 모멘트 골조의 보-기둥 접합부의 내진성능)

  • Hwang, Hyeon-Jong;Park, Hong-Gun;Choi, Won-Seok;Chung, Lan;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.591-601
    • /
    • 2011
  • An experimental study was performed to evaluate the seismic performance of beam-column connections using 600 MPa re-bars for beam flexural reinforcement. Three full scale specimens of interior beam-column connection and two specimens of exterior beam-column connection were tested under cyclic loading. The specimens were designed to satisfy the requirements of Special Moment Frame according to current design code. The structural performance of the specimens with 600 MPa re-bar were compared with that of the specimen with 400 MPa re-bars. The test results showed that bond-slip increased in the beam-column joint. However, the load-carrying capacity, deformation capacity, and energy dissipation capacity of the specimens with 600 MPa re-bar were comparable to those of the specimens with 400 MPa re-bars.

Experimental Study on Pull-out Strength of Glued-in Rods Connection according to Adhesive (접착제에 따른 Glued-in Rod 접합부 인발성능에 관한 실험 연구)

  • Park, Keum-Sung;Oh, Keunyeong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.2
    • /
    • pp.149-160
    • /
    • 2022
  • In this study, a pull-out test considering the adhesive type, embedded length, and direction of re-bar was conducted to evaluate the pull-out performance of glued-in rod joints using timber and adhesive produced in Korea. In the test, the specimens using liquid adhesive showed better pull-out performance, and the longer the embedded length of the re-bar, the higher the maximum tensile load by inducing the yield of the re-bar first. Through the test results, a glued-in rod joints design, which is advantageous to design the adhesive strength stronger than the yield strength of re-bar, was proposed, and a correction factor of 0.75 for the adhesive strength considering construction error was also suggested.