• 제목/요약/키워드: RC control

검색결과 569건 처리시간 0.036초

A Fully Differential RC Calibrator for Accurate Cut-off Frequency of a Programmable Channel Selection Filter

  • Nam, Ilku;Choi, Chihoon;Lee, Ockgoo;Moon, Hyunwon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.682-686
    • /
    • 2016
  • A fully differential RC calibrator for accurate cut-off frequency of a programmable channel selection filter is proposed. The proposed RC calibrator consists of an RC timer, clock generator, synchronous counter, digital comparator, and control block. To verify the proposed RC calibrator, a six-order Chebyshev programmable low-pass filter with adjustable 3 dB cut-off frequency, which is controlled by the proposed RC calibrator, was implemented in a $0.18-{\mu}m$ CMOS technology. The channel selection filter with the proposed RC calibrator draws 1.8 mA from a 1.8 V supply voltage and the measured 3 dB cut-off frequencies of the channel selection LPF is controlled accurately by the RC calibrator.

체적 제어법을 이용한 철근 콘크리트 구조물의 비선형 해석 (Nonlinear Analysis of RC Structures Using Volume Control Method)

  • 송하원;남상혁;이준희;임상묵
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.891-897
    • /
    • 2006
  • The volume control method which utilize a pressure node added into a finite shell element can overcome the drawbacks of conventional load control method and displacement control method. In this study, an improved volume control method is introduced for effective analysis of path-dependant behaviors of RC structures subjected to cyclic loading. RC shell structures including RC hollow columns are anlayized by discretizing the structures with layered shell elements and by applying in-plane two dimensional constitutive equations for concrete layers and reinforcement layers of the shell elements. The so-called path dependant volume control method is verified by comparing analysis results with other data including experimental results.

  • PDF

RC 기술의 자동화 장치 개발에 관한 연구(II) -위치 제어기의 개선- (A Study on the Automation Equipment Development of RC Technology(II) -Improvement of Position Controller-)

  • 김기준;김상진;송자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.314-316
    • /
    • 1994
  • The operation of RC(Rod Consolidation) technology carry out highly radiation environment. It requires remote operation and automation for efficient handling and for minimizing radiation exposure to the operator. So we investigated up and down position control of shock absorber device in RC system. To verify the research experimentally, a RC system was set up and PI control method was applied. Fuzzy control method was also tested to further improve control behavior.

  • PDF

Circulating Current Harmonics Suppression for Modular Multilevel Converters Based on Repetitive Control

  • Li, Binbin;Xu, Dandan;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1100-1108
    • /
    • 2014
  • Modular multilevel converters (MMCs) have emerged as the most promising topology for high and medium voltage applications for the coming years. However, one particular negative characteristic of MMCs is the existence of circulating current, which contains a dc component and a series of low-frequency even-order ac harmonics. If not suppressed, these ac harmonics will distort the arm currents, increase the power loses, and cause higher current stresses on the semiconductor devices. Repetitive control (RC) is well known due to its distinctive capabilities in tracking periodic signals and eliminating periodic errors. In this paper, a novel circulating current control scheme base on RC is proposed to effectively track the dc component and to restrain the low-frequency ac harmonics. The integrating function is inherently embedded in the RC controller. Therefore, the proposed circulating current control only parallels the RC controller with a proportional controller. Thus, conflicts between the RC controller and the traditional proportional integral (PI) controller can be avoided. The design methodologies of the RC controller and a stability analysis are also introduced. The validity of the proposed circulating current control approach has been verified by simulation and experimental results based on a three-phase MMC downscaled prototype.

피로강도와 사용성을 고려한 RC 바닥판의 최소두께 (Minimum Thickness of RC Bridge Slab Considering Fatigue and Serviceability)

  • 황훈희;조창빈;김병석;정철헌
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.248-251
    • /
    • 2004
  • This study was performed to propose the minimum thickness of RC slab that satisfies constructibility, fatigue safety, and serviceability requirements such as deflection control. Three different minimum thicknesses are calculated using concrete shear and rebar fatigue formulas, and deflection control, respectively, and checked by constructiblity. The maximum of these three minimum thicknesses is proposed as the minimum thickness of RC slab, which shows that the minimum thickness requirement of RC slab from Korean Bridge Design Code can be thinner than now.

  • PDF

A Fast-Transient Repetitive Control Strategy for Programmable Harmonic Current Source

  • Lei, Wanjun;Nie, Cheng;Chen, Mingfeng;Wang, Huajia;Wang, Yue
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.172-180
    • /
    • 2017
  • The repetitive control (RC) strategy is widely used in AC power systems because of its high performance in tracking period signal and suppressing steady-state error. However, the dynamic response of RC is determined by the fundamental period delay $T_0$ existing in the internal model. In the current study, a ($nk{\pm}i$)-order harmonic RC structure is proposed to improve dynamic performance. The proposed structure has less data memory and can improve the tracking speed by n/2 times. $T_0$ proves the effectiveness of the ($nk{\pm}i$)-order RC strategy. The simulation and experiments of ($6k{\pm}1$)-order and ($4k{\pm}1$)-order RC strategy used in the voltage source inverter is conducted in this study to control the harmonic current source, which shows the validity and advantages of the proposed structure.

