• 제목/요약/키워드: R123

검색결과 675건 처리시간 0.035초

Measurement of Absorption Coefficient for Quantum Confined Stark Effect In GaAsP/In P MQW Na Refractive Index Change

  • Song, Ju-Bin;Killey, R.
    • Journal of the Optical Society of Korea
    • /
    • 제5권4호
    • /
    • pp.123-130
    • /
    • 2001
  • In this paper, we report measurement of absorption coefficient for various InGaAs MQW QCSE device structures. The absorption spectra over a range of QCSE were obtained from measured photocurrent spectra. The refractive index changes with applied electric field were calculated from the absorption spectra.

(WEAK) IMPLICATIVE HYPER K-IDEALS

  • Saeid, A.Borumand;Borzooei, R.A.;Zahedi, M.M.
    • 대한수학회보
    • /
    • 제40권1호
    • /
    • pp.123-137
    • /
    • 2003
  • In this note first we define the notions of weak implicative and implicative hyper K-ideals of a hyper K-algebra H. Then we state and prove some theorems which determine the relationship between these notions and (weak) hyper K-ideals. Also we give some relations between these notions and all types of positive implicative hyper K-ideals. Finally we classify the implicative hyper K-ideals of a hyper K-algebra of order 3.

BEST PROXIMITY POINTS FOR CONTRACTIVE MAPPINGS IN GENERALIZED MODULAR METRIC SPACES

  • V. Anbukkarasi;M. Marudai;R. Theivaraman
    • Korean Journal of Mathematics
    • /
    • 제31권2호
    • /
    • pp.123-131
    • /
    • 2023
  • In this paper, we prove existence of best proximity points for 2-convex contraction, 2-sided contraction, and M-weakly cyclic 2-convex contraction mappings in the setting of complete strongly regular generalized modular metric spaces that generalize many results in the literature.

[I-123]IPT 약역학 컴퓨터시뮬레이션을 이용한 민감도 측정 및 간편화된 운반체 정량분석 방법들의 비교분석 연구 (The Measurement of Sensitivity and Comparative Analysis of Simplified Quantitation Methods to Measure Dopamine Transporters Using [I-123]IPT Pharmacokinetic Computer Simulations)

  • 손혜경;나상균;이희경;김희중
    • 대한핵의학회지
    • /
    • 제31권1호
    • /
    • pp.19-29
    • /
    • 1997
  • 목 적 : 본 연구의 목적은 IPT 약역학 컴퓨터시뮬레이션을 이용하여 혈류공급량, 도파민 운반체량 그리고 시간의 함수인 혈류와 도파민 운반체의 민감도를 측정하고 간편화된 정적 영상을 얻을 수 있는가의 가능성과 그 경우 도파민 운반체량의 변화를 어느 정도 반영하는가를 측정하고자 하는 것이었다. 또한 실제 결합능을 나타낸다고 가정된 $k_3/k_4$의 비를 반영하는 (BG-OCC)/OCC와 (ABBG-ABOCC)/ABOCC의 비를 이용한 방법과 그래프적 분석 방법의 정확성 및 유용성과 방사성의약품의 약역학을 분석하는 기법을 연구하고자 하였다. 방 법 : [I-123]IPT와 SPECT로 얻은 약 2시간 동적 선조체 시간방사능곡선, 동적 피 시간방사능곡선, 그리고 삼구획 역학모형을 이용, $K_1,\;k_2\;k_3\;k_4$ 속도상수들을 획득하였다. 위의 동적 피 시간방사능곡선과 속도상수들 중 혈류공급과 관련된 $K_l$ 또는 도파민 운반체량과 관련된 $k_3$의 양을 변경하면서 5분부터 5분씩 증가하여 120분까지의 혈류와 도파민 운반체의 민감도를 측정하였다. 또한 $k_3$의 양을 변화시킨 데이터를 이용하여 선조체와 후두엽에서의 시간방사능곡선을 계산한 후 각 방법의 정밀도를 측정하기 위해 (BG-OCC)/OCC와 $R_A$ 비값들과 그래프적 분석 방법을 이용하여 구한 $R_A$값들과 참값 $k_3/k_4$의 관계를 시간방사능곡선과 선형회귀 분석으로 계산하였다. 결 과 : 선조체와 후두엽에서의 $K_1,\;k_2\;k_3\;k_4$ 속도상수는 각각 $1.26{\pm}5.41%,\;0.044{\pm}19.58%,\;0.031{\pm}24.36%,\;0.008{\pm}22.78%$$1.36{\pm}4.76%,\;0.170{\pm}6.89%,\;0.007{\pm}23.89%,\;0.007{\pm}45.09%$이었다. 이들 속도상수를 이용하여 얻은 혈류 민감도와 도파민 운반체의 민감도는 30분, 60분, 90분, 120분에 각각 0.50, 0.35, 0.29, 0.23 그리고 0.19, 0.40, 0.53, 0.61이었다. 실제 속도상수의 비 $k_3/k_4$에 대한 (BG-OCC)/OCC와 $R_A,\;R_v$간의 상관계수는 각각 0.983, 0.984, 0.999이었으며 그때의 기울기는 각각 1.76, 0.47, 1.25이었다. 결 론 : IPT 약역학은 시간이 흐름에 따라 혈류량의 변동에 비해 도파민 운반체량의 변동에 더욱 민감한 경향을 보였으며 $k_3/k_4$에 대한 (BG-OCC)/OCC, $R_A,\;R_v$의 결과간에 좋은 상관관계를 가졌다. 따라서 이러한 약역학 컴퓨터시뮬레이션이 SPECT 영상을 이용한 도파민 운반체 또는 수용체 정량분석을 최적화하는데 매우 유용할 것으로 생각된다.

