• Title/Summary/Keyword: R600a

Search Result 778, Processing Time 0.028 seconds

Control System of 600kW EBOP for Molten Carbonate Fuel Cell Generation System (600kW급 용융탄산염 연료전지 발전시스템용 EBOP 제어시스템)

  • Hwang, Tai-Sik;Joung, Woo-Taek;Yang, Byung-Hoon;Kim, Kwang-Seob;Kwon, Byung-Ki;Choi, Chang-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.18-20
    • /
    • 2008
  • An electrical balance of plant(EBOP) of a 600kW molten carbonate fuelcell (MCFC) has to transit from grid-connected(GC) mode to grid-independent(GI) mode when a grid is in a fault conditions. A minimum transition time is limited by four cycle for a 600kW MCFC to ride through a grid fault. In this paper, we propose a control algorithm of a 600kW EBOP for a MCFC system. The EBOP has three operation modes, i.e., GC mode, GI mode, and grid-synchronized(GS) mode. The EBOP controls output currents in a GC mode and regulates output voltages in GI or GS mode. GS mode is defined as an interface between GC mode and GI mode to make a mode transition smooth, i.e., limitation of inrush currents, regulation of output voltages within ANSI standard. Simulations and experiments carried out to verify the effectiveness of the proposed control algorithm.

  • PDF

Analysis of Performance Characteristics of a Cascade Refrigeration System with Internal Heat Exchanger using Natural Refrigerants (천연냉매를 사용하는 내부 열교환기 부착 캐스케이드 냉동시스템의 성능 특성 분석)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1123-1128
    • /
    • 2009
  • In this paper, the cycle performance characteristics of a cascade refrigeration system with internal heat exchanger using natural refrigerants is presented to offer the basic design data for the operating parameters of the system. This system considered in this study is consisted of a high temperature cycle using a carbon dioxide(R744) and low temperature cycle using refrigerants such as R290, R1270, R600a and Ethane. The main results were summarized as follows : The COP of the cascade refrigeration system of R600a with internal heat exchanger is the highest grade in low temperature cycle using refrigerants such as R290, R1270, R600a and Ethane. The COP of the cascade refrigeration system with internal heat exchanger only in high temperature cycle is the highest value among three type cycle, such as only low temperature cycle, only high temperature cycle and all the cycle.

Condensation heat transfer characteristics of hydrocarbon. refrigerants inside horizontal tubes (수평평활관내 탄화수소계 냉매의 응축전열 특성에 관한 연구)

  • 이용언;박승준;정진호;장승환;오후규
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.15-20
    • /
    • 2001
  • This study investigated the condensation heat transfer coefficients of R-22, R-290 and R-600a inside horizontal tube. Heat transfer measurements were peformed for smooth tube with outside diameter of 12.7 mm Condensation temperatures and mass velocity were ranged from 308 K to 323 K and $51kg/\textrm{m}^2s$s to $250kg/\textrm{m}^2s$, respectively. The test results showed that the local condensation heat transfer coefficients increased as the mass flux increased, and also the effects of mass velocity on heat transfer coefficients of R-290 and R-600a were less than R-22. Average condensation heat transfer coefficients of natural refrigerants were superior to that of R-22. The present results had a good agreement with Haraguchi's correlation.

  • PDF

Performance Evaluation of Propane(R290)/Isobutane(R600a) Mixture as a Substitute for CFC12 in Domestic Refrigerators (프로판/이소부탄 혼합냉매를 적용한 가정용 냉장고의 성능에 관한 연구)

  • Lim, B.H.;Park, Y.B.;Yoo, H.K.;Jung, D.S.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.249-265
    • /
    • 1995
  • The performance of a refrigerant mixture of propane(R290)/isobutane(R600a) as a substitute for CFC12 was investigated in a domestic refrigerator with single evaporator. A thermodynamic cycle simulation indicated an increase in COP of a 1.7 to 2.4% with R-290/600a in the composition range of 0.2 to 0.6 mass fraction of R290 compared to CFC12. For the tests, two units($299{\ell}$, $465{\ell}$) were used. All refrigeration components remained the same throughout the tests, except that the length of capillary tube and amount of charge were changed for the mixture. The refrigerators were fully instrumented with more than 20 thermocouples, 2 pressure transducers, and watt/watt-hour meter for each refrigerator. 'Energy consumption test' and 'no load pulldown test' were performed under the same condition. The experimental results obtained with the same compressor indicated that R-290/600a mixture at 0.6 mass fraction of R290 showed a 3 to 5% increase in energy efficiency and a faster cooling speed compared to CFC12. The R-290/600a mixture showed a shorter compressor on-time and a lower compressor dome temperature than CFC12. In conclusion, the proposed hydrocarbon mixture seems to be an appropriate candidate to replace CFC12 without causing more environmental problems.

  • PDF

Prediction on Performance of Cascade Refrigeration System using Alternative Freon and Natural Refrigerants (대체 프레온 및 자연 냉매를 이용하는 이원 냉동시스템의 성능 예측)

  • Kim, Jong-Ryeol;Roh, Geon-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1427-1433
    • /
    • 2012
  • In this paper, cycle performance analysis of cascade refrigeration system using alternative FREON refrigerants and natural refrigerants are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooled and superheated degree, and condensing and evaporating temperature, temperature difference of cascade heat exchanger in cascade refrigeration system. The COP of cascade refrigeration system increases with the increasing subcooled degree, but there is no significant changes with the increasing superheated degree. The COP of cascade refrigeration system depends on evaporating and condensing temperatures of cascade heat exchanger. Therefore, subcooled degree, evaporating and condensing temperature of cascade heat exchanger using alternative FREON refrigerants and natural refrigerants have an effect on the COP of this system. In this paper, COP of cascade refrigeration system using (R23 / R290), (R23 / R600), (R23 / R600a), (R23 / R717), (R744 / R404A) are higher 20 ~ 36 % than (R23 / R22), using R23 for low temperature system and R22 for high temperature system.