증강현실 기반의 FPV(First Person View) RC 카 레이싱 게임 (Augmented Reality-Based First Person View RC Car Racing Game)

  • 박성은;김진현;김학겸
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2022년도 추계학술발표대회
    • /
    • pp.800-802
    • /
    • 2022
  • 최근 성인들을 위한 '키덜트 장난감'의 관심도가 증가하고 있다. 그중 높은 매출을 보이는 RC 카와 VR 의 콘텐츠 부족 및 대중화 문제를 해결하면 시장규모를 성장시킬 수 있다고 판단한다. 본 논문은 차별화된 RC 카 레이싱 게임 개발을 목표로 한다. 스마트폰용 VR 기기를 착용해 영상을 보며 컨트롤러로 RC 카를 조종한다. 또한 실시간 객체 검출이 가능한 YOLOv5 를 활용해 표지판 인식 및 바운딩 박스, 표지판 라벨, 라벨 음성 출력 기능과 오픈 소스 기반 실시간 컴퓨터 비전인 OpenCV 기반 알고리즘을 활용하여 차선을 인식해 이를 기반으로 영상 처리를 거쳐 가상 차선 및 가상 트랙을 출력한다. 결론적으로 RC 카와 VR 로 구현하여 이를 통해 부족한 VR 컨텐츠를 추가하고 접근성을 강화한다.

Effective CFRP retrofit strategy for flexural deficient RC beams

  • Banjara, Nawal Kishor;Ramanjaneyulu, K.
    • Structural Engineering and Mechanics
    • /
    • 제69권2호
    • /
    • pp.163-175
    • /
    • 2019
  • Structural deterioration arises due to aging, environmental effects, deficiencies during design and construction phase, and overloading. Experimental and numerical investigations are carried out in this study to evaluate the performance of control and flexural deficient reinforced concrete (RC) beams under monotonic loading. Three levels of flexural deficiency are considered in this study. After confirming load carrying capacities of control and flexural deficient beams, the flexural deficient RC beams are strengthened with carbon fibre reinforced polymer (CFRP) fabric. CFRP strengthened RC beams are tested under monotonic loading and compared with the performance of control specimen. Further, non-linear finite element analyses are also carried out to evaluate the flexural performance of control, deficient and CFRP strengthened flexural deficient RC beams. There is good correlation between results of experimental and numerical investigations. Numerical approach presented in this study can be adopted for assessing the adequacy of CFRP retrofit measure.

스마트폰 기반 RF4CE URC 프레임워크의 설계 및 구현 (R-URC: Smartphone based RF4CE Universal Remote Control Framework)

  • 구본현;안태원;박용석;손태식
    • 전자공학회논문지CI
    • /
    • 제47권2호
    • /
    • pp.48-53
    • /
    • 2010
  • RC(Remote Control)기술들은 CE(Consumer Electronics)들에게 사용자의 명령을 전달하고 편리하게 제어할 수 있도록 해주는 기술이다. 그러나 CE 기기의 성능 향상과 새로운 개념의 기기들이 개발됨에 따라 다양한 기기간 통신 필요성과 그러한 기기를 제어하기 위한 진보된 RC 기능에 대한 요구가 증대되고 있다. 그러나 기존의 대표적인 IR 기반의 RC 방식은 거리의 제약과 에너지 소모 등 많은 제약사항을 가지고 있다. 본 논문에서는 이러한 제약사항들을 해결하기 위해, 스마트폰 단말에 RF4CE 표준을 지원하는 R-URC(Smartphone based RF4CE Universal Remote Control Framework) URC 프레임워크를 제안한다. 제안된 URC 시스템은 CE 제어와 관한 RC 표준으로 09년 3월에 발표된 ZigBee RF4CE를 기반으로 설계되었으며, 제안한 시스템의 효율성 검증을 위해 기기들 간의 컨텐츠 공유 및 제어 기능을 실제 LED TV, NotePC, 그리고 스마트폰에 적용한 실험을 수행하였다.

Development of Nucleic Acid Lateral Flow Immunoassay for Rapid and Accurate Detection of Chikungunya Virus in Indonesia

  • Ajie, Mandala;Pascapurnama, Dyshelly Nurkartika;Prodjosoewojo, Susantina;Kusumawardani, Shinta;Djauhari, Hofiya;Handali, Sukwan;Alisjahbana, Bachti;Chaidir, Lidya
    • Journal of Microbiology and Biotechnology
    • /
    • 제31권12호
    • /
    • pp.1716-1721
    • /
    • 2021
  • Chikungunya fever is an arboviral disease caused by the Chikungunya virus (CHIKV). The disease has similar clinical manifestations with other acute febrile illnesses which complicates differential diagnosis in low-resource settings. We aimed to develop a rapid test for CHIKV detection based on the nucleic acid lateral flow immunoassay technology. The system consists of a primer set that recognizes the E1 region of the CHIKV genome and test strips in an enclosed cassette which are used to detect amplicons labeled with FITC/biotin. Amplification of the viral genome was done using open-source PCR, a low-cost open-source thermal cycler. Assay performance was evaluated using a panel of RNA isolated from patients' blood with confirmed CHIKV (n = 8) and dengue virus (n = 20) infection. The open-source PCR-NALFIA platform had a limit of detection of 10 RNA copies/ml. The assay had a sensitivity and specificity of 100% (95% CI: 67.56% - 100%) and 100% (95% CI: 83.89% - 100%), respectively, compared to reference standards of any positive virus culture on C6/36 cell lines and/or qRT-PCR. Further evaluation of its performance using a larger sample size may provide important data to extend its usefulness, especially its utilization in the peripheral healthcare facilities with scarce resources and outbreak situations.