  • PDF

뇌성마비 아동의 근력과 호흡기능의 상관관계 (Correlation Between Muscle Strength, Pulmonary Function and Respiratory Muscle in Children with Cerebral Palsy)

  • 신승오;김난수
    • 대한물리의학회지
    • /
    • 제11권2호
    • /
    • pp.123-130
    • /
    • 2016
  • PURPOSE: This study was conducted to determine correlations between grip and lower limb muscle strength and pulmonary function and respiratory muscle in children with cerebral palsy. METHODS: Subjects were 17 children with cerebral palsy. Inclusion criteria for participation were having GMFCS from I to III grade and ability to independently blow into a spirometer. Pulmonary function and respiratory muscle were measured with a spirometer. All subjects performed maximal expiratory flow maneuvers using a spirometer in order to determine their forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), peak expiratory flow (PEF) and FEV1/FVC, and maximum inspiratory pressure (MIP) and maximum expiratory pressure (MEP). Muscle strength was measured in terms of grip strength and lower limb muscle strength in terms of knee extension strength with a dynamometer and manual digital muscle tester respectively. Data were analyzed using Person product correlation. RESULTS: Grip strength significantly positively correlated with FVC (r=0.95, p<0.01), FEV1 (r=0.95, p<0.01), PEF (r=0.84, p<0.01), MIP (r=0.65, p<0.01) MEP (r=0.71, p<0.01) and lower limb strength with FVC (r=0.72, p<0.01), FEV1 (r=0.69, p<0.01), PEF (r=0.54, p<0.05), and MEP (r=0.69, p<0.01). CONCLUSION: Grip and lower limb muscle strengths of children with cerebral palsy were positively correlated pulmonary function and respiratory muscle.

AKARI OBSERVATIONS OF MASSIVE STAR-FORMING REGIONS INDICATIVE OF LARGE-SCALE CLOUD-CLOUD COLLISIONS

  • Hattori, Yasuki;Kaneda, Hidehiro;Ishihara, Daisuke;Yamagishi, Mitsuyoshi;Kondo, Toru;Sano, Hidetoshi
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.123-125
    • /
    • 2017
  • We present our AKARI study of massive star forming regions where a large-scale cloud-cloud collision possibly contributes to massive star formation. Our targets are Spitzer bubbles, which consist of two types of bubbles, closed and broken ones; the latter is a candidate of the objects created by cloud-cloud collisions. We performed mid- and far-infrared surface photometry toward Spitzer bubbles to obtain the relationship between the total infrared luminosity, $L_{IR}$, and the bubble radius, R. As a result, we find that $L_{IR}$ is roughly proportional to $R^{\beta}$ where ${\beta}=2.1{\pm}0.4$. Broken bubbles tend to have larger radii than closed bubbles for the same $L_{IR}$.

Optimization of Multi-Atlas Segmentation with Joint Label Fusion Algorithm for Automatic Segmentation in Prostate MR Imaging

  • Choi, Yoon Ho;Kim, Jae-Hun;Kim, Chan Kyo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권3호
    • /
    • pp.123-131
    • /
    • 2020
  • Purpose: Joint label fusion (JLF) is a popular multi-atlas-based segmentation algorithm, which compensates for dependent errors that may exist between atlases. However, in order to get good segmentation results, it is very important to set the several free parameters of the algorithm to optimal values. In this study, we first investigate the feasibility of a JLF algorithm for prostate segmentation in MR images, and then suggest the optimal set of parameters for the automatic prostate segmentation by validating the results of each parameter combination. Materials and Methods: We acquired T2-weighted prostate MR images from 20 normal heathy volunteers and did a series of cross validations for every set of parameters of JLF. In each case, the atlases were rigidly registered for the target image. Then, we calculated their voting weights for label fusion from each combination of JLF's parameters (rpxy, rpz, rsxy, rsz, β). We evaluated the segmentation performances by five validation metrics of the Prostate MR Image Segmentation challenge. Results: As the number of voxels participating in the voting weight calculation and the number of referenced atlases is increased, the overall segmentation performance is gradually improved. The JLF algorithm showed the best results for dice similarity coefficient, 0.8495 ± 0.0392; relative volume difference, 15.2353 ± 17.2350; absolute relative volume difference, 18.8710 ± 13.1546; 95% Hausdorff distance, 7.2366 ± 1.8502; and average boundary distance, 2.2107 ± 0.4972; in parameters of rpxy = 10, rpz = 1, rsxy = 3, rsz = 1, and β = 3. Conclusion: The evaluated results showed the feasibility of the JLF algorithm for automatic segmentation of prostate MRI. This empirical analysis of segmentation results by label fusion allows for the appropriate setting of parameters.