Performance Evaluation of R-22 Alternative Refrigerants with Hydrofluorocarbon and Hydrocarbon (HFC 및 탄화수소를 포함한 R-22 대체냉매의 성능평가)

  • 김창년;박영무;이병권;임종성
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.315-324
    • /
    • 2000
  • R-410A, R-407C, and four refrigerant mixtures composed of R-32, R-l34a, R-l43a, R-l52a, R-600(butane), and R-600a(isobutane) were tested in an attempt to replace R-22 used in most of the residential air conditioners. The performance evaluation was carried out in a psychrometric calorimeter test facility using a residential spilt type air conditioner under the KS rating conditions. Except for the lubricant and hand-operated expansion valve, the other parts of the air conditioner were the same with the commercial system. Performance characteristics were measured; COP, capacity, compressor power, and VCR. R-410A was shown to have 5.5% higher COP and 3.5% lower capacity than R-22. R-32/134a/600a (42.8/ 46.0/11.2 wt%) mixture have the best performance among the four refrigerant mixtures composed of hydrofluorocarbon and hydrocarbon. This inixture have 3.0% lower COP and 1.6% lower capacity than R-22.

  • PDF

Effects of Cobalt-60 Gamma Ray Irradiation on Blood Cells and Enzyme Activity of Albino Rats (코발트-60 감마선(線) 조사(照射)가 흰쥐의 혈액성분(血液成分) 및 수종(數種) 효소(酵素)의 활성(活性)에 미치는 영향(影響))

  • Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.47-63
    • /
    • 1985
  • This paper was aimed to study the effects of Cobalt-60 gamma ray irradiation on Albino rat blood cells and the activity of enzymes were measured using blood cell auto analyzer (Cell-Dyn 900) and enzyme autoanalyzer (Gilford 3500) respectively. Cobalt-60 gamma rays those are grouped into 200R, 400R, 600R, 800R, 1,000R, 1,200R, 1,300R, 1,400R, 1,500R and 1,600R to the rats of male and female and measured the numeral varieties of blood corpuscles of the rats and the active varieties of enzyme of acid, alkaline phosphatase (ACP, ALP), lactic acid dehydrogenase (LDH), glutamic oxaloacetic transaminase (GOT) and glutamic pyruvic transaminase. (GPT) those came out after 1, 3, 5 or 7 days. The results are summarized as follows: 1. In both case of male and female, the numeral varieties of the erythrocytes, in the 200R group of irradiation showed the minimum value in the 3 days group and a tendency of increase in the 5 and 7 days groups, while the numeral varieties of the leucocytes in every groups of irradiation showed a tendency of a rapid decrease after a day. The numeral varieties of the blood platelet in both case of male and female didn't show generally any great change in a day and 3 days groups, but showed a rapid decreasing appearance after the 5 days. 2. In both case of male and female, the activities of ACP were on the decrease gradually after 3 days of the irradiation and the activities of ALP were on the decrease after 5 days. Similarly in both case of mate and female, the activities of LDH showed the decrease after 3 and 5 days, and the phenomenous of GOT showed an appearance of increase in a day, but decreased after 3 days. As for the GPT activities couldn't find any great change in the male rats in comparison with the control groups, but in the female rats a tendency of the increase in 600R, 800R, 1,000R groups after 3 days. 3. In the case of the irradiation of high quantity of ray more than 1,200R, all rats died after 4 days, and by the irradiation of 1,600R all rats died after 3 days, and it showed the sensitive response of a living body to the irradiation of high quantity.

  • PDF

A Comparative Study on the Documentary Conditions of International Trade Transaction (국제무역거래에서의 서류조건에 관한 비교연구 - Incoterms(R) 2010규칙과 UCP 600규칙을 중심으로 -)

  • Sin, Jung-Sik
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.54
    • /
    • pp.99-122
    • /
    • 2012
  • According to the United Nations Convention on the International Sale of Goods, the Seller must deliver the goods, hand over any documents relating to the them and transfer the property the to the goods as required by the contract, and buyer must pay the price for the goods and take delivery of them as required by the contract. In particular, the seller provides the documents is important. If the documents are discrepancies in credit, the beneficiary may not receive the payment. So It is important to study on conditions of documents in international trade. Documents provided by the seller shall be determined by express terms. If there is no agreement on the express terms, it shall be determined by the implied terms or governing law terms. In practice Seller shall provide the documents are as follows, For example, transport documents, commercial invoice, certificate of origin, insurance policy, packing list, inspection certificate etc. As stated above if it can not be determined by express terms, it is determined by the implied terms. In international trade, leading to the implied terms is incoterms(R) 2010 and UCP 600. Incoterms(R) 2010 define the seller must provide the goods and the commercial in conformity with the sales contract and any other evidence of conformity that may be required by the contract and UCP 600 are rules that apply to documentary credit. This paper, the practical utility between Incoterms(R) 2010 and UCP 600 is studied.

  • PDF